Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron yield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental Measurements of the Secondary Electron Yield in the Experimental Measurement of the Secondary Electron Yield in the PEP-II Particle Accelerator Beam Line

Beam instability caused by the electron cloud has been observed in positron and proton storage rings and it is expected to be a limiting factor in the performance of the positron Damping Ring (DR) of future Linear Colliders (LC) such as ILC and CLIC. To test a series of promising possible electron cloud mitigation techniques as surface coatings and grooves, in the Positron Low Energy Ring (LER) of the PEP-II accelerator, we have installed several test vacuum chambers including (i) a special chamber to monitor the variation of the secondary electron yield of technical surface materials and coatings under the effect of ion, electron and photon conditioning in situ in the beam line; (ii) chambers with grooves in a straight magnetic-free section; and (iii) coated chambers in a dedicated newly installed 4-magnet chicane to study mitigations in a magnetic field region. In this paper, we describe the ongoing R&D effort to mitigate the electron cloud effect for the LC damping ring, focusing on the first experimental area and on results of the reduction of the secondary electron yield due to in situ conditioning.

43 PARTICLE ACCELERATORS↗

Low secondary electron yield engineered surface for electron cloud mitigation

Secondary electron yield (SEY or δ) limits the performance of a number of devices. Particularly, in high-energy charged particle accelerators, the beam-induced electron multipacting is one of the main sources of electron cloud (e-cloud) build up on the beam path; in radio frequency wave guides, the electron multipacting limits their lifetime and causes power loss; and in detectors, the secondary electrons define the signal background and reduce the sensitivity. The best solution would be a material with a low SEY coating and for many applications δ < 1 would be sufficient. We report on an alternative surface preparation to the ones that are currently advocated. Three commonly used materials in accelerator vacuum chambers (stainless steel, copper, and aluminium) were laser processed to create a highly regular surface topography. It is shown that this treatment reduces the SEY of the copper, aluminium, and stainless steel from δ{sub max} of 1.90, 2.55, and 2.25 to 1.12, 1.45, and 1.12, respectively. The δ{sub max} further reduced to 0.76–0.78 for all three treated metals after bombardment with 500 eV electrons to a dose between 3.5 × 10{sup −3} and 2.0 × 10{sup −2} C·mm{sup −2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Differential electron yield imaging with STXM

In this report total electron yield (TEY) imaging is an established scanning transmission X-ray microscopy (STXM) technique that gives varying contrast based on a sample's geometry, elemental composition, and electrical conductivity. However, the TEY-STXM signal is determined solely by the electrons that the beam ejects from the sample. A related technique, X-ray beam-induced current (XBIC) imaging, is sensitive to electrons and holes independently, but requires electric fields in the sample. Here we report that multi-electrode devices can be wired to produce differential electron yield (DEY) contrast, which is also independently sensitive to electrons and holes, but does not require an electric field. Depending on whether the region illuminated by the focused STXM beam is better connected to one electrode or another, the DEY-TXM contrast changes sign. DEY-STXM images thus provide a vivid map of a device's connectivity landscape, which can be key to understanding device function and failure. To demonstrate an application in the area of failure analysis, we image a 100 nm, lithographically-defined aluminum nanowire that has failed after being stressed with a large current density.

47 OTHER INSTRUMENTATION↗

Note: A simple charge neutralization method for measuring the secondary electron yield of insulators

We report on a simple and effective charge neutralization method for measuring the total electron-induced secondary electron yield of insulators in a measurement system with a single pulsed electron gun. In this method, the secondary electron collector is negatively biased with respect to the sample to force some emitted secondary electrons to return to the sample surface and therefore to neutralize positive charges accumulated in the sample during the previous measurement. The adequate negative bias is determined and the equilibrium state of negative charging is discussed. The efficacy of the method is demonstrated by the measured electron yields in the cases with and without charge neutralization and by comparison with existing electron yield data of polyimide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digging deeper: Buried layers and interfaces studied by modified total electron yield and soft x-ray absorption spectroscopy

We report on the soft x-ray absorption spectroscopy investigation of thin film capacitors using a modified total electron yield detection mode. This mode utilizes two ammeters instead of one as commonly employed in the classical total electron yield scheme to measure photocurrents of devices under soft x-ray irradiation. The advantage of this configuration over the surface sensitive classical total electron yield mode is that it can provide information from buried layers and interfaces up to a thickness equal to the penetration depth of soft x-rays. The method can be easily adapted to existing synchrotron end stations. We investigate dielectric capacitors with dissimilar electrodes to assess the feasibility of the modified total electron yield method. Furthermore, in operando soft x-ray absorption spectroscopy measurements are performed on ferroelectric capacitors under bias and using two ammeters. The experimental results are discussed in terms of the external and internal photoemission processes and their distribution in thin film capacitors under an external bias condition. The proposed detection method opens the way to perform electronic and chemical state analyses of the buried interfaces and layers in various devices like multiferroic tunnel junctions, memristive devices, etc., during operation under an applied bias.

Kröger, E.↗

The influence of secondary electron yield uncertainty on the single-sided multipacting in dielectrics

Multipacting is an electrical discharge caused by the emission of secondary electrons which can occur in vacuum radio frequency systems. Generally multipacting is highly undesirable obstacle, which increases the noise level as well as the return loss of radio frequency systems. Therefore, a prediction of multipacting is necessary to avoid it during radio frequency system design. In this regard, the accurate evaluation of the factors that affect multipacting is required. One of the critical factors determining the multipacting development is the secondary electron yield of the material. In practice the emission properties of materials are not known very accurately. There are uncertainties in the measured values of this yield. In this paper, the generalized Polynomial Chaos (gPC) method is used to quantify uncertainty of the secondary electron yield. This method is verified by Monte Carlo simulation. The effect of uncertainty for two secondary electron yield parameters is then investigated on the multipacting using gPC method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of multipacting threshold sensitivity to the random distributions of the secondary electron yield parameters

The way multipacting develops, depends strongly on the secondary emission property of the surface material. The knowledge of secondary electron yield is crucial for accurate prediction of the multipacting threshold. Variations in secondary electron yield parameters from experimental measurements create uncertainty, stemming from handling and surface preparation, and these uncertainties significantly affect multipacting threshold predictions. Despite their significance, the previous studies on the multipacting phenomenon did not adequately address the effect of an assumed random distribution of the secondary emission parameters on the multipacting threshold. Therefore, this paper aims to provide a comprehensive statistical study on how the different random distributions of the secondary emission parameters and, as a result, the uncertainty in the secondary electron yield affect multipacting thresholds. We focus on three commonly used distributions, namely uniform, normal, and truncated normal distributions, to define the uncertainty of random inputs. We use the chaos polynomial expansion method to determine how much each of the random parameters contributes to the multipacting threshold uncertainty. Additionally, we calculate Sobol sensitivity indices to evaluate the impact of the individual parameters or groups of parameters on the model outputs and study how different random distributions of these parameters affected the Sobol index results.

physics↗

Single electron yields from semileptonic charm and bottom hadron decays in Au + Au collisions at s N N = 200 GeV

We measured open heavy flavor production in minimum bias Au + Au collisions at √s( NN ) = 200 GeV via the yields of electrons from semileptonic decays of charm and bottom hadrons, using the PHENIX Collaboration at the Relativistic Heavy Ion Collider. In the past, heavy flavor electron measurements indicated substantial modification in the momentum distribution of the parent heavy quarks owing to the quark-gluon plasma created in these collisions. For the first time, using the PHENIX silicon vertex detector to measure precision displaced tracking, the relative contributions from charm and bottom hadrons to these electrons as a function of transverse momentum are measured in Au + Au collisions. Here, we compare the fraction of electrons from bottom hadrons to previously published results extracted from electron-hadron correlations in p + p collisions at √s( NN ) = 200 GeV and find the fractions to be similar within the large uncertainties on both measurements for p (T) > 4 GeV/c. We use the bottom electron fractions in Au + Au and p + p along with the previously measured heavy flavor electron R (AA) to calculate the R (AA) for electrons from charm and bottom hadron decays separately. Finally, we find that electrons from bottom hadron decays are less suppressed than those from charm for the region 3 < p (T) < 4 GeV/c.

43 PARTICLE ACCELERATORS↗

A versatile detector for total fluorescence and electron yield experiments

The combination of a non-coated silicon photodiode with electron repelling meshes makes a versatile detector for total fluorescence yield and electron yield techniques highly suitable for x-ray absorption spectroscopy. In particular, a copper mesh with a bias voltage allows to suppress or transmit the electron yield signal. The performance of this detection scheme has been characterized by near edge x-ray absorption fine structure studies of thermal oxidized silicon and sapphire. The results show that the new detector probes both electron yield and for a bias voltage exceeding the maximum photon energy the total fluorescence yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Secondary Electron Yield Measurements and Groove Chambers Tests in the PEP-II Beam Line Straights Sections

Beam instability caused by the electron cloud has been observed in positron and proton storage rings and it is expected to be a limiting factor in the performance of the positron Damping Ring (DR) of future Linear Colliders such as ILC and CLIC [1, 2]. In the Positron Low Energy Ring (LER) of the PEP-II accelerator, we have installed vacuum chambers with rectangular grooves in a straight magnetic-free section to test this promising possible electron cloud mitigation technique. We have also installed a special chamber to monitor the secondary electron yield of TiN and TiZrV (NEG) coating, Copper, Stainless Steel and Aluminum under the effect of electron and photon conditioning in situ in the beam line. In this paper, we describe the ongoing R&D effort to mitigate the electron cloud effect for the ILC damping ring, the latest results on in situ secondary electron yield conditioning and recent update on the groove tests in PEP-II.

36 MATERIALS SCIENCE↗

Suppression of secondary electron yield by micro-porous array structure

We study secondary electron yield (SEY) suppression for metal materials using a roughened surface with a micro-porous array. First, we perform a Monte Carlo simulation of the electron trajectory in a single cylindrical well using a phenomenological model of secondary electron emission and the SEY suppression efficiency of a micro-porous array. The simulation results show that the SEY of a roughened surface is affected significantly by the aspect ratio of the micro-pores and the surface porosity of the metal plate. Then, to verify the simulation results, we produce a micro-porous array on metal plates using photolithography and measure their SEYs. We show that the micro-porous array structure can efficiently suppress the SEY of metal materials, and the measurements agree quantitatively with the corresponding simulation results. Finally, we derive an analytical formula to evaluate easily the SEY suppression efficiency of the Ag micro-porous array. In total, the micro-porous array proposed in this paper offers an alternative to SEY suppression in related areas such as multipactor effects in satellite payloads or electron cloud effects in accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Secondary Electron Yield and Groove Chamber Tests in PEP-II

Possible remedies for the electron cloud in positron damping ring (DR) of the International Linear Collider (ILC) includes thin-film coatings, surface conditioning, photon antechamber, clearing electrodes and chamber with grooves or slots [1]. We installed chambers in the PEP-II Low Energy Ring (LER) to monitor the secondary electron yield (SEY) of TiN, TiZrV (NEG) and technical accelerator materials under the effect of electron and photon conditioning in situ. We have also installed chambers with rectangular grooves in straight sections to test this possible mitigation technique. In this paper, we describe the ILC R&D ongoing effort at SLAC to reduce the electron cloud effect in the damping ring, the chambers installation in the PEP-II and latest results.

43 PARTICLE ACCELERATORS↗

Determination of the maximum energy loss for electron stopping power calculations and its effect on backscattering electron yield in Monte-Carlo simulations applying continuous slowing-down approximation

The maximum energy loss for electron stopping power calculations by the full Penn algorithm within the dielectric formalism is determined with taking into account the contribution of electron and plasmon excitations. Use of these calculated electron stopping powers in Monte Carlo simulations applying continuous slowing down approximation gives the backscattering electron yields in much better agreement with experimental data than previous other theoretical results. The muffin-tin model is used to describe the electron elastic scattering by atom bound in solids with taking into account the exchange correlation and polarization effect.

36 MATERIALS SCIENCE↗

Efficient laser absorption and enhanced electron yield in the laser-target interaction by using a cone-nanolayer target

A cone-nanolayer target that combines the advantages of the conical and layered geometries for electron acceleration in laser-target interaction is proposed. Two-dimensional particle-in-cell (PIC) simulations show that the cone-nanolayer target can enhance laser absorption and electron yield. With suitable choice of the laser and target parameters, the cone-nanolayer target can be a controllable source of hot electrons at desired energy ranges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Secondary Electron Yield Measurements of Fermilab?s Main Injector Vacuum Vessel

We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.

43 PARTICLE ACCELERATORS↗

A fully contained sample holder capable of electron-yield detection at soft X-ray energies

A holder has been developed that enables electron yield-detected soft X-ray spectroscopy of fully contained samples at low temperature. Crucially, this design uses elements of the sample containment to collect ejected electrons, removing the need to expose samples directly to the vacuum environment of the spectrometer. The design is modular and should be adaptable to a number of different endstation configurations, enabling spectroscopy of air-sensitive, radioactive and vacuum-sensitive (biological) samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗