At least 19 records

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint

Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.

current limiting↗

Water limiting current measurements in anion exchange membrane fuel cells (AEMFCs); part 1: Water limiting current method development

We report water management is critical in optimizing anion exchange membrane fuel cell (AEMFCs) performance and durability. The role of membranes on determining cell water balance in AEMFCs has received limited study. A more thorough understanding of membrane water transport parameters is necessary for thorough cell optimization. In this study, a novel method for probing limiting current based on water flux across an AEMFC is presented for the first time. The water limiting current has been investigated as a function of relative humidity of anode and cathode streams, cathode backpressure and cell operating temperature. From these studies, it is clearly shown that water diffusion through the membrane from the anode is the most critical mechanism for achieving high current density performance and durability. The developed method can act as a novel screening technique that focuses on the impacts of water transport parameters and helps identify promising membrane materials based on their water transport properties. A critical but underappreciated facet of AEMFC performance and durability.

30 DIRECT ENERGY CONVERSION↗

Effect of microphase separation on the limiting current density in hybrid organic-inorganic copolymer electrolytes

Hybrid organic-inorganic block copolymer electrolytes are of interest to enable batteries containing lithium metal anodes. The conductive block is a standard polymer electrolyte of poly(ethylene oxide) and the mechanically rigid block is an inorganic poly(acryloisobutyl polyhedral oligomeric silsesquioxane) polymer. Here, in this paper, we compare a poly(acryloisobutyl polyhedral oligomeric silsesquioxane)-b-poly(ethylene oxide)-b-poly(acryloisobutyl polyhedral oligomeric silsesquioxane) (POSS-PEO-POSS) triblock copolymer and a poly(ethylene oxide)-b- poly(acryloisobutyl polyhedral oligomeric silsesquioxane) (PEO-POSS) diblock copolymer mixed with lithium bis(trifluoromethanesulfonyl)imide salt. We have experimentally measured the limiting current density in lithium symmetric cells containing hybrid organic-inorganic electrolytes at 90 °C. The cells were polarized at a large range of applied current density. The diblock copolymer electrolyte exhibited a clear plateau in cell potential at all current densities below the limiting current density. At low applied current density, the triblock copolymer electrolyte also exhibited a clear plateau in cell potential. At currents approaching the limiting current density, the triblock copolymer electrolyte exhibited an underdamped potential profile. The cell potential did not reach a plateau at current densities above the limiting current in both systems. The diblock and triblock copolymer electrolytes were fully characterized using electrochemical methods to determine the ionic conductivity, cation current fraction, salt diffusion coefficient, and open circuit voltage as a function of salt concentration. Cell potential and salt concentration as functions of position in the cell at various current densities were calculated using Newman's concentrated solution theory. The theoretical limiting current density was calculated to be the current density at which salt is depleted at the cathode. We see quantitative agreement between experimental measurements and theoretical predictions for the limiting current density in the diblock copolymer electrolyte which has an ordered structure at all salt concentrations, while the experimental limiting current density is lower than the theoretical prediction for the triblock copolymer electrolyte, which exhibits a disordered morphology at high salt concentrations.

25 ENERGY STORAGE↗

Small-Signal Analysis of Current-Limiting Grid-Forming Inverters

Grid-forming (GFM) inverters are equipped with a current limiter to protect the device during grid disturbances. Because the intervention of the current limiter can compromise the transient stability of the GFM inverter, various types of current limiter designs and additional frequency-stabilization control methods have been proposed in recent literature to aid in transient GFM inverter stability; however, the small-signal stability implications of adding these additional control blocks during, in particular, off-nominal conditions are not fully understood. To address this challenge, this paper presents a generic small-signal model of a GFM inverter that incorporates various types of current limiters and frequency stability-enhancing controls. With the proposed model, we analyze the root causes of inverter instability, which reveals two critical design trade-offs. First, due to current-limiter engagement caused by a disturbance, the GFM inverter dynamics are altered, which can lead to voltage oscillations. Second, additional frequency-stabilization controls can improve the small-signal stability of the GFM inverter, but at the cost of reduced power and voltage support to the grid. Comprehensive hardware experiments validate the theoretical concept and analysis. The findings in this work underscore the importance of incorporating both transient-response and small-signal dynamics requirements into the design procedure of GFM current limiters and frequency-stabilization controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Limiting Current in Nanostructured Block Copolymer Electrolytes

The next-generation electrolytes for lithium batteries must be able to conduct ions at sufficiently high current densities; yet this regime is rarely studied directly. The limiting current density of an electrolyte quantifies the highest possible rate of ion transport under an applied dc potential. Herein, we report on the limiting current density in twelve nanostructured polystyrene-block-poly(ethylene oxide) (PS-b-PEO, or SEO) copolymer electrolytes. We find that the limiting current at a given salt concentration increases systematically with increasing volume fraction of the PEO block (φ EO ). In contrast, the effective-medium theory, commonly used to analyze conductivity in block copolymer electrolytes, predicts that limiting current is independent of φ EO . To resolve this conundrum, the ionic conductivity, the mutual diffusion coefficient of the salt, and the steady-state current fraction of the block copolymer electrolytes were measured. These measurements enable predictions of limiting current with no adjustable parameters using the concentrated solution theory. We found quantitative agreement between experimentally measured limiting current densities and predictions based on the concentrated solution theory. This work sheds light on how to reliably measure and predict limiting current density in composite electrolytes.

25 ENERGY STORAGE↗

Limiting Current Density in Single-Ion-Conducting and Conventional Block Copolymer Electrolytes

The limiting current density of a conventional polymer electrolyte (PS-PEO/LiTFSI) and a single-ion-conducting polymer electrolyte (PSLiTFSI-PEO) was measured using a new approach based on the fitted slopes of the potential obtained from lithium-polymer-lithium symmetric cells at a constant current density. The results of this method were consistent with those of an alternative framework for identifying the limiting current density taken from the literature. We found the limiting current density of the conventional electrolyte is inversely proportional to electrolyte thickness as expected from theory. The limiting current density of the single-ion-conducting electrolyte was found to be independent of thickness. There are no theories that address the dependence of the limiting current density on thickness for single-ion-conducting electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conductivity-Driven Origin of the Limiting Current in Concentrated Electrolytes

Next-generation electrolyte materials are hindered by their ability to support high currents essential for fast-charge and high-power battery applications. The maximum current supported by an electrolyte, the limiting current, is dictated by the formation of concentration gradients across the electrolyte under an electric field. Most of the literature attributes the onset of the limiting current in concentrated electrolytes to the salt concentration at the positive electrode approaching the solubility limit. Here, in this study, we leverage operando X-ray transmission imaging to measure spatiotemporal salt concentration profiles of a polymer electrolyte in a lithium–indium symmetric cell at a current exceeding the limiting current. The measurement of concentration profiles enables mapping the spatiotemporal electric potential, which comprises an ohmic contribution, governed by conductivity, and an overpotential related to maintaining concentration gradients. We find that a precipitous drop in conductivity at the positive electrode drives the divergence of electric potential, rather than a thermodynamic solubility limit.

Abdo, Emily E. [University of California, Berkeley↗

Evaluation of Ferrite Chip Beads as Surge Current Limiters in Circuits with Tantalum Capacitors

Limiting resistors are currently required to be connected in series with tantalum capacitors to reduce the risk of surge current failures. However, application of limiting resistors decreases substantially the efficiency of the power supply systems. An ideal surge current limiting device should have a negligible resistance for DC currents and high resistance at frequencies corresponding to transients in tantalum capacitors. This work evaluates the possibility of using chip ferrite beads (FB) as such devices. Twelve types of small size FBs from three manufacturers were used to evaluate their robustness under soldering stresses and at high surge current spikes associated with transients in tantalum capacitors. Results show that FBs are capable to withstand current pulses that are substantially greater than the specified current limits. However, due to a sharp decrease of impedance with current, FBs do not reduce surge currents to the required level that can be achieved with regular resistors.

surge current testing↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

Positive-Sequence Phasor Modeling of Droop-Controlled, Grid-Forming Inverters with Fault Current Limiting Function

Traditional positive-sequence phasor models of droop-controlled, grid-forming inverters do not have the fault current limiting function. During a short-circuit fault the model generates unrealistic high fault current making the simulation results less practical. This paper develops a fault current limiting function for the positive-sequence phasor model of droop-controlled, grid-forming inverters, which can effectively limit the inverter output current at the predefined maximum during faults. A user-written model has been developed for the commercially-available software Siemens/PTI PSS/E. Fault studies on a modified IEEE 39-bus system with all grid-forming inverters verify the effectiveness of the developed fault current limiting function. The proposed model can be used to evaluate how the limited fault currents of droop-controlled, grid-forming inverters impact the bulk power system transient stability under fault conditions.

Du, Wei↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗