Search NASA⌕ Search

SEARCH · Search NASA

Results for “current interrupt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Current interrupt method for calculating the electrochemical impedance in a solid oxide electrolysis stack

Here, in this work the time domain response of Solid Oxide Electrolysis Cells (SOEC) to a current interruption was transformed into the frequency domain using a carrier function Laplace transform, which is fit to the experimental data using a MATLAB Complex Nonlinear Least Squares (CNLS) solver. The hardware implementation, consisting principally of a high-speed switch and a fast-logging Analog to Digital Converter (ADC), was assembled and tested using a calibration module to assess the accuracy, repeatability, and speed of acquisition of the prototype device as compared against a calibrated commercial impedance spectrometer. Additionally, the current interrupt device and commercial FRA were used to acquire the impedance spectra of a four cell SOEC stack with a large, 300 cm 2 , active cell area.

SOEC↗

Dopant Optimization of Donors in Semiconductor Opening Switches to Eliminate Prepulse

Semiconductor opening switches are solid-state devices capable of delivering nanosecond, hundreds of kilovolts pulses by interrupting kiloamps of current. The interruption of the current occurs in a moderately doped p-region when a high electric field region (HFR) is formed. The HFR occurs because the reverse pumping current cannot be supported by the saturation velocity and majority carrier concentration of the doping level. However, the donor profile also significantly affects the pulse performance. A secondary prepulse occurs if a secondary HFR is formed at the interface of the background n-doping and N+ doping (X n ) . By moving the location of X n deeper into the diode, the effect of the prepulse is reduced. This article investigates the effect of the donor doping profile on the performance metrics of semiconductor opening switches through technology computer-aided design (TCAD) simulations and experimental results. Through a SILVACO TCAD optimization, we designed a P + /p/n - base/n/N + where the intersection of the moderate p-region and intrinsic n-base region (X p ) is at 160 μm and X n is at 220 μm. This profile is fabricated via silicon epitaxy. Experimentally, it is shown that a deep X n (220 μm) compared with a shallow X n (300 μm) reduces the rise time by >5× . In addition, the magnitude of current density during interruption affects the prepulse foot and pulse shape. At lower current densities without the graded donor profile, high peak voltages are not achieved. Comparing the experimental results to the TCAD simulations shows that the model is predictive under high-current densities in the semiconductor opening switch (SOS) regime.

nanosecond pulse power↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid mapping of electrochemical processes in energy-conversion devices

Electrochemical impedance spectroscopy (EIS) is ubiquitously applied to identify physicochemical processes governing the performance of energy-conversion devices. However, deconvolution and interpretation of impedance phenomena are limited by measurement throughput and a dearth of scalable analysis methods. Here, we demonstrate an approach to quickly collect and coherently analyze large volumes of electrochemical data. In this study, we accelerate impedance characterization by combining rapid measurements in time and frequency domains, which are interpretably transformed using the distribution of relaxation times (DRT) and a new distribution of phasances (DOP) model. This method provides excellent agreement with EIS and decreases measurement time by an order of magnitude. High-throughput spectra are then distilled into detailed electrochemical maps. This approach is applied to a Li-ion battery and a protonic ceramic electrochemical cell as practical case studies, demonstrating how mapping can richly characterize physicochemical relationships that are difficult to decipher with conventional measurement and analysis methods.

25 ENERGY STORAGE↗

SCR-based Medium Voltage DC Solid-State Circuit Breaker

This paper describes a medium voltage solid-state circuit breaker (SSCB) based on SCR technology, featuring short fault-interruption time and a minimal turn-off auxiliary circuit. The SSCB design incorporates a specialized SCR and a commutation circuit designed with an objective to reduce the required SCR hold-off/turn-off time, tq, which primarily determines the fault interruption duration. To validate the design, simulation analysis is presented, and a 1.5 kV 300 A SSCB prototype has been built and tested. The results confirm the effectiveness of the proposed design philosophy demonstrating the SSCB's ability to interrupt a 200 A load current in less than 50 μs. The proposed SCR-based SSCB has been developed for DC applications but is equally applicable to AC applications.

Kandula, Prasad [ORNL] (ORCID:0000000174017284)↗

Physics-informed heterogeneous graph neural networks for DC blocker placement

The threat of geomagnetic disturbances (GMDs) to the reliable operation of the bulk energy system has spurred the development of effective strategies for mitigating their impacts. One such approach involves placing transformer neutral blocking devices, which interrupt the path of geomagnetically induced currents (GICs) to limit their impact. The high cost of these devices and the sparsity of transformers that experience high GICs during GMD events, however, calls for a sparse placement strategy that involves high computational cost. To address this challenge, we developed a physics-informed heterogeneous graph neural network (PIHGNN) for solving the graph-based dc-blocker placement problem. Our approach combines a heterogeneous graph neural network (HGNN) with a physics-informed neural network (PINN) to capture the diverse types of nodes and edges in ac/dc networks and incorporates the physical laws of the power grid. We train the PIHGNN model using a surrogate power flow model and validate it using case studies. Results demonstrate that PIHGNN can effectively and efficiently support the deployment of GIC dc-current blockers, ensuring the continued supply of electricity to meet societal demands. Furthermore, our approach has the potential to contribute to the development of more reliable and resilient power grids capable of withstanding the growing threat that GMDs pose.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment

Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

Energy & Fuels↗

Cost-Benefit Analysis of Electricity Resilience Projects: State of the Art and Gap Analysis

Utilities and regulators must weigh the benefits of electricity resilience projects against their costs, which would be passed on to customers. Cost-benefit analysis (CBA) is an appropriate method for assessing this tradeoff. Here, in this paper we review the literature on CBA of electricity resilience projects and analyze gaps in the available methods and tools. The costs of resilience projects are typically straightforward to estimate but their benefits — particularly the avoided costs of power interruptions — are complex to quantify and monetize. A common perception among practitioners is that current CBA tools are not sufficiently mature to be adopted into real-world practice. We propose an electricity resilience CBA framework consisting of several elements: risks, physical impacts, power interruptions, economic impacts, and resilience projects. While methods for some elements are well-developed, there is a need for novel approaches to value avoided power interruptions, integrate multiple risks and benefit streams, and incorporate uncertainty.

Cost-benefit analysis↗

Automated Calibration System for Beam Current Monitor

The Beam Current Monitor (BCM) measures the instantaneous current in a beam. This work aims to develop an automated calibration system for the BCM to address the need for calibration without interrupting beam operation. We strive to create a synchronous calibration method integrated into the master timeline by utilizing the pulsed nature of synchrotrons to run calibration pulses during inter-pulse gaps. This improvement should enhance operational efficiency, ensure safe operation, and help mitigate beam loss, all by enabling intermittent calibration during the operation of the accelerator. This is accomplished by developing a Python program that interfaces with a Keithley 6221 DC and AC source and a Keithley 2182A Nanovoltmeter. The program configures both of these devices to perform a selected mode of the current sweep, allows for the initiation of the current sweep, collects the measured voltage data from the 2182A, stores the collected data to the computer in a CSV file, and graphs the collected data.

Haller, James↗

A Generic FSC Wind Park EMT Model with IEEE Std 2800-Compliant Fault Ride-Through Capability

The modern power grid is seeing more and more electricity come from renewable sources like wind farms, which use sophisticated power electronics instead of traditional spinning generators. To keep everything running smoothly and meet industry standards such as IEEE 2800, these systems need smart control strategies. In our work, we built a flexible computer model of a full-scale wind farm converter that can handle grid disturbances without shutting down. When a fault or storm hits, the model’s built-in logic automatically adjusts the currents it sends to the grid and protects its internal energy storage, ensuring the wind farm stays connected and doesn’t damage its own equipment. Once the disturbance clears, the model restores normal operation seamlessly, so there’s no long interruption in power delivery. At the same time, it carefully regulates the voltage where the wind farm ties into the larger grid, helping to maintain safe voltage levels across the network. Our simulations show that this control setup not only meets all the requirements of IEEE Standard 2800 but also allows the wind farm to recover quickly and predictably, keeping the lights on no matter what happens on the grid.

17 WIND ENERGY↗

Towards rational control of seed oil composition: dissecting cellular organization and flux control of lipid metabolism

Plant lipids represent a fascinating field of scientific study, in part due to a stark dichotomy in the limited fatty acid (FA) composition of cellular membrane lipids vs the huge diversity of FAs that can accumulate in triacylglycerols (TAGs), the main component of seed storage oils. With few exceptions, the strict chemical, structural, and biophysical roles imposed on membrane lipids since the dawn of life have constrained their FA composition to predominantly lengths of 16–18 carbons and containing 0–3 methylene-interrupted carbon-carbon double bonds in cis-configuration. However, over 450 “unusual” FA structures can be found in seed oils of different plants, and we are just beginning to understand the metabolic mechanisms required to produce and maintain this dichotomy. Here we review the current state of plant lipid research, specifically addressing the knowledge gaps in membrane and storage lipid synthesis from 3 angles: pathway fluxes including newly discovered TAG remodeling, key acyltransferase substrate selectivities, and the possible roles of “metabolons.”

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Frost Formation and Novel Defrost Techniques for Commercial Refrigeration Applications (NFE-19-07879)

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test a heat exchanger defrosting approach using radiant energy, including ultraviolet-C, -B, and -A. A preliminary test conducted at Oak Ridge National Laboratory demonstrated the concept of ultraviolet-based defrosting, which melts frost on the fin surface of a heat exchanger without increasing its overall temperature, thereby offering a new defrosting method that does not interrupt heat exchanger operation. Building on this key finding, this CRADA outlines a plan for upgrading the test equipment and for further testing to bridge the gap between the concept and its feasibility for industrial applications. This report also provides a brief review of existing defrosting technologies, the current state of the experimental system, and future parametric experiment plans.

99 GENERAL AND MISCELLANEOUS↗

Analysis of Frost Formation and Novel Defrost Techniques for Commercial Refrigeration Applications

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test a heat exchanger defrosting approach using radiant energy, including ultraviolet-C, -B, and -A. A preliminary test conducted at Oak Ridge National Laboratory demonstrated the concept of ultraviolet-based defrosting, which melts frost on the fin surface of a heat exchanger without increasing its overall temperature, thereby offering a new defrosting method that does not interrupt heat exchanger operation. Building on this key finding, this CRADA outlines a plan for upgrading the test equipment and for further testing to bridge the gap between the concept and its feasibility for industrial applications. This report also provides a brief review of existing defrosting technologies, the current state of the experimental system, and future parametric experiment plans.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Radiography for TRISO Buffer Layer Density Measurement

Tristructural isotropic (TRISO) fuel particles consist of a central uranium-bearing kernel and a series of coating layers designed to retain fission products and to ensure fuel performance. Several parameters such as thickness and density must be measured for these coating layers to show that they conform with fuel specifications. Current methods for measuring the density of pyrolytic carbon and silicon carbide layers (liquid gradient density column) and the buffer layer (mercury porosimetry) generate Resource Conservation and Recovery Act (RCRA) radiological-mixed waste. In addition, measurement of buffer and inner pyrolytic carbon layer densities require hot sampling or interrupted coating runs and the mercury porosimetry method used for buffer density measurement only measures the mean buffer density, not the interparticle distribution. A new approach has been evaluated to measure the density of coating layers in TRISO particles based on the dependence of x-ray attenuation in radiographs on material density. This method does not generate RCRA mixed waste, measures density on a particle-by-particle basis, and in principle is capable of measuring the density of all coating layers in a single process. Initial results using thinned TRISO particle sections to evaluate radiography measurement of density as a quality control characterization method are reported herein. In this work, the primary focus is on measurement of the density of the buffer layer; however, with appropriate calibration the method should be applicable to other coating layers. Improvements to the initial method and a full demonstration of the method on the remaining coating layers may be pursued as a future effort.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SPARTAN and IMPROVE Comparison Experiment (SPICE) Interim Campaign Report

SPICE (the SPARTAN and IMPROVE Comparison Experiment) aims to obtain and quantify comparisons between aerosol PM 2.5 mass concentration measurements from the University of Oklahoma (OU) Surface Particulate Matter Network (SPARTAN) station and the U.S. Environmental Protection Agency (EPA) Interagency Monitoring of Protected Visual Environments (IMPROVE) station hosted by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility at ARM’s Southern Great Plains (SGP) observatory in Oklahoma. Aerosols—both natural and anthropogenic—affect human populations in multiple ways. Much of ARM’s research focuses on how aerosols influence weather and climate through their optical and radiative effects, as well as their impacts on clouds and precipitation. However, aerosols also pose direct risks to humans and other organisms through inhalation, with the severity of health impacts depending on particle size, chemical composition, and duration of exposure. The IMPROVE network was established by the U.S. EPA to monitor air quality, including visible clarity as well as total and chemically speciated aerosol mass concentrations. The ARM SGP site hosts the IMPROVE SOGP station. Separately, the SPARTAN network operates a globally distributed set of stations similar to IMPROVE but with an emphasis on remote deployment and semi-autonomous operation for use beyond the borders of the United States (IMPROVE only operates within the U.S.). The University of Oklahoma operates a SPARTAN station. To establish confidence in the OU SPARTAN instrumentation and measurement protocol relative to the EPA-certified IMPROVE station, the OU SPARTAN station is currently deployed at SGP in close proximity to the IMPROVE SOGP station. The SPICE campaign was envisioned as a contiguous calendar-year effort for 2025 to capture seasonal variation in mass loading as well as composition. However, independent of the SPICE campaign, the SPARTAN network adopted a new filter construction part-way through the year, interrupting our contiguous data set. Thus, to obtain a contiguous data set with a uniform consistent configuration, SPICE desires an extension through 2026.

54 ENVIRONMENTAL SCIENCES↗

Testing Capabilities for Superconducting Magnets at Fermilab

This presentation will focus on the current testing capabilities for superconducting magnets at Fermilab, highlighting existing systems, recent upgrades, and future plans. The Vertical Magnet Test Facility (VMTF) remains a cornerstone for testing superconducting magnets in R&D applications, maintaining its established capabilities. Stand 4 continues to support the Hi-Lumi AUP production line of magnets in cryostats and has achieved significant improvements through a redesign of lead connections, resolving issues with liquid helium levels and resistance, culminating in a successful endurance test without interruption. Similarly, Stand 7 underwent commissioning and a lead redesign to reduce heat load, while its core testing capabilities remain unchanged. Looking forward, Stand 3 is undergoing a redesign, with plans to restart and begin commissioning by the end of 2025, introducing new features such as background magnetic field testing and upgraded power supplies. Fermilab is also advancing the High Field Vertical Magnet Test Facility (HFVMTF), designed to support the fusion and magnet R&D program, with commissioning scheduled for 2025 and critical components, including the cryostat and power supplies, being delivered. Enhancing all operations, the newly commissioned IB1 cryoplant now offers automated overnight helium production and efficient transfer to a 10,000-liter dewar, streamlining support across all test stands. This talk will provide a comprehensive overview of testing capabilities, and showcasing how Fermilab is advancing its capabilities to meet the evolving demands of superconducting magnet testing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Stable Solid Oxide Electrolysis Cells for Low-Cost Hydrogen Production

The project objective was to demonstrate a solid oxide cell-based steam electrolysis stack that exhibits robustness, reliability, endurance, hydrogen purity, and produces hydrogen at elevated pressure of 2 to 3 bar. Innovative materials and processing methods were evaluated to improve degradation characteristics. Performance improvement focused on nearly all layers involved in the cell and stack assembly. Primary attention was paid to zirconia-ceria interface resistance control via sintering optimization and decrease in degradation from the oxygen electrode by evaluating low strontium (Sr) or Sr-free composition for both the oxygen electrode and current collection layer. Stack robustness was addressed by validating redox tolerance of fuel electrode, confirming capability of cells to survive repeated thermal cycles, studying the effect of pressure on performance and degradation, evaluating the effect of contamination on fuel and oxygen electrode performance and degradation, and identifying mitigation strategies to improve performance. The characterization included evaluation of electrochemical performance and stability followed by microstructural analysis. At the cell level, performance and stability improvements were achieved by incorporating a Sr-free oxygen electrode and a denser oxygen electrode barrier layer. At the stack level, pressurized operation reduces demand on first stage compression, the redox tolerant fuel electrode mitigates risk from service interruptions, and improvements to interconnect coating alleviate chromium (Cr) contamination effects. The denser barrier layer was achieved by adding a sintering aid to the samaria-doped ceria (SDC) composition that reduced sintering temperature by 150 °C. The resulting density was on par with the baseline SDC barrier layer density and the lower sintering temperature resulted in less resistive phase formation during sintering. Button cell tests did not demonstrate a change in performance when exposed to silicon (Si) or manganese (Mn) impurities to the fuel electrode and Cr impurity to the oxygen electrode. More detailed study however is warranted. The project addressed SOEC performance and stability at the cell and stack levels through a systematic approach to known sources of degradation that were combined and tested in three stack tests using an electrolyte supported cell design to allow for evaluation of a variety of fuel and oxygen electrode compositions. STK-82 and STK-83 had identical compositions. STK-100 incorporated the best materials and processing variables developed under this and concurrent projects, and was tested at elevated pressure in steam electrolysis. • STK-82 recovered performance after redox and thermal cycling, demonstrating the robustness of the stack and seals. It exhibited stable performance in testing for 500 hours in SOEC mode, followed by 300 hours of cycling between SOEC and SOFC tests. Degradation during SOEC operation was 1.8 %/ 1,000 hours. • STK-83 generated hydrogen at >80% steam conversion, and oxygen above 98.5 % purity during pressurized operation. Both hydrogen and oxygen were generated at 3 barg pressure without the use of a pressure vessel. In addition to balanced pressure, electrolysis operation at 1 bar differential pressure across anode and cathode was also demonstrated to substantial the robustness of the cell and seal. • STK-100 measured at initial ambient pressure conditions showed an area specific resistance of 1.1 ohm-cm 2 , and STK-83 had 1.3 ohm-cm 2 .

08 HYDROGEN↗