Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Preparation, Applications, and Digital Simulation of Carbon Interdigitated Array Electrodes

Carbon interdigitated array (IDA) electrodes with features sizes down to 1.2 μm were fabricated by controlled pyrolysis of patterned photoresist. Cyclic voltam-metry of reversible redox species produced the expected steady-state currents. The collection efficiency depends on the IDA electrode spacing, which ranged from around 2.7 to 16.5 μm, with the smaller dimensions achieving higher collection efficiencies of up to 98%. The signal amplification because of redox cycling makes it possible to detect species at relatively low concentrations (10–5 molar) and the small spacing allows detection of transient electrogenerated species with much shorter lifetimes (submillisecond). Digital simulation software that accounts for both the width and height of electrode elements as well as the electrode spacing was developed to model the IDA electrode response. The simulations are in quantitative agreement with experimental data for both a simple fast one electron redox reaction and an electron transfer with a following chemical reaction at the IDAs with larger gaps whereas currents measured for the smallest IDA electrodes, that were larger than the simulated currents, are attributed to convection from induced charge electrokinetic flow. This work was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the Department of Energy, Office of Science Office of Basic Energy Sciences.

Liu, Fei↗

Fabrication of Carbon-Platinum Interdigitated Array Electrodes and Their Application for Investigating Homogeneous Hydrogen Evolution Catalysis

Interdigitated array electrodes (IDAEs) with one carbon electrode and the other platinum electrode were constructed by electrodepositing platinum on one set of the carbon electrodes. Platinum deposition was confirmed by scanning electron microscope (SEM) and cyclic voltammetry. The width of the carbon and platinum digits is less than 2 μm and the gap between two adjacent digits is around 3 μm. The carbon-platinum IDAEs benefit from the characteristics of both carbon and platinum in that carbon can provide a wide nonreactive potential window while platinum is a good catalyst for hydrogen reactions making it useful to characterize the catalytic hydrogen production cycle of the molecular electrocatalyst [Ni(P Ph 2 N Ph 2 ) 2 (CH 3 CN)](BF 4 ) 2 (where P Ph 2 N Ph 2 is 1,3,5,7-tetraphenyl-1,5-diaza-3,7-diphosphacyclooctane). With properly set potentials, the molecular electrocatalyst was reduced at the carbon digits to initiate a homogeneous H 2 production reaction while the platinum digits detect the H 2 by oxidation, providing direct evidence of its production rate from the catalytic cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo

Arrays of electrodes for recording and stimulating the brain are used throughout clinical medicine and basic neuroscience research, yet are unable to sample large areas of the brain while maintaining high spatial resolution because of the need to individually wire each passive sensor at the electrode-tissue interface. To overcome this constraint, we developed new devices that integrate ultrathin and flexible silicon nanomembrane transistors into the electrode array, enabling new dense arrays of thousands of amplified and multiplexed sensors that are connected using fewer wires. We used this system to record spatial properties of cat brain activity in vivo, including sleep spindles, single-trial visual evoked responses and electrographic seizures. We found that seizures may manifest as recurrent spiral waves that propagate in the neocortex. As a result, the developments reported here herald a new generation of diagnostic and therapeutic brain-machine interface devices.

high spatial resolution↗

A microfabricated, 3D-sharpened silicon shuttle for insertion of flexible electrode arrays through dura mater into brain

Electrode arrays for chronic implantation in the brain are a critical technology in both neuroscience and medicine. Recently, flexible, thin-film polymer electrode arrays have shown promise in facilitating stable, single-unit recordings spanning months in rats. While array flexibility enhances integration with neural tissue, it also requires removal of the dura mater, the tough membrane surrounding the brain, and temporary bracing to penetrate the brain parenchyma. Durotomy increases brain swelling, vascular damage, and surgical time. Insertion using a bracing shuttle results in additional vascular damage and brain compression, which increase with device diameter; while a higher-diameter shuttle will have a higher critical load and more likely penetrate dura, it will damage more brain parenchyma and vasculature. One way to penetrate the intact dura and limit tissue compression without increasing shuttle diameter is to reduce the force required for insertion by sharpening the shuttle tip. We describe a novel design and fabrication process to create silicon insertion shuttles that are sharp in three dimensions and can penetrate rat dura, for faster, easier, and less damaging implantation of polymer arrays. Sharpened profiles are obtained by reflowing patterned photoresist, then transferring its sloped profile to silicon with dry etches. We demonstrate that sharpened shuttles can reliably implant polymer probes through dura to yield high quality single unit and local field potential recordings for at least 95 days. On insertion directly through dura, tissue compression is minimal. Significance. This is the first demonstration of a rat dural-penetrating array for chronic recording. This device obviates the need for a durotomy, reducing surgical time and risk of damage to the blood-brain barrier. This is an improvement to state-of-the-art flexible polymer electrode arrays that facilitates their implantation, particularly in multi-site recording experiments. This sharpening process can also be integrated into silicon electrode array fabrication.

60 APPLIED LIFE SCIENCES↗

Numerical Simulation and Modeling of Hydrogen Gas Evolution on Planar and Microwire Array Electrodes

The impact of gas evolution on the electrochemical characteristics of planar electrodes and microwire array electrodes has been analyzed using modeling and simulation. The impacts can mainly be broken into three phenomena: a) a shift in the local reversible hydrogen electrode potential; b) hyperpolarization; and c) an increase in the solution resistance of the electrolyte. The local reversible hydrogen electrode potential shift was found to play the most important role, constituting >40% of the total potential drop between the cathode and reference electrode, following correction for cell resistance. Compared to planar electrodes, a microwire array structure reduces the impact of bubbles on the solution conductance, but the shift in the local reversible hydrogen electrode potential varies with distance from the actual electrode surface.

25 ENERGY STORAGE↗

Virtual electrodes for high-density electrode arrays

The present embodiments are directed to implantable electrode arrays having virtual electrodes. The virtual electrodes may improve the resolution of the implantable electrode array without the burden of corresponding complexity of electronic circuitry and wiring. In a particular embodiment, a virtual electrode may include one or more passive elements to help steer current to a specific location between the active electrodes. For example, a passive element may be a metalized layer on a substrate that is adjacent to, but not directly connected to an active electrode. In certain embodiments, an active electrode may be directly coupled to a power source via a conductive connection. Beneficially, the passive elements may help to increase the overall resolution of the implantable array by providing additional stimulation points without requiring additional wiring or driver circuitry for the passive elements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual electrodes for high-density electrode arrays

The present embodiments are directed to implantable electrode arrays having virtual electrodes. The virtual electrodes may improve the resolution of the implantable electrode array without the burden of corresponding complexity of electronic circuitry and wiring. In a particular embodiment, a virtual electrode may include one or more passive elements to help steer current to a specific location between the active electrodes. For example, a passive element may be a metalized layer on a substrate that is adjacent to, but not directly connected to an active electrode. In certain embodiments, an active electrode may be directly coupled to a power source via a conductive connection. Beneficially, the passive elements may help to increase the overall resolution of the implantable array by providing additional stimulation points without requiring additional wiring or driver circuitry for the passive elements.

42 ENGINEERING↗

Localized strain profile in surface electrode array for programmable composite multiferroic devices

In this work, we investigate localized in-plane strains on the microscale, induced by arrays of biased surface electrodes patterned on piezoelectrics. Particular focus is given to the influence that adjacent electrode pairs have on one another to study the impact of densely packed electrode arrays. We present a series of X-ray microdiffraction studies to reveal the spatially resolved micrometer-scale strain distribution. The strain maps with micrometer-scale resolution highlight how the local strain profile in square regions up to 250 x 250 lm 2 in size is affected by the surface electrodes that are patterned on ferroelectric single-crystal [Pb(Mg 1/3 Nb 2/3 )O 3 ] x -[PbTiO 3 ] 1-x . The experimental measurements and simulation results show the influence of electrode pair distance, positioning of the electrode pair, including the angle of placement, and neighboring electrode pair arrangements on the strength and direction of the regional strain. Our findings are relevant to the development of microarchitected strain-mediated multiferroic devices. The electrode arrays could provide array-addressable localized strain control for applications including straintronic memory, probabilistic computing platforms, microwave devices, and magnetic-activated cell sorting platforms.

42 ENGINEERING↗

Planar electrode arrays and fabrication methods thereof

The present invention relates to a method of fabricating an electrode array, in which an underlying handle wafer is removed to provide a planar device having the electrode array. Also provided are wafers including a plurality of planar devices having an electrode array, as well as sensors including such an electrode array.

Schindelholz, Eric John↗

Preparation of CuInS{sub 2}/TiO{sub 2} nanotube heterojunction arrays electrode and investigation of its photoelectrochemical properties

Graphical abstract: Schematic illustration of the synthesis steps of CuInS{sub 2}/TiO{sub 2} heterojunction arrays electrode. - Highlights: • CuInS{sub 2}/TiO{sub 2} nanotube heterojunction arrays electrode was successfully fabricated via a modified SILAR method. • Morphology, chemical compositions and the photoelectrochemical properties were studied. • The formed heterojunction structure is demonstrated as n–n type heterojunction. - Abstract: CuInS{sub 2}/TiO{sub 2} nanotube heterojunction arrays electrode was synthesized via a modified successive ionic layer adsorption and reaction (SILAR) method. The morphology, crystalline structure and chemical composition of the composite electrode were characterized with field-emission scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectra (XPS), respectively. The optical properties were investigated by UV–vis diffusion reflection spectra (DRS) and photoluminescence (PL) spectra as well as the photoelectrochemical measurements. Significantly enhanced photoelectrochemical properties of CuInS{sub 2}/TiO{sub 2} NTs electrode were observed under visible light irradiation, which could be attributed to the high absorption coefficient of CuInS{sub 2} in visible region and the heterostructure formed between CuInS{sub 2} and TiO{sub 2}.

36 MATERIALS SCIENCE↗

Synthesis of visible-light absorbing CoFe{sub 2}O{sub 4} sensitized TiO{sub 2} nanotube arrays electrode with enhanced photoelectrochemical performance

Graphical abstract: - Highlights: • TiO{sub 2} nanotube sensitized with CoFe{sub 2}O{sub 4} nanocrystals was synthesized by a facile hydrothermal method. • CoFe{sub 2}O{sub 4} nanocrystals were loaded to the outer and inner surface of TiO{sub 2} nanotube. • The CoFe{sub 2}O{sub 4} sensitized TiO{sub 2} nanotube electrode has a strong photoresponse to the light. - Abstract: TiO{sub 2} nanotube arrays sensitized with CoFe{sub 2}O{sub 4} nanocrystals were successfully synthesized via a facile hydrothermal method. The as-prepared sample was studied by X-ray diffraction (XRD), field emission scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray spectroscopy (EDX) to characterize its phase structure, morphology and chemical composition. Enhanced absorption in both UV and visible-light regions was observed for the CoFe{sub 2}O{sub 4} sensitized TiO{sub 2} nanotube arrays. The photocurrent density of CoFe{sub 2}O{sub 4} sensitized TiO{sub 2} nanotube arrays electrode was 30 times as great as that of bare TiO{sub 2} nanotube arrays electrode.

36 MATERIALS SCIENCE↗

Method for the electro-addressable functionalization of electrode arrays

A method for preparing an electrochemical biosensor uses bias-assisted assembly of unreactive -onium molecules on an electrode array followed by post-assembly electro-addressable conversion of the unreactive group to a chemical or biological recognition group. Electro-addressable functionalization of electrode arrays enables the multi-target electrochemical sensing of biological and chemical analytes.

42 ENGINEERING↗

Conformally encapsulated multi-electrode arrays with seamless insulation

Thin-film multi-electrode arrays (MEA) having one or more electrically conductive beams conformally encapsulated in a seamless block of electrically insulating material, and methods of fabricating such MEAs using reproducible, microfabrication processes. One or more electrically conductive traces are formed on scaffold material that is subsequently removed to suspend the traces over a substrate by support portions of the trace beam in contact with the substrate. By encapsulating the suspended traces, either individually or together, with a single continuous layer of an electrically insulating material, a seamless block of electrically insulating material is formed that conforms to the shape of the trace beam structure, including any trace backings which provide suspension support. Electrical contacts, electrodes, or leads of the traces are exposed from the encapsulated trace beam structure by removing the substrate.

36 MATERIALS SCIENCE↗

Numerical simulation of streamer evolution in surface dielectric barrier discharge with electrode-array

Atmospheric pressure surface dielectric barrier discharges (SDBDs) may be composed of streamers fast propagating along a dielectric surface in ambient air, producing reactive oxygen and nitrogen species, and inducing a force on the neutral gas, which can find applications, respectively, in plasma medicine and aerodynamics. In this work, a two-dimensional self-consistent fluid model was developed to study SDBDs with an electrode-array. Emphasis was placed on the interaction of counter-propagating streamers and discharge uniformity for different applied voltages and geometric configurations of the electrode-array. When two counter-propagating streamers collide, the streamers come to a stop within a certain (ultimate) distance between the streamer heads. Optimizing the applied voltages is a convenient way to improve uniformity, making the streamer heads reach a minimum distance between each other. Shortening the electrode spacing can simultaneously shorten the streamer length and the ultimate distance between streamers. Under certain discharge parameters (such as applied voltage), there exists an optimum electrode spacing maximizing uniformity.

42 ENGINEERING↗

Multifunctional nanopore electrode array method for characterizing and manipulating single entities in attoliter-volume enclosures

Structurally regular nanopore arrays fabricated to contain independently controllable annular electrodes represent a new kind of architecture capable of electrochemically addressing small collections of matter—down to the single entity (molecule, particle, and biological cell) level. Furthermore, these nanopore electrode arrays (NEAs) can also be interrogated optically to achieve single entity spectroelectrochemistry. Larger entities such as nanoparticles and single bacterial cells are investigated by dark-field scattering and potential-controlled single-cell luminescence experiments, respectively, while NEA-confined molecules are probed by single molecule luminescence. By carrying out these experiments in arrays of identically constructed nanopores, massively parallel collections of single entities can be investigated simultaneously. The multilayer metal–insulator design of the NEAs enables highly efficient redox cycling experiments with large increases in analytical sensitivity for chemical sensing applications. NEAs may also be augmented with an additional orthogonally designed nanopore layer, such as a structured block copolymer, to achieve hierarchically organized multilayer structures with multiple stimulus-responsive transport control mechanisms. Finally, NEAs constructed with a transparent bottom layer permit optical access to the interior of the nanopore, which can result in the cutoff of far-field mode propagation, effectively trapping radiation in an ultrasmall volume inside the nanopore. Furthermore, the bottom metal layer may be used as both a working electrode and an optical cladding layer, thus, producing bifunctional electrochemical zero-mode waveguide architectures capable of carrying out spectroelectrochemical investigations down to the single molecule level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Asymmetric Nafion-Coated Nanopore Electrode Arrays as Redox-Cycling-Based Electrochemical Diodes

Inspired by the functioning of cellular ion channels, pore-based structures with nanoscale openings, have been fabricated and integrated into ionic circuits, e.g. ionic diodes and transistors, for signal processing and detection. In these systems, the nonlinear current responses arise either because asymmetric nanopore geometries break the symmetry of the ion distribution, creating unequal surface charge across the nanopore, or by coupling unidirectional electron transfer within a nanopore electrode. Here, we develop a high-performance redox cycling-based electrochemical diode by coating an asymmetric ion-exchange membrane, i.e. Nafion, on the top surface of a nanopore electrode array (Nafion@NEA), in which each pore in the array exhibits one or more annular electrodes. Nafion@NEAs exhibit highly sensitive and charge-selective electroanalytical measurements due to efficient redox cycling reaction, the permselectivity of Nafion, and strong confinement of redox species in the nanopore array. In addition, the top electrode of dual electrode Nafion@NEAs can serve as a voltage-controlled switch to gate ion transport within the nanopore. Thus, Nafion@NEAs can be operated as a diode by switching voltages applied to the top and bottom electrodes of the NEA, leading to a large rectification ratio, fast response times, and simplified circuitry without the need for external electrodes. Here by taking advantage of closely spaced and individually addressable electrodes, the redox cycling electrochemical diode has the potential for application to large-scale production and electrochemically-controlled circuit operations which go well beyond conventional electronic diodes or transistors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗