Search NASA⌕ Search

SEARCH · Search NASA

Results for “fly scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.

36 MATERIALS SCIENCE↗

CodEx: A Modular Framework for Joint Temporal De-Blurring and Tomographic Reconstruction

In many computed tomography (CT) imaging applications, it is important to rapidly collect data from an object that is moving or changing with time. Tomographic acquisition is generally assumed to be step-and-shoot, where the object is rotated to each desired angle, and a view is taken. However, step-and-shoot acquisition is slow and can waste photons, so in practice fly-scanning is done where the object is continuously rotated while collecting data. However, this can result in motion-blurred views and consequently reconstructions with severe motion artifacts. In this paper, we introduce CodEx, a modular framework for joint de-blurring and tomographic reconstruction that can effectively invert the motion blur introduced in sparse view fly-scanning. The method is a synergistic combination of a novel acquisition method with a novel non-convex Bayesian reconstruction algorithm. CodEx works by encoding the acquisition with a known binary code that the reconstruction algorithm then inverts. Using a well chosen binary code to encode the measurements can improve the accuracy of the inversion process. The CodEx reconstruction method uses the alternating direction method of multipliers (ADMM) to split the inverse problem into iterative deblurring and reconstruction sub-problems, making reconstruction practical to implement. Here we present reconstruction results on both simulated and binned experimental data to demonstrate the effectiveness of our method.

42 ENGINEERING↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging

X-ray ptychography, a powerful scanning lensless imaging technique, has become attractive for nondestructively imaging internal structures at nanoscale. Stage positioning overhead in conventional step-scan ptychography is one of the limiting factors on the imaging throughput. In this work, we demonstrate the use of advanced fly scan ptychography to achieve high-resolution ptychograms of modern integrated circuits on a large field-of-view at millimeter scale. By completely removing stage overheads between scan points, the imaging time for millimeter-size sample can be significantly reduced. Furthermore, we implement the orthogonal probe relaxation technique to overcome the variation of illumination across the large scan area as well as local vibrations. The capability of x-ray ptychography shown here is broadly applicable for various studies, which requires both high spatial resolution and large scan area.

47 OTHER INSTRUMENTATION↗

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

Complete Strain Mapping of Nanosheets of Tantalum Disulfide

Quasi-two-dimensional (quasi-2D) materials hold promise for future electronics because of their unique band structuresthat result in electronic and mechanical properties sensitive to crystal strains in all three dimensions. Quantifying crystal strain is a prerequisite to correlating it with the performance of the device, and calls for high resolution but spatially resolved rapid characterization methods. Here we show that using fly-scan nano X-ray diffraction we can accomplish a tensile strain sensitivity below 0.001% with a spatial resolution of better than 80 nm over a spatial extent of 100 µm on quasi 2D flakes of 1T-TaS2. Coherent diffraction patterns were collected from a ~100 nm thick sheet of 1T-TaS2 by scanning 12keV focused X-ray beam across and rotating the sample. We demonstrate that the strain distribution around micron and sub-micron sized ‘bubbles’ that are present in the sample may be reconstructed from these images. The experiments use state of the art synchrotron instrumentation, and will allow rapid and non-intrusive strain mapping of thin film samples and electronic devices based on quasi 2D materials.

nano X-ray diffraction↗

Embedded EPICS server for PowerPMAC motion controllers

An embedded server layer of Experimental Physics and Industrial Control System (EPICS) for PowerPMAC motion controllers has been developed and deployed at two undulator beamlines of the National Institute of General Medical Sciences and the National Cancer Institute (GM/CA) Structural Biology Facility at the Advanced Photon Source (APS). This compact, open source solution makes the power and versatility of PowerPMAC motion controls directly accessible to distributed EPICS clients. At GM/CA the system controls about 200 servo and stepper motors — both encoded and unencoded — and multiple digital and analog I/O accessories. The server stack comprises two sublayers: a lower-level driver and database that communicates directly with PowerPMAC, and a facility-specific soft sublayer built on top. The paper describes installing EPICS on PowerPMAC, the implementation of both layers and client examples, including on-the-fly scanning.

EPICS↗

Fast automated energy changes at synchrotron radiation beamlines equipped with transfocator or focusing mirrors

Algorithms and procedures to fully automate retuning of synchrotron radiation beamlines over wide energy ranges are discussed. The discussion is based on the implementation at the National Institute of General Medical Sciences and the National Cancer Institute Structural Biology Facility at the Advanced Photon Source. When a user selects a new beamline energy, software synchronously controls the beamline monochromator and undulator to maintain the X-ray beam flux after the monochromator, preserves beam attenuation by determining a new set of attenuator foils, changes, as needed, mirror reflecting stripes and the undulator harmonic, preserves beam focal distance of compound refractive lens focusing by changing the In/Out combination of lenses in the transfocator, and, finally, restores beam position at the sample by on-the-fly scanning of either the Kirkpatrick–Baez mirror angles or the transfocator up/down and inboard/outboard positions. The sample is protected from radiation damage by automatically moving it out of the beam during the energy change and optimization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ultra_fast_tomo

It is a pre-trained model for processing blurred and noisy tomographic reconstruction taken from a fast fly-scan.

Ge, Mingyuan↗

Adorym: a multi-platform generic X-ray image reconstruction framework based on automatic differentiation

We describe and demonstrate an optimization-based X-ray image reconstruction framework called Adorym. Our framework provides a generic forward model, allowing one code framework to be used for a wide range of imaging methods ranging from near-field holography to fly-scan ptychographic tomography. By using automatic differentiation for optimization, Adorym has the flexibility to refine experimental parameters including probe positions, multiple hologram alignment, and object tilts. It is written with strong support for parallel processing, allowing large datasets to be processed on high-performance computing systems. We demonstrate its use on several experimental datasets to show improved image quality through parameter refinement.

36 MATERIALS SCIENCE↗

Mechanical Design Progress of the In Situ Nanoprobe Instrument for APS-U

The In Situ Nanoprobe (ISN, 19-ID) beamline will be a new best-in-class long beamline to be constructed as part of the Advanced Photon Source Upgrade (APS-U) project [1, 2]. To achieve long working distance at high spatial resolution, the ISN instrument will be positioned 210 m downstream of the x-ray source, in a dedicated satellite building, currently under construction [3]. The ISN instrument will use a nano-focusing Kirkpatrick-Baez (K-B) mirror system, which will focus hard x-rays to a focal spot as small as 20 nm, with a large working distance of 61 mm. The large working distance provides space for various in situ sample cells for x-ray fluorescence tomography and ptychographic 3D imaging, allows the use of a separate, independent vacuum chambers for the optics and sample, and provides the flexibility to run experiments in vacuum or at ambient pressure. A consequence of the small spot size and large working distance are stringent requirements for high angular stability of the K-B mirrors (5 nrad V-mirror and 16 nrad H-mirror) and high relative stability be-tween focus spot and sample (4 nmRMS). Additional features include fly-scanning up to 2 kg mass, sample plus in situ cell, at 1 mm/s in vertical and/or horizontal directions over an area of 10 mm x 10 mm. Environmental capabili-ties will include heating and cooling, flow of fluids and applied fields, as required for electrochemistry and flow of gases at high temperature for catalysis. To achieve these capabilities and precise requirements we have used precision engineering fundamentals to guide the design process.

Kearney, Steven P.↗

Determine the coordination of Al and Si of Fe-rich fly ash: The challenge in NMR and how we probe its heterogeneity using X-ray spectromicroscopy

Scanning transmission X-ray microscopy (STXM) coupled with ptychographic imaging at Al and Si K-edge is a new probe to the microscale chemistry of heterogenous materials. Here, the combined techniques are applied to study local coordination environment of Fe-rich fly ash (FA). Ptychographic imaging at Al K- and Si K-edge highlights the fine Al- and Si-rich morphological features, respectively, at 6 nm pixel resolution. STXM visualizes the inter- and intra-particle variations in the silicate polymerization degree and two types of Al coordination environment in FA. The Si K-edge of SiO4 connected with four-fold coordinated Al is higher than SiO4 sharing oxygen with six-fold coordinated Al. The result is consistent with bulk nuclear magnetic resonance spectroscopy measurement of the Fe-rich sample which, however, is sensitive to paramagnetic Fe and time-consuming. Here, we demonstrate that the combined method has great potential in the studies of chemically heterogenous aluminosilicates.

01 COAL, LIGNITE, AND PEAT↗

Degradation mechanism of blended cement pastes in sulfate-bearing environments under applied electric fields: Sulfate attack vs. decalcification

Applied electric fields, the reason behind stray currents, accelerate the ingress of sulfate into cementitious materials. To identify mitigation approaches, this study investigates the effects of slag and fly ash on sodium sulfate attacks of cement pastes under a constant electric current. The mineralogical alterations induced by the attacks were analyzed using X-ray diffractometry, thermogravimetric analysis, scanning electron microscopy, and thermodynamic modeling. The dissolution of aluminates in the slag and fly ash induced a monosulfate-rich area (>~20 mm from the cathode surface) to form next to the ettringite-rich area on the sample surface (<~20 mm). This effect reduced the availability of SO 4 2– in the pore solution, thereby hindering the penetration of sulfate. Meanwhile, the consumption of portlandite by the pozzolanic reaction lowered the decalcification resistance of the materials. This produced a wide area that endured the decomposition of portlandite and carbonate-AFm. Altogether, blending 30% fly ash did not improve the resistance of the material to either sulfate attacks or decalcification; blending 50% slag can effectively mitigate sulfate ingress, though decalcification may become a governing mechanism in the degradation process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the Critical Element Chemistry of Coal-Combustion Fly Ash: Examination of Zircon and Associated Minerals from a Beneficiated Kentucky Fly Ash

Along with the principal rare earth (REE) minerals such as monazite, xenotime, and bastnasite, Y-and REE-bearing zircon and associated minerals survive the combustion process and are found in coal-combustion fly ash. Beneficiated fly ash from a power plant burning an eastern-Kentucky-sourced coal blend was found to have zircon (ZrSiO4), baddeleyite (ZrO2), fergusonite (YNbO4), yttriaite (Y2O3), and xenotime (YPO4). Previous studies of the same fly had also identified monazite with a broad REE suite. Scanning electron microscopy–electron dispersive spectroscopy (EDS) and transmission electron microscopy (TEM)–EDS as well as other TEM-based techniques revealed a variety of zircon associations, including heavy-REE suites with Y, Nb, and Hf. Hafnium is a common accessory element in zircons and the Y and Nb may be present as fergusonite (YNbO4) intermixed with zircon.

Berti, Debora (ORCID:0000000311237794)↗

High-Resolution Transmission Electron Microscopy Study of a Powder River Basin Coal-Derived Fly Ash

Examination of a fly ash derived from the combustion of a low-S, subbituminous Powder River Basin coal by Scanning Electron Microscopy (SEM) and High-resolution Transmission Electron Microscopy (HRTEM), both supplemented by Energy-dispersive X-ray spectroscopy (EDS), showed that the fly ashes were dominated by amorphous phases, Ca-rich plagioclase feldspars, Mg-rich phases, complex Ca-Mg-Al-Si-Ti-Fe grains, and trace amounts of REE-rich particles. Many of the particles were rimmed by a Ca-S, possibly a sulfate. HRTEM-EDS examination of a REE-rich particle proved it to be a mix of light- and heavy-rare earth minerals mixed with amorphous phases.

58 GEOSCIENCES↗

Comprehensive Study of the Potential of Extracting and Processing Critical Minerals from Coal-Based Resources - Phase I

The Phase I report prepared for the Department of Energy addresses U.S. Executive Order 13817 titled A Federal Strategy to Ensure Secure and Reliable Supplies of Critical Minerals, issued on December 20, 2017, that lists 35 critical minerals that are vulnerable to supply disruption. A comprehensive review of each of the minerals was conducted to determine the criticality based primarily on extractability from coal-based resources. Several other factors were also considered such as gaps in supply and demand, use in current technology, and the existence of viable substitutes. It was determined that the critical minerals that show highest potential for extraction from coal-based resources are lithium, rare earth elements (REEs), cobalt, and manganese. All four of the critical minerals listed serve an important role in the technology industry, have few substitutes, and have a heavy import reliance. Most notably are lithium, which is widely used in the electric vehicle industry, and the REEs which can be found in virtually all electronic devices. The research of critical mineral extraction from coal-based resources was completed using a combination of literature review from public sources as well as cooperation from coal mines and power plants across the United States. Samples collected from six different geographical locations across the U.S. were subjected to sample preparation (i.e., pH measurement, moisture content, particle size analysis) and characterization studies using Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) and Scanning Electron Microscopy, Energy Dispersive X-Ray Spectroscopy (SEM-EDX) instruments. 27 samples of coal waste materials such as refuse, sludge, and fly ash were tested to characterize the rare earth element concentration by total rare earth elements (TREEs), heavy rare earth elements (HREEs), and light rare earth elements (LREEs). Of the 27 samples tested, 22 contained a TREE concentration higher than the threshold of 300 ppm, which is considered a viable feedstock material. 3 samples contained less than 300 ppm of TREEs; however, they were within 20 ppm of the threshold, and could potentially be considered viable sources in the future pending the advancement of more efficient extraction technologies. 2 of the 27 samples had significantly low TREE concentrations, which does not imply any potential for being a source for REEs. For the minerals identified as most critical in the literature review, a conceptual process flow diagram (PFD) was developed for their extraction from different coal-based feedstocks. The process targets selective recovery of one commodity (i.e., rare earths, lithium, cobalt, and manganese) via several hydrometallurgical separation methods. By identifying potentially extractable coal-based critical mineral resources, a study of the current and future market environments for each critical mineral, and a review of current processing methodologies for critical mineral extraction from coal-based resources, the foundation has been laid to further characterize and explore new resources and extraction techniques. As reliance on technologies in industries such as the production of electronic devices, batteries, and alloys containing critical minerals utilizing critical minerals continues to increase, a sound understanding of our nation’s dependence on and even the global criticality of certain critical minerals, will serve as a catalyst for innovation in virtually all fields of science.

01 COAL, LIGNITE, AND PEAT↗