Search NASA⌕ Search

SEARCH · Search NASA

Results for “governor response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advanced Performance Metrics and their Application to the Sensitivity Analysis for Model Validation and Calibration

High-quality generator dynamic models are critical to reliable and accurate power systems studies and planning. With the availability of PMUs, measurement-based approach for model validation has gained significant prominence. In this approach, the quality of a model is analyzed by visually comparing measured generator response with the model-based simulated response for large system disturbances. This paper proposes a new set of performance metrics to assess the model validation results to facilitate automation of the model validation process. In the proposed methodology, first, the slow governor response and comparatively faster oscillatory response are separated, and then a separate set of performance metrics is calculated for each of these two components. These proposed metrics quantify the mismatch between the actual and model-based response in a comprehensive manner without missing any information enabling automation of the process. Furthermore, in this paper, we are also proposing that the sensitivity analysis for model calibration be performed with respect to the proposed metrics for the systematic identification of key parameters. In this work, results obtained using both simulated and real-world case-studies validate the effectiveness of the proposed performance metrics for model validation and their application to the sensitivity analysis for model calibration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A simulation investigation of the effects of engine-and thrust-response characteristics on helicopter handling qualities

A multi-phase program is being conducted to study, in a generic sense and through ground simulation, the effects of engine response, rotor inertia, rpm control, excess power, and vertical damping on specific maneuvers included in nap-of-the-Earth (NOE) operations. The helicopter configuration with an rpm-governed gas-turbine engine are considered. Handling-qualities-criteria data are considered in light of aspects peculiar to rotary-wing and NOE operations. The results of three moving-based piloted simulation studies are summarized and the frequency, characteristics of the helicopter thrust response which set it apart from other VTOL types are explained. Power-system response is affected by both the engine-governor response and the level of rotor inertia. However, results indicate that with unlimited power, variations in engine response can have a significant effect on pilot rating, whereas changes in rotor inertia, in general, do not. The results also show that any pilot interaction required to maintain proper control can significantly degrade handling qualities. Data for variations in vertical damping and collective sensitivity are compared with existing handling-qualities specifications, MIL-F-83300 and AGARD 577, and show a need for higher minimums for both damping and sensitivity for the bob-up task. Results for cases of limited power are also shown.

Corless, L. D.↗

Measurement-Based Approach for Inertia-Trend Analysis of the US Western Interconnection

Rising deployment of inverter-based resources (IBRs), characterized by a lack of rotating mass, is decreasing the total inertia of the system. This can lead to an increased Rate of Change of Frequency (RoCoF) during the disturbance and false activation of protective devices. There is a need to assess the inertia over the past decade amidst the evolving landscape of renewable energy sources to develop strategies for integrating energy storage, enhancing resilience measures, and ensuring the stable and reliable operation of the grid. Therefore, a realistic assessment of the inertia trend using a measurement-based approach that addresses the limitations of existing models is proposed. An inertia study of the Western Interconnection in the United States is performed utilizing the data from 2013 to 2022, obtained from FNET/ GridEye network. The three-second RoCoF time window is chosen for the study as it showed an optimum balance between a strong correlation with the power imbalance (ΔP) and minimum inclusion of primary response from governor. The obtained inertia trend result shows a small percentage declination of inertia over the decade. By examining the result alongside a generation mix graph, insights are gained into the dynamic interplay between shifting energy landscape and system inertia.

Dulal, Saurav↗

Bulb-style Kaplan Turbine - Run-of-the-river (ror) Hydro Governor And Turbine Model

This software package includes hydro governor and turbine models developed in Simulink (Mathworks Inc.) and RSCAD (RTDS Technologies) for low-head bulb-style Kaplan turbine hydropower plants. The model developed in Simulink has been designed and tuned to match the governor-turbine response for a real-world hydropower unit owned by Idaho Falls Power (IFP). The Simulink and RSCAD models enable real-time testing in a hardware-in-the-loop (HIL) implementation using OPAL-RT and RTDS digital real-time simulators, respectively. An automatic initialization for dynamic simulation has also been integrated to each model in both Simulink and RSCAD. The RSCAD initialization involves a novel python-based interfacing for automatic modification of the initial conditions in the model. The parameters of these models can be tuned to match other hydropower plants in this class.

Alam, SMShafiul↗

A Unified Analytical Method to Quantify Three Types of Fast Frequency Response from Inverter-Based Resources

With more inverter-based resources (IBRs), our power systems have lower frequency nadirs following N-1 contingencies, and undesired under-frequency load shedding (UFLS) can occur. To address this challenge, IBRs can be programmed to provide at least three types of fast frequency response (FFR), e.g., step response, proportional response (P/f droop response), and derivative response (synthetic inertia). However, these heterogeneous FFR challenge the study of power system frequency dynamics. Thus, this paper develops an analytical frequency nadir prediction method that allows for the consideration of all three potential forms of FFR provided by IBRs. The proposed method provides fast and accurate frequency nadir estimation after N-1 generation tripping contingencies. Our method is grounded on the closed-form solution for the frequency nadir, which is solved from the second-order system frequency response model considering the governor dynamics and three types of FFR. The simulation results in the IEEE 39-bus system with different types of FFR demonstrate that the proposed method provides an accurate and fast prediction of the frequency nadir under various disturbances.

fast frequency response↗

Frequency Control and Dynamics (Part 1) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Control and Dynamics (Part 2) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Reference Governor for Plasma-Shape Control in Tokamaks

Tokamaks are torus-shaped devices where a high-temperature, ionized gas (i.e. a plasma) is confined by means of helical magnetic fields. The ultimate goal of tokamaks is producing net electrical energy by means of nuclear-fusion reactions within the plasma. The shape of the plasma inside the tokamak is closely related with its confinement characteristics and, therefore, with the produced fusion power. In order to achieve and maintain plasma shapes that maximize the fusion yield, feedback controllers have been successfully developed during the years. However, machine-protection and plasma-stability requirements impose hard constraints on the plasma-shape targets that can be safely achieved by a feedback controller. In this work, a reference governor is proposed to provide, in real time, plasma-shape targets that fulfill the aforementioned safety requirements. The reference governor calculates such plasma-shape targets in response to changes in the state of the closed-loop system, as well as disturbances in the plasma energy and current. Here, the reference-governor design is based on a dynamical model of the plasma electromagnetic response. Simulation tests of the reference governor have been carried out for different plasma scenarios in the DIII-D tokamak to emulate realistic cases where safety may be compromised.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The design of a turboshaft speed governor using modern control techniques

The objectives of this program were: to verify the model of off schedule compressor variable geometry in the T700 turboshaft engine nonlinear model; to evaluate the use of the pseudo-random binary noise (PRBN) technique for obtaining engine frequency response data; and to design a high performance power turbine speed governor using modern control methods. Reduction of T700 engine test data generated at NASA-Lewis indicated that the off schedule variable geometry effects were accurate as modeled. Analysis also showed that the PRBN technique combined with the maximum likelihood model identification method produced a Bode frequency response that was as accurate as the response obtained from standard sinewave testing methods. The frequency response verified the accuracy of linear models consisting of engine partial derivatives and used for design. A power turbine governor was designed using the Linear Quadratic Regulator (LQR) method of full state feedback control. A Kalman filter observer was used to estimate helicopter main rotor blade velocity. Compared to the baseline T700 power turbine speed governor, the LQR governor reduced droop up to 25 percent for a 490 shaft horsepower transient in 0.1 sec simulating a wind gust, and up to 85 percent for a 700 shaft horsepower transient in 0.5 sec simulating a large collective pitch angle transient.

Delosreyes, G.↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Measured effects of wind turbine generation at the Block Island Power Company

Data measurements made on the NASA MOD-OA 200-kw wind-turbine generator (WTG) installed on a utility grid form the basis for an overall performance analysis. Fuel displacement/-savings, dynamic interactions, and WTG excitation (reactive-power) control effects are studied. Continuous recording of a large number of electrical and mechanical variables on FM magnetic tape permit evaluation and correlation of phenomena over a bandwidth of at least 20 Hz. Because the wind-power penetration reached peaks of 60 percent, the impact of wind fluctuation and wind-turbine/diesel-utility interaction is evaluated in a worst-case scenario. The speed-governor dynamics of the diesel units exhibited an underdamped response, and the utility operation procedures were not altered to optimize overall WTG/utility performance. Primary findings over the data collection period are: a calculated 6.7-percent reduction in fuel consumption while generating 11 percent of the total electrical energy; acceptable system voltage and frequency fluctuations with WTG connected; and applicability of WTG excitation schemes using voltage, power, or VARS as the controlled variable.

Wilreker, V. F.↗

Emergency Communications Console

NASA has applied its communications equipment expertise to development of a communications console that provides, in a compact package only slightly larger than an electric typewriter, all the emergency medical services communications functions needed for a regional hospital. A prototype unit, built by Johnson Space Center, has been installed in the Odessa (Texas) Medical Center Hospital. The hospital is the medical control center for the 17-county Permian Basin Emergency Medical System in west Texas. The console project originated in response to a request to NASA from the Texas governor's office, which sought a better way of providing emergency medical care in rural areas. Because ambulance travel time is frequently long in remote areas of west Texas, it is important that treatment begin at the scene of the emergency rather than at the hospital emergency room. A radio and telephone system linking ambulance emergency technicians and hospital staff makes this possible. But earlier equipment was complex, requiring specialized operators. A highly reliable system was needed to minimize breakdowns and provide controls of utmost simplicity, so that the system could be operated by physicians and nurses rather than by communications specialists. The resulting console has both radio and telephone sections. With the radio equipment, hospital personnel can communicate with ambulance drivers and paramedics, receive incoming electrocardiagrams, consult with other hospitals, page hospital staff and set up a radio-to-telephone "patch." The telephone portion of the system includes a hotline from the Permian Basin Emergency Medical Service's resource control center, an automatic dialer for contacting special care facilities in the Permian Basin network, a hospital intercom terminal and a means of relaying cardioscope displays and other data between hospitals. The integrated system also provides links with local disaster and civil defense organizations and with emergency "Dial 911" control points.

Source record↗

Mitigating the Effect of Wind Gusts on Local Run-of-River Hydropower Plants Using Cooperative Control

This paper focuses on the challenges and solutions associated with the integration of wind farms in a hydro- dominated power system. Due to sudden increases in wind power, the system frequency can increase, causing excessive reduction in the run-of-river (ROR) system’s power. Considering their small pondage, this can result in damage to the physical structure due to water level violations which are also penalized by stakeholders. To prevent excessive ROR power deviations, ROR governor wear and tear, and to prevent tie-line deviations, a centralized, distributed, and hybrid scheme for coordinating the response from a cluster of ROR plants is examined. Both centralized and distributed control as well as their hybrids can reduce frequency peaks. However, the inclusion of decentralized cooperative controls leads to reduced governor actions from fast- acting plants while enhancing net response from the hydro unit cluster.

13 HYDRO ENERGY↗

Generator Frequency Response Droop Monitoring Tool

Monitoring and analyzing the frequency response performance of power generation units is essential for maintaining reliable and secure power system operation. To address this need, an automation tool has been developed to provide a pipeline for processing historical power plant generation data, including large-scale SCADA archives. The tool performs end-to-end processing, including event detection, frequency response (FR) analysis in accordance with NERC standards, and estimation of speed governor droop characteristics. The tool is designed with a modular architecture, allowing individual components of the workflow to be extended, customized, or deployed independently. In addition, the tool provides an API that enables seamless integration with other production systems and operational analytics platforms.

Etingov, PavelV [Pacific Northwest National Labora↗

Identification of a STOL propulsion plant model from flight data

Accurate dynamic models for propulsion system behavior are critical to successful synthesis of STOL autothrottle/autoland control systems. This paper describes the development of a nonlinear dynamic model for the response of a STOL aircraft in the landing/approach configuration. The model is based upon an analysis of the throttle, governor, and turbofan engine components. Model parameters are directly identified from data acquired during a flight of the NASA Augmentor Wing Jet STOL research aircraft. The accuracy of the model and a comparison of results for two engines are described. Various approaches to modeling propulsion system response for complex systems representative of current and near-term aircraft are discussed.

De Hoff, R. L.↗

Control Co-Design Framework for Joint Optimization of PID Governor and Hydraulic Dynamics for a Hydropower Plant

This paper presents a control co-design (CCD) framework tailored to the hydraulic and mechanical subsystems of hydropower systems, aimed at enhancing their dynamic performance and responsiveness to grid demands. Conventional sequential design approaches often fall short in capturing the coupled interactions between plant dynamics and control objectives. The proposed CCD methodology enables simultaneous optimization of key hydro plant parameters - such as governor settings, penstock characteristics, and valve control - with the control system architecture. Results indicate that both CCD and sequential design approaches achieve comparable transient and steady-state performance, with minor discrepancies arising from differences in their optimized parameters. However, CCD demonstrates a distinct advantage by tripling the water time constant (Tw) while maintaining similar dynamic performance to the sequential approach. This increase in Tw enables optimization of penstock dimensions, as it is directly influenced by penstock design, thereby contributing to overall cost optimization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables: Preprint

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds after disturbance. To address this challenge, this paper proposes a frequency stability unit commitment constraint considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Thus, this paper first analyzes a frequency nadir differential equation that considers SG governor model and three kinds of FFR provided by IBRs. A system frequency nadir estimation framework is developed with consideration of various conventional SG and IBR models. The accuracy of this frequency estimation framework is validated by largest N-1 contingency simulation result of a real island system. Then, the adaptive inertia frequency stability unit commitment constraint is derived from sensitivity analysis method. Finally, we demonstrate the effectiveness of our developed constraints with one year day-ahead unit commitment results of the real island system.

fast frequency response↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗