Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electron beam recorder image correction for ERTS

Video data from the Earth Resources Technology Satellite (ERTS) are entered into the initial image generation system and placed on film using an electron beam to correct for both radiometric and geometric errors, a hardware unit called EBRIC was designed, fabricated, and incorporated in the image processing system. It operates under the control of a process control computer, as it varies video signal and the x and y deflection signals of the EBR.

Heffner, P.↗

Characterization of latent image of electron beam resist via critical-dimension resonant soft X-ray scattering

Metrology plays a crucial role in semiconductor manufacturing by providing accurate and precise measurement and characterization of critical parameters. With the development of high-resolution extreme ultraviolet lithography (EUVL) processes, critical dimensions are shrinking to sub-10 nm. Resist materials encounter the challenge of providing heightened sensitivity and a handle on exacerbating stochastic variations. A comprehensive understanding of the chemical profile of the latent image is pivotal for mitigating stochastic effects and optimizing pattern quality. However, the subtle differences in chemistry between the exposed and unexposed regions of the resists make it extremely challenging to characterize the latent images with sub-nanometer precision. Here, we develop the metrology with critical-dimension resonant soft X-ray scattering (CD-RSoXS) to probe the chemical profiles of latent images stored in resist after exposure. The combination of absorption spectroscopy and enhanced scattering contrast makes it possible to characterize the subtle structural and chemical variations in the latent image. Moreover, the results of the measurements are compared with the simulations with a finite element method–based Maxwell solver to extract a detailed profile of the latent and developed images. We demonstrate that the CD-RSoXS technique can provide valuable insights into the high spatial resolution and local chemical sensitivity simultaneously, which is crucial to understanding the resolution limits and stochastic effects in EUVL processes.

36 MATERIALS SCIENCE↗

Concentric semi-circular split profiling for computed tomographic imaging of electronic beams

Apparatus and method for analyzing an electron beam including a circular sensor disk adapted to receive the electron beam, an inner semi-circular slit in the circular sensor disk; an outer semi-circular slit in the circular sensor disk wherein the outer semi-circular slit is spaced from the first semi-circular slit by a fixed distance; a system for sweeping the electron beam radially outward from the central axis to the inner semi-circular slit and outer second semi-circular slit; a sensor structure operatively connected to the circular sensor disk wherein the sensor structure receives the electron beam when it passes over the inner semi-circular slit and the outer semi-circular slit; and a device for measuring the electron beam that is intercepted by the inner semi-circular slit and the outer semi-circular slit.

42 ENGINEERING↗

Angled slit design for computed tomographic imaging of electron beams

Computed tomographic method and apparatus includes an electron or ion beam having a beam axis, a refractory metal disk; at least one slit in the refractory metal disk that receive the beam, wherein the slit is at an angle to the beam axis; a beam entrance opening in the slit that allows the beam to enter; an effective beam exit opening in the slit that allow the beam to exit, wherein the beam effective exit opening is smaller than the beam entrance opening; and a system for moving the beam across the refractory metal disk, wherein the beam enters the slit through the beam entrance opening and exits the slit through the effective beam exit opening; and a computed tomographic device for measuring the beam that enters and exits the slit for analyzing the beam.

Elmer, John W.↗

Reconstruction and uncertainty quantification of lattice Hamiltonian model parameters from observations of microscopic degrees of freedom

The emergence of scanning probe and electron beam imaging techniques has allowed quantitative studies of atomic structure and minute details of electronic and vibrational structure on the level of individual atomic units. These microscopic descriptors, in turn, can be associated with local symmetry breaking phenomena, representing the stochastic manifestation of the underpinning generative physical model. In this work, we explore the reconstruction of exchange integrals in the Hamiltonian for a lattice model with two competing interactions from observations of microscopic degrees of freedom and establish the uncertainties and reliability of such analysis in a broad parameter-temperature space. In contrast to other approaches, we specifically specify a loss function inherent to thermodynamic systems and utilize it to estimate uncertainty in simulated realizations of different models. As an ancillary task, we develop a machine learning approach based on histogram clustering to predict phase diagrams efficiently using a reduced descriptor space. We further demonstrate that reconstruction is possible well above the phase transition and in the regions of parameter space when the macroscopic ground state of the system is poorly defined due to frustrated interactions. This suggests that this approach can be applied to the traditionally complex problems of condensed matter physics such as ferroelectric relaxors and morphotropic phase boundary systems, spin and cluster glasses, and quantum systems once the local descriptors linked to the relevant physical behaviors are known.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic-Scale Imaging of Lithium Vacancies in a Battery Cathode by Multislice Electron Ptychography

Atomic-resolution imaging of battery materials is critical for identification of local defects and structural variations, which are tied to battery performance. However, since battery materials are, by design, optimized to allow ion motion in response to an applied electric field, they are also very sensitive to radiation damage by an electron beam. Image resolution is therefore severely constrained by the dose applied. Here, we show that multislice electron ptychography (MEP) can provide sub-ångström lateral resolution images of both light and heavy elements of a Li-ion battery cathode, along with nanometer-scale depth information and greater dose efficiency than conventional electron microscopy methods. Using the depth-sectioning capability of MEP, we have been able to obtain direct visualizations of Li vacancy clusters, atom column by atom column, in Li x Ni 0.33 Mn 0.33 Co 0.33 O 2 (NMC111) cathodes. This capability to track Li distributions will be valuable in understanding, informing, and optimizing electrode material design for ion storage and transfer.

batteries↗

Advanced scanners and imaging systems for earth observations

Assessments of present and future sensors and sensor related technology are reported along with a description of user needs and applications. Five areas are outlined: (1) electromechanical scanners, (2) self-scanned solid state sensors, (3) electron beam imagers, (4) sensor related technology, and (5) user applications. Recommendations, charts, system designs, technical approaches, and bibliographies are included for each area.

Source record↗

Patch-Based Convolutional Neural Networks for Multiple Microstructural Features Detection in FIB-SEM Micrographs of Irradiated Nuclear Fuel

Focused ion beam scanning electron microscopy (FIB-SEM) tomography has increasingly been utilized for acquiring three-dimensional (3D) microstructure features at the sub-micron scale in irradiated nuclear materials. This technique involves sequential ion beam slicing followed by electron beam imaging and compositional mapping using energy dispersive spectroscopy (EDS). Despite its growing use, several challenges persist. These include the time-intensive nature of data collection of EDS data, difficulties in distinguishing between various microstructures, and issues with image alignment. These challenges currently limit the broader application of FIB-SEM tomography in the field. To overcome these limitations, we propose using convolutional neural networks (CNNs) to automate microstructure identification in SEM images. Our study introduces a new framework for identifying microstructures in irradiated U-10Zr (wt. %) metallic fuel with limited annotated data. The framework includes the creation of a reliable annotated dataset with paired SEM and ground truth data from EDS maps, the applications of CNNs for microstructure identification, and the validation of model performance. Specifically, we employed the Segment Anything Model (SAM) to align SEM images with corresponding EDS maps and focused ion beam (FIB) tomography SEM data. We evaluate several models, including Patch-based U-Net, Attention U-Net, and Residual U-Net, finding that patch-based U-Net exhibits superior segmentation performance and consistency. This approach reduces reliance on EDS detectors and aids in accelerating nuclear material analysis process, highlighting the potential of advanced deep learning techniques to improve microstructural understanding in nuclear material. This is the first framework to integrate SAM and Patch-based CNN models for semantic segmentation of irradiated nuclear materials, with potential applicability to other tomography datasets.

36 - MATERIALS SCIENCE↗

Using SPHINX Accelerator to Measure Heat Transfer in Metal Foils [Slides]

Experiments on the SPHINX accelerator at Sandia National Laboratories (SNL) looked at electron beam heating of metal foils used in Bremsstrahlung flash x-ray production. Titanium and tantalum foils were exposed to electron beam energies of up to 2MeV to determine surface heating. As part of the experiment, the x-ray dose profiles were characterized using a scintillating panel (EJ-230) placed both perpendicular and parallel to the photon beam. This was followed by direct electron beam imaging using a fast-gated ICCD camera and a fused silica Cherenkov witness plate. Once characterized, the foil was directly measured using a mid-wave (3-5 micron) infrared camera (MWIR) to determine the peak surface temperatures and spatially-resolved thermal profiles. Additionally, an IR pyrometer was used in a single wavelength mode (2.3 µm) to determine localized surface temperatures as well. Results are compared with calculations of surface temperatures obtained from e-beam energy depositions combined with the specific heats of the foils. This is the first attempt to directly measure the surface temperature profile on a short-pulse (10 nanoseconds) flash x-ray source using MWIR imaging. These data are directly relevant for Monte Carlo/Integrated Tiger Series electron/photon transport code results being used in the design of future Bremsstrahlung sources such as CREST.

43 PARTICLE ACCELERATORS↗

Low-distortion resistive anodes for two-dimensional position-sensitive MCP systems

Microchannel plates (MCPs) are frequently used with resistive anodes to detect charged particles or photons and yield analog signals from which event positions can be decoded. The paper discusses a four-corner concave circular arc terminated resistive anode that permits theoretically distortionless encoding of Cartesian event positions into pulse charge ratios. The theory of the circular arc terminated anode is discussed along with anode design and performance. Electron beam images obtained by using such an anode are presented to confirm the usefulness of the approach.

Lampton, M.↗

Enabling the Acquisition of Electron Beam-Induced Current (EBIC) Images in Conventional SEM and STEM Instruments

Electron beam-induced current (EBIC) imaging is a well-established scanning electron microscope (SEM) technique used to analyze the behavior of microelectronic devices including solar cells. Recently, the application of EBIC imaging in an aberration-corrected scanning transmission electron microscope (STEM) has been demonstrated and offers great potential for the in situ study of electronic materials, correlating charge transport properties to atomic structural and elemental information. Here, this work presents two ways to implement EBIC imaging in conventional SEM and STEM systems: one relying on the instrument's inherent scanning and imaging electronics and the other involving third-party systems usually available in electron microscopes. The implementation of lock-in EBIC in systems equipped with a fast beam blanker is also described. In addition, this work shows and discusses the different mechanisms at play in EBIC imaging and their dependence on beam energy, sample impedance, and electrical measurement configuration, providing researchers with the basic information needed to apply the technique to their research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Image tube

An optical image is projected onto a planar surface of a photocathode that derives an electron beam replica of the image. A target electrode displaced relative to the photocathode so that it does not obstruct the optical image includes a planar surface for receiving and deriving an accurate replica of the electron beam image. The two planar surfaces are parallel. The electron beam image is focused on the target electrode by providing throughout a region that extends between the planar surfaces of the photocathode and receiving electrode, constant homogeneous dc electric and magnetic fields. The electric field extends in a direction perpendicular to the planar surfaces while the magnetic field extends along a straight line that intersects the photocathode and target electrode at an acute angle.

Hallam, K. L.↗

3D magnetic imaging using electron vortex beam microscopy

Abstract Electron vortex beams are free-electron waves that carry orbital angular momentum. There has been growing theoretical and experimental interest in the use of electron vortex beams as a tool for the investigation of magnetic materials. However, due to the complex wavefront of the propagating waves, a deeper understanding of the interaction of electron vortex beams and the magnetic sample is needed. Here we calculate the magnetic phase shift that an electron vortex beam obtains upon transmitting through a magnetic sample. We show that this magnetic phase shift is influenced by the out-of-plane magnetization, which is a unique characteristic of incident electron vortex beams and is proportional to their orbital angular momentum. Finally, we develop a phase retrieval methodology to retrieve the out-of-plane component of magnetization. Based on our theory, we discuss suitable experimental conditions that would enable this imaging capability for magnetic materials and further extend to non-magnetic chiral materials.

47 OTHER INSTRUMENTATION↗

In-Process Thermal Imaging of the Electron Beam Freeform Fabrication Process

Researchers at NASA Langley Research Center have been developing the Electron Beam Freeform Fabrication (EBF3) metal additive manufacturing process for the past 15 years. In this process, an electron beam is used as a heat source to create a small molten pool on a substrate into which wire is fed. The electron beam and wire feed assembly are translated with respect to the substrate to follow a predetermined tool path. This process is repeated in a layer-wise fashion to fabricate metal structural components. In-process imaging has been integrated into the EBF3 system using a near-infrared (NIR) camera. The images are processed to provide thermal and spatial measurements that have been incorporated into a closed-loop control system to maintain consistent thermal conditions throughout the build. Other information in the thermal images is being used to assess quality in real time by detecting flaws in prior layers of the deposit. NIR camera incorporation into the system has improved the consistency of the deposited material and provides the potential for real-time flaw detection which, ultimately, could lead to the manufacture of better, more reliable components using this additive manufacturing process.

Taminger, Karen M.↗

Stabilized Synthesis of 2D Verbeekite: Monoclinic PdSe 2 Crystals with High Mobility and In-Plane Optical and Electrical Anisotropy

PdSe 2 has a layered structure with an unusual, puckered Cairo pentagonal tiling. Its atomic bond configuration features planar 4-fold-coordinated Pd atoms and intralayer Se–Se bonds that enable polymorphic phases with distinct electronic and quantum properties, especially when atomically thin. PdSe 2 is conventionally orthorhombic, and direct synthesis of its metastable polymorphic phases is still a challenge. Here, we report an ambient-pressure chemical vapor deposition approach to synthesize metastable monoclinic PdSe 2 . Monoclinic PdSe 2 is shown to be synthesized selectively under Se-deficient conditions that induce Se vacancies. These defects are shown by first-principles density functional theory calculations to reduce the free energy of the metastable monoclinic phase, thereby stabilizing it during synthesis. Further, the structure and composition of the monoclinic PdSe 2 crystals are identified and characterized by scanning transmission electron microscopy imaging, convergent beam electron diffraction, and electron energy loss spectroscopy. Polarized Raman spectroscopy of the monoclinic PdSe 2 flakes reveals their strong in-plane optical anisotropy. Electrical transport measurements show that the monoclinic PdSe 2 exhibits n-type charge carrier conduction with electron mobilities up to ~298 cm 2 V –1 s –1 and a strong in-plane electron mobility anisotropy of ~1.9. The defect-mediated growth pathway identified in this work is promising for phase-selective direct synthesis of other 2D transition metal dichalcogenides.

2D material↗

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗