Search NASA⌕ Search

SEARCH · Search NASA

Results for “fusion diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ultra-high speed photomultiplier tubes with nanosecond gating for fusion diagnostics

Fusion diagnostics can involve the measurement of ultra-fast optical pulses, often in close temporal proximity. We present a solution for the diagnostics of gamma reaction history and neutron time of flight by using microchannel plate based photomultiplier tubes (PMTs). The time response of the PMTs can be as fast as 100 ps FWHM and with a gain of up to 10{sup 7}. To observe small events in close temporal proximity to much larger signals such as the down-scattered fraction, the response of MCP-PMTs can be gated with an on/off ratio of up to 10{sup 13} in just 2 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved time response for large area microchannel plate photomultiplier tubes in fusion diagnostics

Fusion diagnostics that utilise high speed scintillators often need to capture a large area of light with a high degree of time accuracy. Microchannel plate (MCP) photomultiplier tubes (PMTs) are recognised as the leading device for capturing fast optical signals. However, when manufactured in their traditional proximity focused construction, the time response performance is reduced as the active area increases. This is due to two main factors: the capacitance of a large anode and the difficulty of obtaining small pore MCPs with a large area. Collaboration between Photek and AWE has produced prototype devices that combine the excellent time response of small area MCP-PMTs with a large active area by replacing the traditional proximity-gap front section with an electro-optically focused photocathode to MCP. We present results from both single and double MCP devices with a 40 mm diameter active area and show simulations for the 100 mm device being built this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy photocathodes for laser fusion diagnostics

Laser fusion experiments at the National Ignition Facility require time-resolved x-ray images of the ignition target self-emission. The photon energies are expected to be greater than 10 keV. Photoemission quantum yield measurement data and photoelectron energy spectrum data are presently unavailable in this photon energy range, but are essential in the design of x-ray imaging diagnostics. We developed an apparatus to measure the quantum efficiency of primary and secondary photoelectron emission and to estimate the energy spectrum of the secondary photoelectrons. The apparatus has been tested using photon energies less than 10 keV to allow comparisons with prior work. A method for preparing photocathodes with geometrically enhanced photoefficiency has been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gallium nitride (GaN) devices as a platform technology for radiation hard inertial confinement fusion diagnostics

Inertial Confinement Fusion (ICF) is undergoing more detailed research to increase neutron yield and will require high resolution imaging near the target. Neutron damage to diagnostics remains a serious issue in understanding and achieving ICF. We have demonstrated that Gallium Nitride (GaN) optoelectronic devices have exceptional neutron radiation hardness, by systematic testing of neutron radiation effects in GaN devices and materials with elevated neutron fluence levels and a broad neutron energy spectrum. During the 2013-2017 run cycles at Los Alamos Neutron Science Center (LANSCE), we irradiated various GaN materials and devices with fast and thermal plus resonance neutrons at several beamlines. This work presents a radiation hardness study for Aluminum Gallium Nitride and Gallium Nitride (AlGaN/GaN) deep UV LEDs irradiated at the LANSCE 4FP60R beamline. The fluence level was up to 2.4 × 10 13 neutrons/cm 2 for neutrons with energies greater than 0.1 MeV. The device performance was monitored in real time. After three years of irradiation studies, we found that the GaN devices maintained operation in the forward active region. The current and voltage relation (I-V curves) varied insignificantly in the linear region. Finally, our results demonstrate the radiation hardness needed for laser fusion diagnostics at least up to 10 17 neutron yield per shot, if the diagnostics is placed 1 m away from the target, where the neutron fluence per shot is approximately 8 × 10 11 n/cm 2 . The GaN devices can operate for multiple shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Field Quantum Diamond Magnetometers for Fusion Diagnostics (Final Technical Report)

Summary of research performed to enable all-optical quantum diamond magnetometers for fusion diagnostics, including: the physical mechanisms enabling all-optical photoluminescence contrast as a function of magnetic field magnitude and direction for dense ensembles of nitrogen vacancy (NV) centers in diamond; the characterization and optimization of NV-diamond material; and related investigations and student training.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superresolution of a compact neutron spectrometer at energies relevant for fusion diagnostics

The ability to achieve resolution that is better than the instrument resolution (i.e., superresolution) is well known in optics, where it has been extensively studied. Unfortunately, there are only a handful of theoretical studies concerning superresolution of particle spectrometers, even though experimentalists are familiar with the enhancement of resolution that is achievable when appropriate methods of data analysis are used, such as maximum entropy and Bayesian methods. Knowledge of the superresolution factor is in many cases important. For example, in applications of neutron spectrometry to fusion diagnostics, the temperature of a burning plasma is an important physical parameter which may be inferred from the width of the peak of the neutron energy spectrum, and the ability to determine this width depends on the superresolution factor. Kosarev has derived an absolute limit for resolution enhancement using arguments based on a well known theorem of Shannon. Most calculations of superresolution factors in the literature, however, are based on the assumption of Gaussian, translationally invariant response functions and therefore not directly applicable to neutron spectrometers which typically have response functions not satisfying these requirements. In this work, we develop a procedure that allows us to overcome these difficulties and we derive estimates of superresolution for liquid scintillator spectrometers of a type commonly used for neutron measurements. Theoretical superresolution factors are compared to experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical Study of Radiation from a Broad Range of Impurity Ions for Magnetic Fusion Diagnostics

Spectroscopy of radiation emitted by impurities plays an important role in the study of magnetically confined fusion plasmas. The measurements of these impurities are crucial for the control of the general machine conditions, for the monitoring of the impurity levels, and for the detection of various possible fault conditions. Low-Z impurities, typically present in concentrations of 1%, are lithium, beryllium, boron, carbon, and oxygen. Some of the common medium-Z impurities are metals such as iron, nickel, and copper, and high-Z impurities, such as tungsten, are present in smaller concentrations of 0.1% or less. Despite the relatively small concentration numbers, the aforementioned impurities might make a substantial contribution to radiated power, and also influence both plasma conditions and instruments. A detailed theoretical study of line radiation from impurities that covers a very broad spectral range from less than 1 Å to more than 1000 Å has been accomplished and the results were applied to the LLNL Electron Beam Ion Trap (EBIT) and the Sustained Spheromak Physics Experiment (SSPX) and to the National Spherical Torus Experiment (NSTX) at Princeton. Though low- and medium-Z impurities were also studied, the main emphasis was made on the comprehensive theoretical study of radiation from tungsten using different state-of-the-art atomic structure codes such as Relativistic Many-Body Perturbation Theory (RMBPT). The important component of this research was a comparison of the results from the RMBPT code with other codes such as the Multiconfigurational Hartree–Fock developed by Cowan (COWAN code) and the Multiconfiguration Relativistic Hebrew University Lawrence Atomic Code (HULLAC code), and estimation of accuracy of calculations. We also have studied dielectronic recombination, an important recombination process for fusion plasma, for variety of highly and low charged tungsten ions using COWAN and HULLAC codes. Accurate DR rate coefficients are needed for describing the ionization balance of plasmas, which in turn determines the lines contributing to the spectral emission and the radiative power loss. In particular, we have calculated relativistic atomic data and corresponding dielectronic satellite spectra of highly ionized W ions, such as, for example, Li-like W (with the shortest wavelength of x-ray radiation of about 0.2 Å) that might exist in ITER core plasmas at very high temperatures of 30-40 keV. In addition, we have completed relativistic calculations of low ionized W ions from Lu-like (W3+) to Er-like (W6+) and for Sm-like(W12+) and Pm-like (W13+) that cover a spectral range from few hundred to thousand Å and are more relevant to the edge plasma diagnostics in tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-efficiency, large-aperture fifth-harmonic: Generation of 211-nm pulses in ammonium dihydrogen phosphate crystals for fusion diagnostics

High-energy ultraviolet (UV) sources are required to probe hot dense plasmas from fusion experiments by using Thomson scattering resulting from the lower self-generated background from the plasma in the 180 to 230-nm spectral region. Although recently we demonstrated efficient, joule-class fifth harmonic conversion of 1053-nm pulses using a cesium lithium borate (CLBO) crystal, larger crystals are necessary for increased UV energy. This paper presents an alternative approach for fifth-harmonic generation of a large-aperture neodymium laser using ammonium dihydrogen phosphate (ADP). An Nd:YLF laser was optimized to produce square pulses with a flattop, square beam profile (1053 nm, 1 to 2.8 ns, 12 x 12 mm, ≤1.5 J, ≤5 Hz). Noncritical phase matching in ADP suitable for sum–frequency mixing the fourth harmonic with residual fundamental light was achieved by cooling the crystal (65 x 65 x 10 mm) in a two-chamber cryostat to 200 K. The crystal chamber used helium (1 atm) as the thermally conductive medium between the crystal and the crystal chamber, which in turn was surrounded by a high-vacuum chamber that contained a liquid nitrogen reservoir to cool the crystal chamber. Temperature variation of 0.4 K across the crystal aperture was obtained using two 50-W heaters with active feedback. The total conversion efficiency from the fundamental to the fifth harmonic, including surface losses and absorption, was 26%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Introduction to the special topic on inertial confinement fusion diagnostics

In the first decade of the 21st century, the United States began operating three leading Inertial Confinement Fusion (ICF) and High-Energy Density Physics (HEDP) facilities. The National Ignition Facility (NIF) began its quest to first surpass the Lawson Criterion and then reach thermonuclear ignition and thermonuclear gain. The Omega EP (Extended Performance) laser provides unprecedented energy, reliability, and consistency for petawatt (PW)-class laser experiments. The Omega laser continues to support over 1000 ICF and HEDP experiments each year. The Z pulsed power machine is a Z-pinch plasma confinement device that was refurbished to increase current drive and improve reliability. The extreme states of matter created in these new facilities required advancement of many technologies. The most important among these was the significant improvement in instrumentation capabilities needed to diagnose plasma conditions and resulting nuclear products. The instruments needed a better temporal, spatial, and energy resolution. They also needed to be hardened against EMP and radiation. Typical events in an ICF implosion include compressing the deuterium–tritium (DT) fuel to greater than 60 g/cm 3 and heating the DT to a temperature greater than 10 keV (110 000 000 K). The DT atoms react to produce 14 MeV neutrons from a volume with a radius of ~30 μm. When the fuel ignites, the DT burn prop agates into cold fuel and the neutron-emitting region can reach sizes of over 200 μm. Furthermore, the burn typically lasts less than 150 ps, but the burn duration will decrease as the DT yield increases. Burn durations as short as 90 ps have been recorded and are predicted to decrease still further to 20 ps. X-ray imaging diagnostics are needed to measure the acceleration and velocity of the capsule enclosing the DT, where the implosion velocities can reach over 400 km/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New developments for the determination of the response function for a BC501A compact neutron spectrometer for fusion diagnostics

The compact neutron spectrometer project was initiated to develop a device able to study fast neutrons produced by fusion reactions in a tokamak. The goal is to provide a fully characterized BC501A detector using a digital acquisition system developed by ENEA. The pulse height resolution and the response matrix of the detector are determined using experimental data acquired at the PTB facility. To achieve this goal, methods of data analysis involving entropy maximization and new software were developed. The methods are described and the current results for the pulse height resolution are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pr{sup 3+}-doped fluoro-oxide lithium glass as scintillator for nuclear fusion diagnostics

Experimental results are presented on the neutron scintillating properties of a custom-designed Pr3+(praseodymium)-doped lithium (Li) glass. Luminescence was observed at 278 nm wavelength, originating from the 5d-4f transition. Time-resolved measurements yielded about 20 ns decay times for ultraviolet and x-ray excitation while much faster decay times of about 6 ns were observed for alpha particle and neutron excitation. Actual time-of-flight data in laser fusion experiments at the GEKKO XII facility of the Institute of Laser Engineering, Osaka University reveal that it can clearly discriminate fusion neutrons from the much stronger x-rays signals. This material can promise improved accuracy in future scattered neutron diagnostics.

36 MATERIALS SCIENCE↗

Bayesian tomography and integrated data analysis in fusion diagnostics

In this article, a Bayesian tomography method using non-stationary Gaussian process for a prior has been introduced. The Bayesian formalism allows quantities which bear uncertainty to be expressed in the probabilistic form so that the uncertainty of a final solution can be fully resolved from the confidence interval of a posterior probability. Moreover, a consistency check of that solution can be performed by checking whether the misfits between predicted and measured data are reasonably within an assumed data error. In particular, the accuracy of reconstructions is significantly improved by using the non-stationary Gaussian process that can adapt to the varying smoothness of emission distribution. The implementation of this method to a soft X-ray diagnostics on HL-2A has been used to explore relevant physics in equilibrium and MHD instability modes. This project is carried out within a large size inference framework, aiming at an integrated analysis of heterogeneous diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute spectral characterization of silicon barrier diode: Application to soft X-ray fusion diagnostics at Tore Supra

This paper presents an experimental protocol for absolute calibration of photo-detectors. Spectral characterization is achieved by a methodology that unlike the usual line emissions-based method, hinges on the Bremsstrahlung radiation of a Soft X-Ray (SXR) tube only. Although the proposed methodology can be applied virtually to any detector, the application presented in this paper is based on Tore Supra's SXR diagnostics, which uses Silicon Surface Barrier Diodes. The spectral response of these n-p junctions had previously been estimated on a purely empirical basis. This time, a series of second-order effects, like the spatial distribution of the source radiated power or multi-channel analyser non linearity, are taken into account to achieve accurate measurements. Consequently, a parameterised physical model is fitted to experimental results and the existence of an unexpected dead layer (at least 5 {mu}m thick) is evidenced. This contribution also echoes a more general on-going effort in favour of long-term quality of passive radiation measurements on Tokamaks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthetic diagnostics platform for fusion plasmas (invited)

A Synthetic Diagnostics Platform (SDP) for fusion plasmas has been developed which provides state of the art synthetic reflectometry, beam emission spectroscopy, and Electron Cyclotron Emission (ECE) diagnostics. Interfaces to the plasma simulation codes GTC, XGC-1, GTS, and M3D-C{sup 1} are provided, enabling detailed validation of these codes. In this paper, we give an overview of SDP’s capabilities, and introduce the synthetic diagnostic modules. A recently developed synthetic ECE Imaging module which self-consistently includes refraction, diffraction, emission, and absorption effects is discussed in detail. Its capabilities are demonstrated on two model plasmas. The importance of synthetic diagnostics in validation is shown by applying the SDP to M3D-C{sup 1} output and comparing it with measurements from an edge harmonic oscillation mode on DIII-D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Millimeter-Wave Imaging Technology Development for Real-Time 2D and 3D Fusion Plasma Diagnostics

Including a one year No-Cost Extension, The University of California, Davis has been funded since 2020 to advance innovative millimeter-wave diagnostics for fusion plasma research. This work includes: (1) Developing and applying cutting-edge System-on-Chip millimeter wave Integrated Circuit (IC) technology for Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometry (MIR) on the DIII-D tokamak and the NSTX-U spherical tokamak. (2) Development of radiation-hardened millimeter-wave chip for diagnostics in harsh environments, utilizing wide bandgap Gallium Nitride (GaN) semiconductors. (3) Integrating forward-modeling synthetic diagnostics to enable advanced, real-time plasma prediction and feedback control. Originally planned as a three-year program (2020–2023), the project was granted a one-year no-cost extension, extending its duration through the end of 2024.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗