Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Beginner's Guide to Power and Energy Measurement and Estimation for Computing and Machine Learning

Concerns about the environmental footprint of machine learning are increasing. While studies of energy use and emissions of ML models are a growing subfield, most ML researchers and developers still do not incorporate energy measurement as part of their work practices. While measuring energy is a crucial step towards reducing carbon footprint, it is also not straightforward. This paper introduces the main considerations necessary for making sound use of energy measurement tools and interpreting energy estimates, including the use of at-the-wall versus on-device measurements, sampling strategies and best practices, common sources of error, and proxy measures. It also contains practical tips and real-world scenarios that illustrate how these considerations come into play. It concludes with a call to action for improving the state of the art of measurement methods and standards for facilitating robust comparisons between diverse hardware and software environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Specifying Calibration of Energy-Measuring Equipment

A report on calibrating energy-measuring equipment to maximize energy efficiency of lighting and other systems. The report describes best practices for accrediting calibration laboratories and for calibrating measuring equipment, compares and contrasts service providers accredited for energy-measuring equipment calibration, presents a tailorable specification template for requesting such calibration, and offers recommendations to a range of stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A measured energy use, solar production, and building air leakage dataset for a zero energy commercial building

This paper provides an open dataset of measured energy use, solar energy production, and building air leakage data from a 328 m 2 (3,531 ft 2 ) all-electric, zero energy commercial building in Virginia, USA. Over two years of energy use data were collected at 1-hour intervals using circuit-level energy monitors. Over six years of solar energy production data were measured at 1-hour resolution by 56 microinverters (presented as daily and monthly data in this dataset). The building air leakage data was measured post-construction per ASTM-E779 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization and the United States Army Corps (USACE) Building Enclosure Testing procedure; both pressurization and depressurization results are provided. The architectural and engineering (AE) documents are provided to aid researchers and practitioners in reliable modeling of building performance. The paper describes the data collection methods, cleaning, and convergence with weather data. This dataset can be employed to predict, benchmark, and calibrate operational outcomes in zero energy commercial buildings.

14 SOLAR ENERGY↗

Specifying Calibration of Energy-Measuring Equipment

Instruments and standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user expectations. This white paper reviews calibration terminology and standards, and describes best practices that have been developed for a) calibrating measurement equipment to ensure some known level of accuracy, and b) accrediting calibration service providers. Calibration is discussed in the context of metrological traceability, and excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently calibrate measuring equipment or who have new or changing needs for calibrating measuring equipment, rationale is provided for why a specification might be used to request calibration services that meet specific test needs. Given the growing interest in using data to manage the energy consumption of systems, and the increasing number and variety of systems (e.g., building, computing) that can report such information, use cases requiring energy data are used to facilitate further discussion and provide examples. Commercially available service providers who are accredited for energy-measuring equipment calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of energy-measuring-equipment test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

47 OTHER INSTRUMENTATION↗

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy↗

Time-of-Flight Calculations with Multiple Beam Phase Monitors: Calibration, Jitter Analysis & Energy Measurement

This report describes time-of-flight (ToF) beam energy measurements with multiple phase monitors in a beam line with no acceleration. Measurement uncertainty is quantified via rigorous treatment of beam-based phase monitor calibration and jitter analysis of the accelerator system. Experimental results in the Superconducting Linac (SCL) of the Spallation Neutron Source (SNS) are presented.

43 PARTICLE ACCELERATORS↗

Time-of-Flight Energy Measurements With BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed at Fermilab. The case when the flight time between BPMs is longer than the period of BPM frequency is considered in more detail. When absolute BPM phase calibration is not available, the BPM phase information can be used to track deviations of the beam energy from the de-sired value. Such energy deviation parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander V. [Fermilab] (ORCID:00000001↗

Time-of-Flight energy measurements with BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighboring Beam Position Monitors (BPMs). This report presents estimations on implementation of such a procedure at PIP-II H- linac being constructed at Fermilab. In part, the case when the flight time between BPMs is larger than the period of BPM frequency is considered in detail. When the absolute BPM phase calibration is not available, the BPM phase information can be used to trace deviations of the beam energy from the desired value. Such “energy deviation” parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501↗

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in X-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard X-ray TESs to measure the absolute energies of muonic-argon (R-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. Here, we achieved similar to 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Study on Fine-Grained Power and Energy Measurements on Grace Hopper GH200 with Open-Source Performance Tools

The increasing adoption of tightly integrated, heterogeneous architectures, combined with the slowdown of Moore’s law, has made application power and energy-driven optimizations critical to efficiently use high-performance computing systems. This paper introduces a newly developed open-source toolkit that seamlessly integrates the Linux real-time hardware monitoring program hwmon with the Performance Application Programming Interface and the Score-P performance measurement system, thereby enabling fine-grained power and energy measurements for high-performance computing applications. Our primary target platform is the Wombat test bed, which is a system based on the NVIDIA GH200 superchip. The toolkit can capture transient power peaks with high temporal resolution (50 ms) and, thanks to Score-P integration, can map power metrics to specific code regions, thereby providing actionable information on power-intensive operations and inefficiencies. The toolkit also provides a holistic view of both the power and the energy consumption of the entire GH200 superchip by covering all major components: the Grace CPU, the Hopper GPU, and the I/O subsystem. Experiments that use Locally Self-consistent Multiple Scattering, which is an application for first-principles calculations of materials developed at Oak Ridge National Laboratory, have demonstrated the tool’s ability to identify transient power spikes and uncover opportunities for energy-aware optimizations. Additionally, we introduce a Python-based utility for converting Open Trace Format 2 traces to Parquet format, thus enabling advanced data analysis for numerical integration methods applied to power data for accurate energy profiling.

Hernandez Mendoza, Oscar [ORNL] (ORCID:00000002538↗

Improving noisy free-energy measurements by adding more noise

Estimating free-energy differences using nonequilibrium work relations, such as the Jarzynski equality, is hindered by poor convergence when work fluctuations are large. For systems governed by overdamped Langevin dynamics, we propose the counterintuitive approach of adding noise in order to increase the precision of such calculations. Here, by introducing additional stochastic fluctuations to the system and rescaling its potential energy accordingly, we leave the thermodynamics of the system unchanged while increasing its relaxation rate. For a given time-dependent protocol this modification reduces the dissipated reduced work, leading to more accurate free-energy estimates. The method is designed to be used in experiment, and we illustrate its operation using computer simulations applied to two model systems. However, the regime of applicability of this strategy is likely limited, because it requires control of the system's potential energy in a way that is feasible in only a few experimental settings.

Whitelam, Stephen [Lawrence Berkeley National Labo↗

DARHT Axis 1 Time-Resolved Injector Energy Measurement

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

47 OTHER INSTRUMENTATION↗

Revealing hidden defects through stored energy measurements of radiation damage

With full knowledge of a material’s atomistic structure, it is possible to predict any macroscopic property of interest. In practice, this is hindered by limitations of the chosen characterization techniques. For example, electron microscopy is unable to detect the smallest and most numerous defects in irradiated materials. Instead of spatial characterization, we propose to detect and quantify defects through their excess energy. Differential scanning calorimetry of irradiated Ti measures defect densities five times greater than those determined using transmission electron microscopy. Our experiments also reveal two energetically distinct processes where the established annealing model predicts one. Molecular dynamics simulations discover the defects responsible and inform a new mechanism for the recovery of irradiation-induced defects. The combination of annealing experiments and simulations can reveal defects hidden to other characterization techniques and has the potential to uncover new mechanisms behind the evolution of defects in materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low-energy measurement of the 25 Mg ⁢(𝛼,𝑛)⁢ 28 Si reaction via neutron spectroscopy

During core helium and carbon burning in massive stars, neutrons are produced mainly by the 22 Ne⁢ (𝛼,𝑛) ⁢25 Mg reaction. Some of these released neutrons are captured by heavy seed nuclei from previous nucleosynthesis events, resulting in the slow production of many of the elements between masses 60 ≤ 𝐴 ≤ 90 via the weak 𝑠 process. Determining the overall neutron flux available in this environment is one of the main challenges in modeling its contributions to heavy element production. Not only must the reaction rate be well defined for the primary neutron source, but the rates of neutron poison and recycling reactions must also be well determined. One critical reaction in the simulation network is 25 Mg ⁢(𝛼,𝑛) ⁢ 28 Si. This reaction, together with 25 Mg ⁢(𝑛,𝛾)⁢ 26 Mg and 25 Mg⁢ (𝛼,𝛾) ⁢ 29 Si, determine how 25 Mg nuclei affect the available neutron flux. Past attempts to measure the 25 Mg ⁢(𝛼,𝑛)⁢ 28 Si cross section using neutron moderator counters have been greatly hindered by lower-𝑍 background reactions. Here, in the present work, neutron spectroscopy with deuterated liquid scintillator detectors has been used. The experimental spectra have been analyzed by applying spectrum unfolding techniques to achieve improved background discrimination for the 25 Mg⁢ (𝛼,𝑛)⁢ 28 Si reaction at low energies, down to 𝐸 𝛼 = 1.75 MeV. The separation of the different background contributions gives further insight into the results of previous moderator counter measurements and the measurements lead to a revised and more reliable determination of the reaction rate.

hydrostatic stellar nucleosynthesis↗

Enabling Dark Energy Measurements from DESI and LSST (Final Technical Report)

This grant enabled efforts to lead the Survey Validation of the Luminous Red Galaxy (LRG) sample for DESI, entailing intensive work to prepare target samples, test their performance with DESI data, and validate that the requirements of the survey for this key sample are met. Luminous Red Galaxies represent the gold standard target class for Baryon Acoustic Observation experiments to study Dark Energy. It also funded work to co-leading the Follow-up Task Force within the LSST Dark Energy Science Collaboration (LSST DESC), which is intended to help develop collaborations with external groups and to produce cross-working group proposals for telescope time, policy proposals and white papers as needed in order to help the collaboration obtain and make use of complementary data which will strengthen LSST Dark Energy constraints. The PI has been particularly engaged in efforts to obtain access to spectroscopic training sets for LSST photometric redshifts in the first years of the survey, which requires developing relationships with groups that are obtaining such data for other purposes. This group has evolved into an External Synergies working group within DESC, also co-led by the PI. These groups have developed white papers for Astro2020, letters of intent and white papers for Snowmass2021, and a response to a DOE-NASA RFI. It also has enabled smaller contributions to improving LSST DESC pipeline infrastructure for photometric redshifts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of hot water end-use process of electric water heaters from energy measurements

This paper presents an algorithm for the identification of parameters for a stochastic hot water end-use process that drives a homogeneous population of thermostatically controlled electric water heaters (EWH). Usually, only metered interval consumption data (kWh) is collected and the hot water end-use process is unobservable to utility and aggregators. However, the availability of EWHs for demand response (DR) is closely coupled with the hot water end-use process. In this context, the hot water end-use process is modeled as a two-state Markov chain (Use / No use), which causes the thermostatic ON-OFF switching process to behave as a Markov renewal process (MRP). A set of first passage-time problems is developed to obtain the moments of the transition probability densities of the MRP. These problems are addressed by establishing a system of coupled partial differential equations characterizing the temperature evolution of the EWH population. A key quantity in the methodology for estimating the parameters is the total time an EWH is ON within a period of interest. It is referred to as the total busy time. Total busy time in this approach is a random variable for which analytical expressions of the moments are developed as a function of the metered window length. The latter expressions become the basis of a hot water demand model identification algorithm which is validated using agent-based simulations of EWHs.

42 ENGINEERING↗