New optical scheme for a polarimetric-based glucose sensor

A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient's eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Evaluation Studies↗

A New Optical Scheme for a Polarimetric-Based Glucose Sensor

We describe a new optical scheme to perform polarimetric measurements to detect glucose concentration in the aqueous humor of a model eye. The ultimate aim is to apply this technique in designing a new instrument for measuring glucose levels in diabetic patients routinely, frequently, and non-invasively. The scheme exploits the Brewsterreflection of circularly polarized light off of the lens of the eye. Theoretically, this backreflected linearly polarized light on its way to the detector is expected to rotate its state of polarization due to the presence of glucose molecules in the aqueous humor of patients. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentration of glucose solutions dissolved in water.

Ansari, Rafat R.↗

Engineered Glucose Oxidase‐Carbon Nanotube Conjugates for Tissue‐Translatable Glucose Nanosensors

Abstract Continuous and non‐invasive glucose monitoring and imaging is important for disease diagnosis, treatment, and management. However, glucose monitoring remains a technical challenge owing to the dearth of tissue‐transparent glucose sensors. In this study, we present the development of near‐infrared fluorescent single‐walled carbon nanotube (SWCNT) based nanosensors directly functionalized with glucose oxidase (GOx) capable of immediate and reversible glucose imaging in biological fluids and tissues. We prepared GOx‐SWCNT nanosensors by facile sonication of SWCNT with GOx in a manner that—surprisingly—does not compromise the ability of GOx to detect glucose. Importantly, we find by using denatured GOx that the fluorescence modulation of GOx‐SWCNT is not associated with the catalytic oxidation of glucose but rather triggered by glucose‐GOx binding. Leveraging the unique response mechanism of GOx‐SWCNT nanosensors, we developed catalytically inactive apo‐GOx‐SWCNT that enables both sensitive and reversible glucose imaging, exhibiting a ΔF/F 0 of up to 40 % within 1 s of exposure to glucose without consuming the glucose analyte. We finally demonstrate the potential applicability of apo‐GOx‐SWCNT in biomedical applications by glucose quantification in human plasma and glucose imaging in mouse brain slices.

Chemistry↗

From small changes to big gains: pyridinium-based tetralactam macrocycle for enhanced sugar recognition in water

The complex distribution of functional groups in carbohydrates, coupled with their strong solvation in water, makes them challenging targets for synthetic receptors. Despite extensive research into various molecular frameworks, most synthetic carbohydrate receptors have exhibited low affinities, and their interactions with sugars in aqueous environments remain poorly understood. In this work, we present a simple pyridinium-based hydrogen-bonding receptor derived from a subtle structural modification of a well-known tetralactam macrocycle. This small structural change resulted in a dramatic enhancement of glucose binding affinity, increasing from 56 M −1 to 3001 M −1 . Remarkably, the performance of our synthetic lectin surpasses that of the natural lectin, concanavalin A, by over fivefold. X-ray crystallography of the macrocycle–glucose complex reveals a distinctive hydrogen bonding pattern, which allows for a larger surface overlap between the receptor and glucose, contributing to the enhanced affinity. Furthermore, this receptor possesses allosteric binding sites, which involve chloride binding and trigger receptor aggregation. This unique allosteric process reveals the critical role of structural flexibility in this hydrogen-bonding receptor for the effective recognition of sugars. We also demonstrate the potential of this synthetic lectin as a highly sensitive glucose sensor in aqueous solutions.

Zhai, Canjia↗

Method for Texturing Surfaces of Optical Fiber Sensors Used for Blood Glucose Monitoring

Disclosed is a method and the resulting product thereof comprising a solid light-conducting fiber with a point of attachment and having a textured surface site consisting a textured distal end prepared by being placed in a vacuum and then subjected to directed hyperthermal beams comprising oxygen ions or atoms. The textured distal end comprises cones or pillars that are spaced upon from each other by less than 1 micron and are extremely suitable to prevent cellular components of blood from entering the valleys between the cones or pillars so as to effectively separate the cellular components in the blood from interfering with optical sensing of the glucose concentration for diabetic patients.

Banks, Bruce A.↗

Improved Oxygen-Beam Texturing of Glucose-Monitoring Optics

An improved method has been devised for using directed, hyperthermal beams of oxygen atoms and ions to impart desired textures to the tips of polymethylmethacrylate [PMMA] optical fibers to be used in monitoring the glucose content of blood. The improved method incorporates, but goes beyond, the method described in Texturing Blood-Glucose- Monitoring Optics Using Oxygen Beams (LEW-17642-1), NASA Tech Briefs, Vol. 29, No. 4 (April 2005), page 11a. The basic principle of operation of such a glucose-monitoring sensor is as follows: The textured surface of the optical fiber is coated with chemicals that interact with glucose in such a manner as to change the reflectance of the surface. Light is sent down the optical fiber and is reflected from, the textured surface. The resulting change in reflectance of the light is measured as an indication of the concentration of glucose. The required texture on the ends of the optical fibers is a landscape of microscopic cones or pillars having high aspect ratios (microscopic structures being taller than they are wide). The average distance between hills must be no more than about 5 mso that blood cells (which are wider) cannot enter the valleys between the hills, where they would interfere with optical sensing of glucose in the blood plasma. On the other hand, the plasma is required to enter the valleys, and high aspect ratio structures are needed to maximize the surface area in contact with the plasma, thereby making it possible to obtain a given level of optical glucose-measurement sensitivity with a relatively small volume of blood. There is an additional requirement that the hills be wide enough that a sufficient amount of light can propagate into them and, after reflection, can propagate out of them. The method described in the cited prior article produces a texture comprising cones and pillars that conform to the average-distance and aspect-ratio requirements. However, a significant fraction of the cones and pillars are so narrow that not enough light can propagate along them. The improved method makes it possible to form wider cones and pillars while still satisfying the average-distance and aspect-ratio requirements. In the improved method, as in the previously reported method, multiple optical fibers are first bundled together for simultaneous texturing of their distal tips. However, prior to texturing by exposure to an oxygen beam, the tips are first coated by vapor deposition of a thin, sparse layer of aluminum: The exposure to the aluminum vapor must be short enough (typically of the order of seconds) so that the aluminum nucleates into islands separated by uncoated areas. The coated tips are textured by exposure to a directed beam of hyperthermal (kinetic energy >1 eV) oxygen atoms and/or ions in a vacuum chamber, as in the previously reported method. The aluminum islands partially shield the underlying PMMA from oxidation and erosion by the beam, so that the cones or pillars remaining after texturing are wider than they would otherwise be. To some extent, the dimensions of the hills and the distances between them can be tailored through choice of the thickness of the aluminum coat and/or the oxygen-beam fluence. The figure illustrates an example of texturing of the tip of a PMMA optical fiber without and with prior aluminum coating.

Banks, Bruce A.↗

Non-invasive optical detection of glucose in cell culture nutrient medium

The objective of the proposed research was to begin the development of a non-invasive optical sensor for measuring glucose concentration in the output medium of cell cultures grown in a unique NASA bioreactor referred to as an integrated rotating-wall vessel (IRWV). The input, a bovine serum based nutrient media, has a known glucose concentration. The cells within the bioreactor digest a portion of the glucose. Thus, the non-invasive optical sensor is needed to monitor the decrease in glucose due to cellular consumption since the critical parameters for sustained cellular productivity are glucose and pH. Previous glucose sensing techniques have used chemical reactions to quantify the glucose concentration. Chemical reactions, however, cannot provide for continuous, real time, non-invasive measurement as is required in this application. Our effort while in the fellowship program was focused on the design, optical setup, and testing of one bench top prototype non-invasive optical sensor using a mid-infrared absorption spectroscopy technique. Glucose has a fundamental vibrational absorption peak in the mid-infrared wavelength range at 9.6 micron. Preliminary absorption data using a CO2 laser were collected at this wavelength for water based glucose solutions at different concentrations and one bovine serum based nutrient medium (GTSF) with added glucose. The results showed near linear absorption responses for the glucose-in-water data with resolutions as high at 108 mg/dl and as low as 10 mg/dl. The nutrient medium had a resolution of 291 mg/dl. The variability of the results was due mainly to thermal and polarization drifts of the laser while the decrease in sensitivity to glucose in the nutrient medium was expected due to the increase in the number of confounders present in the nutrient medium. A multispectral approach needs to be used to compensate for these confounders. The CO2 laser used for these studies was wavelength tunable (9.2 to 10.8 micrometers), however, it was to unstable across wavelengths to test the multispectral approach. From this research, further NASA support was obtained to continue the work throughout the year in which a more stable light source will be used at smaller, near-infrared, wavelengths. It is anticipated that a more compact, non-invasive, optical glucose sensor will be realized which can be used with a bioreactor on future space shuttle missions. It is also anticipated that a multispectral optical sensor may be used to determine the concentration of other molecules needed within the NASA bioreactor, such as fructose and galactose.

Cote, Gerald L.↗

Tailoring the d-band center on Ru 1 Cu single-atom alloy nanotubes for boosting electrochemical non-enzymatic glucose sensing

The development of cost-effective and highly efficient electrocatalysts is critical to help electrochemical non-enzymatic sensors achieve high performance. Here, in this work, a new class of catalyst, Ru single atoms confined on Cu nanotubes as a single-atom alloy (Ru 1 Cu NTs), with a unique electronic structure and property, was developed to construct a novel electrochemical non-enzymatic glucose sensor for the first time. The Ru 1 Cu NTs with a diameter of about 24.0 nm showed a much lower oxidation potential (0.38 V) and 9.0-fold higher response (66.5 μA) current than Cu nanowires (Cu NWs, oxidation potential 0.47 V and current 7.4 μA) for glucose electrocatalysis. Moreover, as an electrochemical non-enzymatic glucose sensor, Ru1Cu NTs not only exhibited twofold higher sensitivity (54.9 μA mM −1 cm −2 ) and wider linear range (0.5–8 mM) than Cu NWs, but also showed a low detection limit (5.0 μM), excellent selectivity, and great stability. According to theoretical calculation results, the outstanding catalytic and sensing performance of Ru 1 Cu NTs could be ascribed to the upshift of the d-band center that helped promote glucose adsorption. This work presents a new avenue for developing highly active catalysts for electrochemical non-enzymatic sensors.

electrochemistry↗

ISS Biotechnology Facility - Overview of Analytical Tools for Cellular Biotechnology Investigations

The ISS Biotechnology Facility (BTF) platform provides scientists with a unique opportunity to carry out diverse experiments in a microgravity environment for an extended period of time. Although considerable progress has been made in preserving cells on the ISS for long periods of time for later return to Earth, future biotechnology experiments would desirably monitor, process, and analyze cells in a timely way on-orbit. One aspect of our work has been directed towards developing biochemical sensors for pH, glucose, oxygen, and carbon dioxide for perfused bioreactor system developed at Johnson Space Center. Another aspect is the examination and identification of new and advanced commercial biotechnologies that may have applications to on-orbit experiments.

Jeevarajan, A. S.↗

Oxide derived Cu nanofibril assembly for enhanced nonenzymatic glucose sensing

In this report, we have prepared copper nanofibril assembly via thermal oxidation followed by electrochemical reduction processes, exhibiting superior glucose detection ability. The morphological analysis evidenced the formation of rough islands or nanofibril structure on the Cu surface depending on initial thermal oxidation temperature. The glucose detection performance was investigated by performing cyclic voltammetry and chronoamperometry with varying glucose concentration. A high sensitivity (4131.57 μA mM – 1 cm – 2 ), low detection limit (1.41 μM), wider linear range (0–3.9 mM) and long–term stability (30 days) have been recorded for electrode thermally oxidized at 400 °C followed by electrochemical reduction process (rCu_400). The sensitivity is almost three times higher in comparison to the planner Cu surface. This significantly enhanced glucose sensing ability rCu_400 has been attributed to the nanofibril morphology, origination of Cu (111) facet and formation of a stable oxide layer evidenced by scanning electron microscopy, X-ray diffraction and energy dispersive spectroscopy analysis. Despite higher sensitivity, rCu_400 electrode does not show any response to the chloride ion, dopamine, ascorbic acid and uric acid. Finally, these results indicate that the Cu nanofibril structure prepared via simple oxidation/reduction process can be an excellent candidate to be used as an electrode for glucose sensing application.

36 MATERIALS SCIENCE↗

Electron tunneling infrared sensor module with integrated control circuitry

In an integrated electron tunneling sensor, an automatic tunneling control circuit varies a high voltage bias applied to the sensor deflection electrode in response to changes in sensor output to maintain the proper gap between the sensor tip and membrane. The control circuit ensures stable tunneling activity in the presence of large signals and other disturbances to the sensor. Output signals from the module may be derived from the amplified sensor output. The integrated sensor module is particularly well adapted for use in blood glucose measurement and monitoring system.

Boyadzhyan-Sevak, Vardkes V.↗

Nanopore Device for Reversible Ion and Molecule Sensing or Migration

Disclosed are methods and devices for detection of ion migration and binding, utilizing a nanopipette adapted for use in an electrochemical sensing circuit. The nanopipette may be functionalized on its interior bore with metal chelators for binding and sensing metal ions or other specific binding molecules such as boronic acid for binding and sensing glucose. Such a functionalized nanopipette is comprised in an electrical sensor that detects when the nanopipette selectively and reversibly binds ions or small molecules. Also disclosed is a nanoreactor, comprising a nanopipette, for controlling precipitation in aqueous solutions by voltage-directed ion migration, wherein ions may be directed out of the interior bore by a repulsing charge in the bore.

Pourmand, Nader↗

Nanopore device for reversible ion and molecule sensing or migration

Disclosed are methods and devices for detection of ion migration and binding, utilizing a nanopipette adapted for use in an electrochemical sensing circuit. The nanopipette may be functionalized on its interior bore with metal chelators for binding and sensing metal ions or other specific binding molecules such as boronic acid for binding and sensing glucose. Such a functionalized nanopipette is comprised in an electrical sensor that detects when the nanopipette selectively and reversibly binds ions or small molecules. Also disclosed is a nanoreactor, comprising a nanopipette, for controlling precipitation in aqueous solutions by voltage-directed ion migration, wherein ions may be directed out of the interior bore by a repulsing charge in the bore.

47 OTHER INSTRUMENTATION↗

Light-triggered electrochemical biosensor using singlet oxygen for self-powered operation and glucose detection

This study introduces a light-activated sensing strategy that integrates photosensitization with electrochemical detection. The sensor employs Eosin Y, a photosensitizer that generates singlet oxygen ( 1 O 2 ) via type II photosensitization. Immobilized within a thin polymer matrix on a carbon working electrode, Eosin Y produces 1 O 2 , under green light (520 nm) illumination, initiating a redox process that yields a measurable current. To incorporate biosensing capabilities and enable self-powered operation, this 1 O 2 – mediated process was coupled with glucose oxidase (GOx) to construct a fully operational glucose biosensor. The addition of glucose reverses the current flow by causing GOx to compete for electrons, with the resulting current magnitude correlating with glucose concentration providing a sensitive measure of glucose. The biosensor, as proof-of-principle, demonstrated excellent performance over a range of glucose concentrations (0–73 mM), achieving a detection limit (LOD) of 2.8 mM for steady state photocurrent under oxygen-saturated conditions. This platform leverages light and 1 O 2 as stimuli for tunable, on-demand signal control, offering a novel approach for adaptive, real-time biosensing technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

54 ENVIRONMENTAL SCIENCES↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

60 - APPLIED LIFE SCIENCES↗

Replaceable Sensor System for Bioreactor Monitoring

A sensor system was proposed that would monitor spaceflight bioreactor parameters. Not only will this technology be invaluable in the space program for which it was developed, it will find applications in medical science and industrial laboratories as well. Using frequency-domain-based fluorescence lifetime technology, the sensor system will be able to detect changes in fluorescence lifetime quenching that results from displacement of fluorophorelabeled receptors bound to target ligands. This device will be used to monitor and regulate bioreactor parameters including glucose, pH, oxygen pressure (pO2), and carbon dioxide pressure (pCO2). Moreover, these biosensor fluorophore receptor-quenching complexes can be designed to further detect and monitor for potential biohazards, bioproducts, or bioimpurities. Biosensors used to detect biological fluid constituents have already been developed that employ a number of strategies, including invasive microelectrodes (e.g., dark electrodes), optical techniques including fluorescence, and membrane permeable systems based on osmotic pressure. Yet the longevity of any of these sensors does not meet the demands of extended use in spacecraft habitat or bioreactor monitoring. It was therefore necessary to develop a sensor platform that could determine not only fluid variables such as glucose concentration, pO2, pCO2, and pH but can also regulate these fluid variables with controlled feedback loop.

Mayo, Mike↗