Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Scientific Computational Imaging Code (SCICO)

Scientific Computational Imaging Code (SCICO) is a Python package for solving the inverse problems that arise in scientific imaging applications. Its primary focus is providing methods for solving ill-posed inverse problems by using an appropriate prior model of the reconstruction space. SCICO includes a growing suite of operators, cost functionals, regularizers, and optimization routines that may be combined to solve a wide range of problems, and is designed so that it is easy to add new building blocks. SCICO is built on top of JAX rather than NumPy, enabling GPU/TPU acceleration, just-in-time compilation, and automatic gradient functionality, which is used to automatically compute the adjoints of linear operators. An example of how to solve a multi-channel tomography problem with SCICO is shown in Figure 1. The SCICO source code is available from GitHub, and pre-built packages are available from PyPI. It has extensive online documentation, including API documentation and usage examples, which can be run online at Google Colab and binder.

97 MATHEMATICS AND COMPUTING↗

Whole-scene, one-sided backscatter x-ray imaging with coded apertures

X-ray radiography can be an important diagnostic for emergency response, providing timely diagnostic information about a suspect object. However, there are situations where similar information would be better obtained with a one-sided imaging technique. X-ray backscatter imaging is a proven technology that could provide such information, but current implementations have drawbacks that render it unsuitable for emergency response. We are exploring the use of coded-aperture imaging to create one-sided images, targeting a key benefit: implementation requiring minimal additional resources, bypassing logistics issues. We present results demonstrating the feasibility of this approach.

Ziock, Klaus-Peter [ORNL]↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

HERMES

HERMES - High-speed Event Retrieval and Management for Enhanced Spectral imaging code. This code is meant to unpack and process neutron imaging data from the TPX3Cam made by Amsterdam Scientific Instruments. The TPX3Cam utilizes the Timepix3 chip in a single photon counting mode of image acquisition. The photon counting data streaming off the TPX3Cam needs to be process and analyzed in order to create final images. Therefore we are developing both python and cpp codes to allow for users of the TPX3Cam to efficiently analyze data and create images.

Long, Alexander↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

Development of a true single line of sight 3D hot-spot imaging for the National Ignition Facility

High resolution 3D self-emission x-ray imaging during inertial confinement fusion capsule implosion enables the measurement of the shape of the hotspot. While current 3D imaging capabilities use multiple lines of sight to perform image reconstruction, it would be highly desirable to use only one line of sight, as this would significantly reduce the number of windows in the target hohlraum and decrease their impacts on implosion symmetry. Such a goal is achievable using the zone plate coded imaging technique developed by N. M. Ceglio [Proc. SPIE 0106, 55-62 (1977)]. It consists of fielding a visible light Fresnel zone plate on shot to record a shadowgraph. Here, the image can then be reconstructed either by printing the shadowgraph on a transparent film and shining a suitable wavelength light through it or by numerical reconstruction. A new approach using numerical reconstruction is presented, and it relaxes the constraint by an order of magnitude on the optic design, thus enabling an easier fabrication process, as it allows a scaling-up of the optic dimensions. The design, fabrication process, and testing with an x-ray source of a prototype is presented. The reconstruction of an ~14.5 × 17 μm 2 broadband x-ray source was successful and shows that the performances are in line with expectation with an at least 5 mm axial resolution.

47 OTHER INSTRUMENTATION↗

Leveraging interpolation models and error bounds for verifiable scientific machine learning

Effective verification and validation techniques for modern scientific machine learning workflows are challenging to devise. Statistical methods are abundant and easily deployed, but often rely on speculative assumptions about the data and methods involved. Error bounds for classical interpolation techniques can provide mathematically rigorous estimates of accuracy, but often are difficult or impractical to determine computationally. Here, in this work, we present a best-of-both-worlds approach to verifiable scientific machine learning by demonstrating that (1) multiple standard interpolation techniques have informative error bounds that can be computed or estimated efficiently; (2) comparative performance among distinct interpolants can aid in validation goals; (3) deploying interpolation methods on latent spaces generated by deep learning techniques enables some interpretability for black-box models. We present a detailed case study of our approach for predicting lift-drag ratios from airfoil images. Code developed for this work is available in a public Github repository.

97 MATHEMATICS AND COMPUTING↗

Single-shot x-ray phase-contrast and dark-field imaging based on coded binary phase mask

We introduce a coded-mask-based multi-contrast imaging method for high-resolution phase-contrast and dark-field imaging. The method uses a binary phase mask designed to provide an ultra-high-contrast pattern and reference-free single-shot measurement and an algorithm based on maximum-likelihood optimization and automatic differentiation to perform simultaneous reconstruction of absorption, phase, and dark-field object images. Further, we demonstrate that the method has great potential for real-time quantitative phase imaging and wavefront sensing when combined with deep learning.

Qiao, Zhi (ORCID:0000000286285320)↗

Machine Learning for Cardiac Electrical Imaging

PyTorch code for cardiac electrical imaging using the 12-lead ECG. This code is associated with the paper from CINC 2022. If you use this code, please cite: Paper : https://cinc.org/2022/Program/accepted/26_Preprint.pdf Dataset : https://library.ucsd.edu/dc/object/bb29449106 The code support two tasks: Task 1: Activation Map Reconstruction from ECG Task 2: Transmembrane potential Reconstruction from ECG

Larma, MikelLandajuela↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Out of distribution evaluation for neural image compression

Official code for the NeurIPS 2023 paper "Neural Image Compression: Generalization, Robustness, and Spectral Biases". This code can be used to: - Computing spectral distortion errors of images compressed with traditional codes or neural image compression models (as proposed in the aformentioned paper) - Visualize power spectral densities and fourier heatmaps (as proposed in the aformentioned paper) - Train and test a variety of neural image compression models

Lieberman, KelseyA↗

Quantitative Holdup Determinations Using Coded-Aperture Gamma-Ray Imaging

Passive gamma-ray imaging can be used to create images of distributed nuclear materials. Inherently quantitative, the images provide a means to directly determine the amount of nuclear material in the imager’s field of view. However, to take advantage of quantitative imaging, one must correct for changes to the imager’s efficiency across the image. This paper presents work on detailed calibration of a coded-aperture imager based on a portable, mechanically cooled, high-purity germanium detector. This enables the use of gamma-ray imaging as a tool to determine nuclear holdup. By applying the calibrations to images of small amounts of distributed 235U, quantity estimates within a few percent of the actual amounts present were obtained, validating the approach.

Ziock, Klaus-Peter↗