Spatiotemporal characterization of cerium monoxide in laser ablation plasmas using spectrally-resolved fast-gated imaging

The impact of oxidation chemistry on the emission characteristics and spatial structure of laser-produced Ce metal plasmas was investigated using laser-induced breakdown spectroscopy (LIBS) and time-resolved fast-gated imaging employing narrowband optical filters. Images of the plasma emission show that CeO coexists with atomic species in the periphery and vortex ring of the plasma plume. Image processing was also applied to combine independent monochromatic images of the plasma emission into a single merged image, culminating in a timelapse on the spatiotemporal evolution of atomic and molecular species within the plasma plume. The formation of CeO species was observed to proceed faster for plasmas generated in atmospheres containing larger concentrations of oxygen based on ratios of CeO-to-atomic emission intensities. Furthermore, these same ratios were shown to plateau and decrease at later times (≥25 μs), potentially indicating the depletion of CeO number densities in the plasma as the monoxide undergoes reactions to form higher polyatomic oxides. Altogether, these results provide fundamental insights into the chemical dynamics and intermixing between plasma-gas species in laser ablation cerium plasmas, advancing our understanding on optical signatures of nuclear-relevant materials to enable in-field measurement capabilities.

47 OTHER INSTRUMENTATION↗

Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗

Imaging gate-tunable Tomonaga–Luttinger liquids in 1H-MoSe 2 mirror twin boundaries

One-dimensional electron systems exhibit fundamentally different properties than higher-dimensional systems. For example, electron-electron interactions in one-dimensional electron systems have been predicted to induce Tomonaga-Luttinger liquid behaviour. Naturally occurring grain boundaries in single-layer transition metal dichalcogenides exhibit one-dimensional conducting channels that have been proposed to host Tomonaga-Luttinger liquids, but charge density wave physics has also been suggested to explain their behaviour. Clear identification of the electronic ground state of this system has been hampered by an inability to electrostatically gate such boundaries and tune their charge carrier concentration. Here we present a scanning tunnelling microscopy and spectroscopy study of gate-tunable mirror twin boundaries in single-layer 1H-MoSe 2 devices. Gating enables scanning tunnelling microscopy and spectroscopy for different mirror twin boundary electron densities, thus allowing precise characterization of electron-electron interaction effects. Visualization of the resulting mirror twin boundary electronic structure allows unambiguous identification of collective density wave excitations having two velocities, in quantitative agreement with the spin-charge separation predicted by finite-length Tomonaga-Luttinger liquid theory.

36 MATERIALS SCIENCE↗

NIR fluorescence lifetime macroscopic imaging with a novel time-gated SPAD camera

SwissSPAD3 is the latest of a family of widefield time-gated SPAD imagers developed for fluorescence lifetime imaging (FLI) applications. Its distinctive features are (i) the ability to define shorter gates than its predecessors (width W < 1 ns), (ii) support for laser repetition rates up to at least 80 MHz and (iii) a dual-gate architecture providing an effective duty cycle of 100%. We present widefield macroscopic FLI measurements of short lifetime NIR dyes, analyzed using the phasor approach. Furthermore, the results are compared with those previously obtained with SwissSPAD2 and to theoretical predictions.

47 OTHER INSTRUMENTATION↗

Image Station Use Examples from DARHT [Slides]

This presentation covers these topics: the beam envelope equation for tuning, Optical Transition Radiation (OTR), the solenoid scan method for beam identification, the Pepper-pot method for beam identification, and Beam-target studies via gated imaging.

43 PARTICLE ACCELERATORS↗

Diagnosing low-mode (ℓ < 6) and mid-mode (6 ≤ ℓ ≤ 60) asymmetries in the post-stagnation phase of laser-direct-drive deuterium–tritium cryogenic implosions on OMEGA

Low- and mid-mode perturbations are possible candidates for performance limitations in cryogenic direct-drive implosions on the OMEGA laser at the Laboratory of Laser Energetics. Simulations with a 3D hydrocode demonstrated that hotspot imagers do not show evidence of the shell breakup in the dense fuel. However, these same simulations revealed that the low- and mid-mode perturbations in the dense fuel could be diagnosed more easily in the post-stagnation phase of the implosion by analyzing the peak in the x-ray emission limb at the coronal–fuel interface than before or at the stagnation phase. In experiments, the asymmetries are inferred from gated images of the x-ray emission of the implosion by using a 16-pinhole array imager filtered to record x-ray energies >800 eV and an x-ray framing camera with 40-ps time integration and 20-μm spatial resolution. Furthermore, a modal analysis is applied to the spatial distribution of the x-ray emission from deuterium and tritium cryogenic implosions on OMEGA recorded after the bang time to diagnose the low- and mid-mode asymmetries, and to study the effect that the beam-to-target ratio (Rb/Rt) has on the shell integrity.

47 OTHER INSTRUMENTATION↗

NIR fluorescence lifetime macroscopic imaging with a time-gated SPAD camera

The performance of SwissSPAD2 (SS2), a large scale, widefield time-gated CMOS SPAD imager developed for fluorescence lifetime imaging, has recently been described in the context of visible range and fluorescence lifetime imaging microscopy (FLIM) of dyes with lifetimes in the 2.5 – 4 ns range. Here, we explore its capabilities in the NIR regime relevant for small animal imaging, where its sensitivity is lower and typical NIR fluorescent dye lifetimes are much shorter (1 ns or less). We carry out this study in a simple macroscopic imaging setup based on a compact NIR picosecond pulsed laser, an engineered diffuser-based illumination optics, and NIR optimized imaging lens suitable for well-plate or small animal imaging. Because laser repetition rates can vary between models, but the synchronization signal frequency accepted by SS2 is fixed to 20 MHz, we first checked that a simple frequency-division scheme enables data recording for different laser repetition rates. Next, we acquired data using different time gate widths, including gates with duration longer than the laser period, and analyzed the resulting data using both standard nonlinear least-square fit (NLSF) and phasor analysis. We show that the fixed synchronization rate and large gate widths characterizing SS2 (10 ns and over) are not an obstacle to accurately extracting lifetime in the 1 ns range and to distinguishing between close lifetimes. As a result, SS2 and similar very large gated SPAD imagers appear as a versatile alternative to other widefield time-resolved detectors for NIR fluorescence lifetime imaging, including preclinical molecular applications.

FLIM↗

Seeding the explosion of a high-current-density conductor in a controlled manner through the addition of micron-scale surface defects

Inhomogeneities in a current-carrying conductor promote non-uniform heating and expansion through the complex feedback between current density, electrical resistivity, Ohmic heating, temperature, and hydrodynamics. Three-dimensional-magnetohydrodynamic (3D-MHD) simulations suggest that μm-scale resistive inclusions or voids seed local overheating and through hydrodynamic explosion generate continuously growing craters which become several times larger than the initial perturbation. The ejected mass is the genesis of an electrothermally driven plasma filament which develops at lower current than plasmas on uniform surfaces adjacent to the defect. This result suggests that 1D or even 2D treatments are largely inadequate for detailed prediction of plasma formation. To test computational predictions, z-pinch experiments driven to 1 MA studied ultra-high-purity aluminum rods which were then machined to include pairs of quasi-hemispherical voids or “engineered defects (ED)” on the current-carrying surface. ED are the dominant current-density perturbation and reproducibly drive local overheating which can be compared with 3D-MHD simulation. Data from high-resolution-gated imagers of visible surface emissions confirm many simulation predictions, including the surface topography of local overheating, and the propensity for neighboring ED to prematurely source plasmas which then connect to form a plasma filament. Results also provide conditional support of theory which suggests heating similarity; that is, heating is independent of ED size for geometrically scaled ED.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the initiation and evolution of dielectric breakdown in auto-magnetizing liner experiments

Auto-magnetizing (AutoMag) liners are cylindrical tubes composed of discrete metallic helices encapsulated in insulating material; when driven with a ~2 MA, ~100-ns prepulse on the 20 MA, 100-ns rise time Z accelerator, AutoMag targets produced >150 T internal axial magnetic fields. Once the current rise rate of the pulsed power driver reaches sufficient magnitude, the induced electric fields in the liner cause dielectric breakdown of the insulator material and, with sufficient current, the cylindrical target radially implodes. The dielectric breakdown process of the insulating material in AutoMag liners has been studied in experiments on the 500–900 kA, ~100-ns rise time Mykonos accelerator. Multi-frame gated imaging enabled the first time-resolved observations of photoemission from dynamically evolving plasma distributions during the breakdown process in AutoMag targets. Using magnetohydrodynamic simulations, we calculate the induced electric field distribution and provide a detailed comparison to the experimental data. We find that breakdown in AutoMag targets does not primarily depend on the induced electric field in the gaps between conductive helices as previously thought. Finally, to better control the dielectric breakdown time, a 12–32 mJ, 170 ps ultraviolet (λ = 266 nm) laser was implemented to irradiate the outer surface of AutoMag targets to promote breakdown in a controlled manner at a lower internal axial field. Here, the laser had an observable effect on the time of breakdown and subsequent plasma evolution, indicating that pulsed UV lasers can be used to control breakdown timing in AutoMag.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Investigation of high field plasma dynamics in a laser-produced plasma expanding into a background gas

This paper presents an overview of experimental results of a laser-produced plasma expanding into a background gas, immersed within a large range of highly uniform magnetic fields (of up to 3 T), that are transverse to the expanding plasma. We used intensified gated imaging to capture the expansion of the plasma across and along the magnetic field lines to observe the spatiotemporal expansion dynamics for different magnetic field strengths. We observe changes in the perpendicular and parallel dynamics of the laser-produced plasmas expansion at high magnetic field. In addition, our results have also indicated the presence of electron-ion hybrid instabilities at relatively high pressures (100 mTorr) and relatively high magnetic field strengths (2 T), in accordance with theoretical calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Frame Gated X-Ray Imager Report

The Multi-Frame Gated X-ray Imager (MGXI) project for the Lawrence Livermore National Laboratory (LLNL) with Project Leader Arthur Carpenter has finished its third year of collaboration with PI Charles Hunt in the ECE Department at UC Davis. This Target Area Science Engineering (TASE) project is part of the National Ignition Facility (NIF) and receives federal funding from the Department of Energy under contract B639825 for the Vacuum Microelectronics (VME) Group to conduct the yearly objectives. The ultimate goal is to construct a burst-mode x-ray imager with multiple frames with as low as ≤25μm spatial resolution and 50ps temporal resolution for use with x-rays in the 5-75keV range; and when coupled to an optically sensitive transmission photocathode (such as an S20) 400-700nm visible range.

42 ENGINEERING↗

Understanding ICF hohlraums using NIF gated laser-entrance-hole images

The newly available ns-gated laser-entrance-hole (LEH) imager on the National Ignition Facility provides routine, non-perturbative measurements of the x-ray emission from laser-heated plasmas inside the hohlraum as viewed at 19° to the hohlraum axis through one of its LEHs. Multiple images are acquired for a series of times and filter-selected x-ray energy bands within a single shot. The images provide time dependent data on phenomena including the effective radius of the LEH, the length of the gold-plasma “bubble” evolving off the interior wall surface heated by the outer beams, the evolving radius of the x-ray heated hohlraum wall, and the radius of the ablation front of the fusion capsule. Here, these measurements are explained and illustrated with sample data. These techniques are then applied to understand hohlraum behavior as a function of gas fill. For hohlraums with helium gas fill densities of 0.15 to 0.30 mg/cm 3 , synthetic images computed from simulations agree well with experimental gated LEH images when an inhibited heat transport model [Jones et al., Phys. Plasmas 24, 056312 (2017)] is used. This model can be adjusted to reproduce the expansion rate of the laser-heated plasma bubble in such a way as to improve agreement with the images. At the higher 0.6 mg/cc gas fill, the experimental images show more pronounced 3D features, resulting in slightly less good agreement with the 2D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Imaging on Z LDRD: Design and Development of Self-Emission and Debris Imagers

We present an overview of the design and development of optical self-emission and debris imaging diagnostics for the Z Machine at Sandia National Laboratories. These diagnostics were designed and implemented to address several gaps in our understanding of visibly emitting phenomenon on Z and the post-shot debris environment. Optical emission arises from plasmas that form on the transmission line that delivers energy to Z loads and on the Z targets themselves; however, the dynamics of these plasmas are difficult to assess without imaging data. Addressing this, we developed a new optical imager called SEGOI (Self-Emission Gated Optical Imager) that leverages the eight gated optical imagers and two streak cameras of the Z Line VISAR system. SEGOI is a low cost, side-on imager with a 1 cm field of view and 30-50 µm spatial resolution, sensitive to green light (540-600 nm). This report outlines the design considerations and development of this diagnostic and presents an overview of the first diagnostic data acquired from four experimental campaigns. SEGOI was fielded on power flow experiments to image plasmas forming on and between transmission lines, on an inertial confinement fusion experiment called the Dynamic Screw Pinch to image low density plasmas forming on return current posts, on an experiment designed to measure the magneto Rayleigh-Taylor instability to image the instability bubble trajectory and self-emission structures, and finally on a Magnetized Liner Inertial Fusion (MagLIF) experiment to image the emission from the target. The second diagnostic developed, called DINGOZ (Debris ImagiNG on Z), was designed to improve our understanding of the post-shot debris environment. DINGOZ is an airtight enclosure that houses electronics and batteries to operate a high-speed (10-400 kfps) camera in the Z Machine center section. We report on the design considerations of this new diagnostic and present the first high-speed imaging data of the post-shot debris environment on Z.

42 ENGINEERING↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

The design of a line velocity interferometer for any reflector for inertial confinement experiments on the Z-machine

A line VISAR (Velocity Interferometer System for Any Reflector) has been designed and commissioned at the Sandia National Laboratory’s Z-machine. The instrument consists of an F/2 collection system, beam transport, and an interferometer table that contains two Mach–Zehnder type interferometers and an eight channel Gated Optical Imaging (GOI) system. The VISAR probe laser operates at the 532 nm wavelength, and the GOI bandpass is 540–600 nm. The output of each interferometer is passed to an optical streak camera with four selectable sweep speeds. The system is designed with three interchangeable optics modules to select a full field of view of 1 mm, 2 mm, or 4 mm. The optical beam transport system connects the target image plane to the interferometers and the gated optical imagers. The target is integrated into a sacrificial final optics assembly that is integral to the transport beamline.

Datte, P.↗

Upgrade of the gated laser entrance hole imager G-LEH-2 on the National Ignition Facility

A major upgrade has been implemented for the ns-gated laser entrance hole imager on the National Ignition Facility (NIF) to obtain high-quality data for Hohlraum physics study. In this upgrade, the single “Furi” hCMOS sensor (1024 × 448 pixel arrays with two-frame capability) is replaced with dual “Icarus” sensors (1024 × 512 pixel arrays with four-frame capability). Both types of sensors were developed by Sandia National Laboratories for high energy density physics experiments. With the new Icarus sensors, the new diagnostic provides twice the detection area with improved uniformity, wider temporal coverage, flexible timing setup, and greater sensitivity to soft x rays (<2 keV). These features, together with the fact that the diagnostic is radiation hardened and can be operated on the NIF for high neutron yield deuterium–triterium experiments, enable significantly greater return of data per experiment.

47 OTHER INSTRUMENTATION↗