Search NASASearch

SEARCH · Search NASA

Results for “current limiting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING

Small-Signal Analysis of Current-Limiting Grid-Forming Inverters

Grid-forming (GFM) inverters are equipped with a current limiter to protect the device during grid disturbances. Because the intervention of the current limiter can compromise the transient stability of the GFM inverter, various types of current limiter designs and additional frequency-stabilization control methods have been proposed in recent literature to aid in transient GFM inverter stability; however, the small-signal stability implications of adding these additional control blocks during, in particular, off-nominal conditions are not fully understood. To address this challenge, this paper presents a generic small-signal model of a GFM inverter that incorporates various types of current limiters and frequency stability-enhancing controls. With the proposed model, we analyze the root causes of inverter instability, which reveals two critical design trade-offs. First, due to current-limiter engagement caused by a disturbance, the GFM inverter dynamics are altered, which can lead to voltage oscillations. Second, additional frequency-stabilization controls can improve the small-signal stability of the GFM inverter, but at the cost of reduced power and voltage support to the grid. Comprehensive hardware experiments validate the theoretical concept and analysis. The findings in this work underscore the importance of incorporating both transient-response and small-signal dynamics requirements into the design procedure of GFM current limiters and frequency-stabilization controls.

24 POWER TRANSMISSION AND DISTRIBUTION

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION

Conductivity-Driven Origin of the Limiting Current in Concentrated Electrolytes

Next-generation electrolyte materials are hindered by their ability to support high currents essential for fast-charge and high-power battery applications. The maximum current supported by an electrolyte, the limiting current, is dictated by the formation of concentration gradients across the electrolyte under an electric field. Most of the literature attributes the onset of the limiting current in concentrated electrolytes to the salt concentration at the positive electrode approaching the solubility limit. Here, in this study, we leverage operando X-ray transmission imaging to measure spatiotemporal salt concentration profiles of a polymer electrolyte in a lithium–indium symmetric cell at a current exceeding the limiting current. The measurement of concentration profiles enables mapping the spatiotemporal electric potential, which comprises an ohmic contribution, governed by conductivity, and an overpotential related to maintaining concentration gradients. We find that a precipitous drop in conductivity at the positive electrode drives the divergence of electric potential, rather than a thermodynamic solubility limit.

Abdo, Emily E. [University of California, Berkeley

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting

The Implications of Collisions on the Spatial Profile of Electric Potential and the Space-Charge-Limited Current

The space-charge-limited current (SCLC) in a vacuum diode is given by the Child-Langmuir law (CLL), whose electric potential ϕ(x) ∝ (x/D) 4/3 , where x is the spatial coordinate across the gap and D is the gap separation distance. For a collisional diode, SCLC is given by the Mott-Gurney law (MGL) and ϕ(x) ∝ (x/D) 3/2 . Here, we apply a capacitance argument for SCLC and use the transit time from a recent exact solution for collisional SCLC to show that ϕ(x) ∝ (x/D)ξ for a general collisional gap, where 4/3 ≤ ξ ≤ 3/2 . Furthermore, ξ is strictly a function of νT, where ν is the collision frequency and T is the electron transit time. Using this definition of ξ, we estimate the spatial dependence of the electron velocity and use the gap capacitance to derive an analytic equation for collisional SCLC that agrees within ~4.5% of the exact solution that requires solving parametrically through T. This analytic equation for general ξ asymptotically recovers the CLL as ν → 0 and the MGL as ν → ∞. As a result, matching these limits shows that ξ ≈ 1.40 and V ∝ D 2 ν 2 at the transition from a vacuum to a collisional diode for any device condition.

Anodes

Observation of defect annealing in neutron-irradiated silicon by space-charge-limited current.

Use of space-charge-limited current (SCLC) to observe defect annealing in neutron-irradiated silicon. From the observation of the trap-filled-limit voltage a deep-trap concentration in the irradiated unannealed crystals is found to be at least 1.4 x 10 to the 12th power per cu cm. Shallow traps are also observed. This deep-trap concentration decreases with anneal temperature up to 200 C, above which SCLC can no longer be observed. There is evidence that at least some of this decrease is due to the conversion of the deep traps to shallow traps.

Magee, T. J.

Universal Relationship between Limiting Current and Electrochemical Transport Properties in Malonate-Based Polymer Electrolytes

There is considerable interest in developing high-performance electrolytes for rechargeable lithium batteries. For practical applications, the electrolyte must support large dc currents. However, the parameters most often reported in the literature, conductivity, κ, and current fraction, ρ + , reflect ion transport in the limit of infinitesimal currents. In this limit, the efficacy of an electrolyte is given by the product κρ + . The limiting current density, i lim , is the maximum current density that can be applied across an electrolyte; the cell voltage diverges if the applied current density exceeds ilim. This parameter reflects ion transport in the limit of large dc currents and is therefore of practical interest. It would therefore be convenient if i lim could be predicted from measurements of κρ + . In order to explore this possibility, we studied six malonate-based polymers and PEO at a fixed salt concentration (r = 0.08) and temperature (90°C) using symmetric cells with planar electrodes. Unfortunately, there is no correlation between ilim and κρ + . When the applied current density, i, is less than ilim, the cell voltage approaches a stable plateau, ϕ plateau . Here, we found a linear dependence between i and thickness-normalized plateau potential, ϕ plateau L –1 , irrespective of the magnitude of the applied current. In all seven polymer electrolytes, we found a linear correlation between ilim and the slopes of these lines, σ. In other words, measurements of σ can be used to predict the limiting current.

Jana, Rounak [Lawrence Berkeley National Laborator

A Methodology for the Analysis of Water Oxidation Electrocatalysts in the Absence of Limiting Current that Avoids the Pitfalls of Existing Methods

Water oxidation is an important reaction studied as a way to generate electrons from water, to promote water splitting and the formation of green hydrogen. When using electrodes to drive homogeneous water oxidation catalysis, cyclic voltammograms are analyzed to provide catalytic rate constants. There are two main methods, foot-of-the-wave analysis (FOWA) and limiting current analysis. FOWA relies on approximations inherent to analyzing water oxidation catalysis, such as determining the formal potential of the catalytic intermediate, E 0 cat . Limiting current methods are the optimal way to analyze catalyst performance but rely on observable limiting current, which is virtually never seen in water oxidation. To avoid those issues, a method is proposed for analyzing nonideal cyclic voltammetry waveshapes in water oxidation: by analyzing rate data across a large range of potentials, an optimal potential, E 0 cat , can be obtained, where catalytic current, i cat , is nearly independent of scan rate and has a linear dependency on buffer concentration. Here, the method is applied to four homogeneous water oxidation catalysts with prior extensive electrochemical elucidation, all of which lack an ideal, purely kinetic waveshape in cyclic voltammetry. Application of the method avoids the biases of the other methods cited for the kinetic analyses of water oxidation catalysts.

14 SOLAR ENERGY

Electron trapping in neutron-irradiated silicon studied by space-charge-limited current.

The trapping and detrapping of electrons is studied through measurements of space-charge-limited current in the temperature range of 77 to 293 K in high-purity silicon after irradiation with 14-MeV neutrons. A model is developed which describes most of the results quantitatively and self-consistently, including dc characteristics. Two distinct trap levels exist: the fast levels lie at 0.14 (plus or minus 0.005) eV below the conduction band, and the slow levels lie at 0.47 (plus or minus 0.01) eV below the conduction band. At 77 K, injected free electrons are initially captured by the fast 0.14-eV traps and then sink into the deep 0.47-eV traps, predominantly without being reemitted into the band. Above approximately 110 K, the detrapping rate from the shallow traps becomes so fast that the deep traps dominate. The results also offer a direct verification of the simple model of space-charge-limited current dominated by shallow and deep traps.

Quat, V. T.

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION

Current-limiting voltage regulator

Voltage regulator, which operates within preset current limits, acts as a circuit breaker to prevent overload failure, and automatically resets when the overload is removed. The power dissipated in the series transistor of the circuit is constant from normal load to short circuit condition.

Cleveland, E. F.