Search NASA⌕ Search

SEARCH · Search NASA

Results for “dead time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Discrimination of shot-noise-driven Poisson processes by external dead time - Application of radioluminescence from glass

Ways in which dead time can be used to constructively enhance or diminish the effects of point processes that display bunching in the shot-noise-driven doubly stochastic Poisson point process (SNDP) are discussed. Interrelations between photocount bunching arising in the SNDP and the antibunching character arising from dead-time effects are investigated. It is demonstrated that the dead-time-modified count mean and variance for an arbitrary doubly stochastic Poisson point process can be obtained from the Laplace transform of the single-fold and joint-moment-generating functions for the driving rate process. The theory is in good agreement with experimental values for radioluminescence radiation in fused silica, quartz, and glass, and the process has many applications in pulse, particle, and photon detection.

Saleh, B. E. A.↗

Effect of detector dead time on the performance of optical direct-detection communication links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detection sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulated (PPM) channel is studied by analyzing the error probability. It is shown that, when background noise is negligible, the performance of the detector with dead time is similar to that of a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on badkground intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Effect of Detector Dead Time on the Performance of Optical Direct-Detection Communication Links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detect ion sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulted (PPM) channel is studied by analyzing the error probability. It is shown that, when back- ground noise is negligible, the performance of the detector with dead time is similar to that o f a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on background intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Coding for Communication Channels with Dead-Time Constraints

Coding schemes have been designed and investigated specifically for optical and electronic data-communication channels in which information is conveyed via pulse-position modulation (PPM) subject to dead-time constraints. These schemes involve the use of error-correcting codes concatenated with codes denoted constrained codes. These codes are decoded using an interactive method. In pulse-position modulation, time is partitioned into frames of Mslots of equal duration. Each frame contains one pulsed slot (all others are non-pulsed). For a given channel, the dead-time constraints are defined as a maximum and a minimum on the allowable time between pulses. For example, if a Q-switched laser is used to transmit the pulses, then the minimum allowable dead time is the time needed to recharge the laser for the next pulse. In the case of bits recorded on a magnetic medium, the minimum allowable time between pulses depends on the recording/playback speed and the minimum distance between pulses needed to prevent interference between adjacent bits during readout. The maximum allowable dead time for a given channel is the maximum time for which it is possible to satisfy the requirement to synchronize slots. In mathematical shorthand, the dead-time constraints for a given channel are represented by the pair of integers (d,k), where d is the minimum allowable number of zeroes between ones and k is the maximum allowable number of zeroes between ones. A system of the type to which the present schemes apply is represented by a binary- input, real-valued-output channel model illustrated in the figure. At the transmitting end, information bits are first encoded by use of an error-correcting code, then further encoded by use of a constrained code. Several constrained codes for channels subject to constraints of (d,infinity) have been investigated theoretically and computationally. The baseline codes chosen for purposes of comparison were simple PPM codes characterized by M-slot PPM frames separated by d-slot dead times.

Moision, Bruce↗

Live-timer method of automatic dead-time correction for precision counting

Automatic correction for dead time losses in nuclear counting experiments is implemented by a simple live timer arrangement in which each counting interval is extended for compensation for the dead time during that interval. this method eliminates repetitious manual calculations, source of error, and dependence upon paralysis shifts.

Porges, K. G.↗

Dead-time effects in microchannel-plate imaging detectors

The observed counting rates of microchannel plate (MCP) based detectors for high resolution observations of celestial EUV and X-ray sources vary over many orders of magnitude; the counting capability of an individual channel, however, is not high, and is associated with dead-times ranging from 0.1 msec to 1 sec. The dead-time increases with the area illuminated; attention is presently given to laboratory determinations of the count rate characteristics of a MCP detector as a function of illuminated area, and a model is developed for these results' use in the interpretation of space observations.

Zombeck, Martin V.↗

Dead-time effects in pulse-counting Digicon detectors

The Hubble Space Telescope's High Resolution Spectrograph employs two pulse-counting Digicon detectors to record UV spectra. At higher measured count rates, the intervals between photon arrivals become comparable to the response time of the electronics, so that not every pulse will be counted; this 'paired pulse' effect causes departures from linearity and must be corrected for during raw data reduction. Attention is given to two analytic equations that quantify the dead-time losses. The less attenuated spectra are noted to be severely distorted by these losses; a comparison with the undistorted low count rate data allows a detailed analysis to be made of the pulse-counting characteristics over five decades of input event rates. The present equations and calibration methods should be applicable to all kinds of multichannel pulse-counting detectors.

Ebbets, Dennis C.↗

Measuring Sulfur Isotope Ratios from Solid Samples with the Sample Analysis at Mars Instrument and the Effects of Dead Time Corrections

The Sample Analysis at Mars (SAM) instrument suite comprises the largest science payload on the Mars Science Laboratory (MSL) "Curiosity" rover. SAM will perform chemical and isotopic analysis of volatile compounds from atmospheric and solid samples to address questions pertaining to habitability and geochemical processes on Mars. Sulfur is a key element of interest in this regard, as sulfur compounds have been detected on the Martian surface by both in situ and remote sensing techniques. Their chemical and isotopic composition can belp constrain environmental conditions and mechanisms at the time of formation. A previous study examined the capability of the SAM quadrupole mass spectrometer (QMS) to determine sulfur isotope ratios of SO2 gas from a statistical perspective. Here we discuss the development of a method for determining sulfur isotope ratios with the QMS by sampling SO2 generated from heating of solid sulfate samples in SAM's pyrolysis oven. This analysis, which was performed with the SAM breadboard system, also required development of a novel treatment of the QMS dead time to accommodate the characteristics of an aging detector.

Franz, H. B.↗

Interface Circuit for Laser Doppler Velocimeters

New circuit displays more information to user and provides higher data-collection rates. Interface circuit facilitates coupling of laser-Doppler-velocimeter outputs to computer for analysis. Enables user to select variety of intermediate data-processing options, including clock frequency, coincidence channel combinations, coincidence times, dead times, digital or analog output, and channels to be analyzed.

Harrison, Dean R.↗

Detector response in time-of-flight mass spectrometry at high pulse repetition frequencies

Dead time effects in chevron configured dual microchannel plates (MCPs) are investigated. Response times are determined experimentally for one chevron-configured dual MCP-type detector and two discrete dynode-type electron multipliers with 16 and 23 resistively divided stages. All of these detectors are found to be suitable for time-of-flight mass spectrometry (TOF MS), yielding 3-6-ns (FWHM) response times triggered on a single ion pulse. It is concluded that, unless there are viable solutions to overcome dead time disadvantages for continuous dynode detectors, suitable discrete dynode detectors for TOF MS appear to have a significant advantage for high repetition rate operation.

Gulcicek, Erol E.↗

An analog study of a shock-position diffuser control on a supersonic turbojet engine

Shock position was assumed to be controlled by air bleed through a diffuser-exit bypass door operated by a second-order servomotor. Pressure disturbance resulting from changes in bypass-door position had whereas a disturbance in engine speed had a large effect on diffuser pressure and could impose severe requirements on diffuser control response. The controlled diffuser response improved with faster servomotor response and smaller diffuser dead time and lag. The effect of diffuser dead time on diffuser response was greater than the effect of diffuser lag.

Novik, David↗

Highly stable high-rate discriminator for nuclear counting

Pulse amplitude discriminator is specially designed for nuclear counting applications. At very high rates, the threshold is stable. The output-pulse width and the dead time change negligibly. The unit incorporates a provision for automatic dead-time correction.

English, J. J.↗

Benchmarking Simulations of the Compton Spectrometer and Imager with Calibrations

The Compton Spectrometer and Imager (COSI) is a balloon-borne 𝛾-ray (0.2-5 MeV) telescope designed to study astrophysical sources. COSI employs a compact Compton telescope design utilizing 12 high-purity germanium double-sided strip detectors and is inherently sensitive to polarization. In 2016, COSI was launched from Wanaka, New Zealand and completed a successful 46-day flight on NASA’s new Super Pressure Balloon. In order to perform imaging, spectral, and polarization analysis of the sources observed during the 2016 flight, we compute the detector response from well-benchmarked simulations. As required for accurate simulations of the instrument, we have built a comprehensive mass model of the instrument and developed a detailed detector effects engine which applies the intrinsic detector performance to Monte Carlo simulations. The simulated detector effects include energy, position, and timing resolution, thresholds, dead strips, charge sharing, charge loss, crosstalk, dead time, and detector trigger conditions. After including these effects, the simulations closely resemble the measurements, the standard analysis pipeline used for measurements can also be applied to the simulations, and the responses computed from the simulations are accurate. We have computed the systematic error that we must apply to measured fluxes at certain energies, which is 6.3% on a rage. Here we describe the detector effects engine and the benchmarking tests performed with calibrations.

Sleator, Clio C.↗