Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrostatic (ESD) testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Imaging Indicator for ESD Safety Testing

This report describes the development of a new detection method for electrostatic discharge (ESD) testing of explosives, using a single-lens reflex (SLR) digital camera and a 200-mm macro lens. This method has demonstrated several distinct advantages to other current ESD detection methods, including the creation of a permanent record, an enlarged image for real-time viewing as well as extended periods of review, and ability to combine with most other Go/No-Go sensors. This report includes details of the method, including camera settings and position, and results with well-characterized explosives PETN and RDX, and two ESD-sensitive aluminum powders.

Whinnery, LeRoy L.↗

The Effects of Electrostatic Discharge Phenomena on Detonator Response: A Framework for Evaluating Parameters Relevant to Quantification of Margins and Uncertainties

Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Pantex are collaborating on a Nuclear Safety Research & Development (NSR&D) project to develop a common Quantification of Margins and Uncertainties (QMU) framework for explosive safety analysis. An analysis of electrostatic discharge (ESD) data serves as an initial test case for methodology development. This analysis examines measurements of electrical characteristics of production environments, tests designed to measure ESD response of detonators, and information on interactions between variables drawn from expert knowledge and physics models.

42 ENGINEERING↗

Production of desensitized, ultrafine PETN powder

Pentaerythritol tetranitrate (PETN) is a widely studied high explosive (HE), most commonly used in detonator applications. In this work, we use a spray drying technique to manufacture a new “nano-powder” morphology of PETN. The spray dried PETN is several orders of magnitude smaller in particle size than traditionally prepared PETN powders. The spray dried PETN has a mostly spherical and smooth morphology, while traditional crystalline PETN typically has sharp edges and crystal facets. Small-scale sensitivity tests including drop-weight impact, friction, and electrostatic discharge (ESD) indicate the spray dried PETN is less sensitive than traditionally used forms of PETN powders. Furthermore, we also observed no changes in chemical properties (melt temperature and onset of decomposition) after spray drying, and the material remains in the tetragonal, crystalline phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical Basis for Electromagnetic Compatibility Regulatory Guidance Update

The objective of this report is to serve as the technical basis document for the next, planned revision of this RG that highlights and provides the rationale for the recommended changes. The structure of this document follows and summarizes the several assessment activities undertaken during the course of this project to evaluate new and updated electromagnetic compatibility (EMC) standards, testing methods and limits, and relevant technology developments being incorporated into plant activities that may have EMI/RFI implications, as well as other specific issues, including impacts of electrostatic discharge (ESD) on safety equipment and impacts on increased usage of wireless devices in nuclear power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

10-Gb/s Distributed Amplifier-Based VCSEL Driver IC With ESD Protection in 130-nm CMOS

Here, this paper presents a low-power 10-Gb/s vertical cavity surface emitting laser (VCSEL) driver integrated circuit (IC) with electrostatic discharge (ESD) protection in the 130-nm CMOS technology. A distributed amplifier (DA)-based modulator is proposed to boost the driver bandwidth. It employs artificial transmission lines to cancel the device parasitic capacitances of the driver. A distributed ESD protection technique is applied to equalize the group delay of the DA to optimize the jitter performance. To minimize the silicon area, the optimal number of DA taps in the proposed modulator has been derived. To compensate for the capacitive load and the channel losses at the output of the driver, a frequency-domain preemphasis scheme is proposed. The proposed DA modulator occupies an area of 0.69 mm 2 , and the entire driver IC has a die size of 2 mm×2 mm, including the pads. Both electrical and optical tests have been carried out to characterize the performance of the proposed VCSEL driver IC. Measurements at a data rate of 10-Gb/s demonstrate a typical power consumption of 85 mW under a single 2.5 V supply voltage (49 mW, if separate 1.2 and 2.5 V supplies are used) and an rms jitter of 0.63 and 1.12 ps for the electrical test and optical test, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detonator Bridgewire Gap Tests Using SE-1/31 Detonator Housings with High Surface Area PETN

The purpose of this work is to develop a basis for addressing broken and damaged bridgewires in exploding bridgewire (EBW) detonators and their vulnerability to electrostatic discharge (ESD) sources. Parameters such as gap width, breakdown voltage, charge voltage, and source energy are explored. We are interested in understanding how bridgewire gap length affects the detonator initiability and safety.

42 ENGINEERING↗

PSL-AC-CP-1102-004-03: Electrostatic Discharge Simulator Kit Model 930D and Associated Current-Viewing Resistor (V.04)

This document provides instructions for calibrating the Electro-Tech (ETS) electrostatic discharge (ESD) simulator, Model 930D. The calibration shall meet the ± 5% specification for resistance and capacitance as specified in MIL-STD-331C 2009 newer. A series of direct measurements of the Device Under Test (DUT) output at 25 kV using a calibrated LeCroy HDO 6104 oscilloscope (or equivalent 1 MΩ) input impedance storage oscilloscope) are recorded through the 500-pF capacitor, 500-Ω resistor, and a 1-Ω Current Viewing Resistor (CVR). The certified value of the DUT's 25 kV output is calculated using Ohms Law and the certified system resistance and capacitance described in this procedure. Read this document in its entirety before proceeding with the calibration.

42 ENGINEERING↗

Integrated Data Collection Analysis (IDCA) Program - AN and Bullseye Smokeless Powder

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of ammonium nitrate (AN) mixed with Bullseye® smokeless powder (Gunpowder). The participants found the AN/Gunpowder to: 1) have a range of sensitivity to impact, comparable to or less than RDX, 2) be fairly insensitive to friction as measured by BAM and ABL, 3) have a range for ESD, from insensitive to more sensitive than PETN, and 4) have thermal sensitivity about the same as PETN and Gunpowder. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed when developing safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods. Note, however, the test procedures differ among the laboratories. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent. Keywords: Small-scale safety testing, proficiency test, impact-, friction-, spark discharge-, thermal testing, round-robin test, safety testing protocols, HME, RDX, potassium perchlorate, potassium chlorate, sodium chlorate, sugar, dodecane, PETN, carbon, ammonium nitrate, Gunpowder, Bullseye® smokeless powder.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — Bullseye ® Smokeless Powder

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of Bullseye ® smokeless powder (Gunpowder). The participants found the Gunpowder: 1) to have a range of sensitivity to impact, from less than RDX to almost as sensitive as PETN, 2) to be moderately sensitive to BAM and ABL friction, 3) have a range for ESD, from insensitive to more sensitive than PETN, and 4) to have thermal sensitivity about the same as PETN and RDX.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - RDX Standard Data Set 2

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, from testing the second time in the Proficiency Test. This RDX testing (Set 2) compared to the first (Set 1) was found to have about the same impact sensitivity, have more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Analysis (IDCA) Program - PETN Class 4 Standard

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of PETN Class 4. The PETN was found to have: 1) an impact sensitivity (DH 50 ) range of 6 to 12 cm, 2) a BAM friction sensitivity (F 50 ) range 7 to 11 kg, TIL (0/10) of 3.7 to 7.2 kg, 3) a ABL friction sensitivity threshold of 5 or less psig at 8 fps, 4) an ABL ESD sensitivity threshold of 0.031 to 0.326 j/g, and 5) a thermal sensitivity of an endothermic feature with T min = ~ 141 °C, and a exothermic feature with a T max = ~205°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — Ammonium Nitrate

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of ammonium nitrate (AN). AN was tested, in most cases, as both received from manufacturer and dried/sieved. The participants found the AN to be: 1) insensitive in Type 12A impact testing (although with a wide range of values), 2) completely insensitive in BAM friction testing, 3) less sensitive than the RDX standard in ABL friction testing, 4) less sensitive than RDX in ABL ESD testing, and 5) less sensitive than RDX and PETN in DSC thermal analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — RDX Standard Data Sets

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, for a third and fourth time in the Proficiency Test and averaged with the analysis results from the first and second time. The results, from averaging all four sets (1, 2, 3 and 4) of data suggest a material to have slightly more impact sensitivity, more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity, compared to the results from Set 1, which was used previously as the values for the RDX standard in IDCA Analysis Reports.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - NaClO 3 /Icing Sugar

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of NaClO 3 and icing sugar—NaClO 3 /icing sugar mixture. The mixture was found to: be more sensitive than RDX but less sensitive than PETN in impact testing (180-grit sandpaper); be more sensitive than RDX and about the same sensitivity as PETN in BAM fiction testing; be less sensitive than RDX and PETN except for one participant found the mixture more sensitive than PETN in ABL ESD testing; and to have one to three exothermic features with the lowest temperature event occurring at ~ 160°C always observed in thermal testing. Variations in testing parameters also affected the sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

An Analysis of Electrostatic Discharge Considerations in the Use of Sodium Bicarbonate Media for De-Potting Sensitive Electronic Assemblies

Sodium bicarbonate blast media offers superior performance in removing low-to-medium density polyurethane foam potting materials from electronic assemblies compared to conventional abrasive or other low-hardness blast media. This work identifies a class of processing equipment suitable for potting removal in electronic assemblies and provides a technical evaluation of appropriate process controls that significantly reduce the potential for Electrostatic Discharge (ESD) degradation or damage. Once appropriate process controls are added, the class of blast equipment demonstrated here, previously used only for non-ESD sensitive assemblies, can be safely used to provide new capabilities for component-level support. In many cases, assemblies that have been de-potted using sodium bicarbonate can be disassembled and rebuilt using normal production processes, enabling repair, reacceptance, and surveillance of assemblies that was previously impractical. This paper presents the results of a study that identifies significant process variables and their contribution to ESD generation. Data are presented to quantify process-related peak ESD voltages and mitigation methods. A discussion of how to implement practical ESD controls and de-potting process test methodologies is provided. The intent of this work is to document foundational experimental work that provides a technical basis for sodium bicarbonate as an ESD-safe material for use in de-potting processes when appropriate controls are implemented.

Kinzel, Robert L.↗

Effects of electrostatic discharge on three cryogenic temperature sensor models

Cryogenic temperature sensors are not usually thought of as electrostatic discharge (ESD) sensitive devices. However, the most common cryogenic thermometers in use today are thermally sensitive diodes or resistors - both electronic devices in their base form. As such, they are sensitive to ESD at some level above which either catastrophic or latent damage can occur. Instituting an ESD program for safe handling and installation of the sensor is costly and it is desirable to balance the risk of ESD damage against this cost. However, this risk cannot be evaluated without specific knowledge of the ESD vulnerability of the devices in question. This work examines three types of cryogenic temperature sensors for ESD sensitivity - silicon diodes, Cernox(trade mark, serif) resistors, and wire wound platinum resistors, all manufactured by Lake Shore Cryotronics, Inc. Testing was performed per TIA/EIA FOTP129 (Human Body Model). Damage was found to occur in the silicon diode sensors at discharge levels of 1,500 V. For Cernox(trade mark, serif) temperature sensors, damage was observed at 3,500 V. The platinum temperature sensors were not damaged by ESD exposure levels of 9,900 V. At the lower damage limit, both the silicon diode and the Cernox(trade mark, serif) temperature sensors showed relatively small calibration shifts of 1 to 3 K at room temperature. The diode sensors were stable with time and thermal cycling, but the long term stability of the Cernox(trade mark, serif) sensors was degraded. Catastrophic failure occurred at higher levels of ESD exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗