Search NASA⌕ Search

SEARCH · Search NASA

Results for “hard X-ray imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

Multiscale and multidimensional modeling of particle acceleration and transport in solar flares

Multi-messenger, multi-viewpoint, and time-resolved observations of solar flares are now providing unprecedented constraints on particle acceleration sites, energy conversion, and energy transport. The interpretation of current observations, including microwave imaging spectroscopy from EOVSA, hard x-ray (HXR) imaging from Solar Orbiter/STIX, gamma-ray diagnostics from Fermi, and in situ measurements from Parker Solar Probe and Solar Orbiter, collectively demands modeling frameworks that go beyond traditional spatially unresolved, one-zone models or single-mechanism descriptions. This review surveys multiscale and multidimensional modeling approaches, including kinetic, magnetohydrodynamic (MHD), and macroscopic particle models, that are being developed to meet the need. Kinetic simulations reveal that three-dimensional (3D) effects, including field-line chaos and self-generated turbulence, are essential for sustained power-law particle acceleration. MHD simulations now capture flux-rope eruptions, plasmoid-unstable current sheets, and turbulent flare regions in realistic magnetic topologies. Macroscopic models coupling MHD with energetic-particle models produce spatially resolved electron distributions and synthetic HXR and microwave emissions for direct comparison with observations. Despite these advances, outstanding challenges remain in bridging kinetic and global scales, improving MHD simulations and macroscopic particle models, and achieving quantitative model-observation closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous hard x-ray Talbot phase and dark-field imaging in laser experiments at XFEL facilities

X-ray Free Electron Laser (XFEL) facilities offer unprecedented opportunities to advance instrumentation for studying matter under extreme conditions. In this study, we harnessed the enhanced x-ray capabilities of XFELs to demonstrate dark field imaging in laser-driven experiments at XFEL facilities. Utilizing a Talbot x-ray interferometer, we simultaneously captured transmission, dark-field, and differential phase contrast radiographs of laser-driven metallic foils. Our work showcases the feasibility of single-shot grating-based Talbot x-ray dark-field imaging in pump-probe experiments at XFEL facilities, opening doors to a wide range of hard x-ray imaging applications in material science and high-energy density physics.

Bouffetier, V. [Helmholtz-Zentrum Dresden-Rossendo↗

Imaging Valence Electron Rearrangement in a Chemical Reaction Using Hard X-Ray Scattering

We have observed the signatures of valence electron rearrangement in photoexcited ammonia using ultrafast hard x-ray scattering. Time-resolved x-ray scattering is a powerful tool for imaging structural dynamics in molecules because of the strong scattering from the core electrons localized near each nucleus. Such core-electron contributions generally dominate the differential scattering signal, masking any signatures of rearrangement in the chemically important valence electrons. Ammonia represents an exception to the typically high core-to-valence electron ratio. Here, we measured 9.8 keV x-ray scattering from gas-phase deuterated ammonia following photoexcitation via a 200 nm pump pulse to the 3s Rydberg state. We observed changes in the recorded scattering patterns due to the initial photoexcitation and subsequent deuterium dissociation. Ab initio calculations confirm that the observed signal is sensitive to the rearrangement of the single photoexcited valence electron as well as the interplay between adiabatic and nonadiabatic dissociation channels. The use of ultrafast hard x-ray scattering to image the structural rearrangement of single valence electrons constitutes an important advance in tracking valence electronic structure in photoexcited atoms and molecules.

Gabalski, Ian [SLAC National Accelerator Laborator↗

Development of a broadband hard x-ray radiography platform for pulsed-power experiments

In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution bandpass x-ray imaging with crystal reflectors: Overcoming geometric aberrations

The imaging problem of a specular reflector is revisited. Retaining terms through the second order in the reflector surface expansion, we derive the form of the aberration-limiting aperture for arbitrary magnification, assuming no bandwidth limitations. A permissible relative aperture size of the reflector is limited by a set relative aberration tolerance and scales with the tangent of the central glancing angle of incidence. These limiting aberrations become practically insignificant near backscattering. The results extend to x-ray diffracting crystals in symmetric Bragg geometry shaped as an ellipsoid of revolution. This geometry permits polychromatic imaging for hard x-rays over a bandwidth defined by the accepted range of Bragg angles, thereby suppressing aberrations of higher orders. We assess ellipsoidal crystal imagers using ray tracing simulations for two high-magnification designs with Bragg angles far from and close to backscattering. Finally, in both cases, the ellipsoidal crystals produce images of higher quality compared to those formed by equivalent toroidal crystal imagers.

Bragg reflection↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

Pair Cascades in Magnetar Magnetospheres

Resonant inverse Compton scattering (RICS) of soft thermal photons by relativistic particles on closed magnetic field loops has been proposed to explain the hard emission observed up to and beyond 200 keV from magnetars. If particles injected at the base of the loops have Lorentz factors ≳10 2 , the RICS spectra will be attenuated by both one-photon pair production and photon splitting in the ultrastrong magnetar fields, producing additional spectral components from pair synchrotron radiation and split photons that produce further generations of pairs and split photons. We investigate such cascades initiated by the primary injected electrons through a Monte Carlo simulation, and study the cascade spectra and pair distributions. For most observer angles, the pair synchrotron and split-photon spectra dominate the RICS primary spectra and produce complex polarization signals. In particular, the synchrotron spectra are highly polarized with degree 40%–80%, are softer than the RICS spectra, and may account for the high polarization of some magnetar spectra observed by the Imaging X-ray Polarimetry Explorer above 3 keV.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography

We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.

36 MATERIALS SCIENCE↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Role of Si substitution in modulating the coercivity and magnetic anisotropy in Fe3CoB2 nanocrystallites

In this work, we report the impact of Si substitution on the structural and magnetic properties of Fe3CoB2 nanocrystallites as a rare-earth-free hard-magnet candidate. X-ray diffraction confirmed the formation of the tetragonal phase with an average crystallite size of ∼40 nm, while the transmission electron microscopy image revealed nanosized crystallites embedded in an amorphous matrix. Room-temperature Mössbauer spectra exhibited two sextets and two doublets, indicating magnetically ordered Fe sites in the tetragonal phase along with high-spin paramagnetic FeIII species in disordered regions. ZFC–FC magnetization curves displayed field-dependent blocking behavior, consistent with paramagnetic Fe species. Singular point detection measurements revealed a high anisotropy field of ∼10.7 kOe in the pristine Fe3CoB2, and systematically decreased with Si substitution. Magnetization measurements revealed a monotonic decrease in saturation magnetization with Si content, while coercivity was observed to increase, likely due to microstructural refinement. These results establish Fe3CoB2 as a rare-earth-free material with strong magnetic anisotropy, ideal for hard magnets.

Abbas, Hur [Department of Physics, University of T↗

Dose Measurement and Monte Carlo FLUKA simulations for the FE and FOE of the 27-ID HEX Beamline

The 27-ID High Energy Engineering X-ray Scattering (HEX) beamline, commissioned in 2024, operates within the Hard X-ray Scattering and Spectroscopy program at Brookhaven Lab’s National Synchrotron Light Source II (NSLS-II). The high energy spectrum at the HEX beamline extends up to several hundred keV, making it well suited for applications such as imaging large engineering samples, including fully assembled batteries, fuel cells, etc.

43 PARTICLE ACCELERATORS↗

Real-space imaging of the electron-pair density hole in molecular Auger–Meitner decay

Electrons in matter can rearrange extremely quickly under external perturbations, underpinning subsequent structural and chemical transformations. Coulomb interactions between neighbouring electrons often shape this response, giving rise to correlated motion and strongly affecting the distribution of electrons in the system. Here we show that non-resonant hard X-ray scattering can directly access changes in the radial electron-pair density during the rapid rearrangement of core and valence electrons. We do this by studying sulfur hexafluoride molecules undergoing Auger–Meitner decay. We exploit a second-order interaction between the X-ray photons and the molecules to trigger and probe the decay dynamics with a single pulse, capturing the electron loss and redistribution before the molecules dissociate. The experiment shows that changes in electron-pair densities can be isolated and measured on ultrafast timescales, providing insight into the real-space evolution of highly excited and short-lived electronic states.

Simmermacher, Mats [University of Oxford (United K↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗

Demonstration of full-scale spatiotemporal diagnostics of solid-density plasmas driven by an ultra-short relativistic laser pulse using an X-ray free-electron laser

Understanding the complex plasma dynamics in ultra-intense relativistic laser–solid interactions is of fundamental importance for applications of laser–plasma-based particle accelerators, the creation of high-energy-density matter, understanding planetary science, and laser-driven fusion energy. However, experimental efforts in this regime have been limited by the lack of accessibility of over-critical densities and the poor spatiotemporal resolution of conventional diagnostics. Over the last decade, the advent of femtosecond brilliant hard X-ray free-electron lasers (XFELs) has opened new horizons to overcome these limitations. Here, for the first time, we present full-scale spatiotemporal measurements of solid-density plasma dynamics, including preplasma generation with tens of nanometer scale length driven by the leading edge of a relativistic laser pulse, ultrafast heating and ionization at the main pulse arrival, the laser-driven blast wave, and transient surface return current-induced compression dynamics up to hundreds of picoseconds after interaction. These observations are enabled by utilizing a novel combination of advanced X-ray diagnostics including small-angle X-ray scattering, resonant X-ray emission spectroscopy, and propagation-based X-ray phase-contrast imaging simultaneously at the European XFEL-HED beamline station.

Huang, Lingen [Helmholtz-Zentrum Dresden-Rossendor↗

Ultrafast x-ray imaging of coherently controlled molecular dynamics in real space and time

Coherent control aims to manipulate chemical processes on the latent length and timescales of atoms and bonds, scales that are intrinsic to molecular dynamics but not directly resolved by most experimental probes. As a result, existing coherent-control experiments, which overwhelmingly rely on spectroscopic observables, leave a crucial blind spot: the direct, real-space recovery of all atomic and molecular rearrangements in response to coherently controlled excitations. Here, we overcome this limitation by integrating a Tannor-Kosloff-Rice pump-control-probe scheme with ultrafast X-ray scattering to capture snapshots of the wavepacket motion in a benchmark molecular system. We demonstrate this by photoexciting diatomic iodine vapor with a visible pump pulse, selectively steering the wavepacket toward ground-state recombination or dissociative pathways with a time-delayed near-IR control pulse, and recording the dynamics with angstrom and femtosecond precision with an ultrashort hard X-ray probe pulse. By comparing these structural observations with numerical solutions of the time-dependent Schrödinger equation, we reveal how coherent control actively reshapes the molecular charge density distribution. Our results pave the way for leveraging structural feedback as a control handle and provide a fundamental microscopic visualization of quantum decoherence and energy redistribution at the atomic level.

Hopper, Thomas R. [SLAC National Accelerator Labor↗