Search NASASearch

SEARCH · Search NASA

Results for “dynamic voltage support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION

Hybrid Modeling of Three-Phase Grid-Supporting Inverters for Dynamic Studies

Grid technologies connected by power electronic converter (PEC) interfaces continually implement grid support functions mandated by grid codes and standards. The transition to converter-based generation demands precise PEC models to assess system dynamics, which have been previously overlooked in conventional power systems. This study proposes a hybrid method for analyzing grid-connected three-phase PEC dynamics with the IEEE standard 1547-2018 Volt-VAr mode that combines physics and data-driven techniques. The physics model reflects the PEC’s internal behavior, whereas the data-driven modeling technique evaluates the grid-supporting capabilities of the smart PEC. The system identification approach is used to generate dynamic PEC models based on changing grid voltage and measured current injected into the grid by the PEC. In the Volt-VAr support mode, a detailed topological model including switches is utilized to compare the goodness-of-fit of the extracted hybrid dynamic model. The results demonstrate that the hybrid PEC model in the Volt-VAr mode accurately matches the dynamics with the topological model.

Subedi, Sunil

Voltage cycling as a dynamic operation mode for high temperature electrolysis solid oxide cells

Solid Oxide Electrolysis Cells (SOECs) have emerged as a promising technology for the efficient production of H2 via high-temperature electrolysis. However, power input from dynamic energy sources remains a significant challenge for their long-term stability. It is important to analyze the tolerance of cells under dynamic operation conditions. This study focuses on evaluating the impact of voltage cycling on the performance and durability of electrode-supported SOECs. We explore the operational limits and degradation mechanisms of SOECs subjected to various voltage conditions and find that the cells have high tolerance for dynamic voltage. Voltage cycling between 1.3 V and 1.5 V for 9000 cycles does not damage the cell. Conversely, cycling to higher voltages (≥1.7 V) results in accelerated degradation. Advanced characterization is used to screen for various degradation modes post operation. Within the oxygen electrode, XRD and STEM EDS find compositional and phase evolution in all voltage cycled samples including increased decomposition of the air electrode resulting in cation migration. Microstructural analysis of the fuel electrode from nano-CT data shows minimal change throughout the sample set and no evidence of Ni migration, indicating the fuel electrode is stable and not impacted by cycling to higher voltages within the timeframe studied.

Zhu, Zhikuan

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY

Small-Signal Analysis of Current-Limiting Grid-Forming Inverters

Grid-forming (GFM) inverters are equipped with a current limiter to protect the device during grid disturbances. Because the intervention of the current limiter can compromise the transient stability of the GFM inverter, various types of current limiter designs and additional frequency-stabilization control methods have been proposed in recent literature to aid in transient GFM inverter stability; however, the small-signal stability implications of adding these additional control blocks during, in particular, off-nominal conditions are not fully understood. To address this challenge, this paper presents a generic small-signal model of a GFM inverter that incorporates various types of current limiters and frequency stability-enhancing controls. With the proposed model, we analyze the root causes of inverter instability, which reveals two critical design trade-offs. First, due to current-limiter engagement caused by a disturbance, the GFM inverter dynamics are altered, which can lead to voltage oscillations. Second, additional frequency-stabilization controls can improve the small-signal stability of the GFM inverter, but at the cost of reduced power and voltage support to the grid. Comprehensive hardware experiments validate the theoretical concept and analysis. The findings in this work underscore the importance of incorporating both transient-response and small-signal dynamics requirements into the design procedure of GFM current limiters and frequency-stabilization controls.

24 POWER TRANSMISSION AND DISTRIBUTION

Aggregated DER_A Model Parameterization via Online Moving Horizon Estimation

Here, this paper introduces a methodology for parameterizing the DER_A model using a novel smooth mathematical representation, simplifying the process and preserving accuracy in modeling inverter-based generator (IBG). The methodology employs an online parameterization process that can operate in real-time. The model parameterization process is structured into five sequential steps, each targeting a specific aspect of the DER_A model through moving horizon estimation. This approach adapts to systems with varying voltage and frequency support requirements by selectively applying each step. Simulation results on systems with both known and unknown parameters validate the methodology’s effectiveness. The online moving horizon estimation technique accurately captures the dynamics of the overall system and ensures that the parameterized DER_A model closely mirrors the real system’s voltage, current, and power dynamics. The findings highlight the potential of this methodology to substantially improve and simplify the dynamic modeling of power systems, paving the way for more reliable and robust IBG and grid integration.

42 ENGINEERING

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)

Dynamic Temporal Graph Sequence Data for Resilience-Oriented Distribution Network Reconfiguration

This dataset comprises temporal dynamic graph sequences generated from power grid simulations focused on grid reconfiguration to enhance resilience. The simulations model failure propagation under varying conditions, with nodes assigned distinct failure probabilities. For each time step, the dataset captures the evolution of node states (functional or failed) and features critical to grid operations, such as pv_output, load_profile, load_dispatch, dg_output, loss, and voltage. Node types include sources, normal loads, and nodes with specific equipment like PVs, micro turbines, or shunt capacitors. The dataset is structured to support the training of dynamic graph neural networks, facilitating research on node feature prediction and edge dynamics under failure scenarios. Three distinct configurations are included, providing a robust foundation for modeling power grid resilience.

29 ENERGY PLANNING, POLICY, AND ECONOMY

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION

thevenin: An Equivalent Circuit Modeling Package [SWR-24-132]

This package is a wrapper for the well-known Thevenin equivalent circuit model for simulating battery behavior with a focus on ease of use. The model is comprised of a single series resistor followed by any number of parallel RC pairs. The package includes an intuitive "experiment" interface, which simplifies the programming of constant or dynamic current, voltage, and/or power-driven loads, making it ideal for a wide range of applications, from basic tests to complex simulations. It also supports state-of-charge (SOC) and temperature-dependent properties, allowing the model to be more easily calibrated against real cells.

Randall, Corey

ICED: An Integrated CGRA Framework Enabling DFVS-Aware Acceleration

oarse-grained reconfigurable arrays (CGRAs) are a promising solution to enable energy-efficient acceleration of applications from different domains. By leveraging reconfiguration at the functional level, they can adapt to significantly different computational patterns. Existing CGRA mapping approaches extract instruction-level parallelism, exploit loop-pipelining opportunities, guarantee the data dependency, and target high throughput of a given loop. However, the recurrence data-dependency in the DFG and the mismatch between required and available computing/communication resources complicate the mapping, and might lead to significant unbalances in the utilization of the CGRA's tiles. This results in wasted power for tiles with low utilization. Applying dynamic voltage and frequency scaling (DVFS) can potentially solve this challenge and improve energy efficiency by adjusting voltage and frequency of different tiles independently. CGRAs have also been successful in accelerating data-dependent streaming applications. However, in these applications, the execution time of each kernel in the pipeline might dynamically vary depending on the characteristics of the input. This also leads to under-utilization of resources for the dynamically changing kernels that do not limit the application throughput. DVFS can also improve energy efficiency for these applications by dynamically changing the voltage and frequency levels of tiles that host non performance-constraining kernels. This paper proposes ICEDTEA -- an integrated DVFS-aware framework to map applications on CGRAs that support power islands. ICEDTEA proposes a CGRA architecture supporting DVFS islands at varying granularity (from a single tile to a group of tiles) and the related DVFS-aware compilation and mapping toolchain. ICEDTEA is the first work that introduces DVFS support for spatio-temporal CGRAs at power-island levels. The experimental evaluation shows that ICEDTEA improves average utilization by 2.3$\times$ and energy-efficiency by 1.32$\times$ over a conventional CGRA. With streaming applications, ICEDTEA improves energy efficiency by 1.12$\times$ over a state-of-the-art CGRA that introduces partial dynamic reconfiguration to adapt to variations in kernels' throughput.

Tan, Cheng

MCP-eGridGPT (MCP-Enabled Chatbot with Electrical Power System Analysis and Interactive Visualization Tool) [SWR-25-126]

This software is an advanced chatbot system that integrates the Model Context Protocol (MCP) to provide intelligent electrical power system analysis and automated visualization generation. The system enables users to interact with complex electrical engineering tools through natural language, automatically analyzes power system data for voltage violations and grid health assessment, and generates professional interactive HTML dashboards and reports. Key features include dynamic tool discovery from MCP servers, multi-LLM provider support, intelligent data interpretation using large language models, automated chart generation, and a web-based interface for real-time analysis. The software bridges sophisticated electrical engineering analysis with user-friendly interfaces, making power system diagnostics accessible through conversational AI.

Choi, Seong [National Laboratory of the Rockies (N

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting

Summary of GFL Inverter Capability and Performance: Malawi [Slides]

This presentation provides a comprehensive comparison of inverter-based resource (IBR) technical requirements across multiple international grid codes - including IEEE 2800, ESO, EirGrid, and Malawi's evolving regulatory framework - to support capacity building for electricity-sector institutions in Malawi. It highlights key performance expectations for grid-following (GFL) inverters across critical domains such as primary and fast frequency response, ramping behavior, frequency and voltage ride-through capabilities, reactive power and voltage control, ROCOF withstand, phase jump tolerance, system strength considerations, protection schemes, and dynamic modeling requirements. Emphasizing a "Do no harm, do something, do more" philosophy, the document synthesizes best practices and operational benchmarks to guide the integration and stability of inverter-based resources within Malawi's power system. The presentation forms part of the SABESS Center of Excellence initiative supported by the Global Energy Alliance for People and the Planet.

24 POWER TRANSMISSION AND DISTRIBUTION

Flat nonlinear optics with intersubband polaritonic metasurfaces

Nonlinear intersubband polaritonic metasurfaces produce some of the strongest second- and third-order nonlinear optical responses reported for condensed matter systems at infrared frequencies. These metasurfaces are fabricated as two-dimensional arrays of nanoresonators from multi-quantum-well semiconductor heterostructures, designed to produce strong nonlinear responses associated with intersubband transitions. By optimally coupling the optical modes of the nanoresonators to vertically polarized intersubband transitions in semiconductor heterostructures, one can boost the nonlinear response associated with intersubband transitions, make intersubband transitions interact with free-space radiation at normal incidence, and hence produce optically thin flat nonlinear optical elements compatible with free-space optical setups. As a result of the strong nonlinear response in these systems, significant nonlinear conversion efficiencies (>0.1 %) can be attained in deeply subwavelength optical films using modest pumping intensities of only 10–100 kW/cm 2 . Subwavelength metasurface thickness relaxes phase-matching constraints limiting the operation of bulk nonlinear crystals. Furthermore, the amplitude and phase of the nonlinear optical response in intersubband polaritonic metasurfaces can be tailored for a specific pump wavelength and a nonlinear process of interest through the co-optimization of quantum engineering of electron states in semiconductor heterostructures and photonic engineering of the metasurface nanoresonators design. Additionally, an applied voltage can dynamically control the amplitude and phase of the nonlinear optical response at a nanoresonator level. Here, we review the current state of the art in this rapidly expanding field, focusing on nonlinear processes supporting second-harmonic generation, saturable absorption, and optical power limiting.

flat optics