Search NASA⌕ Search

SEARCH · Search NASA

Results for “flexible printed circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Adhesively Bonded Copper and Polyimide for Flexible Printed Circuit Boards: A Data-Driven Degradation Study Under Accelerated Aging

The long-term durability of polyimide laminated adhesive based flexible printed circuit boards (PCBs) is critical to the microelectronics industry. The interface of the adhesive layer binding the polyimide and copper layers is particularly vulnerable since decreased bonding strength can lead to deadhesion, performance loss, and premature device failure. Here, in this study, adhesive-bonded polyimide and copper samples are subjected to 1000 h of damp heat exposure (85 °C/85%RH) to evaluate the impact of moisture and copper inclusion on the adhesive bonding performance. Significant copper diffusion through the adhesive layer is observed, which, combined with moisture uptake, is found to substantially weaken interfacial adhesion in copper-containing samples, thereby reducing device lifetime. Observed surface and bulk material changes are correlated to adhesion strength using the network structural equation modeling (netSEM) approach, resulting in a robust predictive model of performance degradation based on measurable materials properties.

Chemistry↗

Superconducting Multilayer High-Density Flexible Printed Circuit Board for Very High Thermal Resistance Interconnections

We have successively developed two superconducting flexible PCBs for cryogenic applications. The first one is monolayer, includes 552 tracks (10 µm wide, 20 µm spacing), and receives 24 wire-bonded integrated circuits. The second one is multilayer, with one track layer between two shielding layers interconnected by microvias, includes 37 tracks, and can be interconnected at both ends by wire bonding or by connectors. The first cold measurements have been performed and show good performances. The novelty of these products is, for the first one, the association of superconducting materials with very narrow pitch and bonded integrated circuits and, for the second one, the introduction of a superconducting multilayer structure interconnected by vias which is, to our knowledge, a world-first.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resistance of The Flex-Wire Windings

In this paper, an analysis of the flexible printed circuit board (FPCB) windings is performed. A one-dimensional model of the flex-wire winding is introduced and an equation for the FPCB ac winding resistance is derived. Experimental verification of derived equations is performed, i.e., impedance and power loss measurements.

Wojda, Rafal↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of a Multi-Rotor Triboelectric Nanogenerator Using a Modular Flexible Circuit Board Stack

Triboelectric nanogenerators (TENGs) are a nascent class of energy harvester that are being explored for scavenging energy from small ocean waves. To date, they have been integrated in wave energy converters (WECs) designed to capture random motion caused by the perturbations of the ocean surface. Blue economy applications such as ocean observation can benefit greatly from more substantial wave-derived power, as such, the power output of existing TENG WECs must be increased several-fold to become viable. This study describes the conceptualization of a rotary TENG, and the subsequent efforts to increase its power output by stacking multiple stator and rotor pairs. In the latter part of this study, we introduce a novel means of incorporating a friction element into the design of the TENG by employing flexible printed circuit board (PCB) rotors. At rest, these flexible rotors will contact the stator, building static charges due to friction, at speed, these flexible rotors will be decoupled from the stator, reducing friction and allowing faster rotation. Initial results indicate that the power output of the flexible PCB rotor does not produce more power than a rigid, acrylic disk rotor, however the current output of the prototype is boosted, and the prototype is far more compact, allowing for a higher energy density than the rigid rotor prototype.

bench testing↗

Flexible PCB Windings Size Optimization for Winding AC Resistance Minimization Under the Sinusoidal Voltage Regime

In this paper, optimization of the winding AC resistance of the flexible printed circuit board (FPCB) wire windings is performed. A one-dimensional model of the FPCB winding is introduced and an equation for the FPCB winding AC resistance and its low and medium frequency approximation are derived. The approximate FPCB winding AC resistance equation is used to derive optimum thickness of the FPCB winding conductor thickness at which minimum of winding AC resistance (global optimum) is achieved. The Finite Element Method analysis and experimental verification of derived equations (winding resistance, impedance, power loss, and temperature measurements) is performed in order validate derived model and winding resistance equation.

42 ENGINEERING↗

A laser printing based approach for printed electronics

Here we report a study of printing of electronics using an office use laser printer. The proposed method eliminates those critical disadvantages of solvent-based printing techniques by taking the advantages of electroless deposition and laser printing. The synthesized toner acts as a catalyst for the electroless copper deposition as well as an adhesion-promoting buffer layer between the substrate and deposited copper. The easy metallization of printed patterns and strong metal-substrate adhesion make it an especially effective method for massive production of flexible printed circuits. The proposed process is a high throughput, low cost, efficient, and environmentally benign method for flexible electronics manufacturing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intrinsic thermal interfacial resistance measurement in bonded metal–polymer foils

Heat conduction through bonded metal–polymer interfaces often limits the overall heat transfer in electronic packaging, batteries, and heat recovery systems. To design the thermal circuit in such systems, it is essential to measure the thermal interfacial resistance (TIR) across ~1 µm to 100 µm junctions. Previously reported TIR of metal–polymer junctions utilize ASTM E1530-based two-block systems that measure the TIR by applying pressure across the interface through external heating and cooling blocks. Here, we report a novel modification of the ASTM-E1530 technique that employs integrated heaters and sensors to provide an intrinsic TIR measurement of an adhesively bonded metal–polymer junction. We design the measurement technique using finite element simulations to either passively suppress or actively compensate the lateral heat diffusion through the polymer, which can minimize the systematic error to ≲5%. Through proof-of-concept experiments, we report the TIR of metal–polymer interfaces made from DuPont’s Pyralux double-side copper-clad laminates, commonly used in flexible printed circuit boards. Our TIR measurement errors are <10%. We highlight additional sources of errors due to non-idealities in the experiment and discuss possible ways to overcome them. Our measurement technique is also applicable to interfaces that are electrically insulating such as adhesively joined metal–metal junctions and sputter-coated or welded metal–polymer junctions. Altogether, the technique is capable of measuring TIR ≳10 –5 m 2 KW –1 in bonded metal–polymer foils and can be tailored for in situ measurements in flexible electronics, circuit packaging, and other hybrid metal–polymer systems.

47 OTHER INSTRUMENTATION↗

MO-F-CAMPUS-J-03: Development of a Human Brain PET for On-Line Proton Beam-Range Verification

Purpose: To develop a prototype PET for verifying proton beam-range before each fractionated therapy that will enable on-line re-planning proton therapy. Methods: Latest “edge-less” silicon photomultiplier arrays and customized ASIC readout electronics were used to develop PET detectors with depth-of-interaction (DOI) measurement capability. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together to form a large detector panel. Detectors with 1.5×1.5 and 2.0×2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables or PCB board to dedicated ASIC front-end electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition of coincidence events and data transfer. The modular detector and scalable electronics/data acquisition will enable flexible PET system configuration for different imaging geometry. Results: Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ∼18% and 2.8 ns energy and timing resolutions, and around 2–3 mm DOI resolution. A small prototype PET scanner with one detector ring has been built and evaluated, validating the technology and design. A large size detector panel has been fabricated by scaling up from modular detectors. Different designs of resistor and capacitor based signal multiplexing boards were tested and selected based on optimal crystal identification and timing performance. Stackable readout electronics boards and FPGA-based data acquisition boards were developed and tested. A brain PET is under construction. Conclusion: Technology of large-size DOI detector based on SiPM array and advanced readout has been developed. PET imaging performance and initial phantom studies of on-line proton beam-range measurement will be conducted and reported. NIH grant R21CA187717; Cancer Prevention and Research Institute of Texas grant RP120326.

60 APPLIED LIFE SCIENCES↗

A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca 2+ and pH

Homeostasis of ionized calcium in biofluids is critical for human biological functions and organ systems. Measurement of ionized calcium for clinical applications is not easily accessible due to its strict procedures and dependence on pH. pH balance in body fluids greatly affects metabolic reactions and biological transport systems. Here, we demonstrate a wearable electrochemical device for continuous monitoring of ionized calcium and pH of body fluids using a disposable and flexible array of Ca 2+ and pH sensors that interfaces with a flexible printed circuit board. This platform enables real-time quantitative analysis of these sensing elements in body fluids such as sweat, urine, and tears. Accuracy of Ca 2+ concentration and pH measured by the wearable sensors is validated through inductively coupled plasma-mass spectrometry technique and a commercial pH meter, respectively. Our results show that the wearable sensors have high repeatability and selectivity to the target ions. Real-time on-body assessment of sweat is also performed, and our results indicate that calcium concentration increases with decreasing pH. Finally, this platform can be used in noninvasive continuous analysis of ionized calcium and pH in body fluids for disease diagnosis such as primary hyperparathyroidism and kidney stones.

47 OTHER INSTRUMENTATION↗

A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide

There is an urgent need for disinfection and sterilization devices accessible to the public that can be fulfilled by innovative strategies for using cold atmospheric pressure plasmas. Here, we demonstrate a successful novel combination of a flexible printed circuit design of a dielectric barrier discharge (flex-DBD) with an environmentally safe chemical reagent for surface decontamination from bacterial contaminants. Flex-DBD operates in ambient air, atmospheric pressure, and room temperature without any additional gas flow at a power density not exceeding 0.5 W/cm 2 . The flex-DBD activation of a 3% hydrogen peroxide solution results in the reduction in the bacterial load of a surface contaminant of > 6log 10 in 90 s, about 3log 10 and 2log 10 better than hydrogen peroxide alone or the flex-DBD alone, respectively, for the same treatment time. We propose that the synergy between plasma and hydrogen peroxide is based on the combined action of plasma-generated OH · radicals in the hydrogen peroxide solution and the reactive nitrogen species supplied by the plasma effluent. A scavenger method verified a significant increase in OH · concentration due to plasma treatment. Novel in-situ FTIR absorption spectra show the presence of O 3 , NO 2 , N 2 O, and other nitrogen species. Ozone dissolving in the H 2 O 2 solution can effectively generate OH · through a peroxone process. The addition of the reactive nitrogen species increases the disinfection efficiency of the hydroxyl radicals and other oxygen species. Hence, plasma activation of a low concentration hydrogen peroxide solution, using a hand-held flexible DBD device results in a dramatic improvement in disinfection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The FUNPET—a New Hybrid Ion Funnel-Ion Carpet Atmospheric Pressure Interface for the Simultaneous Transmission of a Broad Mass Range

An atmospheric pressure interface transports ions from ambient pressure to the low-pressure environment of a mass spectrometer. A capillary coupled to an ion funnel is widely used. However, conventional ion funnels do little to negate the large amount of energy picked up by high-mass ions from the gas flow through the capillary. There has been little work done on the effects of gas flow on ion transmission, and the previous studies have all been limited to low-mass, low-charge ions. In this work, we account for the effects of gas flow, diffusion, and electric fields (static and oscillating) on ion trajectories and use simulations to design a new hybrid ion funnel-ion carpet (FUNPET) interface that transmits a broad mass range with a single set of instrument conditions. The design incorporates a virtual jet disruptor where pressure buildup and counter flow dissipate the supersonic jet that results from gas flow into the interface. This, and the small exit aperture that can be used with the FUNPET, reduces the gas flow into the next stage of differential pumping. The virtual jet disruptor thermalizes ions with a broad range of masses (1 kDa to 1 GDa), and once thermalized, they are transmitted into next region of the mass spectrometer with low excess kinetic energy. The FUNPET interface is easy to fabricate from flexible printed circuit board and a support frame made by 3D printing. The performance of the interface was evaluated using charge detection mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio frequency electrical resistance measurement under destructive pulsed magnetic fields

We developed a resistance measurement using radio frequency reflection to investigate the electrical transport characteristics under destructive pulsed magnetic fields above 100 T. A sample stage consisting of a homemade flexible printed circuit reduced the noise caused by the induced voltage from the pulsed magnetic fields, improving the accuracy of the measurements of the reflected waves. From the obtained reflectance data, the absolute value of the magnetoresistance was successfully determined by analyzing the phase with admittance charts. In conclusion, these developments enable more accurate and comprehensive measurements of electrical resistance in pulsed magnetic fields.

47 OTHER INSTRUMENTATION↗

Contoured PPM-EMAT Design for Ultrasonic Communication On Metallic Pipe Channels

Ultrasonic guided waves can be used as the carriers of information in ultrasonic communication for pipe or plate channels. Permanent Periodic Magnet (PPM) Electromagnetic Acoustic Transducer (EMAT) can potentially provide unique capabilities for a communication system as a non-contact transmitter and receiver, which can selectively generate different modes of shear-horizontal (SH) waves. The SH wave shows the potentials in achieving high bitrate without error in ultrasonic communication. However, when a steel pipe is used as the communication channel, especially one with a radius comparable to the size of the transducer, no guided wave signal can be excited or detected by existing PPM-EMAT's with flat coupling surface. In this paper, a 3D printed magnet holder is designed which can shape the magnet array. Also, the transmitter/receiver coils are made of flexible printed circuit which can fit over the curvature of the pipe channels. The contoured PPM-EMAT transmitter and receiver can conform to the surface of the steel pipe channel in order to generate and detect torsional waves. Experimental tests of signal transmission with PPM-EMAT on a 160cm-long stainless steel pipe determine the optimal frequency for communication to be 916KHz. Information transmission experimental results confirm the validity of contoured PPM-EMAT for communication with a bitrate of 5kbps.

Huang, Xin↗

High-temperature Superconducting Interconnects for Ultra-low Temperature, High-field Environments

Coplanar (with the ground) 20 cm long waveguides are manufactured from the YBCO-on-Kapton material. We investigate the effect of parasitic ground plane resonances on the performance of these waveguides. Here, it is concluded that dense rows stitching vias are essential for isolating the lines to a level below 60 dB at 6 GHz. We demonstrate a metalized via technology that is compatible with both the traditional Flexible Printed Circuit (FPC) process and the epitaxial YBCO material. Stitching via fence with the via period 10 mm is shown as effective in suppressing parasitic resonances at 77 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel $In-Situ$ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiations and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. We aimed to develop an in situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller. The system measures the flux change in a flexible printed circuit board coil attached to the undulator magnet array by periodically measuring the integral flux change during the opening and closing of the undulator gap. If the magnet block damage occurs, the signal from the coil will decrease proportionally to the damage. First tests performed on variable gap hybrid undulators for the Linac Coherent Light Source II (LCLS-II) at SLAC National Accelerator Laboratory showed that the system is capable of measuring flux changes with a relative precision of approximately 0.7 × 10 -4 over several days. Relative field changes smaller than 10 -4 were detected in short-term measurements. Here, the novel system that we propose here opens the possibility of detecting radiation damage in undulators during operation.

47 OTHER INSTRUMENTATION↗