Search NASA⌕ Search

SEARCH · Search NASA

Results for “gridlines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Residual Stress Limits Gridline Bridging in Cracked Solar Cells

Cracks in solar cells can be generated in various ways, but this does not mean immediate power loss. Previous studies showed that gridlines bridge cracked silicon cells, and the bridging behavior decreases during the contact and separation of gridlines within bare cells. In this study, we investigate bridging behavior in laminated monocrystalline cells. We characterize the behavior with Weibull analysis of critical crack opening distance (COD), at which the gridline is completely separated. The Weibull analysis of the laminated cell shows a good agreement with bare cells at the first cycle. However, we observe different behavior during cyclic bending. Bare cells show gradual decay of critical COD, while laminated cells show instant decay and plateau. We hypothesize that the difference is due to residual stress, squeezing gridlines, and causing plastic deformation. This is justified by the correlation between critical COD and gridline morphology. In the presentation, we shall present a Weibull analysis of the cyclic bending of a laminated cell with a reduced residual stress effect.

bending↗

Cracked Gridline Wear Out Follows a Power Law

Cracks can form in Silicon solar cells in photovoltaic modules due to mechanical stresses arising from various extrinsic factors like handling and weather. While the immediate performance degradation may be minor, continuous loading overtime will degrade module performance. One probable reason is gridline surface wear across the cracked silicon with increased cyclic loading. In this work we propose a method to correlate gridline wear to module electrical degradation. We begin by conducting cyclic four-point bending tests on laminated silicon solar cells with a single crack and 22 intact gridlines for 10,000 cycles. We measure the progressive change in resistance during each loading cycle. We correlate it to a length scale called critical crack opening displacement (CCOD) that signifies failure of individual gridlines. By employing Weibull analysis, we determine the characteristic CCOD for all cycles and fit this data to a modified version of a wear power law. We observe that this i ts the data well. We also propose to study the effect of individual parameters in the power law equation and extend the equation to include material properties.

bending↗

Fatigue-Like Behavior of Silver Metallization Gridlines and Proposed Damage Mechanics Model

In this work, we present a novel method to evaluate the fracture and fatigue-like behavior of crystalline silicon PV cell metallization. Initial results demonstrate that silver metal gridlines are capable of bridging a ~10–20 µm gap prior to becoming electrically open and do demonstrate fatigue-like behavior under cyclic straining conditions. This later phenomenon was well fit with a traditional power law equation for high cycle fatigue and enabled the development of a damage mechanics model for gridline failure.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Optimization of Carbon-Nanotube-Reinforced Composite Gridlines Towards Commercialization

Solar cells in PV modules crack during field operation from environmental stressors, including extreme weather events, such as hailstorms and hurricanes. These cracks can lead to gradual or immediate acute power degradation. To directly address cell-crack-induced degradation, we have formulated a carbon nanotube additive for commercial screen printed silver pastes. We have shown in previous work that these metal matrix composites have little to no effect on the cell’s efficiency while enhancing the metallization’s fracture toughness and electrical gap-bridging capability. In this work, we focus on optimizing the composite metallization to achieve the best possible performance. We discover that reducing carbon nanotube agglomerations in the paste not only improves the printability for narrow gridlines, but also increases the modulus of toughness of the metallization by over 500%.

carbon nanotubes↗

Translating Material-Level Characterization of Carbon-Nanotube-Reinforced Composite Gridlines to Module-Level Degradation

Cell cracks in PV modules caused by poor handling during shipping and installation as well as from extreme weather events can lead to gradual or immediate power degradation. To directly address cell-crack-induced degradation, we have formulated a carbon nanotube additive for commercial screen printed silver pastes. We have shown in previous work that these metal matrix composites have little to no effect on the cell's efficiency while enhancing the metallization's fracture toughness and electrical gap-bridging capability. In this work, we focus on translating materials level characterization techniques to module level degradation. We found that we get conflicting results from two different methods of measuring the metallization's ability to electrically bridge gaps in cracked solar cells. Mini-module stress testing is currently underway to determine which materials characterization correlates well with the min-module degradation characteristics.

carbon nanotubes↗

Understanding interfacial chemistry of positive bias high-voltage degradation in photovoltaic modules

Photovoltaic module degradation from a high system voltage is a prevalent degradation mode in the field, where the enabling degradation mechanisms are inherently dependent on the voltage bias polarity of the installed system. In this study, the effects of positive bias on module performance are confirmed and the underlying chemical degradation processes are more thoroughly investigated to reveal different degradation pathways from those previously reported in negative bias studies. When cells are under +1000 V stress, crystalline silicon mini-modules with poly(ethylene-co-vinyl acetate) (EVA) encapsulant demonstrated a significant photocurrent loss due to EVA discoloration and delamination from increased chemical reactivity at the front-side EVA/cell metallization interface. Brown discoloration of the EVA encapsulant near the cell gridlines is linked to an electrochemical reaction at the Ag gridlines under hot and humid conditions (85 °C, 85% relative humidity). Chemical compositional analysis using X-ray photoelectron spectroscopy (XPS) confirmed that the discoloration is attributed to the formation of silver sulfide (Ag 2 S) and/or silver oxide (Ag 2 O) species at the EVA/Ag gridline interface. The subsequent migration of Ag ions from the cell gridlines into the bulk of the EVA was evident from XPS depth profiling and optical microscopy. However, the Ag signal was not detected at the EVA/glass interface, inferring limited ionic transport through the nominally 0.45 mm thick encapsulant. For the samples studied herein, the sulfur is believed by the process of elimination to come from the ambient air, diffusing into the module through the permeable polymer backsheet.

14 SOLAR ENERGY↗

Solar Cell Metallization Wear is Sensitive to Loading Frequency

Here, we performed cyclic loading of photovoltaic laminates with precracked silicon cells to explore if and how loading frequency and contact pressure influence the ensuing gridline wear-out process. A measurement of parallel resistance across cracked gridlines on a laminated cell coupon was used as the metric for gridline electrical contact degradation. A statistical analysis of variance (ANOVA) analysis of the experimental results discerned that loading frequency is a more significant factor than contact pressure for gridline degradation.

14 SOLAR ENERGY↗

Improvement of screen-printable metallization paste for low-cost silicon solar cells utilizing silver coated copper powders

This aims of this project were to develop low-cost screen-printable Ag|Cu metallization, as alternative to Ag paste, for contacting PERC solar cells with transparent emitter for high performance and reliability. The intended goal was to achieve 81% fill factor with a screen-printable Ag|Cu paste alternative. This was attempted through a three strand approach including Ag|Cu formulation by SVMT, production using cavitation technology by ACI and contact formation through the understanding of (i) the liquid phase sintering of the nano/macro particles of Ag|Cu to achieve bulk metal with very low series resistance, (ii) optimization of contact firing to avoid penetration of Cu into the silicon bulk, and finally (iii) proper analysis to quantify the contributions of each resistance component and keep the total series resistance at 0.2 Ω-cm2, which would result in high fill factor of 81% by UNC Charlotte. The objectives also involved i) the implementation of glass frit with Cu metal that will etch through the ARC for low contact resistance and adhesion, ii) development of Ag|Cu pastes with the optimized glass frit, iii) investigation of the impact of Cu particle size, morphology and loading on the gridline resistance, iv) narrow gridline screen designs along with narrow gridline prints, v) development of fast belt speeds of up to 375 inches per minute (ipm) sintering, and vi) stability study on Ag|Cu contact to high performance and reliability.

14 SOLAR ENERGY↗

Interfacial Characterization of Positive Bias Voltage Degradation in PV Modules

Degradation from high system voltage is a prevailing failure mode in fielded photovoltaic modules, and the degradation mechanism is inherently dependent on the bias polarity. Here we report the effects of positive bias. Modules under positive bias demonstrated a significant photocurrent loss caused by two routes. First, delamination and discoloration of the silicon nitride layer, leading to optical loss determined by reflectance measurements. Second, chemical discoloration of the cell gridlines and encapsulant (EVA), which is linked to an electrochemical reaction at the silver electrodes. Chemical compositional analysis using X-ray photoemission spectroscopy demonstrated that the discoloration is attributed to Ag 2 S and/or Ag 2 O. Evidence of Ag ion migration from the cell grid into the encapsulant is observed after shallow depth profiling on the EVA surface. However, Ag was not detected at the EVA/glass interface, inferring limited Ag ion transport through the EVA. The source of sulfur is believed to be ambient air, which diffused into the module through the breathable backsheet.

characterization↗

Electrochemical mechanisms of leakage‐current in photovoltaic modules

Abstract This paper analyzes the mechanisms and pathways for leakage current flow observed in Si photovoltaic modules subjected to high temperature and humidity and a large voltage bias with respect to ground. The current inside of the frame is in the form of electron motion, but in the glass and polymer, it is in at least a large part attributable to the movement of ions. When the mode of current flow changes from electronic to ionic conduction, electrochemical reactions will take place at the interface. This can include reactions that produce volatile chemical species like H 2 , CO x , and O 2 , along with ionic species such as OH − and H 3 O + . Here, we see evidence of the importance of different charge carriers with different diffusion rates and the influence of electrochemical processes involved. The application of negative voltage to the cell circuit affects the resistivity of glass producing surfaces with poor conductivity but with some increases in the electrochemical potential producing complicated interactions that are important when the voltage is changed. In the polymer, there is the development of a space charge region and a chemical gradient providing two oppositional forces to current flow, which when released create a complicated discharge process. Here, we give a basic understanding of the charge/discharge of PV cells highlighting how the specific mechanisms are important in understanding some of the degradation processes in PV modules. We find that there is evidence of multiple significant charge carrier species with different diffusion time scales. The glass/polymer interface forms a depleted region of higher resistance after prolonged exposure to current. Charge also builds up at the polymer to cell antireflective coating interface and mostly flows to the gridlines to experience electrochemical reactions. These complexities result in non‐linear behavior where the apparent resistivities of the different layers change during charge/discharging processes, making the modeling of the current flow extremely difficult.

14 SOLAR ENERGY↗

Quantifying optical loss of high-voltage degradation modes in photovoltaic modules using spectral analysis

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative (“HV-”) and positive (“HV+”) polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (Si x N y ) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85°C/85% relative humidity included spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the Si x N y coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared with a mini-module previously subjected to HV-/HV+ stress. Here the model suggests that one third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the Si x N y coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Screen printable copper pastes for silicon solar cells

The current work demonstrates the successful metallization of a PERC silicon solar cell with screen-printable copper (Cu) paste that is sintered at elevated temperature in air atmosphere. The existing state of the art in Silicon (Si) solar cell metallization is silver (Ag) paste; Cu cost is 1/100th the cost of Ag and has a comparable conductivity. However, Cu undergoes rapid oxidation at elevated temperatures and the high diffusion of Cu into Si restricts its usage in the metallization of silicon solar cells. In this paper, a Cu paste containing a proprietary mixture of antioxidant additives and diffusion inhibitors was used to make front gridlines on PERC cells. The Cu-printed cells were fired in an IR belt furnace with a peak temperature of 576°C in air atmosphere. The solar cells discussed here reached an efficiency of 19%, which is 88% of the efficiency measured for a commercial Ag-printed cell. The working devices were further characterized using STEM, EDX, ToF-SIMS and long-term suns-V oc studies demonstrating an absence of Cu diffusion. Furthermore, thermally stressing the Cu-printed solar cells yielded a reduction of less than 1.9% of the initial pseudo fill factor (pFF) after 1000 hours at 200°C. Here, the shunt resistance of cells monitored over 3 years remained within 2.5% of its initial value, which demonstrates the effectiveness of the Cu diffusion barrier.

14 SOLAR ENERGY↗

Differences in Printed Contacts Lead to Susceptibility of Silicon Cells to Series Resistance Degradation

Here, in this case study, we investigate a degradation mode occurring at the cell level in fielded multi-Si modules. The modules exhibit a mix of affected and unaffected cells. Affected cells show a progressive, series-resistance-related power degradation as shown via module- and cell-level IV curves, along with electroluminescence (EL) and PL imaging at the module, cell, and cell core sample scales. Scanning electron microscopy and energy-dispersive X-ray spectroscopy reveal a difference in the oxides in the silver paste used in screen printing of the gridline contacts. The paste in the affected cells is lead rich, whereas the paste in the unaffected cells is zinc rich. This suggests that the cells were screen printed with different silver paste compositions and possibly firing conditions, and that the different composition correlates with the susceptibility to degradation. Our results indicate degradation of the contact at the oxide-silver interface, causing a severe increase in series resistance across the cell that continues to progress over time.

14 SOLAR ENERGY↗

Degradation of Monocrystalline Silicon Photovoltaic Modules From a 10-Year-Old Rooftop System in Florida

A system of 180 monocrystalline aluminum back-surface field modules were installed in Cocoa, Florida, for 10 years. In total, 156 modules are characterized and compared to 3 controls. Power degradation rates vary between – 0.14% to – 3.22% per year, with median and average rates of –0.92% and –1.05% per year, respectively. The losses are primarily resistive with minor optical and recombination loss contributions. Electroluminescence imaging shows a characteristic pattern, which is shown to be resistive in nature when compared to photoluminescence. Resistive losses are due to corrosion of the rear contact Ag/solder interface and, to a much lesser degree, gridline Ag oxidation. Moisture ingress through the backsheet is likely responsible for mediating corrosion. Optical losses are due mostly to a combination of antireflection coating degradation, minor encapsulant browning, and delamination. Minor front contact corrosion may contribute to recombination. Furthermore, this study expands upon previous work on this vintage of the module by examining a large sample set, comprehensive characterization including techniques not previously used on these modules, and a comparison between two other systems of different climates.

14 SOLAR ENERGY↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Employing Fracture Statistics to Track Cell Reliability Through Module Fabrication

In this work we demonstrate how fracture statistics may be employed to track cell reliability through module fabrication steps. We were able to detect how cell cutting equipment could reduce cell fracture strain by 25 % as well as increase its variability. A smaller reduction was found to result from the ribbon soldering operation, and all cells measured were weaker when strained in an orientation perpendicular to the gridlines. Cell fracture measurements were found to be consistent with the number of cracked cells experienced in full sized modules exposed to mechanical loading. A structural mechanics model was created to elucidate how the requisite fracture strain is developed in a cell encapsulated within a PV module and demonstrates that this strain decreases more than 50 % from its center to edge when placed within the inner loading span of four-point flexure. The associated implications on the apparent cell strength is examined with an effective volume treatment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Self-Sustained CPS Design for Reliable Wildfire Monitoring

Continuous monitoring of areas nearby the electric grid is critical for preventing and early detection of devastating wildfires. Existing wildfire monitoring systems are intermittent and oblivious to local ambient risk factors, resulting in poor wildfire awareness. Ambient sensor suites deployed near the gridlines can increase the monitoring granularity and detection accuracy. However, these sensors must address two challenging and competing objectives at the same time. First, they must remain powered for years without manual maintenance due to their remote locations. Second, they must provide and transmit reliable information if and when a wildfire starts. The first objective requires aggressive energy savings and ambient energy harvesting, while the second requires continuous operation of a range of sensors. To the best of our knowledge, this paper presents the first self-sustained cyber-physical system that dynamically co-optimizes the wildfire detection accuracy and active time of sensors. The proposed approach employs reinforcement learning to train a policy that controls the sensor operations as a function of the environment (i.e., current sensor readings), harvested energy, and battery level. Here, the proposed cyber-physical system is evaluated extensively using real-life temperature, wind, and solar energy harvesting datasets and an open-source wildfire simulator. In long-term (5 years) evaluations, the proposed framework achieves 89% uptime, which is 46% higher than a carefully tuned heuristic approach. At the same time, it averages a 2-minute initial response time, which is at least 2.5× faster than the same heuristic approach. Furthermore, the policy network consumes 0.6 mJ per day on the TI CC2652R microcontroller using TensorFlow Lite for Micro, which is negligible compared to the daily sensor suite energy consumption.

54 ENVIRONMENTAL SCIENCES↗