Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficiency measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Photoreceiver efficiency measurements

The efficiency and other related parameters of Smithsonian Astrophysical Observatory's four laser receivers were measured at the observing stations by oscilloscope photography. If the efficiency is defined as the number of photoelectrons generated by the photomultiplier tube divided by the number of photons entering the aperture of the receiver, its measured value is about 1% for the laser wavelength of 694 nm. This value is consistent with the efficiency computed from the specified characteristics of the photoreceiver's optical components.

Lehr, C. G.↗

Collection efficiency measurements for solar cell research

A system was established for measuring absolute, spectral collection efficiency that is well suited to solar cell research and development. Determination of spectral collection efficiency involves measurements of the incident photon intensity, the device reflection coefficient, and the cell short circuit current. A monochromatic photon flux is obtained with a high intensity Bausch and Lomb monochromator, and an Epply thermopile detector is used to measure incident intensity. Normal incidence reflectivity measurements are achieved with a prism type beam splitter. The experimental approach is discussed, measurements of the reflectivity of evaporated silver films are considered. Collection efficiency measurements of silicon solar cells are presented, and collection efficiency studies of Cu20 solar cells are discussed.

Hampton, H. L.↗

Correlation of rheological characteristics of lubricants with transmission efficiency measurements

The power efficiency of a helicopter transmission has been analyzed for 11 lubricants by looking at the Newtonian and non-Newtonian properties of the lubricants. A non-Newtonian property of the lubricants was the limiting shear strength proportionality constant. The tests were performed on a high-pressure, short-time shear strength analyzer. A power efficiency formula that was obtained by analyzing the Newtonian and non-Newtonian properties of the lubricants is presented in detail.

Jacobson, B. O.↗

Efficiency measurement techniques for calibration of a prototype 34-meter-diameter beam-waveguide antenna at 8.45 and 32 GHz

Efficiency measurements at 8.45 and 32 GHz (X and Ka bands, respectively) were carried out on the new 34 m diameter beam waveguide antenna now in use at the NASA Goldstone Deep Space Communications Complex. The use of portable test packages enabled measurements at both the Cassegrain and beam waveguide focal points. Radio sources (quasars and Venus) were used as calibrators, and updated determinations of flux and source size correction were made during the period of the measurements. Gain and efficiency determinations as a function of elevation angle are presented, and the effects of the beam waveguide system and antenna structure are clearly seen. At the beam waveguide focus, an 8.45 GHz peak efficiency of 72.38 pct was measured; at 32 GHz, 44.89 pct was measured.

Slobin, Stephen D.↗

Quantum efficiency measurements for several waveshifter coatings in the extreme vacuum ultraviolet

Quantum efficiency measurements are given for coronene and liumogen coatings designed to enhance UV sensitivity for silicon charge coupled device imaging detectors. Coatings on quartz and on UDT PIN 10DP photodiodes were tested. The wavelength range extended from 153.7 to 50.0 nm in the vacuum ultraviolet. Similar measurements were made for coronene, liumogen, and stilbene-3 laser dye films on quartz disks relative to sodium salicylate. Sodium salicylate and coronene are the most efficient waveshifters down to 50 nm so far observed. Coronene's fairly constant quantum efficiency over such a wide wavelength range into the far VUV makes it a useful waveshifter for UV and VUV applications.

Butner, C. L.↗

Radiated microwave power transmission system efficiency measurements

The measured and calculated results from determining the operating efficiencies of a laboratory version of a system for transporting electric power from one point to another via a wireless free space radiated microwave beam are reported. The system's overall end-to-end efficiency as well as intermediated conversion efficiencies were measured. The maximum achieved end-to-end dc-to-ac system efficiency was 54.18% with a probable error of + or - 0.94%. The dc-to-RF conversion efficiency was measured to be 68.87% + or - 1.0% and the RF-to-dc conversion efficiency was 78.67 + or - 1.1%. Under these conditions a dc power of 495.62 + or - 3.57 W was received with a free space transmitter antenna receiver antenna separation of 170.2 cm (67 in).

Dickinson, R. M.↗

Efficiency measurements of reflection gratings in the 100-300-A band

Zero-order and first-order efficiencies of plane diffraction grazings over the 100-300-A band have been measured using the NRL beamline facility at the National Synchrotron Light Source. Measurements were taken at grating angles of 5, 10, and 15 deg, and the incident radiation was polarized primarily in the transverse magnetic mode. Four (three laminar, one blazed) of the gratings were ion etched in high quality quartz blanks, overcoated with 200 A of gold. A fifth (blazed) grating was ruled in gold. The line densities are 1000, 2000, and 3600 grooves/mm for those with laminar profiles. Both blazed gratings have a blaze angle of 8 deg and line densities of 3600 grooves/mm. Measured first-order efficiencies up to 15 percent were obtained for the laminar gratings and up to 8 percent was obtained for the ion-etched blazed grating. Much lower efficiencies (not greater than 2 percent) were measured for the ruled grating. A computer program was written to calculate grating efficiencies using a full electromagnetic model. Measured efficiencies of the ion-etched gratings agree well with predicted values, but the measured first-order efficiency of the ruled grating is much lower than predicted.

Meekins, John F.↗

A single user efficiency measure for evaluation of parallel or pipeline computer architectures

A precise statement of the relationship between sequential computation at one rate, parallel or pipeline computation at a much higher rate, the data movement rate between levels of memory, the fraction of inherently sequential operations or data that must be processed sequentially, the fraction of data to be moved that cannot be overlapped with computation, and the relative computational complexity of the algorithms for the two processes, scalar and vector, was developed. The relationship should be applied to the multirate processes that obtain in the employment of various new or proposed computer architectures for computational aerodynamics. The relationship, an efficiency measure that the single user of the computer system perceives, argues strongly in favor of separating scalar and vector processes, sometimes referred to as loosely coupled processes, to achieve optimum use of hardware.

Jones, W. P.↗

Quantum efficiency measurements of Tektronix backside thinned CCDs

Results are presented of a program in progress to produce CCDs with high stable quantum efficiency (QE). Measurements made at 253.7 nm over a six-month period showed no significant QE difference between two CCDs manufactured in 1989 and one manufactured in 1988. QE improvement by the addition of a two-layer antireflection coating is about threefold at 400 nm.

Delamere, Alan↗

MIL-M-38510/470 test vectors: Fault detection efficiency measurement via hardware fault simulation

The stuck fault detection efficiency of the test vectors developed for the MIL-M-38510/470 NASA was measured using a hardware stuck fault simulator for the 1802 microprocessor. Thirty-nine stuck faults were not detected out of a total of 874 injected into the combinatorial and sequential parts of the microprocessor. Since undetected faults can create catastrophic errors in equipment designed for high reliability applications, it is recommended that the MIL-M-38510/470 NASA be enhanced with additional test vectors so as to achieve 100% stuck fault detection efficiency.

Timoc, C. C.↗

Transmission Efficiency Measurements and Correlations with Physical Characteristics of the Lubricant

Data from helicopter transmission efficiency tests were compared to physical properties of the eleven lubricants used in those tests. The tests were conducted with the OH-58 helicopter main rotor transmission. Efficiencies ranged from 98.3 to 98.8 percent. The data was examined for correlation of physical properties with efficiency. There was a reasonable correlation of efficiency with absolute viscosity if the viscosity was first corrected for temperature and pressure in the lubricated contact. Between lubricants, efficiency did not correlate well with viscosity at atmospheric pressure. Between lubricants, efficiency did not correlate well with calculated lubricant film forming capacity. Bench type sliding friction and wear measurements could not be correlated to transmission efficiency and component wear.

Coy, J. J.↗

Considerations for high accuracy radiation efficiency measurements for the Solar Power Satellite (SPS) subarrays

The relatively large apertures to be used in SPS, small half-power beamwidths, and the desire to accurately quantify antenna performance dictate the requirement for specialized measurements techniques. Objectives include the following: (1) For 10-meter square subarray panels, quantify considerations for measuring power in the transmit beam and radiation efficiency to + or - 1 percent (+ or - 0.04 dB) accuracy. (2) Evaluate measurement performance potential of far-field elevated and ground reflection ranges and near-field techniques. (3) Identify the state-of-the-art of critical components and/or unique facilities required. (4) Perform relative cost, complexity and performance tradeoffs for techniques capable of achieving accuracy objectives. the precision required by the techniques discussed below are not obtained by current methods which are capable of + or - 10 percent (+ or - dB) performance. In virtually every area associated with these planned measurements, advances in state-of-the-art are required.

Kozakoff, D. J.↗

Consideration for high accuracy radiation efficiency measurements for the Solar Power Satellite (SPS) subarrays

The transmit beam and radiation efficiency for 10 metersquare subarray panels were quantified. Measurement performance potential of far field elevated and ground reflection ranges and near field technique were evaluated. The state-of-the-art of critical components and/or unique facilities required was identified. Relative cost, complexity and performance tradeoffs were performed for techniques capable of achieving accuracy objectives. It is considered that because of the large electrical size of the SPS subarray panels and the requirement for high accuracy measurements, specialized measurement facilities are required. Most critical measurement error sources have been identified for both conventional far field and near field techniques. Although the adopted error budget requires advances in state-of-the-art of microwave instrumentation, the requirements appear feasible based on extrapolation from today's technology. Additional performance and cost tradeoffs need to be completed before the choice of the preferred measurement technique is finalized.

Kozakoff, D. J.↗

Charge transfer efficiency measurements at low signal levels on STIS/SOHO TK1024 CCD's

Charge transfer efficiency (CTE) test methods are reviewed, and the results and conclusions of the tests are given. The test methods have been utilized to describe the CTE characteristics of the Tektronix 1024 by 1024 CCD to optimize low dark current, low readout noise, and high CTE at low signal levels. CTE modelling is described, and three test methods are set forth and compared. The Fe-55 X-ray response method utilizes the response of a CCD to X-ray photons from the radioactive source Fe-55. The extended pixel edge response method employs the measurement of the charge lost to successive pixels by a known initial signal as it is shifted through the array. The charge injection method consists of charge injection through the output amplifier reset transistor. These measurements were performed on several devices with known CTEs. The CTEs are found to be in agreement for the three methods, making application and test requirements the principal criteria for their use.

Orbock, J. D.↗

AM0 efficiency measurements

Procedures for measuring the air mass zero (AM0) current versus voltage characteristics and calculating the efficiency are discussed. The various factors influencing the determination of the efficiency include the I-V measurement system, reference cell calibration, standard reporting conditions, area measurement, light source characteristics, temperature measurement and control, and the measurement procedures. Each of these sources contributes to the precision index and bias limit which is combined to obtain the total uncertainty in the efficiency. These factors are discussed as well as how to minimize differences in the reported AM0 efficiency of a given PV cell between various laboratories.

Emery, Keith↗

Comparison of measured efficiencies of nine turbine designs with efficiencies predicted by two empirical methods

Empirical methods of Ainley and Kochendorfer and Nettles were used to predict performances of nine turbine designs. Measured and predicted performances were compared. Appropriate values of blade-loss parameter were determined for the method of Kochendorfer and Nettles. The measured design-point efficiencies were lower than predicted by as much as 0.09 (Ainley and 0.07 (Kochendorfer and Nettles). For the method of Kochendorfer and Nettles, appropriate values of blade-loss parameter ranged from 0.63 to 0.87 and the off-design performance was accurately predicted.

FLOW-TURBINES↗