At least 19 records

DC Link Capacitor Reduction with Feedforward Control in Series-Series Compensated Wireless Power Transfer Systems

This paper presents the use of feedforward control to reduce the input side DC link capacitance of series-series compensated wireless power transfer (WPT) systems. Compared to conventional control schemes for WPT systems, the proposed feedforward-based approach achieves significant reduction in the DC link capacitor without any complicated voltage or current sensing requirements from the secondary side. This results in more compact hardware architecture. The proposed method shows minimal increase in the turn-on switching loss of the inverter. The switching loss is analyzed, and detailed results are presented relating the switching loss to the DC link capacitance and voltage ripple for proper tradeoff between losses and capacitor size. Simulation and experimental results presented validate the proposed scheme.

Mukherjee, Subho↗

Vector-level feedforward control of LPBF melt pool area using a physics-based thermal model

Laser powder bed fusion (LPBF) is an additive manufacturing technique that has gained popularity thanks to its ability to produce geometrically complex, fully dense metal parts. However, these parts are prone to internal defects and geometric inaccuracies, stemming in part from variations in the melt pool. Here, this paper proposes a novel vector-level feedforward control framework for regulating melt pool area in LPBF. By decoupling part-scale thermal behavior from small-scale melt pool physics, the controller provides a scale-agnostic prediction of melt pool area and efficient optimization over it. This is done by operating on two coupled lightweight models: a finite-difference thermal model that efficiently captures vector-level temperature fields and a reduced-order, analytical melt pool model. Each model is calibrated separately with minimal single-track and 2D experiments, and the framework is validated on a complex 3D geometry in both Inconel 718 and 316L stainless steel. Results showed that feedforward vector-level laser power scheduling reduced geometric inaccuracy in key dimensions by 62%, overall porosity by 16.5%, and photodiode root-mean-squared deviation by 38.5% on average. Overall, this modular, data-efficient approach demonstrates that proactively compensating for known thermal effects can significantly improve part quality while remaining computationally efficient and readily extensible to other materials and machines.

Additive manufacturing↗

Insensitivity to propagation timing in a preview-enabled wind turbine control experiment

Lidar scanners are capable of taking measurements of a wind field upstream of a wind turbine. The wind turbine controller can use these measurements as a “preview” of future disturbances impacting the turbine. Such preview-enabled (or feedforward) controllers show superior performance to standard wind turbine control configurations based purely on a feedback architecture. To capitalize on the performance improvements that preview wind measurements can provide, feedforward control actions should be timed to coincide with the arrival of the wind field at the wind turbine location. However, the time of propagation of the wind field between the lidar measurement location and the wind turbine is not perfectly known. Moreover, the best time to take feedforward control action may not perfectly coincide with the true arrival time of the wind disturbance. This contribution presents results from an experiment where preview-enabled model predictive control was deployed on a fully-actuated, scaled model wind turbine operating in a wind tunnel testbed. In the study, we investigate the sensitivity of the controller performance to the assumed propagation delay using a range of wind input sequences. We find that the preview-enabled controller outperforms the feedback only case across a wide range of assumed propagation delays, demonstrating a level of robustness to the time alignment of the incoming disturbances.

17 WIND ENERGY↗

Fast model-based scenario optimization in NSTX-U enabled by analytic gradient computation

Model-based optimization offers a systematic approach to advanced scenario planning. In this case, the feedforward-control inputs (actuator trajectories) that are needed to attain and sustain a desired scenario are obtained by solving a nonlinear constrained optimization problem. This class of problems generally minimize a cost function that measures the difference between desired and actual plasma states. Several numerical optimization algorithms, such as sequential quadratic programming, require repeated calculation of the cost function gradients with respect to the input trajectories. Calculating these gradients numerically can be computationally intensive, increasing the time needed to solve the feedforward-control optimization problem. Here, this work introduces a method to analytically calculate these cost function gradients from the current profile evolution model. This can significantly reduce the computational time and allow for fast feedforward-control optimization, which would eventually enable optimal scenario planning between discharges. The performance of the feedforward optimizer with analytical gradients is compared to a traditional optimization algorithm based on numerical gradients for different NSTX-U scenarios. The plasma dynamics in the optimization algorithm are simulated using the Control Oriented Transport SIMulator (COTSIM). Results of the work show that analytical gradients consistently reduce the computation time while achieving trajectories that are comparable to those obtained by traditional optimization algorithms based on numerical gradients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The case for digital twins in metal additive manufacturing

The digital twin (DT) is a relatively new concept that is finding increased acceptance in industry. A DT is generally considered as comprising a physical entity, its virtual replica, and two-way digital data communications in-between. Its primary purpose is to leverage the process intelligence captured within digital models—or usually their faster-solving surrogates—towards generating increased value from the physical entities. The surrogate models are created using machine learning based on data obtained from the field, experiments and digital models, which may be physics-based or statistics-based. Anomaly detection and correction, and diagnostic closed-loop process control are examples of how a process DT can be deployed. In the manufacturing industry, its use can achieve improvements in product quality and process productivity. Metal additive manufacturing (AM) stands to gain tremendously from the use of DTs. This is because the AM process is inherently chaotic, resulting in poor repeatability. However, a DT acting in a supervisory role can inject certainty into the process by actively keeping it within bounds through real-time control commands. Closed-loop feedforward control is achieved by observing the process through sensors that monitor critical parameters and, if there are any deviations from their respective optimal ranges, suitable corrective actions are triggered. The type of corrective action (e.g. a change in laser power or a modification to the scanning speed) and its magnitude are determined by interrogating the surrogate models. Because of their artificial intelligence (AI)-endowed predictive capabilities, which allow them to foresee a future state of the physical twin (e.g. the AM process), DTs proactively take context-sensitive preventative steps, whereas traditional closed-loop feedback control is usually reactive. Apart from assisting a build process in real-time, a DT can help with planning the build of a part by pinpointing the optimum processing window relevant to the desired outcome. Again, the surrogate models are consulted to obtain the required information. In this article, we explain how the application of DTs to the metal AM process can significantly widen its application space by making the process more repeatable (through quality assurance) and cheaper (by getting builds right the first time).

36 MATERIALS SCIENCE↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Design Considerations of DC/DC Regulator for High-Power Dynamic Wireless Charging Systems

Due to fast fluctuating input voltage, dynamic wireless charging requires a post-regulator stage for battery charging control and management. This regulator stage has a high requirement on efficiency, size as well as control performance to ensure tight regulation and fast trainset. This paper addresses the control challenges by modeling the system and designing the compensator with input voltage feedforward control. In addition, high resolution PWM is implemented to improve transient performance and current balancing among the phases. Experimental results prove the effectiveness of the proposed schemes and validates 180 kW closed-loop 4-phase operation at 99% efficiency.

Xue, Lincoln↗

A signal compensation based cascaded PI control for an industrial heat exchange system

Since the characteristics of the industrial heat exchange system (HES) are drastically affected by variations of the steam pressure, ambient temperature and water quality, it is difficult for the classical cascade PI control system to meet the desirable control objectives. Therefore, in this paper, a deterministic linear model with unmodeled dynamics is used to describe the dynamic characteristics of the HES. It should be noted that the unmodeled dynamics at the previously sampled instant can be calculated using actual measurements and that the tracking error, which includes effects of the rate of changes of unmodeled dynamics on the controlled model, can be accurately determined. An additional compensating signal is obtained with the feedforward control together with a one-step optimal control law. Consequently, the cascade PI control strategy with the signal compensation is established. Furthermore, the simulation and industrial application show that the proposed method can effectively improve the performance of the cascade PI control system, especially when the unmodeled dynamics is subjected to unknown variations.

42 ENGINEERING↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Filtering adaptive output feedback control for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics

This article synthesizes a filtering adaptive output feedback controller for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics. The multivariable nonlinear systems under consideration have both matched and mismatched uncertainties, which satisfy the semiglobal Lipschitz condition. The unmodeled dynamics are bounded-input bounded-output stable. By adopting an estimation/cancellation strategy, a piecewise constant adaptive law drives the estimation error to zero at every time instant, which yields the adaptive parameters; a disturbance rejection control law is designed to compensate the nonlinear uncertainties within the bandwidth of low-pass filters. The matched uncertainties are cancelled directly by adopting their opposite in the control signal, while a dynamic inversion of the system is required to eliminate the effect of the mismatched uncertainties on the output. A feedforward control law is designed to track a given command. Since the virtual reference system defines the best performance that can be achieved by the closed-loop system, the uniform performance bounds are derived for the states and control signals via comparison. Both numerical and practical examples are provided to illustrate the effectiveness of the proposed filtering adaptive output feedback control architecture, comparisons with the model reference adaptive control demonstrates the superiority of the proposed control method.

filtering adaptive control, mismatched uncertainit↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Feedforward-feedback ammonia control at a water resource recovery facility based on a digital twin with hybrid model

Ammonia-based aeration control (ABAC) at full-scale Water Resource Recovery Facilities (WRRFs) can be challenged by diurnal loading and transport delays. This work addressed these challenges using a hybrid feedforward–feedback controller built on Activated Sludge Model 1 (ASM1), marking the first full-scale deployment to pair a mechanistic feedforward core with data-driven corrections. The objectives were to improve ammonia setpoint tracking, assess performance of the mechanistic model when enhanced with data-driven corrections, and document full-scale operation. The hybrid model incorporates two data-driven components: (1) a Mechanistic Error Forecasting Engine (MEFE), consisting of a multivariate linear regressor and a long short-term memory (LSTM) ensemble. Defying expectations, low-parameter models outperformed more complex alternatives, reducing the mechanistic error by 71%. (2) A Residual Oscillation Forecasting Engine (ROFE), based on Fast Fourier Transform, reduced the remaining error by another 35%. Two proportional–integral (PI) feedback loops further (i) trim the feedforward output and (ii) eliminate residual controller error in the final aerobic zone. In full-scale operation, the controller reduced mean-squared error (MSE) by 94% over the baseline and produced more stable dissolved oxygen (DO) setpoints. Overall, it was proven that layering multi-timescale data-driven models on a mechanistic core can yield reliable ABAC performance at WRRFs.

54 ENVIRONMENTAL SCIENCES↗

Thermal Response of a Lithium Vapor Divertor to Cyclical Operation

The lithium vapor divertor concept is being developed as a method to achieve detached divertor conditions in a tokamak while minimizing impurity radiation losses from the core plasma. SOLPS-ITER modeling has previously been used to identify some of the geometric constraints and required lithium evaporation rate of a lithium vapor divertor in a medium-sized tokamak during steady-state operation. Here an updated conceptual design based on these operating requirements is introduced and the thermal response of the system is modeled during cyclical operation, consistent with operation in a short-pulse tokamak. Controllability of the temperature of the lithium capillary porous system (CPS) is achieved by adopting a design where there is no line-of-sight for radiation from the plasma to reach the heated CPS surface. Operational strategies to minimize the amount of lithium evaporated between plasma discharges while achieving steady evaporation rates during plasma discharges are discussed and modeled here. The optimal feedforward control strategy demonstrated in this work is to ramp up the temperature of the evaporator as quickly as possible immediately before a plasma discharge and then reduce the heating to match the desired steady-state net evaporation rate just before the plasma discharge begins, allowing the thermal inertia of the system to stabilize the evaporation rate during the first second of the plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗