At least 19 records

Harnessing Quantum Capacitance in 2D Material/Molecular Layer Junctions for Novel Electronic Device Functionality

Two-dimensional (2D) materials promise advances in electronic devices beyond Moore’s scaling law through extended functionality, such as non-monotonic dependence of device parameters on input parameters. However, the robustness and performance of effects like negative differential resistance (NDR) and anti-ambipolar behavior have been limited in scale and robustness by relying on atomic defects and complex heterojunctions. In this paper, we introduce a novel device concept that utilizes the quantum capacitance of junctions between 2D materials and molecular layers. We realized a variable capacitance 2D molecular junction (vc2Dmj) diode through the scalable integration of graphene and single layers of stearic acid. The vc2Dmj exhibits NDR with a substantial peak-to-valley ratio even at room temperature and an active negative resistance region. The origin of this unique behavior was identified through thermoelectric measurements and ab initio calculations to be a hybridization effect between graphene and the molecular layer. The enhancement of device parameters through morphology optimization highlights the potential of our approach toward new functionalities that advance the landscape of future electronics.

2D materials↗

Advanced Functional Materials ZnO@ZIF-8 Heterostructures for Neuromorphic Synaptic Devices

Metal-Organic Frameworks have shown great promise for memristive synaptic devices because of their adaptable electrical properties and inherent porosity, which help in efficient ion transport and storage of functional molecules. However, the limited conductivity and sensitivity to moisture associated with most MOF materials hinder their use in electronic applications. In this study, MOFs derived from metabolites have been synthesized, using ZnO as a self-sacrificial metallic source to grow Zeolitic Imidazolate Framework-8 (ZIF-8), forming ZnO@ZIF-8 heteronanostructures for neuromorphic applications. These hybrids ZnO@ZIF-8 act as promising candidates for advanced electronic applications. Through systematic investigations, including a comparison of ZnO@ZIF-8 bilayer devices with ZnO single-layer counterparts, a significant discovery emerged. The bilayer synaptic devices outperformed their single layer counterparts in electrical characteristics, as evidenced by Current-Voltage curve analysis and Long-Term Potentiation/Long Term Depression (LTP/LTD) measurements. Additionally, the ZnO layer thickness (10, 30, 50 nm) has been emphasized and the effects of annealing at 300°C in a vacuum were carefully studied for Neuromorphic Synaptic Devices. Remarkably, the 10 nm ZnO layer exhibited the lowest set voltage and a consistent On/Off ratio. This work marks a significant advancement in understanding bilayer synaptic devices, highlighting the crucial role of ZIF-8 in shaping the future of neuromorphic systems

Kolleboyina, Jayaramulu↗

3D Printing of Functional Hydrogel Devices for Screenings of Membrane Permeability and Selectivity

Developing a fundamental understanding of the effects of varying ligand chemistries on mass transport rates is key to designing membranes with solute-specific selectivity. While permeation cells offer a robust method to characterize membrane performance, they are limited to assessing a single membrane chemistry or salt solution per test. As a result, investigating the effects of varying ligand chemistries on membrane performance can be a tedious process, involving both the preparation of multiple samples and numerous, time-consuming permeation tests. This study uses digital light processing (DLP) 3D printing to fabricate a millifluidic flow-based permeation device made from a hydrogel active ester network that can be easily functionalized with ion-selective ligands. Without the need for bonding or assembly steps, ligands can be introduced and tested in the permeation device by simply injecting a small volume of a ligand solution. Various salt concentrations and molecular species can be cycled through a single device by switching the solution feeding into the salt reservoir, thereby reducing the number of samples needed for permeability and selectivity screenings. This research sets the groundwork for formulation development and postprocessing methods to 3D-print functional millifluidic devices capable of assessing solute selectivity in membranes and polymer adsorbents for aqueous separations. In this work, comparable salt permeability trends were observed with both 3D-printed devices and traditional assays. Devices were functionalized with an imidazole ligand to investigate salt permeability and selectivity of monovalent and divalent salts. Measurements showed increasing permeability for monovalent salts (NaCl) relative to divalent salts (MgCl 2 , CuCl 2 ) in functionalized membranes, with higher monovalent/divalent selectivity at increasing imidazole grafting densities. Here, the methods and findings described here represent a step toward developing higher-throughput methods with 3D-printed devices for screening the effects of ligand chemistry on mass transport rates in membrane materials.

36 MATERIALS SCIENCE↗

Autonomous Aerosol and Plasma Co‐Jet Printing of Metallic Devices at Ambient Temperature

Abstract Additive manufacturing of metallic materials holds the potential to revolutionize the fabrication of functional devices unattainable via traditional methods. Despite recent advancements, printing metallic materials typically requires thermal processing at elevated temperatures to form dense structures with desired properties, which presents a major challenge for direct printing and integration with temperature‐sensitive materials. Herein, a unique co‐jet printing (CJP) method is reported integrating an aerosol jet and a non‐thermal, atmospheric pressure plasma jet to enable concurrent aerosol deposition of metal nanoparticle inks and in situ sintering at ambient temperature. A machine learning algorithm is integrated with the CJP to perform real‐time defect detection and autonomous correction, enhancing the yield of printed films with high electrical conductivity from 44% to 94%. Concurrent printing and sintering eliminate the need for post‐printing processing, reducing the overall manufacturing time by multiple folds depending on product size. CJP enables direct printing of functional devices on a variety of temperature‐sensitive materials including biological materials. Direct printing of hydration sensors on living plant leaves is demonstrated for long‐duration monitoring of hydration level in the plant. The versatile CJP method opens tremendous opportunities to harmoniously integrate abiotic and biotic materials for emerging applications in wearable/implantable devices and biohybrid systems.

Du, Yipu [Department of Aerospace and Mechanical E↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

Knowledge gaps for neuromorphic ionic computing

BACKGROUND Neuromorphic computing, inspired by the human brain’s ability to process information efficiently, represents a transformative approach to computation. In this Review, we explore the emerging field of neuromorphic ionic computing, which leverages ionic conduction and coupling to mimic neural processes, and identify critical knowledge gaps that must be addressed to realize its full potential. A central theme of the discussion is energy efficiency, a challenge that is both a limitation and an opportunity for this technology. Although complementary metal-oxide semiconductor (CMOS)–based neuromorphic technologies have made strides in scaling to billions of neurons and are increasingly applied in artificial intelligence and numerical computing, they remain orders of magnitude behind the human brain in terms of connectivity and energy efficiency. Neuromorphic ionic computing promises to overcome these limitations by leveraging the distinct architectural and operational principles of the brain. Our brains achieve this energy efficiency by combining several key features: using the same network elements to store and process information; using an incredibly complex and massively interconnected three-dimensional (3D) network of locally active elements that enables sparsity, robustness in the presence of noise, adaptation, and life-long learning; computing at comparatively low voltage and frequency; and last, taking advantage of a plethora of ions and small molecules as information carriers. Here, we propose that ionic computing systems can take advantage of similar features to achieve substantial gains in energy efficiency. ADVANCES Since the first reports of neuromorphic ionic behavior in nanofluidic channels, we have witnessed an explosion of reports that used ionic devices to produce synaptomimetic behaviors. However, achieving the goals of ionic computing requires not only implementation of much more sophisticated device functionality but also overcoming fundamental barriers in materials science, device architecture, and system integration. Current ionic devices, even those incorporating state-of-the-art materials, still suffer from limited functionality and stability, which restrict their performance and increase energy demands. Developing new materials with enhanced ionic properties is essential to overcome these limitations. Similarly, the design of neuromorphic devices must evolve to leverage the particular advantages of ionic processes. Existing architectures often follow a single-information-carrier logic of conventional electronics or are constructed of mesoscale fluidics, failing to capitalize on the energy-efficient mechanisms inherent to ionic systems or implement the multiple-information-carrier paradigm. Current neuromorphic chips focus on large-scale networks of analog memory elements based on mechanisms such as charge trap (flash), filamentary, phase change, or spin, which are built on top of a network of artificial CMOS neurons. Although such prototype networks have achieved impressive performance, it is difficult to envision how they can implement the key features such as massive connectivity, sophisticated plasticity, adaptability, sparsity, and “multichromatic” computing. Although small-scale devices have demonstrated promising results, integrating them, maintaining energy efficiency, and implementing temperature control as systems grow in complexity and size to computationally relevant scale remain major hurdles. Furthermore, interfacing neuromorphic ionic devices with existing computing technologies presents technical and conceptual challenges that will require innovative approaches that combine insights from neuroscience, materials science, and engineering. OUTLOOK Despite these challenges, the potential impact of neuromorphic ionic computing is profound with potential applications ranging from artificial intelligence to robotics and beyond. We also argue that neuromorphic ionic computing systems should not, at least in the beginning, compete with CMOS technologies but rather should focus on applications that require extreme energy efficiency with chemical and/or biological compatibility, such as biomedical applications (for example, brain-computer interfaces), environmental monitoring, and agricultural and food applications. Ultimately, this Review highlights the crucial role of interdisciplinary collaboration in advancing the field. Neuromorphic ionic computing is not merely a technological innovation; it represents a substantial step toward sustainable computation, aligning with the growing demand for energy-conscious solutions in a world that is increasingly reliant on data and computation.

Neuromorphic↗

Thermal Excitation System for Shearography (TESS)

One of the most convenient and effective methods of stressing a part or structure for shearographic evaluation is thermal excitation. This technique involves heating the part, often convectively with a heat gun, and then monitoring with a shearography device the deformation during cooling. For a composite specimen, unbonds, delaminations, inclusions, or matrix cracking will deform during cooling differently than other more structurally sound regions and thus will appear as anomalies in the deformation field. However, one of the difficulties that cause this inspection to be dependent on the operator experience is the conventional heating process. Fanning the part with a heat gun by hand introduces a wide range of variability from person to person and from one inspection to the next. The goal of this research effort was to conduct research in the methods of thermal excitation for shearography inspection. A computerized heating system was developed for inspection of 0.61 m (24 in.) square panels. The Thermal Excitation System for Shearography (TESS) provides radiant heating with continuous digital measurement of the surface temperature profile to ensure repeatability. The TESS device functions as an accessory to any electronic shearography device.

Lansing, Matthew D.↗

Electrical Switching of Perovskite Thin-Film Resistors

Electronic devices that exploit electrical switching of physical properties of thin films of perovskite materials (especially colossal magnetoresistive materials) have been invented. Unlike some related prior devices, these devices function at room temperature and do not depend on externally applied magnetic fields. Devices of this type can be designed to function as sensors (exhibiting varying electrical resistance in response to varying temperature, magnetic field, electric field, and/or mechanical pressure) and as elements of electronic memories. The underlying principle is that the application of one or more short electrical pulse(s) can induce a reversible, irreversible, or partly reversible change in the electrical, thermal, mechanical, and magnetic properties of a thin perovskite film. The energy in the pulse must be large enough to induce the desired change but not so large as to destroy the film. Depending on the requirements of a specific application, the pulse(s) can have any of a large variety of waveforms (e.g., square, triangular, or sine) and be of positive, negative, or alternating polarity. In some applications, it could be necessary to use multiple pulses to induce successive incremental physical changes. In one class of applications, electrical pulses of suitable shapes, sizes, and polarities are applied to vary the detection sensitivities of sensors. Another class of applications arises in electronic circuits in which certain resistance values are required to be variable: Incorporating the affected resistors into devices of the present type makes it possible to control their resistances electrically over wide ranges, and the lifetimes of electrically variable resistors exceed those of conventional mechanically variable resistors. Another and potentially the most important class of applications is that of resistance-based nonvolatile-memory devices, such as a resistance random access memory (RRAM) described in the immediately following article, Electrically Variable Resistive Memory Devices (MFS-32511-1).

Liu, Shangqing↗

Photoabsorption and Stability in Triple-Cation Perovskites Influenced by Interfacial Engineering of the Collector

Charge carrier dynamics in three-dimensional (3D) perovskites is critical to understand for enhancing device performance since the photoabsorption mechanism in perovskites influences key functional devices such as photodetectors and solar cells. Temperature-dependent optoelectronic transport measurements were conducted on our triple cation formulation for the first time from 4 K to 300 K to investigate the role of an interfacial Ti underlayer, beneath the conventional Au collector electrode. The photocurrent was 10X larger with the use of a Ti interfacial layer compared to only Au, where device measurements were made using a broadband white light source at room temperature. As temperature increased from 4 K, the photocurrent increased in both cases, consistent with the semiconducting nature of the triple-cation absorber. Besides computing the responsivity as a function of power and temperature, time-domain measurements with ON/OFF pulses of incident white light, showed the switching time constants to be in the tens to few hundred milliseconds range, and largely temperature-invariant for the two contacts examined. Finally, we constructed solar cells with the same triple cation absorber, in an n-i-p architecture with a Spiro-OMeTAD hole transport layer, but the collector was composed of both types of contacts. Exposing our devices to moisture-rich conditions of up to 70% relative humidity showed the Au/Ti contacted devices to be more robust. Here, our experimental results demonstrate that the addition of a Ti interlayer improves collector efficiency through the photoabsorption process while also potentially stabilizing the solar cells, compared to the bare Au, in moisture-rich environments

optoelectronics↗

Electronics for Extreme Environments

Most of the NASA missions involve extreme environments comprising radiation and low or high temperatures. Current practice of providing friendly ambient operating environment to electronics costs considerable power and mass (for shielding). Immediate missions such as the Europa orbiter and lander and Mars landers require the electronics to perform reliably in extreme conditions during the most critical part of the mission. Some other missions planned in the future also involve substantial surface activity in terms of measurements, sample collection, penetration through ice and crust and the analysis of samples. Thus it is extremely critical to develop electronics that could reliably operate under extreme space environments. Silicon On Insulator (SOI) technology is an extremely attractive candidate for NASA's future low power and high speed electronic systems because it offers increased transconductance, decreased sub-threshold slope, reduced short channel effects, elimination of kink effect, enhanced low field mobility, and immunity from radiation induced latch-up. A common belief that semiconductor devices function better at low temperatures is generally true for bulk devices but it does not hold true for deep sub-micron SOI CMOS devices with microscopic device features of 0.25 micrometers and smaller. Various temperature sensitive device parameters and device characteristics have recently been reported in the literature. Behavior of state of the art technology devices under such conditions needs to be evaluated in order to determine possible modifications in the device design for better performance and survivability under extreme environments. Here, we present a unique approach of developing electronics for extreme environments to benefit future NASA missions as described above. This will also benefit other long transit/life time missions such as the solar sail and planetary outposts in which electronics is out open in the unshielded space at the ambient space temperatures and always exposed to radiation. Additional information is contained in the original extended abstract.

Patel, J. U.↗

Lithium–Sulfur Batteries: 3D Printed Tools and Assembly Techniques for Repeatable Lab-Scale Coin Cell Manufacturing

The coin cell form factor has become a standard in energy storage research owing to its relatively low cost, low quantity of requisite electroactive material, fast experimental turnover, and capability to generate publishable quality data. Coin cell assembly at the lab-scale requires precise manual alignment of the many internal components of a cell to yield a properly functioning device. Truly repeatable device assembly presents a significant challenge to the acquisition of reliable data. In this report, we present a three-dimensional (3D) printable design for a coin cell alignment device and describe techniques for a generalized workflow to achieve reproducible coin cell assembly of lithium-based batteries. Standardized assembly techniques using readily accessible, purpose-built tools were demonstrated for labscale production of lithium−sulfur (Li−S) coin cells. Li−S batteries fabricated using the alignment device as well as conductive adhesive incorporated workflows afforded coin cells with up to 35% reduction of assembly times, comparable or better functional cell yields, and improved electrochemical device performance with more consistent and up to 150 mAh/g higher average discharge capacities coupled with Coulombic efficiency increases of up to 2.0% over manually aligned cell assembly techniques.

Batteries↗

Controlled, Site-Specific Functionalization of Carbon Nanotubes with Diazonium Salts

This work uses existing technologies to prepare a crossbar architecture of nano tubes, wherein one nanotube is fixed to a substrate, and a second nanotube is suspended a finite distance above. Both nano tubes can be individually addressed electrically. Application of opposite potentials to the two tubes causes the top tube to deform and to essentially come into contact with the lower tube. Contact here refers not to actual, physical contact, but rather within an infinitesimally small distance referred to as van der Walls contact, in which the entities may influence each other on a molecular and electronic scale. First, the top tube is physically deformed, leading to a potentially higher chemical reactivity at the point of deformation, based on current understanding of the effects of curvature strain on reactivity. This feature would allow selective functionalization at the junction via reaction with diazonium salts. Secondly, higher potential is achieved at the point of "cross" between the tubes. In a pending patent application, a method is claimed for directed self-assembly of molecular components onto the surface of metal or conductive materials by application of potential to the metal or conductive surface. In another pending patent application, a method is claimed for attaching molecules to the surface of nanotubes via the use of reactive diazonium salts. In the present invention, the directed functionalization of the crossed-nanotube junctions by applying a potential to the ends of the nanotubes in the presence of reactive diazonium slats, or other reactive molecular species is claimed. The diazonium salts are directed by the potential existing at the junction to react with the surface of the nanotube, thus placing functional molecular components at the junctions. The crossed nano tubes therefore provide a method of directly addressing the functionalized molecules, which have been shown to function as molecular switches, molecular wires, and in other capacities and uses. Site-specific functionalization may enable the use of nanotubes in molecular electronic applications because device functionality is critical at the cross points.

Tour, James M.↗

Aluminum/ammonia heat pipe gas generation and long term system impact for the Space Telescope's Wide Field Planetary Camera

In the Space Telescope's Wide Field Planetary Camera (WFPC) project, eight heat pipes (HPs) are used to remove heat from the camera's inner electronic sensors to the spacecraft's outer, cold radiator surface. For proper device functioning and maximization of the signal-to-noise ratios, the Charge Coupled Devices (CCD's) must be maintained at -95 C or lower. Thermoelectric coolers (TEC's) cool the CCD's, and heat pipes deliver each TEC's nominal six to eight watts of heat to the space radiator, which reaches an equilibrium temperature between -15 C to -70 C. An initial problem was related to the difficulty to produce gas-free aluminum/ammonia heat pipes. An investigation was, therefore, conducted to determine the cause of the gas generation and the impact of this gas on CCD cooling. In order to study the effect of gas slugs in the WFPC system, a separate HP was made. Attention is given to fabrication, testing, and heat pipe gas generation chemistry studies.

Jones, J. A.↗