Search NASA⌕ Search

SEARCH · Search NASA

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synchrophasor Data Correction under GPS Spoofing Attack: A State Estimation-Based Approach

GPS spoofing attack (GSA) has been shown to be one of the most imminent threats to almost all cyber-physical systems incorporated with the civilian GPS signal. Specifically, for our current agenda of the modernization of the power grid, this may greatly jeopardize the benefits provided by the pervasively installed phasor measurement units (PMU). In this paper, we consider the case where synchrophasor data from PMUs are compromised due to the presence of a single GSA, and show that it can be corrected by signal processing techniques. In particular, we introduce a statistical model for synchrophasorbased power system state estimation (SE), and then derive the spoofing-matched algorithms for synchrophasor data correction against GPS spoofing attack. Different testing scenarios in IEEE 14-, 30-, 57-, 118-bus systems are simulated to show the proposed algorithms’ performance on GSA detection and state estimation. Numerical results demonstrate that our proposed algorithms can consistently locate and correct the spoofed synchrophasor data with good accuracy as long as the system observability is satisfied. The accuracy of state estimation is significantly improved compared with the traditional weighted least square method and approaches the performance under the Genie-aided method.

Phasor measurement units, Global Positioning Syste↗

SIMS Data Correction Procedure for Quasi‐Simultaneous Arrival ( QSA ) Under‐counting and Ramifications of Misapplication

Isotope geochemistry requires isotope ratios measured using secondary ion mass spectrometry (SIMS) to be made with optimal precision and accuracy. Under some analytical conditions when using electron multiplier detectors, secondary ions may be under‐counted because of quasi‐simultaneous arrival (QSA) at the first dynode. The relative magnitude of the associated QSA correction to raw measured isotopic ratios can be up to seventy permil or more. Therefore, not applying the correction, or misapplication of it could lead to significant inaccuracies in published isotope ratio data. Examples and ramifications of the latter are described in addition to a straightforward procedure for QSA under‐counting correction.

Geochemistry & Geophysics↗

Data Correction of Intensity Modulated Small Angle Scattering

Abstract To investigate long length scale structures using neutron scattering, real space techniques have shown certain advantages over the conventional methods working in reciprocal space. As one of the real space measurement techniques, spin echo modulated small angle neutron scattering (SEMSANS) has attracted attention, due to its relaxed constraints on sample environment and the possibility to combine SEMSANS and a conventional small angle neutron scattering instrument. In this report, we present the first implementation of SEMSANS at a pulsed neutron source and discuss important corrections to the data due to the sample absorption. These corrections allow measurements made with different neutron wavelengths and SEMSANS configurations to be overlaid and give confidence that the measurements provide an accurate representation of the density correlations in the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Closed-Form Solution for Synchrophasor Data Correction under GPS Spoofing Attack

Phasor Measurement Units (PMUs) are increasingly being deployed to augment monitoring, protection and control applications in the power grid. PMUs rely on the Global Positioning System (GPS) for generation of time-synchronized and accurate measurements. However, civilian GPS signals, being unencrypted, are susceptible to GPS spoofing attacks (GSA). Hence ensuring the integrity of GPS-timing dependent synchrophasor data has become critical. In this paper, a closed-form analytical solution for estimating the GSA phase shift has been proposed and integrated to the spoofing detection & correction framework. Extensive simulations have been performed in order to verify the accuracy of the solution in determining the location and the phase shift of the compromised PMU. Time domain dynamic simulations presented in this paper demonstrate the applicability of the proposed solution for near-real-time detection of GSA, and this will enable faster detection and correction of phase angles of compromised synchrophasor data.

Synchrophasor, PMUs, GPS, Spoofing, Data Correctio↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

SAIL-Net Raw and Post Corrected POPS Data Fall 2021 - Summer 2023

SAIL-Net is a DOE funded project in the East River Watershed near Crested Butte, Colorado with the goal of advancing our understanding of aerosol-cloud interactions in complex, mountainous regions. Through the deployment of a network of six low cost microphysics nodes in Fall 2021 in the same domain at the SAIL campaign, SAIL-Net provides data on aerosol size distributions, cloud condensation nuclei (CCN), and ice nucleation particles (INP). This network enables the investigation of small-scale variations in complex terrain. Two datasets are provided - one containing raw data and the other containing post-corrected data. The raw dataset provides the raw data recorded from the POPS which were deployed at each of the six sites. These data are organized by site and broken down into daily data files. The six site names used here are: “gothic”, “irwin”, “cbtop”, “cbmid”, “pumphouse”, and “snodgrass”. These data are not cleaned or post-corrected, but some flags have been added. The data are reported at 1 second time resolution. The post-corrected dataset provides the post-corrected and cleaned data recorded from the POPS which were deployed at each of the six sites. This data are also organized by site (same as those found in the raw data) and broken down into daily data files. Unlike the raw POPS data, these data have already been cleaned to remove what we believe are bad values. These data should be ready to use with no cleaning. For a full description of the cleaning and post-correction process, see the readme.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Cameras for the COSMO K-coronagraph

Digital image sensors are ubiquitous in astronomical instrumentation and it is well known that they suffer from issues that must be corrected for data to be scientifically useful. I present discussion on errors resulting from digitization and characterization of nonlinearity and ADC errors of the PhotonFocus MV-D1024E cameras selected for the K-coronagraph of the Coronal Solar Magnetism Observatory. I derive an analytic expression for quantization errors. The MV-D1024E camera has adequate bit depth for which quantization error is not an issue. I show that this is not the case for all cameras, particularly those with deep wells and low read noise. The impact of nonlinearity and ADC errors on science observations of the K-coronagraph is analyzed using a simplified telescope model. Errors caused by the camera ADCs result in systematic errors in the measurement of the polarimetric signal of several times 10{sup −9} B {sub ⊙}, which is about an order of magnitude above the desired sensitivity. I demonstrate a method for post-facto data correction using a lookup table and derive parameters from camera characterization measurements that were made with a lab setup. Nonlinearity is traditionally addressed with a global correction. I show through analysis of calibration data that for the MV-D1024E this correction leaves residual systematic errors after dark and gain correction of up to 1% of the signal. I demonstrate that a pixel-wise correction of nonlinearity reduces the errors to below 0.1%. These corrections are necessary for the K-coronagraph data products to meet the science requirements. They have been implemented in the instrument data acquisition system and data reduction pipeline. While no other instruments besides the K-coronagraph or cameras besides the MV-D1024E are discussed here, the results are illustrative for all instruments and cameras.

79 ASTRONOMY AND ASTROPHYSICS↗

Fixed-Site KAZR b1 Data Processing: Corrections, Calibrations, and Processing Report

The U.S. Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) User Facility operates three fixed-site observatories: Eastern North Atlantic (ENA), North Slope of Alaska (NSA), and Southern Great Plains (SGP). Each fixed site has a wide variety of atmospheric instrumentation that has been collecting data for at least 10 years (NSA and SGP over 25 years). Each site is unique because it represents a different climate state. The environment at ENA is characterized by marine stratocumulus clouds and one of the key scientific areas of focus is the interaction of these clouds with aerosols. At NSA the focus is on arctic climate and cloud and radiative processes in a high-latitude environment. SGP represents a mid-latitude, mid-continent climate that experiences environmental cycles on diurnal and seasonal time scales. The ARM observatories are all meant to improve understanding of atmospheric processes that can then be better incorporated into weather and climate models. Another common thread between the fixed sites is the focus on cloud processes. Each site is equipped with at least one radar that provides continuous remote-sensing observations of clouds and precipitation. This report details the analysis of a1-level radar data at the fixed sites and the process for generating b1-level data. While b1-level data have been produced for ARM campaigns at the mobile facilities, this is the first analysis led by ARM radar mentors to correct data at the fixed sites. In particular, we focus on calibrations and corrections of the Ka-band ARM Zenith Radars (KAZRs) at ENA, NSA, and SGP. Ongoing and future work will involve corrections applied to other fixed-site radars.

54 ENVIRONMENTAL SCIENCES↗

Soft Syndrome Decoding of Quantum LDPC Codes for Joint Correction of Data and Syndrome Errors

Quantum errors are primarily detected and corrected using the measurement of syndrome information which itself is an unreliable step in practical error correction implementations. Typically, such faulty or noisy syndrome measurements are modeled as a binary measurement outcome flipped with some probability. However, the measured syndrome is in fact a discretized value of the continuous voltage or current values obtained in the physical implementation of the syndrome extraction. In this paper, we use this "soft" or analog information without the conventional discretization step to benefit the iterative decoders for decoding quantum low-density parity-check (QLDPC) codes. Syndrome-based iterative belief propagation (BP) decoders are modified to utilize the syndrome-soft information to successfully correct both data and syndrome errors simultaneously, without repeated measurements. We demonstrate the advantages of extracting the soft information from the syndrome in our improved decoders, not only in terms of comparison of thresholds and logical error rates for quasi-cyclic lifted-product QLDPC code families, but also for faster convergence of iterative decoders. In particular, the new BP decoder with noisy syndrome performs as good as the standard BP decoder under ideal syndrome.

97 MATHEMATICS AND COMPUTING↗

TRACER Radar b1 Data Processing: Corrections, Calibrations, and Processing Report

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility deployed the first ARM Mobile Facility (AMF1) to Houston, Texas for the Tracking Aerosol Convection Interactions Experiment (TRACER) field campaign. The TRACER campaign was conducted from October 1, 2021 to September 30, 2022, with an intensive operational period (IOP) from June 1 to September 30, 2022. To investigate the life cycles of convective cells in the polluted and humid urban environment of Houston, ARM deployed cloud and precipitation radars, including the C-band Scanning ARM Precipitation Radar (CSAPR2), the X/Ka-band Scanning ARM Cloud Radar (SACR), and the Ka-band ARM Zenith cloud Radar (KAZR), as shown in Figure 1. This report presents an analysis of radar data quality, hardware calibrations, and radar data corrections.

54 ENVIRONMENTAL SCIENCES↗

Methods for evaluation and treatment of data shift

This is a code repository for a set of tools for detecting and mitigating data shifts in machine learning. The goal of the tools is to provide capabilities for determining when new data sets differ from training data sets and for adapting existing models to new data or correcting data shifts (via domain adaptation). The components will be written in Python, a high-level programming language that takes advantage of the Python ecosystem of high-quality open-source packages for machine learning and signal processing.

Parikh, Nidhi↗

Release of the NDI 2.2.0

The Nuclear Data Interface 2.2.0 has been released. It includes the addition of charged particle dE/dx (stopping power) data, the ability to read in NDI-formatted binary data, corrections to TN data, and other minor changes and bug fixes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release of the NDI 2.2.0alpha

The Nuclear Data Interface 2.2.0alpha has been released. It includes the addition of charged particle dE/dx (stopping power) data, the ability to read in NDI-formatted binary data, corrections to TN data, CP 2011 and CP 2020 data, and other minor changes and bug fixes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-I-08: CT Image Ring Artifact Reduction Based On Prior Image

Purpose: In computed tomography (CT) system, CT images with ring artifacts will be reconstructed when some adjacent bins of detector don’t work. The ring artifacts severely degrade CT image quality. We present a useful CT ring artifacts reduction based on projection data correction, aiming at estimating the missing data of projection data accurately, thus removing the ring artifacts of CT images. Methods: The method consists of ten steps: 1) Identification of abnormal pixel line in projection sinogram; 2) Linear interpolation within the pixel line of projection sinogram; 3) FBP reconstruction using interpolated projection data; 4) Filtering FBP image using mean filter; 5) Forwarding projection of filtered FBP image; 6) Subtraction forwarded projection from original projection; 7) Linear interpolation of abnormal pixel line area in the subtraction projection; 8) Adding the interpolated subtraction projection on the forwarded projection; 9) FBP reconstruction using corrected projection data; 10) Return to step 4 until the pre-set iteration number is reached. The method is validated on simulated and real data to restore missing projection data and reconstruct ring artifact-free CT images. Results: We have studied impact of amount of dead bins of CT detector on the accuracy of missing data estimation in projection sinogram. For the simulated case with a resolution of 256 by 256 Shepp-Logan phantom, three iterations are sufficient to restore projection data and reconstruct ring artifact-free images when the dead bins rating is under 30%. The dead-bin-induced artifacts are substantially reduced. More iteration number is needed to reconstruct satisfactory images while the rating of dead bins increases. Similar results were found for a real head phantom case. Conclusion: A practical CT image ring artifact correction scheme based on projection data is developed. This method can produce ring artifact-free CT images feasibly and effectively.

60 APPLIED LIFE SCIENCES↗

Optimization of yttrium-90 PET for simultaneous PET/MR imaging: A phantom study

Purpose: Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study. Methods: The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background. Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach. Results: Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder. Conclusions: MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.

60 APPLIED LIFE SCIENCES↗