Search NASASearch

SEARCH · Search NASA

Results for “emergency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of the Table of Initial Isolation and Protective Action Distances for the 2024 Emergency Response Guidebook

The transportation of hazardous materials creates numerous opportunities for the release of toxic substances into the environment, whether caused by traffic accidents, train derailments, equipment failures, or human error. Such releases can pose acute hazards to the general public and to emergency response personnel who are the first to arrive at the scene. To help first responders determine whether a shipment is potentially hazardous and decide what actions should be taken if a toxic spill does occur, the Emergency Response Guidebook (ERG) is published by the U.S. Department of Transportation (DOT), Transport Canada, and the Secretariat of Transport and Communications of Mexico; with contributions from Centro de Informaciòn Quìmica para Emergencias of Argentina. The most recent version is the 2024 edition of the ERG (ERG 2024), titled 2024 Emergency Response Guidebook (ERG2024). The ERG provides essential information about firefighting, spill response, and potential public health effects. For chemicals that are toxic by inhalation (TIH) and chemicals that produce TIH gases upon reaction with water (TIH by water reactivity or TIHWR), the ERG provides initial isolation distances (IIDs) and protective action distances (PADs). The IID defines the radius of the zone around the spill that should be accessed solely by people who are directly involved in emergency response. The PAD is the distance downwind of the source of the release within which persons should be either evacuated or sheltered in place, depending on the severity of the incident and the nature of the population (e.g., density, age, health).

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Evaluation of the Radioactive Material Release in the Harborview Research and Training Building and Implications for Emergency Response

On May 2, 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a Mobile Hot Cell (MHC) on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%) was released from the Mobile Hot Cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy's Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. The implications for emergency response are relevant to data quality and management. A Data Quality Objective (DQO) guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and sample archival.

61 RADIATION PROTECTION AND DOSIMETRY

A Software/Hardware Framework for Efficient and Safe Emergency Response in Post-Crash Scenarios of Battery Electric Vehicles

The adoption rate of battery electric vehicles (EVs) is rapidly increasing. Electric vehicles differ significantly from conventional internal combustion engine vehicles and vary widely across different manufacturers. Emergency responders (ERs) and recovery personnel may have less experience with EVs and lack timely access to critical information such as the extent of the stranded energy present, high-voltage safety hazards, and post-crash handling procedures in a user-friendly manner. This paper presents a software/hardware interactive tool named Electric Vehicle Information for Incident Response Solutions (EVIRS) to aid in the quick access to emergency response and recovery information. The current prototype of EVIRS identifies EVs using the VIN or Make, Model, and Year, and offers several useful features for ERs and recovery personnel. These features include integration and easy access to emergency response procedures tailored to an identified EV, vehicle structural schematics, the quick identification of battery pack specifications, and more. For EVs that are not severely damaged, EVIRS can perform calculations to estimate stranded energy in the EV’s battery and discharge time for various power loads using either EV dashboard information or operational data accessed through the CAN interface. Knowledge of this information may be helpful in the post-crash handling, management, and storage of an EV. The functionality and accuracy of EVIRS were demonstrated through laboratory tests using a 2021 Ford Mach-E and associated data acquisition system. The results indicated that when the remaining driving range was used as an input, EVIRS was able to estimate the pack voltage with an error of less than 3 V. Conversely, when pack voltage was used as an input, the estimated state of charge (SOC) error was less than 5% within the range of 30–90% SOC. Additionally, other features, such as retrieving emergency response guides for identified EVs and accessing lessons learned from archived incidents, have been successfully demonstrated through EVIRS for quick access. EVIRS can be a valuable tool for emergency responders and recovery personnel, both in action and during offline training, by providing crucial information related to assessing EV/battery safety risks, appropriate handling, de-energizing, transport, and storage in an integrated and user-friendly manner.

25 ENERGY STORAGE

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY

Comparison of Projections for a Short-Term Release, CAP88 vs NARAC

The purpose of this study was to compare the projected dose using different plume models, evaluating a short duration release of tritium to the 16 compliance sectors and 4 additional points of interest using local meteorology. This report is written as guidance to the decision makers when reviewing this specific Gaussian plume model intended for radiological dose assessment and regulatory compliance, called CAP88 1 , as compared to a more-complex model designed for emergency response. The emergency response model, NARAC 2 , can be used to supplement the CAP88 compliance model evaluations, since NARAC is intended for use in situations where releases are shorter in duration and have increased complexity in terrain and meteorology.

54 ENVIRONMENTAL SCIENCES

Towards the Flexibility of HVDC-Interconnected Systems: A Novel Emergency Freqeuncy Response Model

In this paper, we propose a novel multi-time scale emergency frequency response model by unlocking the flexibility of High Voltage Direct Current (HVDC) systems. Unlike assigning power ramping rates for FACTS to regulate frequency in traditional methods, this paper designs a step-change electromagnetic power frequency response (EPFR) scheme, by leveraging the temporal over/under DC voltage capability of HVDC. Wherein the Kullback-Leibler Divergence is adopted to convexify the modified swing equation after integrating the step-change power. Further, to avoid the complicated differential equations, we equivalently reformulate the duration limits of DC voltage deviation into the HVDC decreasing power ramping rates, which participate in the system primary frequency response. Finally, the new steady-state operation level of HVDC is involved with the secondary frequency response. As a result, an improved three-level algorithm is developed to solve the model, wherein the instant step-change, primary, and secondary frequency response are coordinated together. After applying the proposed frequency response scheme on the test system, the EPFR is validated to effectively provide the most instantaneous supports when faced with bulk power loss due to extreme contingencies, and the resilience is ensured within acceptable expenditures.

Jiang, Sufan

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY

Developing Source Term Database for Advanced Reactors

A source term database is crucial to informing nuclear emergency response measures, enabling emergency responders to assess the potential severity of nuclear and radiological consequences. In recent times, various advanced reactor designs have come into operation, are under construction, or are being designed and developed. This report documents an effort carried out to develop a source term database for advanced reactors. The report covers key design features of these reactors and discusses radioactivity buildup and source term inventories of dose-significant radionuclides in the reactor core. For neutronic and depletion analyses, we used the SCALE code system, a computational suite for reactor physics, depletion, criticality, and sensitivity/uncertainty quantification. We used SCALE/TRITON to perform depletion calculations to predict cycle length and discharge burnup and to generate the ORIGEN reactor library. Subsequently, we used SCALE/ORIGAMI to calculate radioactivity buildup and, thereby, the source term inventories at the targeted discharge burnup, using the ENDF/B-VII.1 nuclear data library. This report covers several advanced reactors, including the KLT-40S, RITM-200N, VOYGR, and eVinci. However, other reactors, such as the RITM-200S and ARC-100, have yet to be investigated and will be explored in future efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Sensitivity analysis of a parameterization of coagulation in an aqueous transport model

A three-dimensional aqueous transport model, ALGE, was developed at the Savannah River National Laboratory (SRNL) as a tool for emergency response. Recently, coagulation and break-up of sediment and particulate (contaminant adhered to sediment) matter has been added as a new model capability, representing both processes as functions of salinity and turbulence. A sensitivity analysis was performed by comparing time series of sediment and particulate concentrations at various locations when the model’s parameters (particle size and density) are altered. The results show significant differences between experiments in both freshwater and saltwater systems parameters vary (P-values < 0.05). From this sensitivity study, we have concluded the importance of incorporating both salinity and turbulent effects, as they have a large role in the physical process of coagulation and breakup of sediment. By accounting for these physical processes, we have made the ALGE model a more robust tool for emergency response.

Aqueous fate and transport

Spectra-to-exposure conversion using polynomial response models for gamma-ray field characterization

Accurate measurement of exposure rate from gamma-ray spectral data remains a critical challenge during radiological emergency response operations. Conventional methods rely on pre-defined static conversion factors derived from fixed geometries and isotopic compositions, which often fail to capture real-world environmental variability. This study presents a generalized approach as a "next-step" for converting gamma-ray spectral data into exposure rate using polynomial response models. The method introduces a flexible weighting scheme based on the in-situ detector response to distributed sources, enabling a pathway towards improved correspondence between measured spectra and "ground-truth" exposure rates. Experimental data from sodium iodide NaI(Tl) detectors were used to validate the approach as, at least equivalent to the current count-to-exposure method employed in emergency response CONOPS. Results show that the polynomial weighting model is sufficiently equal to the count-to-exposure method and may help improve accuracy given its adaptability to real-world conditions.

61 RADIATION PROTECTION AND DOSIMETRY

Whole-scene, one-sided backscatter x-ray imaging with coded apertures

X-ray radiography can be an important diagnostic for emergency response, providing timely diagnostic information about a suspect object. However, there are situations where similar information would be better obtained with a one-sided imaging technique. X-ray backscatter imaging is a proven technology that could provide such information, but current implementations have drawbacks that render it unsuitable for emergency response. We are exploring the use of coded-aperture imaging to create one-sided images, targeting a key benefit: implementation requiring minimal additional resources, bypassing logistics issues. We present results demonstrating the feasibility of this approach.

Ziock, Klaus-Peter [ORNL]

Rapid neutron and gamma-ray source localization using machine learning

Rapid localization of radiation sources is critical for applications including nuclear emergency response, safeguards, and security. However, conventional imaging systems such as neutron scatter cameras and Compton cameras depend on rare coincidence events, which often result in long acquisition times. In this work, we address the challenge of rapid source localization by developing a machine learning approach to predict the direction of a single radiation source using only count rates from an array of neutron and gamma-ray detectors. The proposed model is a fully connected neural network (FCNN) trained using Monte Carlo simulation data from a 252 Cf source. The model hyperparameters are optimized with a small set of routine 252 Cf measurements. We benchmarked the performance of the trained and optimized machine learning model using additional 252 Cf , 137 Cs , and PuBe measurements under laboratory conditions with varying source-detector configurations. For these measurements, the machine learning model achieved a mean localization error smaller than 30° with 3 x 10 3 system counts, corresponding to 8 s measurement time for the imaging system used in this work. In this low-statistics regime, the method outperformed traditional scatter-based imaging by more than 75% in localization accuracy for the evaluated measurement configurations. These results demonstrate that a machine learning-based approach can significantly reduce the time required for accurate single-source localization, providing a robust and computationally efficient alternative to traditional imaging systems in time-critical nuclear security and emergency response scenarios.

Gamma-ray imaging

Risk Analysis for Remote Operation of Microreactors

Microreactors are a subset of advanced nuclear reactors that can be factory fabricated, transportable, and self-regulating. They have the potential to be used in microgrids, rural and remote areas, or emergency response applications, replacing fossil fuel sources like diesel generators and enabling sustainable energy generation. In order to make microreactor operation cost-effective, it is likely that remote communications will be needed to reduce the number of personnel required to be on site. While remote operation of energy generation and other industrial control systems is common in other industries, it is not yet adopted in the nuclear community and has many perceived and actual risks. In this paper, the severity of the risks introduced by remote operations for microreactors are explored. The primary changes in the operations involve the addition of a remote communications network and a certification system for data and controls. These changes lend themselves to considerations of cyber risks, whether unintentional or adversarial, but the assessment considers not just cyber risks introduced, but also how physical and human factors-based risks will impact the remote operations system and change the overall risk profile. This initial assessment indicates that there are standard cyber and mitigation measures that can be put in place so the risk of doing remote operations does not dramatically increase compared to local operations. This evaluation is a critical step in the process of evaluating if remote operations of microreactors is a suitable solution to meet future sustainable grid needs

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling

Electromagnetic response and emergent topological orders in transition metal dichalcogenide MoTe 2 bilayers

Twisted bilayer transition metal dichalcogenides, such as MoTe 2 , provide a versatile platform for exploring correlated topological phases. This work investigates the interplay between perpendicular magnetic and electric fields in tuning the electronic structure and emergent topological orders of twisted bilayer MoTe 2 (t-MoTe 2 ) across two distinct regimes: a low-twist-angle phase (θ ≈ 2.1°) hosting multiple Chern bands of identical Chern numbers per valley, and a higher-angle phase (θ ≈ 3.89°) featuring Haldane-like bands with opposite Chern numbers. Using a continuum model incorporating moiré potentials up to second harmonics, we compute the Hofstadter fractal spectra under applied fields, revealing Landau fan structures and magnetic-flux-dependent band topology. These fractal spectra are useful in studying emergent topological orders in terms of the composite fermion picture, where the statistical Chern-Simons flux is approximated as a uniform gauge field. We demonstrate that the system hosts both Jain-sequence fractional Chern insulators (FCIs) and non-Jain fractal FCIs with higher Chern numbers. As a result, the electric field suppresses composite fermion gaps and induces topological quantum phase transitions. Furthermore, our analysis extends to valley-contrasting flux attachment, proposing pathways to describe fractional quantum spin Hall states.

Anyons

Consequence analyses of sabotage-induced radiological releases in high-temperature helium-cooled prismatic microreactors

Here, this study analyzes the radiological dose consequences of sabotage-induced accidents at three high-temperature helium-cooled prismatic microreactors (HTPMs) with thermal power ratings of 1, 10, and 50 MWt. Each HTPM employs uranium oxycarbide tristructural isotropic fuel enriched to 19.75 wt% high-assay low-enriched uranium. Simulations were conducted to estimate reactor core inventory at the point of fuel discharge––when the effective multiplication factor reduced to less than 1––representing peak radionuclide inventory. Postulated sabotage scenarios leading to reactor shutdown were analyzed at two intervals: immediately post-shutdown (0 h) and 3 days after shutdown using the SCALE code for radionuclide inventories and the RASCAL tool for dose consequences. Results show that although HTPMs benefit from inherent safety features and robust fuel design, radiological consequences scale with reactor power because of increased source term inventories. Smaller microreactors exhibited proportionally lower dose consequences. To support the economic and regulatory feasibility of microreactor deployment, this study emphasizes the value of a risk-informed, performance-based approach, as supported by regulations like 10 CFR Parts 100 and 53 in the United States. Microreactor developers should perform site-specific assessments of potential sabotage or low-probability, high-consequence events, especially when considering minimal on-site or full off-site emergency response.

Consequence