Search NASA⌕ Search

SEARCH · Search NASA

Results for “dielectric fluid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Ceramic Heat Pipe for Thermal Management of a High Frequency Inductor

As the power density of electric machines and power electronics continues to increase to meet the demands of more electric aircraft, the thermal management of these devices becomes increasingly important. Ideally, the thermal management solution of the device should have high thermal conductivity and be electrically insulating so that it can be directly integrated with the device in question. Technical ceramics are a class of materials that meet these two requirements. Direct liquid cooling by submerging electric components in a dielectric fluid is an alternate option, but adds system complexity and may incur pumping loss. In this work, the thermal management solution for a high frequency inductor is presented. A conventional wicked heat pipe is designed that is made from a solid ceramic case with a sintered ceramic wick. This heat pipe can provide structural support for the core and windings and is electrically insulating, so it does not incur any additional eddy current losses from the high frequency magnetic fields. It does not require additional pumping power, because conventional wicked heat pipes are passive devices. In this paper, the manufacturing process of the ceramic heat pipe is also presented. It is shown that the sintering of large diameter spherical ceramic particles is difficult due to their high specific surface area and low surface free energy. To overcome this difficulty, a flux material was used to initiate liquid phase sintering. The results of the sintering trials show that for the 120 μm diameter α-Al2O3powder selected for the wick, the combination of 1650°C sintering temperature and the addition of 5 wt% talc sintered the porous matrix together sufficiently for use as a heat pipe wic

High-frequency Inductor↗

Ceramic Heat Pipe for Thermal Management of a High Frequency Inductor

As the power density of electric machines and power electronics continues to increase to meet the demands of more electric aircraft, the thermal management of these devices becomes increasingly important. Ideally, the thermal management solution of the device should have high thermal conductivity and be electrically insulating so that it can be directly integrated with the device in question. Technical ceramics are a class of materials that meet these two requirements. Direct liquid cooling by submerging electric components in a dielectric fluid is an alternate option, but adds system complexity and may incur pumping loss. In this work, the thermal management solution for a high frequency inductor is presented. A conventional wicked heat pipe is designed that is made from a solid ceramic case with a sintered ceramic wick. This heat pipe can provide structural support for the core and windings and is electrically insulating, so it does not incur any additional eddy current losses from the high frequency magnetic fields. It does not require additional pumping power, because conventional wicked heat pipes are passive devices. In this paper, the manufacturing process of the ceramic heat pipe is also presented. It is shown that the sintering of large diameter spherical ceramic particles is difficult due to their high specific surface area and low surface free energy. To overcome this difficulty, a flux material was used to initiate liquid phase sintering. The results of the sintering trials show that for the 120 μm diameter α-Al2O3 powder selected for the wick, the combination of 1650°C sintering temperature and the addition of 5 wt% talc sintered the porous matrix together sufficiently for use as a heat pipe wick.

High frequency inductor↗

Orientation Effects in Two-Phase Microgap Flow

The high power density of emerging electronic devices is driving the transition from remote cooling, which relies onconduction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolersemploy the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for other applications (e.g., spacecraft and aircraft). The lack of acceptable models andcorrelations for orientation- and gravity-independent operation has limited the use of two-phase coolers in suchapplications. Previous research has revealed that gravitational acceleration plays a diminishing role in establishing flow regimes and transport rates as the channel size shrinks, but there is considerable variation among the proposed microscale criteria and limited research on two-phase flows in low aspect ratio microgap channels. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging systems to exploit this thermal management technique and streamline the technology development process.

orientation↗

Orientation Effects in Two-Phase Microgap Flow

The high power density of emerging electronic devices is driving the transition from remote cooling, which relies on con-duction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for other applications (e.g., spacecraft and aircraft). The lack of acceptable models and correlations for orientation- and gravity-independent operation has limited the use of two-phase coolers in such applications. Previous research has revealed that gravita-tional acceleration plays a diminishing role in establishing flow regimes and transport rates as the channel size shrinks, but there is considerable variation among the proposed microscale criteria and limited research on two-phase flows in low aspect ratio mi-crogap channels. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging sys-tems to exploit this thermal management technique and streamline the technology development process. As a first step toward understanding the effect of gravity on two-phase microgap flow and transport, in the present effort the authors have studied the effect of evaporator orientation and mass flux on near-saturated flow boiling of HFE7100 in a 1.01 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. Orientation-independence, defined as achieving similar critical heat fluxes, heat transfer coefficients, and flow regimes across evaporator orientations, was achieved for mass fluxes of 400 kg/m2-s and greater. The present results are compared to pub-lished criteria for achieving gravity-independence.

orientation↗

Gravity Effects in Two-Phase Microgap Flow

The high power density of emerging electronic devices is driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for aerospace applications, but the lack of acceptable models and correlations for orientation- and gravity-independent operation has limited their use. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging systems to exploit this thermal management technique and streamline the technology development process. As a first step toward understanding the effect of gravity in two-phase microgap flow and transport, in an earlier effort, the authors studied the effects of evaporator orientation, mass flux, and heat flux on flow boiling of HFE7100 in a 1.01 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. Orientation-independence, defined as achieving similar critical heat fluxes, heat transfer coefficients, and flow regimes across orientations, was achieved for mass fluxes of 400 kg/sq.m-s and greater (corresponding to a Froude number of about 0.8). In the present effort, the authors have studied the effects of gravity, mass flux, and subcooling on flow boiling of HFE7100 in a 0.17 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. The Flow Boiling in Microgap Coolers payload experienced about three minutes of weightlessness and shorter periods of high-g (up to about 5 g) during two recent flights aboard the Blue Origin New Shepard reusable launch vehicle. The results from the flight experiments will be presented and compared with published criteria for achieving gravity-independence.

Robinson, Franklin L.↗

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale↗

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale↗

Microgravity Experiments and Numerical Modeling of Rotating Buoyant Convection in a Spherical Shell with Latitudinal Thermal Gradients

The results of numerical model calculations are compared with space laboratory experiments for rotating, thermally driven flow in a hemispherical shell, and various flow regimes are described. A spherically symmetric body force, analogous to gravity, is imposed in the radial direction through the use of a dielectric fluid and an electrostatic potential difference across the gap. The spherical boundaries are maintained at constant temperature profiles (with the pole and the inner sphere being the warmer surfaces), and the equatorial wall is an insulator. Typical parameter combinations result in highly nonlinear, but laminar, flow. For weak enough buoyant forcing, the flow is axisymmetric. It consists of a single meridional cell, rising in warm latitudes (in this case, near the pole) and sinking in cool latitudes, with prograde flow in the equatorial region and near the inner hemisphere for other latitudes, and retrograde motion elsewhere. For fast rotation, the first transition due to the instability of this simple flow is also axisymmetric, consisting of rings of convection in the polar region, which propagate poleward. The first nonaxisymmetric convection occurs at Rayleigh numbers which increase with rotation rate. The form of the convection near the transition also depends upon the rate of rotation. Selected flow patterns near the transition as well as those beyond it are studied numerically. For those cases where there exist laboratory experiments with which to compare, the numerical and experimental results agree very well.

Leslie, Fred W.↗

Electrohydrodynamic heat pipe experiments

Experiments with two electrohydrodynamic heat pipes are reported. Both devices employ an electromechanical flow structure for axial liquid flow and a capillary wicking structure for (1) collection of condensed liquid at the cooled end and (2) distribution of this liquid at the heated end. One device has circumferential grooving for the capillary structure and the other has feltmetal wicking. The experiments successfully demonstrate the electrohydrodynamic heat pipe concept. Compatibility of the two circumferential wick structures with an axial electromechanical flow structure is also demonstrated. A significant mismatch of the capillary groove and electrohydrodynamic pumping capabilities results in severe hydrodynamic burn-out limiting in the first heat pipe. Both devices have very poor over-all thermal conductances of the order of 1-2 W/deg C, reflecting the generally poor heat-transfer properties of the dielectric working fluids required in electrohydrodynamic heat pipes.

Jones, T. B.↗