Search NASA⌕ Search

SEARCH · Search NASA

Results for “high bandwidth signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of diamond-based diagnostics for next-generation XFELs

The composition and performance of three different diamond sensor based pass-through diagnostics are presented. A position-sensitive quadrant sensor was designed and characterized using the XPP beam at the SLAC LCLS, demonstrating a generated-charge resolution of 0.025 pC and a position sensitivity of 2 μm, measurable pulse-by-pulse at a repetition rate of up to 50 MHz. A compact signal path capable of repetition rates up to 1 GHz was used to characterize the charge collection properties of diamond sensors as a function of the density of electron-hole pairs created within the sensor, finding a limit of approximately 10 16 electron-hole pairs per cm 3 beyond which the collection efficiency and time began to degrade. Finally, a proposed scheme for measuring ionizing radiation at multi-GHz rates is presented, along with results preliminarily demonstrating signal transport capability in excess of 5 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining quantum noise reduction resources: A practical approach

Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. Here, we demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.

Optomechanics↗

Plasmonics-enhanced photoconductive terahertz detector pumped by Ytterbium-doped fiber laser

We present a photoconductive terahertz detector operating at the 1 µm wavelength range at which high-power and compact Ytterbium-doped femtosecond fiber lasers are available. The detector utilizes an array of plasmonic nanoantennas to provide sub-picosecond transit time for the majority of photo-generated carriers to enable high-sensitivity terahertz detection without using a short-carrier-lifetime substrate. By using a high-mobility semiconductor substrate and preventing photocarrier recombination, the presented detector offers significantly higher sensitivity levels compared with previously demonstrated broadband photoconductive terahertz detectors operating at the 1 µm wavelength range. We demonstrate pulsed terahertz detection over a 4 THz bandwidth with a record-high signal-to-noise ratio of 95 dB at an average terahertz radiation power of 6.8 µW, when using an optical pump power of 30 mW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passband Signal Detection at the Edge

Algorithms for radio frequency (RF) spectrum awareness need to be compatible with edge hardware to be practical for many applications. We developed a signal detection and classification model for the ZCU111 RF System-on-a-Chip (RFSoC) that operates on the fast Fourier transform of passband RF data. The system can detect and classify multiple signals of interest and display the predictions in real-time. The model consists of a modified ConvNeXt backbone and YOLOv3 head to operate on the Deep Learning Processing Unit on the RFSoC. We gathered datasets for training and testing by using a software defined radio to transmit example signals of Wi-Fi 802.11 b/g, Wi-Fi 802.11 n, FM Radio, LTE and LTE-M. By leveraging multiple inputs on the RFSoC frontend, the datasets span up to 4 GHz of bandwidth. The models showed high performance in classification accuracy, center frequency error, bandwidth error, and detection accuracy for both single and multi-signal datasets.

42 ENGINEERING↗

High-sensitivity telecommunication-compatible photoconductive terahertz detection through carrier transit time reduction

We present a telecommunication-compatible photoconductive terahertz detector realized without using any short-carrier-lifetime photoconductor. By utilizing plasmonic contact electrodes on a thin layer of high-mobility photoconductor, the presented detector offers a short transit time for the majority of the photocarriers in the absence of a short-carrier-lifetime photoconductor. Consequently, high-sensitivity terahertz detection is achieved with a record-high signal-to-noise ratio of 122 dB over a 3.6 THz bandwidth under an optical probe power of 10 mW. To achieve such a high sensitivity, the device geometry is chosen to maintain a high resistance and low Johnson Nyquist noise. This design approach can be widely applied for terahertz detection using various semiconductors and optical wavelengths, without being limited by the availability of short-carrier-lifetime photoconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radioimaging for real-time tracking of high-voltage breakdown

Development of a radioimaging diagnostic for high-voltage component reliability testing and electrical breakdown computational model validation is described. Radioimaging has its roots in radio astronomy, where aperture synthesis (also known as synthesis imaging) has been utilized for decades to image radio sources far from Earth. Radioimaging as described herein, in contrast, seeks to image radio sources in close proximity to its receivers (i.e., in a laboratory environment). Here it is shown that corona discharge, a non-destructive precursor to catastrophic (thermal) arc discharge, electromagnetically radiates strongly within a 250 kHz – 2.5 GHz bandwidth, and is readily detected and located by postprocessing the received radio signals. The ability of radioimaging to detect both corona and arc discharge (grouped together herein as high voltage breakdown or HVB) makes it a valuable tool for 100% HVB detection in materials, components, and devices, and has the ability to indicate electrical weakness (via corona detection) prior to a destructive arc discharge event. Radioimaging enables HVB to be located both internal and external to dielectric components under test in near-real-time, with multiple and/or extended HVB events located simultaneously. In contrast, existing non-destructive diagnostics (at the time of this writing) either indicate electrical breakdown without resolving failure locations (e.g., current, voltage, and chemical measurements), locate external HVB (e.g., high-speed optical and ultraviolet (UV) measurements or photography), or locate both external and internal HVB but with low fidelity (e.g., a single HVB source can be located by existing time-of-arrival (TOA) UHF or acoustic emissions). Radioimaging instead creates a sequence of high-fidelity images similar to an optical high-speed camera but at radiofrequencies (RF), and is not limited to two-dimensions. Moreover, radioimaging has already served one internal and two external industry customers, the results of which are detailed in this report. The radioimaging results described herein were part of a three-year effort funded by the Sandia Lab Directed Research and Development (LDRD) program within the Radiation, Electromagnetic, High Energy Density Science (REHEDS) investment area.

47 OTHER INSTRUMENTATION↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

Broadband coplanar-waveguide-based impedance-transformed Josephson parametric amplifier

Quantum-limited Josephson parametric amplifiers play a pivotal role in advancing the field of circuit quantum electrodynamics by enabling the fast and high-fidelity measurement of weak microwave signals. Therefore, it is necessary to develop robust parametric amplifiers with low noise, broad bandwidth, and reduced design complexity for microwave detection. However, current broadband parametric amplifiers either have degraded noise performance or rely on complex designs. Here, we present a device based on the broadband impedance-transformed Josephson parametric amplifier that integrates a hornlike coplanar waveguide transmission line, which significantly decreases the design and fabrication complexity while keeping comparable performance. The device shows an instantaneous bandwidth of 700 (200) MHz for 15 (20) dB gain with an average input saturation power of − 110 dBm and near quantum-limited added noise. The operating frequency can be tuned over 1.4 GHz using an external flux bias. We further demonstrate the negligible backaction from our device on a transmon qubit. The amplification performance and simplicity of our device promise its wide adaptation in quantum metrology, quantum communication, and quantum information processing. Published by the American Physical Society 2024

Qing, Bingcheng (ORCID:0000000345227017)↗

Reflective metasurfaces for broadband terahertz linear-to-circular polarization conversion and circular dichroism spectroscopy

Metasurface polarization convertors permit conversion of an input linear polarization to right- or left-handed circular polarization based on the orientation of the input linear polarization, over a broad bandwidth and with high efficiency. The reflected circular polarizations can be used to evaluate samples for circular dichroism. A THz time-domain detection provides a time domain terahertz signal that is Fourier transformed to produce a THz circular dichroism spectrum.

Chen, Hou-Tong↗

Continuous automatic polarization channel stabilization from heterodyne detection of coexisting dim reference signals

Quantum networking continues to encode information in polarization states due to ease and precision. The variable environmental polarization transformations induced by deployed fiber need correction for deployed quantum networking. Here, we present a method for automatic polarization compensation (APC) and demonstrate its performance on a metropolitan quantum network. Designing an APC involves many design decisions as indicated by the diversity of previous solutions in the literature. Our design leverages heterodyne detection of wavelength-multiplexed dim classical references for continuous high-bandwidth polarization measurements used by newly developed multi-axis (non-)linear control algorithm(s) for complete polarization channel stabilization with no downtime. This enables continuous relatively high-bandwidth correction without significant added noise from classical reference signals. We demonstrate the performance of our APC using a variety of classical and quantum characterizations. Finally, we use C-band and L-band APC versions to demonstrate continuous high-fidelity entanglement distribution on a metropolitan quantum network with an average relative fidelity of 0.94 ± 0.03 for over 30 hrs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THz Radar Observations of Hydrometeors in a Spray Chamber

Abstract A THz radar, with its wide bandwidth, is capable of high‐resolution imaging down to the centimeter scale. In this study, a THz radar is applied to detect hydrometeors generated in a spray chamber. The observed backscattering signals show fluctuations at centimeter scales, indicating various hydrometeor distribution patterns along the radar beam. A co‐located High‐Speed Imaging (HSI) sensor is used to measure the Drop Size Distributions (DSD) in the spray chamber. The radar sampling beam is well aligned with the HSI probes, allowing an objective comparison between the remote sensing and in situ observations. In this study, the observed radar power is compared with the power estimated from the HSI measurements. Results show great consistency, with power difference smaller than 0.5 dB. This study demonstrates the feasibility and great potential of using a THz radar for ultra‐high‐resolution observations of clouds in a laboratory facility, and in the real atmosphere.

54 ENVIRONMENTAL SCIENCES↗

STILGAR End-of-Project Report

The Subsurface Tunnel Imaging LeveraGed by Analysis of Rayleigh wave ellipticity (STILGAR) project demonstrated an integrated geophysical approach for detecting, locating, and characterizing underground structural changes using dense seismic arrays and advanced inversion techniques. Field campaigns were conducted at two operational mines—the Redmond salt mine (Utah) and Graymont Pleasant Gap limestone mine (Pennsylvania)—providing real-world testbeds for monitoring anthropogenic subsurface activity. At the Redmond salt mine, seismic interferometry combined with back-projection inversion successfully identified continuous, low-amplitude signals from mining operations. The approach differentiated stationary from migrating anthropogenic sources, captured daily operational cycles, and validated the potential of passive seismic monitoring for remote detection of underground activity. At the Graymont Pleasant Gap mine, two dense seismic deployments in the spring and fall of 2023 generated over 4 TB of high-resolution data. Key outcomes included the relocation of 199 underground and 8 surface explosions with accuracies within tens of meters and the development of a 3D P-wave velocity model using the triple-difference tomography algorithm (tomoTD) that resolved major structural features such as the mine entrance, low-velocity tunnels, and roof-collapse areas. Ambient noise cross-correlation and back-projection analyses revealed persistent sources linked to ongoing mining activity, whereas horizontal-to-vertical spectral ratio (HVSR) and ellipticity studies confirmed stable site responses across seasons and identified soil thickness trends consistent with regional erosional and depositional processes. Checkerboard and sensitivity tests further validated the robustness of the tomographic results. Overall, the findings emphasize that although significant progress has been made in subsurface imaging, further work is needed to enhance the detection and localization of underground structures. Accurate imaging requires higher frequencies, yet anthropogenic sources tend to dominate the seismic record at those frequencies, and high-frequency surface waves are affected by higher modes that complicate interpretation. The improved detection and localization of human-induced signals enabled detailed temporal and spatial mapping of daily mine operations, demonstrating the feasibility of continuous anthropogenic source monitoring. Sensitivity to signals from nontraditional sources, such as fan operations, highlights the broader applicability of this approach to other industrial environments in which continuous and impulsive signals are present. The field campaigns produced a substantial volume of high-quality seismic data, supporting the development and testing of new methods for seismic source characterization and subsurface imaging. Future deployments should include sensors capable of recording lower frequencies to probe deeper structures, increase bandwidth to enhance resolution and sensitivity to both shallow and deep targets, and collect additional large-scale datasets to refine imaging and source characterization techniques. Moreover, conducting 3D modeling studies of seismic wavefields at higher frequencies will provide a better understanding of wave scattering and cavity–wavefield interactions in complex underground environments. In conclusion, the STILGAR project demonstrated that integrated seismic monitoring can effectively characterize underground operations, capturing both natural and anthropogenic signals. The approaches developed provide a foundation for improved detection, localization, and imaging of subsurface structures and are directly transferable to broader industrial monitoring applications.

58 GEOSCIENCES↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

High Speed Digitizer Firmware (HSD) v1.0

The High Speed Digitizer firmware is an FPGA gateware and embedded firmware that run on evaluation kits (either Xilinx ZCU111 or Xilinx ZCU208 ) that digitizes signals up to 4GSPS and 4GHz analog bandwidth, which can be synchronized to the accelerator timing system, providing synchronous sampling frequency/phase digitization. In addition to these capabilities, a proof of concept for a beam position monitor is also present, providing an envelope detection algorithm capable of determining the transverse beam position for an electron circular accelerator, such as ALS/ALS-U.

Norum, William↗

Towards a self-driving trigger at the LHC: adaptive response in real time

Real-time data filtering and selection—or trigger—systems at high-throughput scientific facilities such as the experiments at the Large Hadron Collider must process extremely high-rate data streams under stringent bandwidth, latency, and storage constraints. Yet these systems are typically designed as static, hand-tuned menus of selection criteria grounded in prior knowledge and simulation. In this work, we further explore the concept of a self-driving trigger, an autonomous data-filtering framework that reallocates resources and adjusts thresholds dynamically in real-time to optimize signal efficiency, rate stability, and computational cost as instrumentation and environmental conditions evolve. We introduce a benchmark ecosystem to emulate realistic collider scenarios and demonstrate real-time optimization of a menu including canonical energy sum triggers as well as modern anomaly-detection algorithms that target non-standard event topologies using machine learning. Using simulated data streams and publicly available collision data from the Compact Muon Solenoid experiment, we demonstrate the capability to dynamically and automatically optimize trigger performance under specific cost objectives without manual retuning. Our adaptive strategy shifts trigger design from static menus with heuristic tuning to intelligent, automated, data-driven control, unlocking greater flexibility and discovery potential in future high-energy physics analyses.

Emami, Shaghayegh [Michigan U.] (ORCID:00090007589↗

Monolithic optoelectronic circuit design for on-chip terahertz applications

We demonstrate a monolithic coplanar stripline platform for on-chip terahertz (THz) generation, transmission, and detection, addressing key challenges of mode purity, bandwidth, and referencing. Capacitive coupling of the photoconductive generator switch enforces pure odd-mode propagation, increases THz field strength, and extends the operational frequency range, achieving 0.05–1.4 THz. Our architecture enables fully monolithic fabrication with amorphous silicon switches, in situ field referencing, and galvanic isolation between generation and detection. Finite-element simulations and experiments confirm that suppressing parasitic modes improves signal integrity, providing a robust platform for high-fidelity THz spectroscopy, ultrafast electronics, and nanoscale quantum materials research.

Capacitive coupling↗