Search NASA⌕ Search

SEARCH · Search NASA

Results for “image metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

Dense Image Matching Uncertainty Estimation and Confidence Metrics

Dense stereo matching takes overlapping image pairs as input and outputs a disparity map which encodes pixel-by-pixel matches between the images. Recently, there has been an interest in ranking the quality, or even quantifying the accuracy, of disparity estimates. The proposed methods can be described as either uncertainty estimators or confidence metrics. Uncertainty estimators are a small minority of the research. However, they have the potential to be the most useful because they estimate disparity accuracy (in pixel units) that can be used to threshold matches or carried forward using error propagation. The majority of the research deals with confidence metrics which give an ordinal (or binary) ranking of a match’s quality relative to other matches. Confidence metrics do not have units and thus are useful primarily for thresholding matches from mismatches. The methods could also be described as handcrafted or deep-learning based. The majority of the research focused on outdoor driving scenes. Hence, our interest–application to a satellite semi-global matching pipeline–is a domain shift that may challenge deep-learning based methods. We conclude by recommending five handcrafted and two deep-learning based methods for evaluation in our pipeline.

97 MATHEMATICS AND COMPUTING↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Explainable artificial intelligence relates perovskite luminescence images to current-voltage metrics

As the demand for low-cost, high-efficiency solar energy technologies grows, metal halide perovskite (MHP) solar cells have emerged as a promising candidate for next-generation photovoltaics due to their high power conversion efficiencies. However, their poor durability and issues with manufacturing consistency remain significant barriers to commercialization. In this work, we develop deep learning models to support materials characterization and provide insight into features and processes influencing performance. The models are trained using transfer learning of a pretrained model to predict relevant current-voltage (IV) metrics based on different combinations of input electroluminescence (EL) and photoluminescence (PL) images of MHP devices. We examine which image types are most informative in accurately predicting different IV metrics. Additionally, we use explainable artificial intelligence (XAI) techniques to provide insights into specific spatial features in the devices that drive differences in performance. We find that stabilized luminescence images (e.g. those collected after biasing the devices for at least 1 min) are better for predicting metrics of open-circuit voltage (by PL) and short-circuit current (by PL with EL), but that predicting fill factor and overall power output may use the time-evolution of EL images. Based on attribution masks generated by integrated gradients for each device performance metric, we further suggest different loss mechanisms associated with categories of large and small spatial defects. Overall, this case study highlights the potential applicability of XAI methodology for streamlining MHP device analysis and accelerating detailed understanding of the relationships between spatial defects and impacts on performance.

14 SOLAR ENERGY↗

Surrogate Distributed Radiological Sources—Part III: Quantitative Distributed Source Reconstructions

In this third part of a multi-paper series, we present quantitative image reconstruction results from aerial measurements of eight different surrogate distributed gamma-ray sources on flat terrain. Here, we show that our quantitative imaging methods can accurately reconstruct the expected shapes, and, after appropriate calibration, the absolute activity of the distributed sources. We conduct several studies of imaging performance versus various measurement and reconstruction parameters, including detector altitude and raster pass spacing, data and modeling fidelity, and regularization type and strength. The imaging quality performance is quantified using various quantitative image quality metrics. Our results confirm the utility of point source arrays as surrogates for truly distributed radiological sources, and advance the quantitative capabilities of Scene Data Fusion gamma-ray imaging methods.

Airborne survey↗

The Double-edged Sword of Data-driven Super-Resolution: Adversarial Super-resolution Models

Data-driven super-resolution (SR) methods are often integrated into imaging pipelines as preprocessing steps to improve downstream tasks such as classification and detection. However, these SR models introduce a previously unexplored attack surface into imaging pipelines. In this paper, we present AdvSR, a framework demonstrating that adversarial behavior can be embedded directly into SR model weights during training, requiring no access to inputs at inference time. Unlike prior attacks that perturb inputs or rely on backdoor triggers, AdvSR operates entirely at the model level. By jointly optimizing for reconstruction quality and targeted adversarial outcomes, AdvSR produces models that appear benign under standard image quality metrics while inducing downstream misclassification. We evaluate AdvSR on three SR architectures (SRCNN, EDSR, SwinIR) paired with a YOLOv11 classifier and demonstrate that AdvSR models can achieve high attack success rates with minimal quality degradation. These findings highlight a new model-level threat for imaging pipelines, with implications for how practitioners source and validate models in safety-critical applications.

Sullivan, Haley [ORNL] (ORCID:0000000274069217)↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗

Tomographic FLEET with a wedge array for multi-point three-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) velocimetry is an important diagnostic technique for seedless velocimetry measurements particularly in supersonic and hypersonic flows. Typical FLEET measurements feature a single laser line and camera system to achieve one-component velocimetry along a line, although some multiple-spot and multiple-component configurations have been demonstrated. In this work, tomographic imaging is used to track the three-dimensional location of many FLEET spots. A quadscope is used to combine four unique views onto a single high-speed image intensifier and camera. Tomographic reconstructions of the FLEET emission are analyzed for three-component velocimetry from multiple FLEET spots. Glass wedges are used to create many (nine) closely spaced FLEET spots with less than 10% transmission losses. These developments lead to a significant improvement in the dimensionality and spatial coverage of a FLEET instrument with some increases in experimental complexity and data processing. Multiple-point three-component FLEET velocimetry is demonstrated in an underexpanded jet.

47 OTHER INSTRUMENTATION↗

Missing Wedge Completion via Unsupervised Learning with Coordinate Networks

Cryogenic electron tomography (cryoET) is a powerful tool in structural biology, enabling detailed 3D imaging of biological specimens at a resolution of nanometers. Despite its potential, cryoET faces challenges such as the missing wedge problem, which limits reconstruction quality due to incomplete data collection angles. Recently, supervised deep learning methods leveraging convolutional neural networks (CNNs) have considerably addressed this issue; however, their pretraining requirements render them susceptible to inaccuracies and artifacts, particularly when representative training data is scarce. To overcome these limitations, we introduce a proof-of-concept unsupervised learning approach using coordinate networks (CNs) that optimizes network weights directly against input projections. This eliminates the need for pretraining, reducing reconstruction runtime by 3–20× compared to supervised methods. Our in silico results show improved shape completion and reduction of missing wedge artifacts, assessed through several voxel-based image quality metrics in real space and a novel directional Fourier Shell Correlation (FSC) metric. Our study illuminates benefits and considerations of both supervised and unsupervised approaches, guiding the development of improved reconstruction strategies.

42 ENGINEERING↗

Score-based diffusion models for generating liquid argon time projection chamber images

For the first time, we show high-fidelity generation of Liquid Argon Time Projection Chamber (LArTPC-like) data using a generative neural network. This demonstrates that methods developed for natural images do transfer to LArTPC-produced images, which, in contrast to natural images, are globally sparse but locally dense. We present the score-based diffusion method employed. We evaluate the fidelity of the generated images using several quality metrics, including modified measures used to evaluate natural images, comparisons between high-dimensional distributions, and comparisons relevant to LArTPC experiments. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is a tool to measure optical spectra from the effects of dark energy on the universe and has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and some metrics for data quality and tools used for ICARUS monitoring.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics for Data Quality

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is an astronomical project measuring millions of optical spectra to characterize Dark Energy. The survey has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs (Charge-Coupled Devices) which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and additional metrics for data quality and tools used for ICARUS monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic Image Point Matching

Sparse Image Point Matching (SIPM) is a foundational technology for photo triangulation, structure from motion (SfM), Simultaneous Location and Mapping (SLAM), and data fusion. The goal of the matching is to automatically generate sets of image coordinates that identify the same feature across images. Ideally, the process should be robust to lighting, scale, perspective, and modality changes. The scope of the image matching topic in the field of remote sensing (RS) is enormous because of the variety of collection platforms, modalities, sensor types, applications, and subjects. In this work, we report the history of and assess the state of the art of visible-spectrum (panchromatic and color) image matching of the Earth’s surface. Work specific to large-format images (LFI) (e.g., metric aerial cameras and Earth-observing satellites) will be highlighted. However, the state of the art in this century will mostly be traced through machine vision research and benchmarks because research specific to LFI is rare.

97 MATHEMATICS AND COMPUTING↗

Identifying Outliers in AI-based Image Compression

Image compression using artificial intelligence (AI) is becoming increasingly prevalent across various fields, including scientific research. Scientific instruments can generate hundreds of images per second, and effectively compressing these images with high compression ratios is crucial for facilitating scientific discoveries. However, automatically detecting outlier cases, where compression may not have succeeded or where interesting scientific phenomena are present, poses a significant challenge. To address this, we have developed a methodology based on unsupervised machine learning techniques for detecting outlier compressed images. This methodology utilizes metrics such as peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), structural texture similarity index measure (STSIM), and deep image and structural texture similarity index (DISTS). We have evaluated our methodology on several unlabeled datasets, including microscopy and x-ray images, and have successfully identified multiple outlier images using our proposed approach. Furthermore, our approach has enabled us to identify image semantics that are valuable for post-experiment analysis by scientists.

Data Analysis↗

Automated Scoring of Morphological Changes in Images of Pentaerythritol Tetranitrate

Recent advances in characterization techniques that generate large datasets of material microstructure images require robust, automated image-processing. We applied an unsupervised anomaly detection method called feature anomaly detection system (FADS) to automatically detect and quantify microstructure changes in images of the explosive pentaerythritol tetranitrate (PETN) aged at various temperatures. We demonstrated the FADS approach on two-dimensional images extracted from computed tomography scans, but the same technique can be readily applied to other imaging modalities. FADS calculates anomaly scores on the basis of differences in filter activations of nominal and test data in pretrained convolutional neural networks. The FADS scores successfully differentiated between pristine PETN and PETN aged at a temperature where material coarsening occurred. Morphological metric analysis of segmented images verified observed trends in FADS scores as a function of aging temperature and aging time, specifically by calculating volume fractions, specific boundary lengths, two-point correlation functions, and local thicknesses. Here, the FADS technique has two important advantages compared to traditional morphological analysis: First, it uses grayscale images as input, rather than images that are segmented to separate the appropriate phases; and second, FADS scores capture any type of changes among image sets, rather than requiring prior knowledge or selection of a relevant set of metrics.

Accelerated aging↗