Differential capacitance sensor as position detector for a magnetic suspension densimeter

In the present work, which consists of adapting a magnetic suspension densimeter for use at pressures up to 350 bars, a differential capacitance sensor is developed for use in the servosystem of a magnetic suspension densimeter for detecting the position of a magnetic buoy. This type of sensor has not been used previously in magnetic suspension densimeters. Its design, performance, and advantages are outlined. A cutaway drawing and a schematic diagram of the capacitance sensor and magnetic buoy are presented and described. The concentric-disk design of the sensor capacitor plates and the high degree of symmetry which results from the printed circuit fabrication approach minimize the sensor sensitivity to lateral displacement of the buoy and to the dielectric constant of the surrounding medium. A high-power microscope is necessary to monitor the position of the buoy relative to the support coil.

Frederick, N. V.↗

Evaluation of Methods for Molecular Dynamics Simulation of Ionic Liquid Electric Double Layers

We investigate how systematically increasing the accuracy of various molecular dynamics modeling techniques influences the structure and capacitance of ionic liquid electric double layers (EDLs). The techniques probed concern long-range electrostatic interactions, electrode charging (constant charge versus constant potential conditions), and electrolyte polarizability. Our simulations are performed on a quasi-two-dimensional, or slab-like, model capacitor, which is composed of a polarizable ionic liquid electrolyte, [EMIM][BF4], interfaced between two graphite electrodes. To ensure an accurate representation of EDL differential capacitance, we derive new fluctuation formulas that resolve the differential capacitance as a function of electrode charge or electrode potential. The magnitude of differential capacitance shows sensitivity to different long-range electrostatic summation techniques, while the shape of differential capacitance is affected by charging technique and the polarizability of the electrolyte. For long-range summation techniques, errors in magnitude can be mitigated by employing two-dimensional or corrected three dimensional electrostatic summations, which lead to electric fields that conform to those of a classical electrostatic parallel plate capacitor. With respect to charging, the changes in shape are a result of ions in the Stern layer (i.e. ions at the electrode surface) having a higher electrostatic affinity to constant potential electrodes than to constant charge electrodes. For electrolyte polarizability, shape changes originate from induced dipoles that soften the interaction of Stern layer ions with the electrode. The softening is traced to ion correlations vertical to the electrode surface that induce dipoles that oppose double layer formation. In general, our analysis indicates an accuracy dependent differential capacitance profile that transitions from the characteristic camel shape with coarser representations to a more diffuse profile with finer representations.

Haskins, Justin B.↗

Influence of Molecular Simulation Model Accuracy on the Interfacial Properties of an Ionic Liquid: Overview of Recommended Practices

Increasing the energy storage capability of ionic liquid supercapacitors will require better understanding of ion-electrode interactions. We have probed the influence of these interactions on the structure and differential capacitance of of an ionic liquid ([EMIM][BF4]) at an ideal graphite interface as a function of model accuracy. Of note, differential capacitance is determined through newly derived and validated fluctuation formulas. In terms of model accuracy, we test electrostatic techniques, electrode charging techniques, and electrolyte interatomic potentials. For electrostatic summations, we employ high cost, high fidelity techniques as well as less expensive, approximate techniques for summation in slab geometry. For electrode charging, uniform, constant-charge and environmentally responsive, constant-potential conditions are employed. For the ionic liquid, constant charge and atomically polarizable models are employed. We comment on the role of model accuracy on the structure and energetics of the electric double layer as well as on the magnitude and shape of differential capacitance.

simulations↗

Structure and Fabrication of a Microscale Flow-Rate/Skin Friction Sensor

A floating element shear sensor and method for fabricating the same are provided. According to an embodiment, a microelectromechanical systems (MEMS)-based capacitive floating element shear stress sensor is provided that can achieve time-resolved turbulence measurement. In one embodiment, a differential capacitive transduction scheme is used for shear stress measurement. The floating element structure for the differential capacitive transduction scheme incorporates inter digitated comb fingers forming differential capacitors, which provide electrical output proportional to the floating element deflection.

Chandrasekharan, Vijay↗

Li-Doped Ionic Liquid Electrolytes: From Bulk Phase to Interfacial Behavior

Ionic liquids have been proposed as candidate electrolytes for high-energy density, rechargeable batteries. We present an extensive computational analysis supported by experimental comparisons of the bulk and interfacial properties of a representative set of these electrolytes as a function of Li-salt doping. We begin by investigating the bulk electrolyte using quantum chemistry and ab initio molecular dynamics to elucidate the solvation structure of Li(+). MD simulations using the polarizable force field of Borodin and coworkers were then performed, from which we obtain an array of thermodynamic and transport properties. Excellent agreement is found with experiments for diffusion, ionic conductivity, and viscosity. Combining MD simulations with electronic structure computations, we computed the electrochemical window of the electrolytes across a range of Li(+)-doping levels and comment on the role of the liquid environment. Finally, we performed a suite of simulations of these Li-doped electrolytes at ideal electrified interfaces to evaluate the differential capacitance and the equilibrium Li(+) distribution in the double layer. The magnitude of differential capacitance is in good agreement with our experiments and exhibits the characteristic camel-shaped profile. In addition, the simulations reveal Li(+) to be highly localized to the second molecular layer of the double layer, which is supported by additional computations that find this layer to be a free energy minimum with respect to Li(+) translation.

molecular dynamics↗

Computational and Experimental Study of Li-doped Ionic Liquids at Electrified Interfaces

We evaluate the influence of Li-salt doping on the dynamics, capacitance, and structure of three ionic liquid electrolytes, [pyr14][TFSI], [pyr13][FSI], and [EMIM][BF4], using molecular dynamics and polarizable force fields. In this respect, our focus is on the properties of the electric double layer (EDL) formed by the electrolytes at the electrode surface as a function of surface potential (Psi). The rates of EDL formation are found to be on the order of hundreds of picoseconds and only slightly influenced by the addition of Li-salt. The EDLs of three electrolytes are shown to have different energy storage capacities, which we relate to the EDL formation free energy. The differential capacitance obtained from our computations exhibits asymmetry about the potential of zero charge and is consistent with the camel-like profiles noted from mean field theories and experiments on metallic electrodes. The introduction of Li-salt reduces the noted asymmetry in the differential capacitance profile. Complementary experimental capacitance measurements have been made on our three electrolytes in their neat forms and with Li-salt. The measurements, performed on glassy carbon electrodes, produce U-like profiles, and Li-salt doping is shown to strongly affect capacitance at high magnitudes of Psi. Differences in the theoretical and experimental shapes and magnitudes of capacitance are rationalized in terms of the electrode surface and pseudocapacitive effects. In both neat and Li-doped liquids, the details of the computational capacitance profile are well described by Psi-induced changes in the density and molecular orientation of ions in the molecular layer closest to the electrode. Our results suggest that the addition of Li+ induces disorder in the EDL, which originates from the strong binding of anions to Li+. An in-depth analysis of the distribution of Li+ in the EDL reveals that it does not readily enter the molecular layer at the electrode surface, preferring instead to be localized farther away from the surface in the second molecular layer. This behavior is validated through an analysis of the free energy of Li+ solvation as a function of distance from the electrode. Free energy wells are found to coincide with localized concentrations of Li+, the depths of which increase with Psi and suggest a source of impedance for Li+ to reach the electrode.

Haskins, Justin B.↗

Silicon micromachined accelerometer/seismometer and method of making the same

A silicon-based microaccelerometer for seismic application is provided using a low-resonant frequency (10 Hz), large proof mass (1 gram), and high Q suspension to achieve high sensitivity of less than 1 ng with a bandwidth a 0.05 to 50 Hz. The proof mass is cut away from a planar substrate in the form of a disk using abrasive cutting, which disk closely fits but does not touch a surrounding angular frame. The spring of the microaccelerometer between the angular frame and the proof mass is provided from two continuous, 3 microns thick membranes. The fixed capacitive electrodes are provided on separate, subsequently bonded substrates, and movable capacitive plates are provided on the membranes. By fabricating capacitive plates on the separate substrates, the gap between the fixed and movable capacitive plates in the differential capacitive sensor is closely controlled. The use of continuous membranes for the spring produces a shock resistant, robust sensor.

Martin, Richard D.↗

Interfacial Structure and Capacitance of Li-doped Ionic Liquid Electrolytes from Molecular Simulations

Ionic liquids have been proposed as candidate electrolytes for high-energy density, rechargeable batteries, supercapacitors, and hybrid energy storage devices. Though Li-salt is often present in these systems, its influence on interfacial properties is largely uncharacterized. We, thereby, present an extensive computational analysis, supported by experimental comparisons, of the properties of a representative set of these electrolytesat an ideal carbon interface as a function of Li-salt doping and voltage. We have performed polarizable molecular (MD) dynamics simulations, using the APPLEP force field, to evaluate electric double layer (EDL) capacitance and distribution of Li+ in the EDL. Differential capacitance exhibits the characteristic camel profile and is insensitive to Li-doping. Li+ localizes in the second molecular layer of the EDL, which is a result of confinement from free energy barriers associated with ion layering. Joint MDelectronic structure computations show the electrochemical window of the electrolytes to be a weak function of Li-doping. Estimates of supercapacitor specific energy are made using the computed window and capacitance. The magnitude and trends in specific energy are in good agreement with experiment.

batteries↗

High Temperature Capacitive Strain Gage

Capacitive strain gages designed for measurements in wind tunnels to 2000 F were built and evaluated. Two design approaches were followed. One approach was based on fixed capacitor plates with a movable ground plane inserted between the plates to effect differential capacitive output with strain. The second approach was based on movable capacitor plates suspended between sapphire bearings, housed in a rugged body, and arranged to operate as a differential capacitor. A sapphire bearing gage (1/4 in. diameter x 1 in. in size) was built with a range of 50,000 and a resolution of 200 microstrain. Apparent strain on Rene' 41 was less than + or - 1000 microstrain from room temperature to 2000 F. Three gage models were built from the Ground Plane Differential concept. The first was 1/4 in. square by 1/32 in. high and useable to 700 F. The second was 1/2 in. square by 1/16 in. high and useable to 1440 F. The third, also 1/2 in. square by 1/16 in. high was expected to operate in the 1600 to 2000 F range, but was not tested because time and funding ended.

Wnuk, Stephen P., Jr.↗

Correlation of photocurrent-voltage curves with flat-band potential for stable photoelectrodes for the photoelectrolysis of water

Using the differential capacitance technique, the flat-band potential of n-type TiO2, SnO2, SrTiO3, KTaO3, and KTa(0.77)Nb(0.23)O3 electrodes has been determined as a function of pH in aqueous electrolytes. Plots of flat-band potential vs. pH are linear in all cases and have a slope of approximately 0.059 V/pH unit. The flat-band potential correlates nicely with the onset for photoanodic currents corresponding to O2 evolution at the n-type semiconductor and H2 at the dark Pt cathode. The ordering of flat-band potentials at a given pH is SrTiO3 of the order of KTaO3 of the order of KTa(0.77)Nb(0.23)O3 greater than TiO2 greater than SnO2 (SnO2 most positive vs a saturated calomel electrode).

Bolts, J. M.↗

Two-degree-of-freedom image motion compensator for Shuttle-based pointing experiments

The mechanical design of the subarcsec-accurate, high-bandwidth two-DOF image motion compensator developed to enhance Space Shuttle-based optical telescope experiments' pointing accuracy encompasses a gimbal-type flex-pivot suspension, a novel ironless two-axis forcer, and a differential capacitive tilt-sensor system. The image motion compensator was developed to allow the UV Imaging Telescope Sensor to maintain stringent pointing accuracies over extended integration intervals while experiencing typical manned spacecraft perturbations.

Schuster, Ludwig E.↗

Surface Micro-Machining: Progress Towards Micro-Electro Mechanical Systems

Surface micromachining is a technique for building electromechanical systems in silicon. A number of electromechanical systems have been implemented in miniature using the fundamental structural building blocks of tensile and non-tensile springs, differential capacitance sensing cells, and electrostatic drive. The integration of complicated mechanical structures and electrical circuits onto a single chip is expected to improve reliability and testability of systems. Reduction in interconnect wiring, the increased use of automation, and the inherent reliability of integrated circuits will all contribute to increased reliability of systems.

Doscher, James↗

Analysis of differential and active charging phenomena on ATS-5 and ATS-6

Spacecraft charging on the differential charging and artificial particle emission experiments on ATS 5 and ATS 6 were studied. Differential charging of spacecraft surfaces generated large electrostatic barriers to spacecraft generated electrons, from photoemission, secondary emission, and thermal emitters. The electron emitter could partially or totally discharge the satellite, but the mainframe recharged negatively in a few 10's of seconds. The time dependence of the charging behavior was explained by the relatively large capacitance for differential charging in comparison to the small spacecraft to space capacitance. A daylight charging event on ATS 6 was shown to have a charging behavior suggesting the dominance of differential charging on the absolute potential of the mainframe. Ion engine operations and plasma emission experiments on ATS 6 were shown to be an effective means of controlling the spacecraft potential in eclipse and sunlight. Elimination of barrier effects around the detectors and improving the quality of the particle data are discussed.

Olsen, R. C.↗

Strain Gage Measurement System to Determine Cryogenic Propellant Tank Level

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult proposition. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. This paper describes a simple, but effective method to determine propellant volume by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a very good quality signal even during pressurization.

Figueroa, Fernando↗

Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.

Figueroa, Fernando↗

Capacitance multiplier and filter synthesizing network

A circuit using a differential amplifier multiplies the capacitance of a discrete interating capacitor by (r sub 1 + R sub 2)/R sub 2, where R sub 1 and R sub 2 are values of discrete resistor coupling an input signal e sub 1 of the amplifier inputs. The output e sub 0 of the amplifier is fed back and added to the signal coupled by the resistor R sub 2 to the amplifier through a resistor of value R sub 1. A discrete resistor R sub x may be connected in series for a lag filter, and a discrete resistor may be connected in series with the capacitor for a lead-lag filter. Voltage dividing resistors R sub a and R sub b may be included in the feedback circuit of the amplifier output e sub o to independently adjust the circuit gain e sub i/e sub o.

Kline, A. J.↗

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗

Packaging Technologies for 500C SiC Electronics and Sensors

Various SiC electronics and sensors are currently under development for applications in 500C high temperature environments such as hot sections of aerospace engines and the surface of Venus. In order to conduct long-term test and eventually commercialize these SiC devices, compatible packaging technologies for the SiC electronics and sensors are required. This presentation reviews packaging technologies developed for 500C SiC electronics and sensors to address both component and subsystem level packaging needs for high temperature environments. The packaging system for high temperature SiC electronics includes ceramic chip-level packages, ceramic printed circuit boards (PCBs), and edge-connectors. High temperature durable die-attach and precious metal wire-bonding are used in the chip-level packaging process. A high temperature sensor package is specifically designed to address high temperature micro-fabricated capacitive pressure sensors for high differential pressure environments. This presentation describes development of these electronics and sensor packaging technologies, including some testing results of SiC electronics and capacitive pressure sensors using these packaging technologies.

Chen, Liang-Yu↗