Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric resistance heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Itinerant G-type antiferromagnet SrCr 2 As 2 studied by magnetization, heat capacity, electrical resistivity, and NMR measurements

Here, the physical properties of itinerant antiferromagnetic (AFM) SrCr 2 As 2 with body-centered tetragonal ThCr 2 Si 2 structure were investigated in single crystalline and polycrystalline forms by electrical resistivity ρ, heat capacity C p , magnetic susceptibility χ versus temperature T, and magnetization M versus applied magnetic field H isotherm measurements as well as 75 As and 53 Cr nuclear magnetic resonance (NMR) measurements in the wide temperature range T = 1.6–900 K. From the χ(T) and 75 As NMR measurements, the G-type AFM state below T N = 615(15) K has been determined, consistent with the previous neutron-diffraction measurements. Direct evidence of magnetic ordering of the Cr spins was shown by the observation of the 53 Cr NMR spectrum under H = 0. From the χ( T) measurements on single-crystal SrCr 2 As 2 under the two different magnetic field directions H|| ab and H || c in the AFM state, the Cr ordered moments are shown to align along the c axis in the G-type AFM state. The metallic state is directly evidenced by the ρ, C p , and NMR measurements, and the density of states at the Fermi energy $\mathscr{D}$(E F ) in the AFM state is estimated to be 7.53 states/eV f.u. for both spin directions which is almost twice the bare $\mathscr{D}$(E F ) estimated from first-principles calculations, suggesting an enhancement of the conduction-carrier mass by a factor of two in the AFM state. The $\mathscr{D}$(E F ) is found to be nearly constant below at least 100 K and is independent of H. The ρ(T) is found to show T-linear behavior above T N and exhibits positive curvature below T N where significant loss of spin-disorder scattering upon magnetic ordering is observed. The resistivity anisotropy of the compound remains moderate ρ c /ρ a ~ 9 through most of the magnetically ordered phase but shows a rapid increase below 50 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bench-Scale Development of a Novel Direct Air Capture Technology Using High-Capacity Structured Sorbents

The work performed under this project has resulted into development of a DAC technology utilizing a structured sorbent to capture CO 2 from ambient air with a key innovation of direct Joule heating of the sorbent for CO 2 desorption. A working SMA, fully integrated with an electrically resistive heating layer, high surface area support, and high CO 2 capacity sorbent coated onto a commercial ceramic monolithic substrate, was successfully developed and demonstrated over >200 adsorption-desorption cycles in a high-fidelity bench test unit directly using ambient air. A cordierite-based monolith was selected as a substrate owing to its high surface area, low bulk density, low heat capacity, and commercial availability. Reaction kinetics study conducted during this project led to development of a promoter for the base Na 2 CO 3 sorbent that could be incorporated into the sorbent to enhance to achieve higher CO 2 adsorption/desorption rates, greater working capacity, and reduced regeneration temperature. An accelerated aging study was conducted in a TGA to determine sorbent stability and no degradation in the sorbent performance was observed even after 250 adsorption-desorption cycles. An electrically resistive heating layer was developed with tunable electrical properties. The heating layer was coated onto the selected cordierite substrate. Aging studies performed showed the electrical properties and heating performance was stable after 500 heating and cooling cycles. The collective findings on the selected cordierite substrate, robust heating layer, promoter and sorbent selection were used to synthesize a full, 6”x6” SMA for bench-scale testing. The bench-scale DAC system was constructed to test full size SMAs using real ambient air for adsorption and joule heating for regeneration. After completing shakedown and commissioning of the 1 kg/day of CO 2 capacity DAC bench unit, an extended operation was performed to complete over 230 cycles with the full size SMA. This testing showed no observable degradation in sorbent performance. A detailed process model, TEA and LCA were developed for a conceptual 100,000 TPY CO 2 removal DAC facility. The LCA results show the net CO 2 e emissions from the DAC system are highly dependent on the electricity source. All other factors, including SMA manufacturing, materials for facility enclosure, etc., are minor cost contributors compared to the energy consumption required for CO 2 removal. With the successful development and validation of the SMA for the sustained performance for CO 2 removal from ambient air with joule heated regeneration in this project, a fully integrated 1 TPY bench-scale DAC system is currently in development with the support of DOE/FECM (DE-FE0032243). The project objective is to demonstrate the engineering design of the DAC system to produce a continuous, high purity CO 2 stream from ambient air. This project will address and validate key engineering features of the DAC system including the gas sealing mechanism and panels, enclosure and air contactor design, and automation sequence to achieve continuous CO 2 production.

42 ENGINEERING↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Catalytic Microtube Rocket Igniter

Devices that generate both high energy and high temperature are required to ignite reliably the propellant mixtures in combustion chambers like those present in rockets and other combustion systems. This catalytic microtube rocket igniter generates these conditions with a small, catalysis-based torch. While traditional spark plug systems can require anywhere from 50 W to multiple kW of power in different applications, this system has demonstrated ignition at less than 25 W. Reactants are fed to the igniter from the same tanks that feed the reactants to the rest of the rocket or combustion system. While this specific igniter was originally designed for liquid methane and liquid oxygen rockets, it can be easily operated with gaseous propellants or modified for hydrogen use in commercial combustion devices. For the present cryogenic propellant rocket case, the main propellant tanks liquid oxygen and liquid methane, respectively are regulated and split into different systems for the individual stages of the rocket and igniter. As the catalyst requires a gas phase for reaction, either the stored boil-off of the tanks can be used directly or one stream each of fuel and oxidizer can go through a heat exchanger/vaporizer that turns the liquid propellants into a gaseous form. For commercial applications, where the reactants are stored as gases, the system is simplified. The resulting gas-phase streams of fuel and oxidizer are then further divided for the individual components of the igniter. One stream each of the fuel and oxidizer is introduced to a mixing bottle/apparatus where they are mixed to a fuel-rich composition with an O/F mass-based mixture ratio of under 1.0. This premixed flow then feeds into the catalytic microtube device. The total flow is on the order of 0.01 g/s. The microtube device is composed of a pair of sub-millimeter diameter platinum tubes connected only at the outlet so that the two outlet flows are parallel to each other. The tubes are each approximately 10 cm long and are heated via direct electric resistive heating. This heating brings the gasses to their minimum required ignition temperature, which is lower than the auto-thermal ignition temperature, and causes the onset of both surface and gas phase ignition producing hot temperatures and a highly reacting flame. The combustion products from the catalytic tubes, which are below the melting point of platinum, are injected into the center of another combustion stage, called the primary augmenter. The reactants for this combustion stage come from the same source but the flows of non-premixed methane and oxygen gas are split off to a secondary mixing apparatus and can be mixed in a near-stoichiometric to highly lean mixture ratio. The primary augmenter is a component that has channels venting this mixed gas to impinge on each other in the center of the augmenter, perpendicular to the flow from the catalyst. The total crosssectional area of these channels is on a similar order as that of the catalyst. The augmenter has internal channels that act as a manifold to distribute equally the gas to the inward-venting channels. This stage creates a stable flame kernel as its flows, which are on the order of 0.01 g/s, are ignited by the combustion products of the catalyst. This stage is designed to produce combustion products in the flame kernel that exceed the autothermal ignition temperature of oxygen and methane.

Schneider, Steven J.↗

Heated tool for autoclaves

Components made of composite materials are heated in autoclaves by employing electrical resistance heating blankets, thus avoiding need to heat entire autoclave volume. Method provides not only significant energy savings compared to heating entire pressure vessel but offers time savings in accelerated heat-up and cool-down cycles.

Serafini, T. T.↗

Electrically Conductive Amine Functionalized Reduced Graphite Oxide Foam for CO 2 Removal from the Air

Rapid regeneration of CO 2 adsorbents is critical to improving the productivity of direct air capture (DAC) systems. In this study, we codesigned a material to have appropriate electrical conductivity and CO 2 adsorption properties to enable efficient CO 2 capture from air. Specifically, we present a poly(ethylenimine) (PEI)-impregnated thermally annealed graphite oxide (TAGO900) foam adsorbent tailored for vacuum-assisted electrically driven thermal swing adsorption (V-ETSA). This structured adsorbent leverages the high electrical conductivity of the reduced graphite oxide framework to enable fast and direct heating of the adsorbent material by electrical resistance heating (Joule heating). An optimal sample, 40 wt % PEI (molecular weight 25k) impregnated TAGO900, shows the best balance between adsorption capacity (1.54 mmol g –1 ) and adsorption rates (0.016 mmol g –1 min –1 ) using fixed bed breakthrough experiments at 25 °C and 70% RH using 50 sccm 400 ppm of CO 2 /N 2 flow. Compared to conventional temperature vacuum swing adsorption (TVSA), the V-ETSA approach achieves substantially faster CO 2 desorption, achieving average desorption rates (including cooling time) of 0.09 mmol g –1 min –1 ─approximately 2.5 times faster than TVSA under similar operating conditions. The maximum desorption rate reaches 0.23 mmol/g/min during the desorption stage. These results underscore the importance of the direct heating strategy, such as Joule heating, for fast and highly productive vacuum swing adsorption in DAC systems.

amines↗

Retrofit energy conservation in residential buildings in southern California

The common energy conservation techniques (ECTs) that can be retrofit-installed into residential buildings are surveyed. The quantity of saved energy for heating and cooling attributable to each ECT is evaluated for three common modes of heating: natural gas heating at 60/therm; heating via heat pump at $1.20/therm; and electric resistance heating at $2.40/therm. In every case, a life cycle cost comparison is made between the long term revenue due to energy conservation and a safe and conventional alternative investment that might be available to the prudent homeowner. The comparison between investment in an ECT and the alternative investment is brought into perspective using the life cycle payback period and an economic Figure of Merit (FOM). The FOM allows for relative ranking between candidate ECTs. Because the entire spectrum of winter heating climates in California is surveyed, the decision maker can determine whether or not a considered ECT is recommended in a given climate, and under what conditions an ECT investment becomes attractive.

Turner, R. H.↗

Investigation of the thermophysical properties of high-melting materials with the aid of a complex of instruments

The evaporation rate, vapor pressure, heats of evaporation reaction (sublimation, dissociation), enthalpy, electrical resistance, heat capacity, emissivity, and heat conductivity of various carbides, borides, sulfides, nitrides, selenides, and phosphides were investigated. A set of high temperature high vacuum devices, calorimeters (designed for operation at 400 to 1300 K and from 1200 K), and mass spectrometers, most of which were specially developed for these studies, is described.

Bolgar, A. S.↗

Self-regulating proportionally controlled heating apparatus and technique

A self-regulating proportionally controlled heating apparatus and technique is provided wherein a single electrical resistance heating element having a temperature coefficient of resistance serves simultaneously as a heater and temperature sensor. The heating element is current-driven and the voltage drop across the heating element is monitored and a component extracted which is attributable to a change in actual temperature of the heating element from a desired reference temperature, so as to produce a resulting error signal. The error signal is utilized to control the level of the heater drive current and the actual heater temperature in a direction to reduce the noted temperature difference. The continuous nature of the process for deriving the error signal feedback information results in true proportional control of the heating element without the necessity for current-switching which may interfere with nearby sensitive circuits, and with no cyclical variation in the controlled temperature.

Strange, M. G.↗

Windshield-Wiper Heater

Heated blades significantly enhance safety of aircraft and automobiles. Electrical-resistance heating strips inside cover keep wiper blade warmer than freezing temperature. Applies heat directly to windshield wipers, preventing any ice or snow from accumulating on wipers.

Martin, James A.↗

Comparison of Direct Solar Energy to Resistance Heating for Carbothermal Reduction of Regolith

A comparison of two methods of delivering thermal energy to regolith for the carbo thermal reduction process has been performed. The comparison concludes that electrical resistance heating is superior to direct solar energy via solar concentrators for the following reasons: (1) the resistance heating method can process approximately 12 times as much regolith using the same amount of thermal energy as the direct solar energy method because of superior thermal insulation; (2) the resistance heating method is more adaptable to nearer-term robotic exploration precursor missions because it does not require a solar concentrator system; (3) crucible-based methods are more easily adapted to separation of iron metal and glass by-products than direct solar energy because the melt can be poured directly after processing instead of being remelted; and (4) even with projected improvements in the mass of solar concentrators, projected photovoltaic system masses are expected to be even lower.

Muscatello, Anthony C.↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collation of monthly and semiannual reports covering instrumentation at the Decade 80 house in Tucson, Arizona

The Decade 80 solar house, located in Tucson, Arizona, was built to show the use of copper in home building and to demonstrate the use of solar energy to provide space heating and cooling and domestic hot water. The auxiliary energy sources are electrical resistance heating for the domestic hot water and a gas fired boiler for space heating and operation of the absorption air conditioning units. The Semi-Annual report gives an overview of the instrumentation effort with the back-up monthly reports reflecting more detail of the effort that went into the implementation of the data acquisition system.

Source record↗

Instrumentation at the Decade 80 solar house in Tucson, Arizona

Modifications, problems and solutions for the instrumentation system that occurred during the period from May through September, 1978, are described. The solar house was built to show the use of copper in home building and to demonstrate the use of solar energy to provide space heating and cooling and domestic hot water. The auxiliary energy sources are electrical resistance heating for the domestic hot water and a gas-fired boiler for space heating and operation of the adsorption air conditioning units.

Source record↗

Validated model of a thermoelectric heat pump clothes dryer using secondary pumped loops

The energy associated with clothes drying makes up 4% of the total residential electrical energy consumption in the US. The cost is high since most clothes dryers use electric resistance heating which is inexpensive but also energy inefficient. State-of-the-art vapor-compression heat pump clothes dryers offer significant energy savings but have limited market penetration in the US. Here, a new configuration of clothes dryer was studied that utilizes a solid-state thermoelectric heat pump with pumped secondary water loops and conventional fin-and-tube water-to-air heat exchangers. Experimental results are presented for the thermoelectric dryer prototype with a combined energy factor of 6.89 lb BDW /kWh (specific moisture extraction rate of 1.71 kg w /kWh) and a dry time of 84 min for a standard load size of 8.45 lb (3.83 kg) with 57.5% starting moisture content. This is a 85% energy efficiency improvement over baseline electric resistance dryers. The efficiency and drying time results achieved are similar to vapor compression heat pump dryers. Compared to previous air-based thermoelectric clothes dryers, the energy efficiency has been increased by 6%, but drying time has been reduced by as much as 47% using secondary pumped loops and separate heat exchangers, which represents a significant advancement in the technology. In addition to the experimental prototype, a model was also developed to study the performance. The model was validated against experimental prototype data and used to identify the range of performance (dry time and efficiency) that could be expected of the design.

42 ENGINEERING↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗