Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluidic experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tuscaloosa Marine Shale Laboratory

The Tuscaloosa Marine Shale (TMS) in Louisiana and Mississippi is an Upper Cretaceous source rock formation sandwiched between the sands of the upper and lower Tuscaloosa sections. The TMS is believed to be the source rock for underlying prolific Tuscaloosa sand formation. The TMS has an unproven estimate of 7,000,000,000 bbls of recoverable oil while its current total average production is about 3,000 bbls of oil per day in 2017. In 2013 and 2014, more than 80 wells were drilled horizontally into the TMS that were fractured using multi-stage fracturing technology. The results from this have been mixed, but recent production for several wells show an appealing initial oil production rate of more than 1000 bbl/day. The preliminary core analysis by industry partners and a few literature studies shows that the TMS is one of the most clay-rich and sensitive shales to water. Due to these and other technical problems, there is high risk for the economic development of TMS compared to other shale plays. The experiences of major industrial players in the TMS show the necessity of open and collaborative efforts to better understand the critical gaps in the development of this challenging and potentially highly economic shale play to enable more cost-efficient and environmentally-sound recovery from this unconventional liquid-rich shale play. The overall objective of this project is to form a consortium of science and industry partners to address the following six major objectives using scientific and technical approaches: 1. To improve wellbore integrity by better understanding the sources of the wellbore instability issues, proposing innovative mud and cement design for the TMS. 2. To improve formation evaluation using laboratory techniques for the evaluation of mineralogical composition, organic content, and produced-water chemistry as well as well log and geophysical analysis. 3. To determine the role of geologic discontinuities on fracture growth and shale creep behavior using digital image correlation technique. 4. To investigate the application of stable CO 2 foam and super-hydrophobic proppants for improved reservoir stimulation. 5. To better understand the nature of water/hydrocarbon/CO 2 flow in clay and organic-rich formation and the role of water/fluid interaction on recovery. 6. To prepare better socio-economic environment for TMS development by community engagement. Subsequently, the TMS virtual laboratory conducted testing and analysis of various properties of rock and formation fluids from the TMS, including but not limited to the following: Analyzing reports and logs to better understand the source of wellbore instability in TMS wells; Experiments to design a customized cement based on TMS requirements; Experiments to obtain the mineralogical and geochemical composition of TMS samples; Seismic analysis of TMS geophysical data to better predict total organic carbon (TOC) content and brittleness in TMS; Well log analysis to better estimate the TOC and geo-mechanical properties of TMS; Experiments on formation water to understand the chemistry of produced water; Experiments to determine the role of lamination and natural fractures on fracture propagation or rock deformation using digital image correlation technique in in-direct tensile tests, semi-circular bend test and creep tests Experiments to determine the stability and rheological properties of nanoparticle-stabilized CO 2 foam in TMS rock samples; Experiments to determine fluid dynamics in un-propped TMS fractures and the role of nano-coating of proppants on fluid dynamics in fractures with proppants; Micro-fluidics experiments to enhance the understanding of fluid dynamics in tight liquidrich pores with high clay content; Socio-economic studies to better engage communities in TMS development.

58 GEOSCIENCES↗

MEMS Micro-Valve for Space Applications

We report on the development of a Micro-ElectroMechanical Systems (MEMS) valve that is designed to meet the rigorous performance requirements for a variety of space applications, such as micropropulsion, in-situ chemical analysis of other planets, or micro-fluidics experiments in micro-gravity. These systems often require very small yet reliable silicon valves with extremely low leak rates and long shelf lives. Also, they must survive the perils of space travel, which include unstoppable radiation, monumental shock and vibration forces, as well as extreme variations in temperature. Currently, no commercial MEMS valve meets these requirements. We at JPL are developing a piezoelectric MEMS valve that attempts to address the unique problem of space. We begin with proven configurations that may seem familiar. However, we have implemented some major design innovations that should produce a superior valve. The JPL micro-valve is expected to have an extremely low leak rate, limited susceptibility to particulates, vibration or radiation, as well as a wide operational temperature range.

Chakraborty, I.↗

MEMS Micro Valve for Space Applications

We report on the development of a Micro-Electro-Mechanical Systems (MEMS) valve that is designed to meet the rigorous performance requirements for a variety of space applications, such as micropropulsion, in-situ chemical analysis of the planet, or micro-fluidics experiments in micro-gravity.

MEMS↗

Experimental and analytical investigation of a fluidic power generator

A combined experimental and analytical investigation was performed to understand the various fluid processes associated with the conversion of flow energy into electric power in a fluidic generator. Experiments were performed under flight-simulated laboratory conditions and results were compared with those obtained in the free-flight conditions. It is concluded that the mean mass flow critically controlled the output of the fluidic generator. Cross-correlation of the outputs of transducer data indicate the presence of a standing wave in the tube; the mechanism of oscillation is an acoustic resonance tube phenomenon. A linearized model was constructed coupling the flow behavior of the jet, the jet-layer, the tube, the cavity, and the holes of the fluidic generator. The analytical results also show that the mode of the fluidic power generator is an acoustical resonance phenomenon with the frequency of operation given by f approx = a/4L, where f is the frequency of jet swallowing, a is the average speed of sound in the tube, and L is the length of the tube. Analytical results further indicated that oscillations in the fluidic generator are always damped and consequently there is a forcing of the system in operation.

Sarohia, V.↗

Investigating Soil Organic Matter Complexation using Spectral Induced Polarization

Spectral induced polarization (SIP) laboratory experiments were conducted to determine the sensitivity of this method to the formation of soil organic matter (SOM) complexes, with a long-term goal of field-scale monitoring. There are few SIP experiments that have explored this topic, yet understanding the dynamic behavior and interactions of SOM at the field scale could provide insight into soil fertility and health which influences crop yields, microorganisms that degrade organic pollutants, and carbon stabilization. We present the results of three experiments where the iron oxide, ferrihydrite (Fhy), was used to coat different media, and then the OM compound pentaglycine (PG) was pulse injected to form SOM complexes. SIP data was collected during these injections to capture any surface complexation changes. These experiments were performed in 1) a fluidic cell containing a micromodel, 2) a column containing Fhy coated ceramic beads and 3) a column containing Fhy coated Accusand®. Our results show a higher frequency response (defined here as > 1 Hz) in all three experiments, with the largest amplitude response after the first PG injection (Figure S.1). The repeatability of this response is encouraging and supporting data collected on the Accusand® experiment provides preliminary insight into the mechanisms controlling the SIP signatures. Sampling of fluid conductivity $σ_w$ and pH may indicate deprotonation of SOM occurring or rapid adsorption and release of protons from the Fhy sites. However additional experiments are needed to identify and confirm the primary and secondary reactions impacting the SIP response. We are looking towards other opportunities to continue this work, particularly to repeat experiments while collecting supporting datasets.

58 GEOSCIENCES↗

The flip-flop nozzle extended to supersonic flows

An experiment studying a fluidically oscillated rectangular jet flow was conducted. The Mach number was varied over a range from low subsonic to supersonic. Unsteady velocity and pressure measurements were made using hot wires and piezoresistive pressure transducers. In addition smoke flow visualization using high speed photography was used to document the oscillation of the jet. For the subsonic flip-flop jet it was found that the apparent time-mean widening of the jet was not accompanied by an increase in mass flux. It was found that it is possible to extend the operation of these devices to supersonic flows. Most of the measurements were made for a fixed nozzle geometry for which the oscillations ceased at a fully expanded Mach number of 1.58. By varying the nozzle geometry this limitation was overcome and operation was extended to Mach 1.8. The streamwise velocity perturbation levels produced by this device were much higher than the perturbation levels that could be produced using conventional excitation sources such as acoustic drivers. In view of this ability to produce high amplitudes, the potential for using small scale fluidically oscillated jet as an unsteady excitation source for the control of shear flows in full scale practical applications seems promising.

Raman, Ganesh↗

The flip flop nozzle extended to supersonic flows

An experiment studying a fluidically oscillated rectangular jet flow was conducted. The Mach number was varied over a range from low subsonic to supersonic. Unsteady velocity and pressure measurements were made using hot wires and piezoresistive pressure transducers. In addition smoke flow visualization using high speed photography was used to document the oscillation of the jet. For the subsonic flip-flop jet it was found that the apparent time-mean widening of the jet was not accompanied by an increase in mass flux. It was found that it is possible to extend the operation of these devices to supersonic flows. Most of the measurements were made for a fixed nozzle geometry for which the oscillations ceased at a fully expanded Mach number of 1.58. By varying the nozzle geometry this limitation was overcome and operation was extended to Mach 1.8. The streamwise velocity perturbation levels produced by this device were much higher than the perturbation levels that could be produced using conventional excitation sources such as acoustic drivers. In view of this ability to produce high amplitudes, the potential for using small scale fluidically oscillated jet as an unsteady excitation source for the control of shear flows in full scale practical applications seems promising.

Raman, Ganesh↗

Omni-gravity Hydroponics for Space Exploration

As part of the NASA Plant Water Management technology demonstration experiments, a capillary fluidics hydroponic system that can function in a variety of gravity environments has been developed and tested for crop production in space. A passive liquid delivery method is employed that drastically reduces the number of contaminable moving parts providing a high reliability solution requiring minimal resources for operation. The terrestrial, lunar, and Martian environments are managed in a ‘gravity-dominated mode,’ while the low-gravity transit and orbit environments are managed in a ‘capillary fluidics mode,’ where the role of gravity is replaced by the equally passive effects of surface tension, conduit shape, and wettability. The unique considerations for priming, germination, aeration, nutrient supply, root accommodation, layout, crew interaction, etc. are highlighted. Design guides for system function are provided along with high Technology Readiness Level demonstrations of the system during terrestrial and drop tower tests. Long duration tests are planned on short schedule aboard the International Space Station in 2019.

gravity↗

Beyond BioSentinel: Iterative Development of Automated Microfluidics

NASA Ames has flown a series of Bio-CubeSats that performed biology experiments supported by automated fluidic systems. Since Genesat-1 in 2006, these payloads have increased in complexity and functionality, building upon previous successes, and applying lessons learned. BioSentinel was the most recent of this series, launched into heliocentric orbit onboard Artemis-1 in 2022. This presentation will discuss how the fluidic technology developed for these Bio-CubeSat missions, including the multi-layer polycarbonate manifolds at the heart of the BioSentinel BioSensor, have spurred the development of several additional projects. Most directly is the modified BioSensor that will be a part of LEIA, which will perform its Lunar biology experiment onboard a Commercial Lunar Payload Services lander. Several search-for-life manifolds have been designed to prepare samples from icy moons for downstream analyses. Two early career Polaris projects are developing fluidics to perform genetic sequencing on samples from multigenerational cell culture and to extract and quantify target miRNAs to support astronaut radiation health assessment. Improving the readiness of these systems has been accelerated by adopting the established flight heritage and microgravity-compatibility of the Bio-CubeSat fluidic hardware and designs, while focusing development efforts on the integration of novel functionalities and components.

microfluidics↗

Fluidic Actuation for Aeropropulsive Acoustic Improvements

Experiments were performed in NASAs SW-2 cascade facility to compare three trailing edge actuation concepts to a 3D airfoil section with no trailing edge treatment. At a Reynolds number of 105, trailing edge pulsed ejection using fluidic oscillator devices was shown to fill the momentum deficit in the wake more uniformly than other actuators tested, with expected benefits for tonal noise in engine fans. Furthermore, pulsed ejection was found to alter the acoustic signature of the wake to reduce broadband noise. In some locations in the wake, spectral components of velocity were found to be reduced by 2 to 5 dB across nearly all frequencies. Trailing edge pulsed ejection is established as a feasible concept to reduce both tonal and broadband noise emissions from aircraft engines.

Stone, Mark↗

PowerCell aboard the EuCROPIS satellite - Results from the first synthetic biology experiment in space

Synthetic biology is the design and construction of new biological parts and systems not found in nature, a technology that we believe will be a game-changing technology for space exploration. The PowerCell concept is an ecology based on photosynthetic microbes taking advantage of in situ materials and energy to generate, on-demand, useful products (food, fuel, cloths, drugs, etc.) that satisfy specific needs of long-term human presence away from Earth. This first PowerCell experiment is testing this concept as well as several key mechanisms of engineering biology in a 48-well plate microfluidics system. NASA's PowerCell experiment was loaded in the fluidics system at NASA Ames in May 2016, and subsequently integrated on the DLR's compact satellite Eu:CROPIS (Euglena Combined Regenerative Organic food Production In Space), as a secondary payload. Launched into Earth’s orbit from the Vandenberg Air Force Base, California, USA, in December 3, 2019, the Eu:CROPIS platform has provided an artificial gravity through rotational acceleration, simulating gravity ranges compatible to those found on Mars and on the Moon, as well as microgravity in the absence of acceleration. Each set of biological experiments performed at Earth's orbit was compared to ground controls. Over 400 days' worth of mission data showed that all hardware and software worked as planned, and microbial growth was observed in all four gravity regimes, including growth on cyanobacterial cell extract in three out of four gravity regimes. The genetic transformation experiment was successful in microgravity and provided valuable long-term reagent stability data, including antibiotic efficacy. The demonstrated ability of hardy bacterial spores to recover from a long-term stasis period will be fundamental for deep human space missions. Lessons learned from hardware design to experimental operations are leading to improved designs and capabilities for future missions.

Ivan Glaucio Paulino Lima↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Abstract Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

Song, Jiaqi↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Fluidic Chevrons on Supersonic Jet Noise

The impact of fluidic chevrons on broadband shock noise and mixing noise for single stream and coannular jets was investigated. Air was injected into the core flow of a bypass ratio 5 nozzle system using a core fluidic chevron nozzle. For the single stream experiments, the fan stream was operated at the wind tunnel conditions and the core stream was operated at supersonic speeds. For the dual stream experiments, the fan stream was operated at supersonic speeds and the core stream was varied between subsonic and supersonic conditions. For the single stream jet at nozzle pressure ratio (NPR) below 2.0, increasing the injection pressure of the fluidic chevron increased high frequency noise at observation angles upstream of the nozzle exit and decreased mixing noise near the peak jet noise angle. When the NPR increased to a point where broadband shock noise dominated the acoustic spectra at upstream observation angles, the fluidic chevrons significantly decreased this noise. For dual stream jets, the fluidic chevrons reduced broadband shock noise levels when the fan NPR was below 2.3, but had little or no impact on shock noise with further increases in fan pressure. For all fan stream conditions investigated, the fluidic chevron became more effective at reducing mixing noise near the peak jet noise angle as the core pressure increased.

Henderson, Brenda↗

BioSentinel ISS Control Experiment Final Investigation Summary Form

Each payload has 18 fluidic cards and each fluidic card has 16 microfluidic wells, for a total of 288 wells. Card activation occurs at different time points throughout the 6-month mission and following ground commands. At each timepoint, two fluidic cards are filled with growth medium containing nutrients and a metabolic indicator dye. In addition to card filling, the temperature of the cards increases from ~4°C (stasis mode) to 23°C to allow for cell growth. The metabolic dye changes color from blue to pink, then pink to clearin the presence of metabolically active yeast cells. The colorimetric changes and cell growth are monitored using a 3-light-emitting diode(LED)optical detection system. The optical data determines how fast the cells are able to recover after accumulating radiation damage over time.After ground command initiation, all the fluidics, thermal and optical detection steps in BioSentinel are fully automated.The biosensor response data is compared to physical dosimetry data collected onboard the same payload. This dosimeter or linear energy transfer (LET)spectrometer is based on TimePix chip technology. This chip measures the total ionizing radiation dose in addition to calculating the LET of each particle that traverses its sensor, thus allowing researchers to characterize the radiation environment around the payload.The biological response (and physical dosimetry) on ISS over time is compared to the deep space mission and to data obtained on the ground.This analysis provides insight on the biological effects of the space radiation exposure in preparation for future long-duration missions to space and inhabitation beyond low-Earth orbit (LEO).

BioSentinel↗

Structural Requirements and Scaling Analysis of a Fluidic Mirror Space Telescope Support Structure

The NASA FLUTE project proposes large-scale (50m) fluidic telescopes for astronomy applications. To continue to explore the universe, astronomers require larger and larger telescope apertures. The highest priority astrophysics targets such as exoplanets and early galaxies are extremely faint, motivating larger telescope apertures. However, mission costs depend on aperture diameter, and scaling apertures beyond 10-m apertures faces economic and technological viability challenges. An unsegmented primary mirror made in space via fluidic microgravity shaping would provide a scalable and cost-effective method to scale apertures to 50-m scale while achieving sub-nanometer (root mean square) surface quality. Such microgravity fluidic shaping has been demonstrated in laboratory neutral buoyance environments, parabolic microgravity experiments, as well aboard the International Space Station. One of the main components of a fluidic observatory is the mirror frame. The frame must provide a stable bounding circular ring which the edges of the fluid mirror surface can wet. The frame can optionally provide a ‘floor’ surface on the interior of the ring to provide additional fluid support and reduce required fluid volume. In this work, we evaluate several classes of structural frame architectures potentially suitable for a fluidic telescope support structure. We start by estimating stability requirements, orbital, station keeping, and slew loads based on a notional CONOPS. The scaling of overall fluid mass required for each architecture is evaluated. Preliminary results elucidate the importance of a support floor for overall mission viability above 10-m diameter. We then investigate the scaling of a tetrahedral truss frame support structure. We show that segmented solid shell support surfaces can provide sufficient stability at modest mass fractions. We estimate that the total fluid and frame mass for a 50-m telescope could be on the order of 15,000 kg. Finally, implementation considerations are discussed, including deployment/assembly methodologies. The results of this study establish feasibility of a large-scale fluidic telescope and will guide further architecture development and detailed structural design.

Christine Gregg↗

The BioSensor Instrument Beyond LEIA: a Versatile Platform for Lunar Biology

Introduction: The BioSensor is a deep-space-compatible automated microfluidic culturing instrument. While originally designed to measure the effects of deep space radiation on yeast growth for the BioSentinel mission, it has the potential to host a diverse range of life science experiments with single- and/or multi-celled organisms and can be adapted to interface with a diverse range of platforms in both crewed and uncrewed settings. It is therefore a leading candidate for hosting life sciences experimentation associated with a lunar surface habitat. BioSensor design: The function of the BioSensor is to monitor the growth and metabolic activity of samples in batch fluidic culture, without the need for crew involvement. The current configuration houses organisms in 16 wells within 16 microfluidic cards, accommodating a total of 256 samples, replicates, and controls. Each well has an optical system including three LEDs and a photodiode detector to measure absorbance at three wavelengths, enabling measurement of optical density, color change in dyes such as alamarBlue, and bioproduction of pigmented compounds. Organisms are loaded into fluidic wells and air-dried for storage during integration, launch, and transit, then activated by the introduction of culture medium from storage bags via manifolds that fill one card at a time. Temperature is controlled by individual card heaters, and timing of all activities (fluidics fills, optical measurements, temperatures) is directed by an experiment script. The self-contained BioSensor payload is roughly 4U in volume; with electrical/mechanical/thermal interface, e.g. for operation on ISS or a lunar lander, as well as a linear energy-transfer (LET) charged-particle radiation spectrometer, the entire system is closer to 6U. BioSentinel and LEIA: Flown on the ISS and in a deep-space free flyer for BioSentinel, the BioSensor has been modified for use in the LEIA mission, including improvements to reduce the sensitivity to lengthy launch delays. LEIA will monitor yeast growth in the radiation and reduced-gravity environment of the lunar surface no earlier than 2026, on a CLPS lander [4]. Changes include accommodating additional culture media and an additional LED color for a new biological assay (bioproduction of carotenoids-- dietary antioxidants), as well as modifications to the housing to allow late-load biology changeout and improved isolation between fluidics and electronics. Future prospects: Future work with the BioSensor, beyond LEIA, will include expanding the range and diversity of organisms and assays accommodated. Preliminary work has demonstrated the growth of Arabidopsis seedlings in BioSensor fluidic cards, including optical measurements of growth rate over time. Minor modifications could allow measurement of phenotypes related to photosynthetic capacity in both plants and cyanobacteria. The experimental capabilities of the BioSensor could be dramatically increased by introducing the capability for fluorescence measurements, and/or the design of novel biological assays using luminescence. The BioSensor can also be adapted for new platforms and experiment settings; in addition to free-flyer, ISS, and CLPS lander, a preliminary design concept has been developed for crewed deployment directly to the lunar surface. The instrument could be accommodated inside a lunar habitat, where its automated operation would make it an excellent candidate for experiments from fundamental investigations into the response of organisms to lunar surface conditions to applied-science purposes such as screening engineered strains of various organisms for bioproduction capability.

J A Lee↗

The Lunar Explorer Instrument for Space Biology Applications (LEIA) Pre-Flight Tests: Mechanical Considerations​

The BioSensor payload on the upcoming LEIA platform aboard the CLPS (CP-22) lander will carry yeast to the Moon's south pole to study the effects of lunar radiation and gravity. From Earth, BioSensor will transport desiccated yeast within 16 fluidic cards, each containing 16 fluidic wells of 100 microliters volume. At the start of the experiment, these microbes will be autonomously rehydrated on the Moon, and optical absorbance measurements at three wavelengths will be performed across all 256 wells. Absorbance measurements in fluidic wells are susceptible to noise and artifacts due to bubble formation during well rehydration and microbial growth. BioSensor, as a biofluidics system, faces significant data anomalies caused by payload vibrations, particularly from the operation of the co-located PROSPECT’s ProSEED drill, to assess lunar resources by penetrating the subsurface. To evaluate the impact of drill vibrations, fully assembled and filled fluidic cards were subjected to sine sweep signals in the x, y, z planes, ranging from 5 - 2560 Hz at g-loads of 0.25 and 0.5, with on-board accelerometer for localized vibration measurement. Wells with various fill conditions, including partial fills with different bubble sizes and completely filled wells, were tested. Results indicated that small bubbles adhered to well walls at high frequencies but were dislodged at low frequencies, causing data anomalies. Medium and large bubbles exhibited higher interference with optical data due to lower surface tension and variable bubble surface flexion. Overall, it was found that irrespective of the fill type, low-frequency vibrations were most detrimental to optical readings. Understanding the drill schedule and correlating it with BioSensor timestamps will help identify periods when BioSensor data is unreliable, a crucial step for accurately interpreting the microbial response data and ensuring the validity of the BioSensor's scientific measurements on the lunar surface.

Chinmayee Govinda Raj↗