Nowcasting, predictive control, and feedback control for temperature regulation in a novel hybrid solar-electric reactor for continuous solar-thermal chemical processing

A novel 15 kW reactor for the hybridization of concentrated solar and conventional electric heat was fabricated for renewable and continuous chemical processing at temperatures up to 1700 °C. Solar-electric controllers based on feedback or predictive linear models were used to regulate the device at 925 °C for the production of syngas via the gasification of carbon. The system was challenged with cloud transients programmed on a 45 kW high-flux solar simulator that approximated weather observed in the San Luis Valley (Colorado, USA). In experiment it was found that model predictive control with a 1 min ahead nowcast of incipient clouding best regulated solar-electric reactor temperatures, potentially averting thermal fatigue. Upon clouding, model predictive control with a nowcast yielded temperature disturbances of ±10 °C, whereas feedback control alone featured ±25 °C excursions. Overall, the performance of model predictive control with a nowcast was 75% better than feedback as indicated by the integral squared error of temperature excursion residuals. The importance of nowcast accuracy was explored, and although the model-based controller was robust to forecast amplitude inaccuracy, temporal forecast inaccuracy wholly negated the benefits of predictive control.

14 SOLAR ENERGY↗

Real-time radiative divertor feedback control development for the NSTX-U tokamak using a vacuum ultraviolet spectrometer

A radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature T{sub e} estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPherson Model 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the Δn = 0, 1 line intensity ratios of carbon, nitrogen, or neon ion lines in the spectral range 300–1600 Å. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time T{sub e}-dependent signal within a characteristic divertor detachment equilibration time of ∼10–15 ms is expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Efficient Numerical Algorithm for Solving Data Driven Feedback Control Problems

The goal of this paper is to solve a class of stochastic optimal control problems numerically, in which the state process is governed by an Itô type stochastic differential equation with control process entering both in the drift and the diffusion, and is observed partially. The optimal control of feedback form is determined based on the available observational data. In this work, we call this type of control problems the data driven feedback control. The computational framework that we introduce to solve such type of problems aims to find the best estimate for the optimal control as a conditional expectation given the observational information. To make our method feasible in providing timely feedback to the controlled system from data, we develop an efficient stochastic optimization algorithm to implement our computational framework.

97 MATHEMATICS AND COMPUTING↗

FIRST BEAM TESTS OF THE APS MBA UPGRADE ORBIT FEEDBACK CONTROLLER

The new orbit feedback system required for the APS multi-bend acromat (MBA) ring must meet challenging beam stability requirements. The AC stability requirement is to correct rms beam motion to 10 % the rms beam size at the insertion device source points from 0.01 to 1000 Hz. The vertical plane represents the biggest challenge for AC stability which is required to be 400 nm rms for a 4 micron vertical beam size. In addition long term drift over a period of 7 days is required to be 1 micron or less at insertion de- vice BPMs and 2 microns for arc bpms. We present test re- sults of theMBA prototype orbit feedback controller (FBC) in the APS storage ring. In this test, four insertion device BPMs were configured to send data to the FBC for process- ing into four fast corrector setpoints. The configuration of four bpms and four fast correctors creates a 4-bump and the configuration of fast correctors is similar to what will be implemented in the MBA ring. We report on performance benefits of increasing the sampling rate by a factor of 15 to 22.6 kHz over the existing APS orbit feedback system, lim- itations due to existing storage ring hardware and extrapo- lation to theMBA orbit feedback design. FBC architecture, signal flow and processing design will also be discussed.

Sereno, N. S.↗

Multi-resonant feedback control of a single degree-of-freedom wave energy converter

A multi-resonant wide band controller decomposes the wave energy converter control problem into sub-problems; an independent single-frequency controller is used for each sub-problem. Thus, each sub-problem controller can be optimized independently. The feedback control enables actual time-domain realization of multi-frequency complex conjugate control. The feedback strategy requires only measurements of the buoy position and velocity. No knowledge of excitation force, wave measurements, nor wave prediction is needed. As an example, the feedback signal processing can be carried out using Fast Fourier Transform with Hanning windows and optimization of amplitudes and phases. Given that the output signal is decomposed into individual frequencies, the implementation of the control is very simple, yet generates energy similar to the complex conjugate control.

Wilson, David G.↗

Advocating Feedback Control for Human-Earth System Applications

This paper proposes a feedback control perspective for Human-Earth Systems (HESs) which essentially are complex systems that capture the interactions between humans and nature. Recent attention in HES research has been directed towards devising strategies for climate change mitigation and adaptation, aimed at achieving environmental and societal objectives. However, existing approaches heavily rely on HES models, which inherently suffer from inaccuracies due to the complexity of the system. Moreover, overly detailed models often prove impractical for optimization tasks. We propose a framework inheriting from feedback control strategies the robustness against model errors, because inaccuracies are mitigated using measurements retrieved from the field. The framework comprises two nested control loops. The outer loop computes the optimal inputs to the HES, which are then implemented by actuators controlled in the inner loop. Potential fields of applications are also identified and a numerical example is provided.

biological system modeling↗

Feedback Control Strategy for Transient Stability Application

Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine learning-based ethylene and carbon monoxide estimation, real-time optimization, and multivariable feedback control of an experimental electrochemical reactor

Electrochemical reduction of CO 2 gas is a novel CO 2 utilization technique that has the potential to mitigate the global climate crisis caused by anthropogenic CO 2 emissions, and enable the large-scale storage of energy generated from renewable sources in the form of carbon-based chemicals and fuels. However, due to the complexity of the electrochemical reactions, the explicit first-principles models for CO2 reduction are not available yet, and there has been a limited effort to develop process modeling, optimization and control of CO 2 electrochemical reactors. To this end, a rotating cylinder electrode (RCE) reactor has been constructed at UCLA to understand the mass transfer and reaction kinetics effects separately on the productivity. In the RCE reactor, the applied potential strongly influences the reaction energetics and the electrode rotation speed affects the hydrodynamic boundary layer and modifies the film mass transfer coefficient, which involves convective and diffusive transport. Further, the present work aims to develop a multi-input multi-output (MIMO) control scheme for the RCE reactor that integrates techniques from artificial and recurrent neural network modeling, nonlinear optimization, and process controller design. Specifically, production rates of two products from the experimental reactor, ethylene and carbon monoxide, are controlled by manipulating two inputs, applied potential and catalyst rotation speed. Process dynamics and controllability are analyzed, a feedback control strategy is designed and the controllers are tuned accordingly. The experimental electrochemical cell is employed to gather data for process modeling and implement the multivariable control system. Finally, the experimental results are presented which demonstrate excellent closed-loop performance by the control system and regulation of the outputs at three different set-points including an economically-optimal set-point.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Convergence Analysis for an Online Data-Driven Feedback Control Algorithm

This paper presents convergence analysis of a novel data-driven feedback control algorithm designed for generating online controls based on partial noisy observational data. The algorithm comprises a particle filter-enabled state estimation component, estimating the controlled system’s state via indirect observations, alongside an efficient stochastic maximum principle-type optimal control solver. By integrating weak convergence techniques for the particle filter with convergence analysis for the stochastic maximum principle control solver, we derive a weak convergence result for the optimization procedure in search of optimal data-driven feedback control. Numerical experiments are performed to validate the theoretical findings.

97 MATHEMATICS AND COMPUTING↗

Full State Feedback Control for Virtual Power Plants

This report presents an object-oriented implementation of full state feedback control for virtual power plants (VPP). The components of the VPP full state feedback control are (1) objectoriented high-fidelity modeling for all devices in the VPP; (2) Distribution System Distributed Quasi-Dynamic State Estimation (DS-DQSE) that enables full observability of the VPP by augmenting actual measurements with virtual, derived and pseudo measurements and performing the Quasi-Dynamic State Estimation (QSE) in a distributed manner, and (3) automated formulation of the Optimal Power Flow (OPF) in real time using the output of the DS-DQSE, and solving the distributed OPF to provide the optimal control commands to the DERs of the VPP.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Filtering adaptive output feedback control for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics

This article synthesizes a filtering adaptive output feedback controller for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics. The multivariable nonlinear systems under consideration have both matched and mismatched uncertainties, which satisfy the semiglobal Lipschitz condition. The unmodeled dynamics are bounded-input bounded-output stable. By adopting an estimation/cancellation strategy, a piecewise constant adaptive law drives the estimation error to zero at every time instant, which yields the adaptive parameters; a disturbance rejection control law is designed to compensate the nonlinear uncertainties within the bandwidth of low-pass filters. The matched uncertainties are cancelled directly by adopting their opposite in the control signal, while a dynamic inversion of the system is required to eliminate the effect of the mismatched uncertainties on the output. A feedforward control law is designed to track a given command. Since the virtual reference system defines the best performance that can be achieved by the closed-loop system, the uniform performance bounds are derived for the states and control signals via comparison. Both numerical and practical examples are provided to illustrate the effectiveness of the proposed filtering adaptive output feedback control architecture, comparisons with the model reference adaptive control demonstrates the superiority of the proposed control method.

filtering adaptive control, mismatched uncertainit↗

First feedback-controlled divertor detachment in W7-X: Experience from TDU operation and prospects for operation with actively cooled divertor

In the last experimental campaign (OP1.2b) of the stellarator Wendelstein 7-X (W7-X), boronisation as a mean for first wall conditioning was applied for the first time which led to strongly reduced impurity fluxes from plasma-facing components. Thermal detachment at the uncooled target plates of the test divertor unit (TDU) was reached at higher plasma densities and was accompanied by high recycling of neutrals at the target plate. A feedback control system was established in W7-X to actively control the gas injection (actuator) for plasma fuelling and impurity seeding [3] through the divertors. It allowed very successful stabilisation of the detached plasma condition state as well as mitigation of thermal overloads to some baffle tiles. Different routinely available diagnostic signals were used as input parameters (sensors). We describe the setup of the feedback control system, its performance and provide some example results with the main focus on the development of the control scheme which led to the detachment stabilisation over the entire longest (30 s) high-power discharge at W7-X so far. In view of the achieved very successful detachment stabilisation and the necessity to include simultaneous optimisation of the core performance in the future, the feedback control system is being upgraded for the upcoming campaign (OP2.1) in which the water cooled and hereby inherently steady-state capable divertor has been currently installed. The prospects and some experiment ideas for active detachment control are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feedback Control Approaches for Restoration of Power Grids from Blackouts

The automated restoration of power systems with variable energy resources is a timely problem to tackle. Automated restoration advice can support operators in deciding on strategic actions to restore power grids from a blackout with a mix of conventional and renewable generation resources. To this end, this paper frames the restoration process of power grids with solar resources as a nonlinear dynamic model with algebraic constraints in discrete time which is steered by feedback control loops. We discuss two feedback-control strategies based on greedy and reinforcement learning algorithms, and contrast their performance with restoration plans generated by a mixed-integer linear program. We found that the reinforcement learning algorithm infers restoration actions faster than the greedy one. However, the tuning process of the reinforcement learning parameters is slower than for the greedy one.

machine learning↗

Multiresonant Feedback Control of a Three-Degree-of-Freedom Wave Energy Converter

For a three-degree-of-freedom wave energy converter (heave, pitch, and surge), the equations of motion could be coupled depending on the buoy shape. This paper presents a multiresonant feedback control, in a general framework, for this type of a wave energy converter that is modeled by linear time invariant dynamic systems. The proposed control strategy finds the optimal control in the sense that it computes the control based on the complex conjugate criteria. This control strategy is relatively easy to implement since it is a feedback control in the time domain that requires only measurements of the buoy motion. Numerical tests are presented for two different buoy shapes: a sphere and a cylinder. Regular, Bretschnieder, and Ochi-Hubble waves are tested. Simulation results show that the proposed controller harvests energy in the pitch-surge-heave modes that is about three times the energy that can be harvested using a heave-only device. In conclusion, this multiresonant control can also be used to shift the energy harvesting between the coupled modes, which can be exploited to eliminate one of the actuators while maintaining about the same level of energy harvesting.