High Speed Data Acquisition for Real Time Feedback in a Light Duty Engine Combustion-Mode Switching Application

The paper describes the integration of a high-speed data acquisition and diagnostics controller used in an advanced engine platform. The controller enables ultra-low emissions and new benchmarks of engine efficiency while running a Gasoline Compression Ignition (GCI) cycle on a 2.2L, 4-cylinder engine. The system enables real-time combustion feedback and vibration analysis in engines. The paper focuses on: (1) the development of an interpolative sampling algorithm for transposition of time acquired data to the crank angle domain using a production crank sensor (60-2 tooth wheel); (2) the control unit, high-speed data acquisition, communication rates between the dedicated data acquisition and base controller to ensure cycle-to-cycle feedback; and, (3) validation exercises using cylinder pressure measurements. Here, the study shows how the algorithm resolves cylinder pressure information over an engine cycle, validating its robustness across acquisition rates of 50 and 200 kHz, with crank angle resolutions of 0.5° and 0.1°. Results show that the 50 kHz, 0.5° hardware yield combustion phasing and torque estimates within 0.1° and 1% torque of those attained with the 200 kHz, 0.1° hardware. Finally, study shows the dedicated controller and communication speeds allow for next-cycle fuel injection correction for speeds above 5000 rpm.

42 ENGINEERING↗

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Developing ML/AI Methods for High-Throughput Characterization of Multiple-Sensor Streams of Tokamak Dynamics for High-Speed Control (Final Report)

This project evaluated and developed new mathematical and algorithmic techniques capable of handling (in real-time) the growing amounts of data generated by modern fusion research. While existing numerical linear algebra (NLA) methods provide the backbone to classical data analysis and algorithms, these methods fundamentally do not port to distributed architectures nor do they allow low-latency data reduction for control. Motivated by the needs for modern fusion reactors, this project explored and implemented new numerical methods to characterize plasma dynamics, respond in real-time to discharge evolution, and to process massive-scale data accurately and rapidly more fully. This project links expertise in multiple-sensor diagnostics of tokamak plasma dynamics from Columbia University’s Plasma Physics Laboratory with expertise in massive-scale data reduction and extreme data control algorithms at Columbia University’s Data Science Institute. This interdisciplinary project (i) applied machine learning methods, (ii) implemented a properly-trained neural-network for very fast processing of high-speed plasma videography, and (ii) developed the applied mathematical methods, based on randomized-NLA (rNLA) routines, for data analysis, reduction, and real-time control. The Columbia University High Beta Tokamak-Extended Pulse (HBT-EP) facility provided data to test new algorithms and partnership with Columbia University's Data Sciences Institute evaluated the broader use of new algorithms for many challenging control applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance data for an axial-flow turbine with passive adaptive blades

To support the development of simulation tools for passive adaptive turbine rotors, an experimental data set from a laboratory-scale axial-flow turbine with passive adaptive blades is provided. The 0.45-meter diameter turbine was tested in the Alice C. Tyler Flume at the University of Washington. Blade and rotor loads were measured at 1 kHz using six-axis force/torque sensors while deflection and twist at the blade tip were tracked using a high-speed camera. This data submission includes a technical report, the raw and processed experimental data, and a README file explaining the file/folder structure and where to find the processing/plotting scripts used to produce the figures in the technical report.

16 TIDAL AND WAVE POWER↗

Localized keyhole pore prediction during laser powder bed fusion via multimodal process monitoring and X-ray radiography

Systematic fault detection and control during laser powder bed fusion (L-PBF) has been a long-standing objective for system manufacturers and researchers in the additive manufacturing (AM) industry. This manuscript investigates a data fusion approach for detection of keyhole porosity formation during laser irradiation of Ti-6Al-4V substrates by concurrent recording of thermally induced optical emission measured using both off-axis and coaxial photodiode sensors, and acoustic emission. Subsurface defect formation was monitored via high-speed synchrotron X-ray imaging at 20,000 frames per second, enabling temporal registration of keyhole pore formation events to the monitoring signals at a resolution of 50 µs. We developed data fusion machine learning (ML) models for localized prediction of keyhole pore formation at various time scales ranging from 0.5 ms to 2 ms. The signal segments were featurized using two independent approaches: (1) power spectral density (PSD) and (2) highly comparative time series analysis (HCTSA) framework. The extracted features from different sensor modalities were fused together to construct a multimodal feature space and sequential feature selection was used to determine the most informative features for training the ML models. The predictive performance was evaluated for three classifying algorithms: Support Vector Machine (SVM), K-Nearest Neighbor (KNN), and Gaussian Naive Bayes (GNB). As a result, pore formation events were predicted with up to 0.95 F1-score, 1.0 recall and 0.94 accuracy. The most heavily weighted features indicate that model performance is chiefly governed by the acoustic monitoring signal, with a secondary contribution from the optical emission sensors.

36 MATERIALS SCIENCE↗

L-PBF High-Throughput Data Pipeline Approach for Multi-modal Integration

Abstract Metal-based additive manufacturing requires active monitoring solutions for assessing part quality. Multiple sensors and data streams, however, generate large heterogeneous data sets that are impractical for manual assessment and characterization. In this work, an automated pipeline is developed that enables feature extraction from high-speed camera video and multi-modal data analysis. The framework removes the need for manual assessment through the utilization of deep learning techniques and training models in a weakly supervised paradigm. We demonstrate this pipeline’s capability over 700,000 high-speed camera frames. The pipeline successfully extracts melt pool and spatter geometries and links them to corresponding pyrometry, radiography, and processparameter information. 715 individual prints are examined to reveal melt pool areas that exceeds 0.07 mm 2 and pyrometry signal over a threshold (375 pyrometry units) were more likely to have defects. These automated processes enable massive throughput of characterization techniques.

36 MATERIALS SCIENCE↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Tomographic FLEET with a wedge array for multi-point three-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) velocimetry is an important diagnostic technique for seedless velocimetry measurements particularly in supersonic and hypersonic flows. Typical FLEET measurements feature a single laser line and camera system to achieve one-component velocimetry along a line, although some multiple-spot and multiple-component configurations have been demonstrated. In this work, tomographic imaging is used to track the three-dimensional location of many FLEET spots. A quadscope is used to combine four unique views onto a single high-speed image intensifier and camera. Tomographic reconstructions of the FLEET emission are analyzed for three-component velocimetry from multiple FLEET spots. Glass wedges are used to create many (nine) closely spaced FLEET spots with less than 10% transmission losses. These developments lead to a significant improvement in the dimensionality and spatial coverage of a FLEET instrument with some increases in experimental complexity and data processing. Multiple-point three-component FLEET velocimetry is demonstrated in an underexpanded jet.

47 OTHER INSTRUMENTATION↗

In-situ sensor monitoring of multi-class gas porosity formation in laser powder bed fusion using convolutional neural network

In-situ monitoring of defect formation remains a significant challenge in the laser powder bed fusion (LPBF) process. Recent advances have enabled real-time defect detection with machine learning and in-situ sensing technologies; however, most studies focus on binary classification of keyhole pores, limiting nuanced multi-class pore differentiation and formation mechanisms. This work introduces a multi-class pore detection framework (no pore, small pores < 15 µm, and large pores > 15 µm) by leveraging photodiode sensor data alongside high-fidelity synchrotron X-ray imaging. The 15 µm threshold is selected to distinguish between two fundamentally different defect mechanisms, following the physical size-mechanism boundary established by prior high-resolution synchrotron X-ray characterization of Al6061 LPBF. Distinguishing these classes is critical because large keyhole pores are structurally detrimental, whereas small gas pores are often benign, requiring different process control strategies. Thermal emission monitoring data collected simultaneously with high-speed X-ray imaging at the Stanford Synchrotron Radiation Lightsource (SSRL), are correlated with subsurface melt pool dynamics to establish ground truth. Continuous Wavelet Transform (CWT) with optimized parameters converts the photodiode time-series signals into time–frequency images, facilitating feature extraction. Convolutional Neural Networks (CNN) are then applied for real-time multi-class pore classification in an average inference time of 1 ms per signal window. It achieves 79% accuracy and an Area Under the Receiver Operating Characteristic curve (AUC ROC) score of 0.89 with five-fold cross-validation. The results demonstrate that coupling CWT-based feature engineering with CNN architecture enables reliable multi-class pore detection in Al6061 builds using affordable in-situ sensors. This approach advances scalable and affordable quality assurance in additive manufacturing by moving beyond binary defect detection toward more nuanced classification of porosity mechanisms with in-situ sensors and machine learning.

Laser powder bed fusion, Multi-class pores, In-sit↗

Transitioning from Simulation to Reality: Applying Chatter Detection Models to Real-World Machining Data

Chatter, a self-excited vibration phenomenon, is a critical challenge in high-speed machining operations, affecting tool life, product surface quality, and overall process efficiency. While machine learning models trained on simulated data have shown promise in detecting chatter, their real-world applicability remains uncertain due to discrepancies between simulated and actual machining environments. The primary goal of this study is to bridge the gap between simulation-based machine learning models and real-world applications by developing and validating a Random Forest-based chatter detection system. This research focuses on improving manufacturing efficiency through reliable chatter detection by integrating Operational Modal Analysis (OMA), Receptance Coupling Substructure Analysis (RCSA), and Transfer Learning (TL). The study applies a Random Forest classification model trained on over 140,000 simulated machining datasets, incorporating techniques like Operational Modal Analysis (OMA), Receptance Coupling Substructure Analysis (RCSA), and Transfer Learning (TL) to adapt the model for real-world operational data. The model is validated against 1600 real-world machining datasets, achieving an accuracy of 86.1%, with strong precision and recall scores. The results demonstrate the model’s robustness and potential for practical implementation in industrial settings, highlighting challenges such as sensor noise and variability in machining conditions. This work advances the use of predictive analytics in machining processes, offering a data-driven solution to improve manufacturing efficiency through more reliable chatter detection.

42 ENGINEERING↗

Use of Convolutional Neural Network Image Classification and High-Speed Ion Probe Data Toward Real-Time Detonation Characterization in a Water-Cooled Rotating Detonation Engine

As rotating detonation engines (RDEs) progress in maturity, the importance of monitoring advancements toward development of active control becomes more critical. Experimental RDE data processing at time scales which satisfy real-time diagnostics will likely require the use of machine learning. This study aims to develop and deploy a novel real-time monitoring technique capable of determining detonation wave number, direction, frequency, and individual wave speeds throughout experimental RDE operational windows. To do so, the diagnostic integrates image classification by a convolutional neural network (CNN) and ionization current signal analysis. Wave mode identification through single-image CNN classification bypasses the need to evaluate sequential images and offers instantaneous identification of the wave mode present in the RDE annulus. Here, real-time processing speeds are achieved due to low data volumes required by the methodology, namely one short-exposure image and a short window of sensor data to generate each diagnostic output. The diagnostic acquires live data using a modified experimental setup alongside Pylon and PyDAQmx libraries within a python data acquisition environment. Lab-deployed diagnostic results are presented across varying wave modes, operating conditions, and data quality, currently executed at 3–4 Hz with a variety of iteration speed optimization options to be considered as future work. These speeds exceed that of conventional techniques and offer a proven structure for real-time RDE monitoring. The demonstrated ability to analyze detonation wave presence and behavior during RDE operation will certainly play a vital role in the development of RDE active control, necessary for RDE technology maturation toward industrial integration.

42 ENGINEERING↗

ClassNMSW- a real-time classification approach for non-recycled municipal solid waste using hyperspectral imaging

Real-time classification of non-recycled municipal solid waste (NMSW) is essential for efficient valorization. This study introduces ClassNMSW, a comprehensive framework for classifying 22 NMSW subclasses under industrial constraints by using hyperspectral imaging (HSI). A primary innovation of this work is the development of a variance-controlled spectral extraction algorithm. Unlike traditional methods that rely on simple averaging, this approach systematically investigates the extent of pixel extraction to minimize the loss of critical chemical information while maximizing data reduction thus ensuring high spectral fidelity with low computational cost. The approach developed in this work integrates automated, computer-vision-based background removal, eliminating the need for the manual thresholding common in current literature. To resolve ambiguities among chemically similar subclasses, a tiered classification and multi-camera fusion strategy (NIR17 and NIR22) is implemented. Results demonstrate that ClassNMSW achieves an object-wise weighted accuracy of 98.70% for single-sensor configurations and 100% under sensor fusion. A novel rolling-window strategy satisfies desired end-to-end latency of <2 s, satisfying the strict deterministic requirements of high-speed industrial sorting environments. The ClassNMSW framework provides a scalable foundation for advancing circularity and resource recovery in large-scale waste valorization operations.

99 - GENERAL AND MISCELLANEOUS↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Machine-Learning-Based Rotating Detonation Engine Diagnostics: Evaluation for Application in Experimental Facilities

Real-time monitoring of combustion behavior is a crucial step toward actively controlled rotating detonation engine (RDE) operation in laboratory and industrial environments. Various machine learning methods have been developed to advance diagnostic efficiencies from conventional postprocessing efforts to real-time methods. Here this work evaluates and compares conventional techniques alongside convolutional neural network (CNN) architectures trained in previous studies, including image classification, object detection, and time series classification, according to metrics affecting diagnostic feasibility, external applicability, and performance. Real-time, capable diagnostics are deployed and evaluated using an altered experimental setup. Image-based CNNs are applied to externally provided images to approximate dataset restrictions. Image classification using high-speed chemiluminescence images and time series classification using high-speed flame ionization and pressure measurements achieve classification speeds enabling real-time diagnostic capabilities, averaging laboratory-deployed diagnostic feedback rates of 4–5 Hz. Object detection achieves the most refined resolution of 20 μs in postprocessing. Image and time series classification require the additional correlation of sensor data, extending their time-step resolutions to 80 ms. Comparisons show that no single diagnostic approach outperforms its competitors across all metrics. This finding justifies the need for a machine learning portfolio containing a host of networks to address specific needs throughout the RDE research community.

33 ADVANCED PROPULSION SYSTEMS↗