Search NASA⌕ Search

SEARCH · Search NASA

Results for “high throughput sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultra-Fast Laser Fabrication of Alumina Micro-Sample Array and High-Throughput Characterization of Microstructure and Hardness

In the light of recent advances in material informatics, there is a great demand for high-throughput approaches of sample fabrication and property characterization. Currently, no high-throughput approach has been demonstrated for the fast sampling of the microstructure and the correlated properties. In this paper, we demonstrate the ultra-fast fabrication of an alumina sample array and the high-throughput hardness characterization of these sample units. The alumina sample array was fabricated using picosecond (PS) laser micromachining and CO2 laser sintering within a short time (i.e., less than a few minutes). After laser sintering, the hardness of these sample units was characterized using micro-indentation, and the microstructure was observed using scanning electron microscopy (SEM). In each sample unit, the microstructure was uniform for the entire top surface and within about 20 µm depth from the top surface. The relative density (RD) and corresponding micro-hardness of the sample units was found to continuously vary over a wide range from 89% RD with 600 kgf/mm2 hardness to 99% RD with 1609 kgf/mm2 hardness. For these laser-sintered samples, the correlation of hardness and relative density of the alumina matched well with the literature reports on sintered alumina obtained using conventional low-throughput furnace sintering experiments.

36 MATERIALS SCIENCE↗

Modular automated bottom-up proteomic sample preparation for high-throughput applications

Manual proteomic sample preparation methods limit sample throughput and often lead to poor data quality when thousands of samples must be analyzed. Automated liquid handler systems are increasingly used to overcome these issues for many of the sample preparation steps. Here, we detail a step-by-step protocol to prepare samples for bottom-up proteomic analysis for Gram-negative bacterial and fungal cells. The full modular protocol consists of three optimized protocols to: (A) lyse Gram-negative bacteria and fungal cells; (B) quantify the amount of protein extracted; and (C) normalize the amount of protein and set up tryptic digestion. These protocols have been developed to facilitate rapid, low variance sample preparation of hundreds of samples, be easily implemented on widely-available Beckman-Coulter Biomek automated liquid handlers, and allow flexibility for future protocol development. By using this workflow 50 micrograms of protein from 96 samples can be prepared for tryptic digestion in under an hour. We validate these protocols by analyzing 47 Pseudomonas putida and Rhodosporidium toruloides samples and show that this modular workflow provides robust, reproducible proteomic samples for high-throughput applications. The expected results from these protocols are 94 peptide samples from Gram-negative bacterial and fungal cells prepared for bottom-up quantitative proteomic analysis without the need for desalting column cleanup and with protein relative quantity variance (CV%) below 15%.

59 BASIC BIOLOGICAL SCIENCES↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

Understanding Geometry and Microstructure Interactions In LPBF By Linking Lab Scale Studies To Real Part Case Examples

The mechanical properties derived from simple tensile tests are uniquely important in the design and qualification of load bearing metallic components. The tensile properties in standards for wrought metallic materials are generally accessible for design and simulation engineers, but this is not the case for additively manufactured metals. This work investigates the influence of tensile specimen geometry on the mechanical properties of laser powder bed fusion (LPBF) additively manufactured Ti-6Al-4V, particularly in relation to properties measured from specimens excised from an exemplar part. A comprehensive analysis was conducted across various specimen geometries, considering factors such as thermal history, cross-sectional area, shape, and surface roughness. Key findings reveal that sample size, particularly cross-sectional area, significantly affects reported tensile properties, with ASTM E8 flat and round specimens exhibiting differences in elastic modulus (13%), yield strength (17%), ultimate tensile strength (UTS) (14%), and elongation to failure (11%). Additionally, surface roughness was found to have a limited impact on ASTM round geometries, but it becomes critical in thin-walled and small high-throughput samples. The ASTM flat samples closely matched the properties of samples excised from the exemplar part, underscoring the necessity of testing witness samples that accurately represent end-use conditions. Furthermore, mechanical properties of samples built within the stitch zone of the exemplar part demonstrated reduced ductility, highlighting the importance of laser alignment and qualification in multi-laser additive manufacturing processes. Overall, this study emphasizes the need for careful consideration of specimen geometry and testing conditions to ensure accurate reporting of mechanical properties in LPBF Ti-6Al-4V.

36 MATERIALS SCIENCE↗

Machine learning in nuclear materials research

Nuclear materials are often demanded to function for extended time in extreme environments, including high radiation fluxes with associated transmutations, high temperature and temperature gradients, mechanical stresses, and corrosive coolants. They also have a wide range of microstructural and chemical makeups, resulting in multifaceted and often out-of-equilibrium interactions. Machine learning (ML) is increasingly being used to tackle these complex time-dependent interactions and aid researchers in developing models and making predictions, sometimes with better accuracy than traditional modeling that focuses on one or two parameters at a time. Conventional practices of acquiring new experimental data in nuclear materials research are often slow and expensive, limiting the opportunity for data-centric ML, but new methods are changing that paradigm. Here we review high-throughput computational and experimental data approaches, especially robotic experimentation and active learning that is based on Gaussian process and Bayesian optimization. We show ML examples in structural materials (e.g., reactor pressure vessel (RPV) alloys and radiation detecting scintillating materials) and highlight new techniques of high-throughput sample preparation and characterizations, and automated radiation/environmental exposures and real-time online diagnostics. Herein, this review suggests that ML models of material constitutive relations in plasticity, damage, and even electronic and optical responses to radiation are likely to become powerful tools as they develop. Finally, we speculate on how the recent trends of using natural language processing (NLP) to aid the collection and analysis of literature data, interpretable artificial intelligence (AI), and the use of streamlined scripting, database, workflow management, and cloud computing platforms that will soon make the utilization of ML techniques as commonplace as the spreadsheet curve-fitting practices of today.

36 MATERIALS SCIENCE↗

In-Situ SEM High Strain Rate Testing of Large Diameter Micropillars Followed by TEM and EBSD Postmortem Analysis

Background Dislocation dynamic simulations are intended as a tool to understand and predict the mechanical behavior of metallic materials, but its prediction has never been directly verified by experiments due to differences in specimen strain rate and size. Objective In this work, a comprehensive experimental framework is proposed to attempt direct comparison between experiments and discrete dislocation dynamics (DDD) modelling. Methods By integrating high-throughput sample fabrication and a customized testing apparatus, the sample size and strain rate typically employed in DDD simulations are explored experimentally. Constitutive properties such as stress-strain response are measured, and microstructural information is obtained from transmission electron microscopy (TEM) imaging, electron backscatter diffraction (EBSD), and TEM-based orientation mapping. Results Magnesium and copper were selected, as case studies, to demonstrate the newly developed experimental procedure. Measured stress-strain responses for Mg are consistent with those obtained with a miniaturized Hopkison bar experiments. Furthermore, by exploiting the validated workflow, the effect of strain rate on micropillar heterogeneous deformation and associated dislocation plasticity were revealed. Conclusion The work establishes a methodology for the systematic study of not only metals but also other materials and structures at the microscale and high strain rates.

42 ENGINEERING↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-throughput, dynamic, multi-dimensional: an expanding repertoire of plant respiration measurements

A recent burst of technological innovation and adaptation has greatly improved our ability to capture respiration rate data from plant sources. At the tissue level, several independent respiration measurement options are now available, each with distinct advantages and suitability, including high-throughput sampling capacity. These advancements facilitate the inclusion of respiration rate data into large-scale biological studies such as genetic screens, ecological surveys, crop breeding trials, and multi-omics molecular studies. As a result, our understanding of the correlations of respiration with other biological and biochemical measurements is rapidly increasing. Difficult questions persist concerning the interpretation and utilization of respiration data; concepts such as allocation of respiration to growth versus maintenance, the unnecessary or inefficient use of carbon and energy by respiration, and predictions of future respiration rates in response to environmental change are all insufficiently grounded in empirical data. However, we emphasize that new experimental designs involving novel combinations of respiration rate data with other measurements will flesh-out our current theories of respiration. Furthermore, dynamic recordings of respiration rate, which have long been used at the scale of mitochondria, are increasingly being used at larger scales of size and time to reflect processes of cellular signal transduction and physiological response to the environment. Herein, we also highlight how respiratory methods are being better adapted to different plant tissues including roots and seeds, which have been somewhat neglected historically.

59 BASIC BIOLOGICAL SCIENCES↗

Ab initio prediction of an order-disorder transition in Mg 2 Ge O 4 : Implication for the nature of super-Earth's mantles

Here we present an ab initio prediction of an order-disorder transition (ODT) from a I¯42d-type to Th 3 P 4 -type phase in the cation sublattices of Mg 2 GeO 4 , a post-post-perovskite phase. This uncommon type of prediction is achieved by carrying out a high-throughput sampling of atomic configurations in a 56-atom supercell followed by a Boltzmann ensemble statistics calculation. Mg 2 GeO 4 is a low-pressure analog of I¯42d-type Mg 2 SiO 4 , a predicted major planet-forming phase of super-Earths' mantles. Therefore, a similar ODT is anticipated in I¯42d-type Mg 2 SiO 4 as well, which should impact the internal structure and dynamics of these planets. Furthermore, the prediction of this Th 3 P 4 -type phase in Mg 2 GeO 4 further enhances the relationship between the crystal structures of Earth/planet-forming silicates and oxides at extreme pressures and those of rare-earth sesquisulfides at low pressures.

36 MATERIALS SCIENCE↗

Probing the state of hydrogen in δ − AlOOH at mantle conditions with machine learning potential

Hydrous and nominally anhydrous minerals are a fundamental class of solids of enormous significance to geophysics. They are the water carriers in the deep geological water cycle and impact structural, elastic, plastic, and thermodynamic properties and phase relations in Earth's forming aggregates (rocks). They play a critical role in the geochemical and geophysical processes that shape the planet. Their complexity has prevented predictive calculations of their properties, but progress in materials simulations ushered by machine-learning potentials is transforming this state of affairs. Here, we adopt a hybrid approach that combines deep learning potentials (DPs) with the strongly constrained and appropriately normed meta-generalized gradient approximation functional to simulate a prototypical hydrous system. We illustrate the success of this approach to simulate δ − AlOOH ( δ ) , a phase capable of transporting water down to near the core-mantle boundary of the Earth ( ∼ 2900 km depth and ∼ 135 GPa ) in subducting slabs. A high-throughput sampling of phase space using molecular dynamics simulations with DPs sheds light on the hydrogen-bond behavior and proton diffusion at geophysical conditions. These simulations provide a pathway for a deeper understanding of these crucial components that shape Earth's internal state. Published by the American Physical Society 2024

Luo, Chenxing (ORCID:0000000341166851)↗

Studies with the Arapahoe smoke chamber

Samples of polymethyl methacrylate, polyvinyl chloride, polyester, and polystyrene were evaluated using the Arapahoe smoke chamber. These same materials had been previously evaluated using the National Bureau of Standards (NBS) smoke chamber. The percent smoke based on initial weight as determined using the Arapahoe smoke chamber appeared to correlate with the maximum specific optical density under flaming conditions as determined using the NBS smoke chamber. In addition, the percent smoke based on weight loss as determined using the Arapahoe smoke chamber appeared to correlate with the maximum specific optical density under nonflaming conditions as determined using the NBS smoke chamber. The Arapahoe smoke chamber also offers the advantage of high sample throughput and the possibility of related studies of smoke particulates.

Hilado, C. J.↗

Comparison of Classical and Charge Storage Methods for Determining Conductivity of Thin Film Insulators

Conductivity of insulating materials is a key parameter to determine how accumulated charge will distribute across the spacecraft and how rapidly charge imbalance will dissipate. Classical ASTM and IEC methods to measure thin film insulator conductivity apply a constant voltage to two electrodes around the sample and measure the resulting current for tens of minutes. However, conductivity is more appropriately measured for spacecraft charging applications as the "decay" of charge deposited on the surface of an insulator. Charge decay methods expose one side of the insulator in vacuum to sequences of charged particles, light, and plasma, with a metal electrode attached to the other side of the insulator. Data are obtained by capacitive coupling to measure both the resulting voltage on the open surface and emission of electrons from the exposed surface, as well monitoring currents to the electrode. Instrumentation for both classical and charge storage decay methods has been developed and tested at Jet Propulsion Laboratory (JPL) and at Utah State University (USU). Details of the apparatus, test methods and data analysis are given here. The JPL charge storage decay chamber is a first-generation instrument, designed to make detailed measurements on only three to five samples at a time. Because samples must typically be tested for over a month, a second-generation high sample throughput charge storage decay chamber was developed at USU with the capability of testing up to 32 samples simultaneously. Details are provided about the instrumentation to measure surface charge and current; for charge deposition apparatus and control; the sample holders to properly isolate the mounted samples; the sample carousel to rotate samples into place; the control of the sample environment including sample vacuum, ambient gas, and sample temperature; and the computer control and data acquisition systems. Measurements are compared here for a number of thin film insulators using both methods at both facilities. We have found that conductivity determined from charge storage decay methods is 102 to 104 larger than values obtained from classical methods. Another Spacecraft Charging Conference presentation describes more extensive measurements made with these apparatus. This work is supported through funding from the NASA Space Environments and Effects Program and the USU Space Dynamics Laboratory Enabling Technologies Program.

Swaminathan, Prasanna↗

Genomic reconstruction of Bacillus anthracis from complex environmental samples enables high-throughput identification and lineage assignment in Pakistan

Bacillus anthracis, the causative agent of anthrax, is a highly virulent zoonotic pathogen primarily affecting domesticated and wild herbivores. Human exposure to B. anthracis is primarily through contact with infected animals or contaminated animal products. In Pakistan, where livestock vaccines are largely unavailable and infected carcasses are often disposed of improperly, the risk to humans, wildlife and livestock is significant. Currently, the diagnosis of anthrax infections and outbreak tracing necessitates the isolation and culturing of B. anthracis, a process that requires BSL-3 facilities. In this study, we show that positive identification, genome reconstruction and lineage assignment can be accomplished using bioinformatic analysis of DNA extracted directly from environmental samples that would otherwise provide the starting material for isolation and culturing. This approach does not require laboratory target enrichment as is necessary for other pathogens, due in part to the extremely high bacterial load in the bloodstream in the deceased animals. Using these methods, we greatly expand the knowledge of endemic B. anthracis in Pakistan. We provide the first reference B. anthracis genomes from Pakistan since the 1970s and identify A.Br.014 Aust94 as a minor circulating sublineage alongside the dominant A.Br.047 Vollum. Future work will focus on the limits of detection and will determine if this bioinformatic method can be expanded more broadly for B. anthracis or other pathogens to replace typical culture-based methods.

A.Br.047 Vollum↗

High-throughput and high-efficiency sample preparation for single-cell proteomics using a nested nanowell chip

Abstract Global quantification of protein abundances in single cells could provide direct information on cellular phenotypes and complement transcriptomics measurements. However, single-cell proteomics is still immature and confronts many technical challenges. Herein we describe a nested nanoPOTS (N2) chip to improve protein recovery, operation robustness, and processing throughput for isobaric-labeling-based scProteomics workflow. The N2 chip reduces reaction volume to <30 nL and increases capacity to >240 single cells on a single microchip. The tandem mass tag (TMT) pooling step is simplified by adding a microliter droplet on the nested nanowells to combine labeled single-cell samples. In the analysis of ~100 individual cells from three different cell lines, we demonstrate that the N2 chip-based scProteomics platform can robustly quantify ~1500 proteins and reveal membrane protein markers. Our analyses also reveal low protein abundance variations, suggesting the single-cell proteome profiles are highly stable for the cells cultured under identical conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase Diagrams of Alloys and Their Hydrides via On-Lattice Graph Neural Networks and Limited Training Data

Efficient prediction of sampling-intensive thermodynamic properties is needed to evaluate material performance and permit high-throughput materials modeling for a diverse array of technology applications. To alleviate the prohibitive computational expense of high-throughput configurational sampling with density functional theory (DFT), surrogate modeling strategies like cluster expansion are many orders of magnitude more efficient but can be difficult to construct in systems with high compositional complexity. We therefore employ minimal-complexity graph neural network models that accurately predict and can even extrapolate to out-of-train distribution formation energies of DFT-relaxed structures from an ideal (unrelaxed) crystallographic representation. This enables the large-scale sampling necessary for various thermodynamic property predictions that may otherwise be intractable and can be achieved with small training data sets. Two exemplars, optimizing the thermodynamic stability of low-density high-entropy alloys and modulating the plateau pressure of hydrogen in metal alloys, demonstrate the power of this approach, which can be extended to a variety of materials discovery and modeling problems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗