Search NASA⌕ Search

SEARCH · Search NASA

Results for “impact study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Severe Temperature Impact Study on Ferrite Electromagnetic Shielding for Wireless Electric Vehicle Charging

Wireless charging of an electric vehicle (EV) is an emerging technology that enables noncontact charging, which has advantages in terms of convenience and flexibility. However, the embedded charging pads under and on the ground expose the charging coils, ferrite shielding, and related components to a potentially severe external environment. To study the electromagnetic shielding performance under such extreme temperature conditions, ferrite shielding material's permeability characteristics are tested under temperatures as low as -50°C to as high as 240°C. Referring to the official recorded lowest and highest temperature of the United States, in this paper, it is assumed that the operation temperature ranges from -50°C to 57°C as the coldest winter and hottest summer environment for WPT application. Electromagnetic performance, shielding, and associated stray magnetic emissions are simulated by using three-dimensional (3D) transient simulations to study the impact of low and high temperature on electromagnetic shielding performance. Based on ferrite testing data, from -50°C low temperature to 57°C high temperature, the ferrite's relative permeability ranges from 2550 to 3727. The simulation study indicates that there won't be significant impact on the EM shielding performance for WPT operated under those severe environment temperature conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Spatial Resolution in a High-Fidelity Capacity Expansion Model: An ERCOT Case Study

Capacity expansion models are important tools in examining the evolution of the electric power sector. Embedded in these tools are many modeling choices with consequential impacts on computational burden and associated analysis. In this study, we adjust the spatial resolution of the Regional Energy Deployment System (ReEDS) to understand the implications of higher-fidelity modeling on energy system projections and model solve times. The native ReEDS regions capture the contiguous United States in 134 balancing areas whereas the regions in the higher-resolution version are defined by over 3,000 U.S. counties. Using both resolutions, we conduct a case study of the Texas Interconnection (The Electric Reliability Council of Texas [ERCOT]) to explore differences in model projections and to inform appropriate applications of high spatial resolution in a large-scale, applied capacity expansion model.

county↗

Transportation Electrification Impact Study (TEIS)

Recent U.S. Environmental Protection Agency (EPA) notices of proposed rulemakings for GHG emissions standards for light-, medium-, and heavy-duty on-road vehicles would accelerate ongoing advancements already happening in the industry because of private investment, consumer demand, state-level policies, and federal incentives. As the EPA finalizes these regulations, questions persist regarding the cost of the requisite charging infrastructure and associated upgrades to the nation's electric grid. With support from the U.S. Department of Energy, U.S. Joint Office of Energy and Transportation, and the EPA, a multidisciplinary team conducted a Multi-State Transportation Electrification Impact Study that quantitatively assesses the incremental investment necessary to enable the levels of vehicle electrification expected to be induced by pending EPA regulations and to estimate the potential value of deferred investments in electric distribution infrastructure stemming from proactive vehicle-grid integration planning and deployment. This study finds the simulated incremental capital cost of charging infrastructure (including grid upgrades) to be at least 2.5 times smaller than the lifetime net benefits of vehicle electrification (including fuel savings but excluding the value of avoided emissions). Additionally, the incremental distribution grid upgrade cost of the EPA Action-Unmanaged scenario was found to be approximately 3% of existing utility distribution system investments (on an annual basis). Finally, the potential for managed charging to defer distribution grid upgrades was found to be significant with costs found to decrease from $2.3 billion to an incremental cost of $1 billion across five states in the Action-Managed scenario (relative to the No Action-Unmanaged scenario).

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Multi-State Transportation Electrification Impact Study: Preparing the Grid for Light-, Medium-, and Heavy-Duty Electric Vehicles

Recent U.S. Environmental Protection Agency (EPA) notices of proposed rulemakings for GHG emissions standards for light-, medium-, and heavy-duty on-road vehicles would accelerate ongoing advancements already happening in the industry because of private investment, consumer demand, state-level policies, and federal incentives. As the EPA finalizes these regulations, questions persist regarding the cost of the requisite charging infrastructure and associated upgrades to the nation's electric grid. With support from the U.S. Department of Energy, U.S. Joint Office of Energy and Transportation, and the EPA, a multidisciplinary team conducted a Multi-State Transportation Electrification Impact Study that quantitatively assesses the incremental investment necessary to enable the levels of vehicle electrification expected to be induced by pending EPA regulations and to estimate the potential value of deferred investments in electric distribution infrastructure stemming from proactive vehicle-grid integration planning and deployment. This study finds the simulated incremental capital cost of charging infrastructure (including grid upgrades) to be at least 2.5 times smaller than the lifetime net benefits of vehicle electrification (including fuel savings but excluding the value of avoided emissions). Additionally, the incremental distribution grid upgrade cost of the EPA Action-Unmanaged scenario was found to be approximately 3% of existing utility distribution system investments (on an annual basis). Finally, the potential for managed charging to defer distribution grid upgrades was found to be significant with costs found to decrease from $2.3 billion to an incremental cost of $1 billion across five states in the Action-Managed scenario (relative to the No Action-Unmanaged scenario).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Rheology Models on Horizontal Well Polymer Flooding in a Heavy Oil Reservoir on Alaska North Slope: A Simulation Study

Polymer rheology can have either a positive or a negative effect on polymer flooding performance under varied circumstances. Many researchers have studied the effect of polymer rheology in a vertical well, but no field scale studies have been conducted to investigate whether polymer rheology is beneficial to polymer flooding in heavy oil reservoirs developed by horizontal wells. In this paper, we conducted a numerical simulation study to examine the effect of HPAM polymer rheology on a polymer flooding pilot, which is the first-ever project conducted on a heavy oil reservoir from Alaska North Slope (ANS) developed by horizontal wells. Three rheology types were considered in the study including the apparent viscosity measured during coreflooding of using a HPAM polymer, the bulk viscosity measured with a viscometer, and a Newtonian flow model. The results suggest that using the bulk viscosity in simulation underestimates the conformance control and the water-oil-ratio reduction capability of the HPAM polymer solution. When the apparent viscosity is used, the incremental oil and sweep were largely increased, and the optimal recovery period of polymer flooding was extended greatly, especially for the heterogeneous formations. Therefore, the rheology type of polymer plays a significant role in the incremental oil recovery and injection profile of the horizontal well system given the pilot test conditions. This study has provided practical guidance to field operators for the ongoing polymer flooding pilot on ANS and will also provide valuable information for other polymer projects conducted in similar conditions.

Leng, Jianqiao↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced grid-forming (GFM) inverter controls, modeling and system impact study for inverter dominated grids

Our main goals in this project are to understand: 1) the stability of the power system with very high penetration of PV or other inverter-based resources (IBR), 2) the interactions among IBRs and traditional generators, and 3) the impact of the GFM inverters on bulk power system. To achieve these goals, we took a holistic research and development approach. First, an impedance-based large system modeling and stability analysis tool was developed to aid the large IBR system small-signal stability analysis. Second, consensus-based control and transient overload ride through were developed to control and coordinate multiple GFM inverters in a large system to maintain transient stability during big grid events. Third, high fidelity electromagnetic transient (EMT) IBR models were developed and integrated into a large reduced WECC model to study the system impact from IBRs. Lastly, extensive validation tests of the GFM control which was developed in this project and implemented in two 1MW commercial solar inverters were performed using different validation platforms, e.g., control hardware-in-the-loop (CHIL) platform, power hardware- in-the-loop (PHIL) platform, and a real PV plant.

14 SOLAR ENERGY↗

Impact Study of Thunderstorms on the US Power Grid Using Publicly Available Datasets

This work analyzes the impact of thunderstorms on the US power grid based on publicly available data. Since thunderstorms can bring lightning, heavy precipitation, and wind storms, analyzing their impact on the power system provides a combined correlation of lightning strikes, floods, and wind storms on power outages. This paper leverages publicly available thunderstorm datasets from the National Weather Service (NWS) and power outage datasets from Oak Ridge National Laboratory’s Environment for Analysis of Geo-Located Energy Information (EAGLE-I) to study the correlation between thunderstorms and power outages. This work is analyzing the patterns of thunderstorms from 2013-2022, which shows that the thunderstorms are not slowing down and will seem to continue their impact on human life in the future. This work also analyzes the monthly and yearly pattern of the impact of thunderstorms on power systems at the national, state, and county level.

Bhusal, Narayan↗

FCC feasibility studies: Impact of tracker- and calorimeter-detector performance on jet flavor identification and Higgs physics analyses

The ambitious physics program planned for the Future Circular Collider electron-positron phase imposes stringent constraints on detector performance. This study systematically investigates how different detector configurations impact jet flavor identification and their effects on high-profile physics analyses. Using Higgs boson coupling measurements and searches for invisible Higgs decays as benchmarks, we evaluate the sensitivity of these analyses to variations in tracker and calorimeter detector properties. We examine modifications to single-point resolution, material budget, silicon layer placement, and particle identification capabilities, quantifying their effects on flavor-tagging performance. Additionally, we present the first comprehensive study of Higgs-to-invisible decay detection using full detector simulation, providing insights for optimizing detector designs at lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electrification Futures Study: Impact of Electric Vehicles on Bulk Power Systems

This presentation builds on work presented at IEW2019 on "Transportation Scenarios of Electric Technology Adoption and Power Consumption" by providing insights on the impact of demand-side electrification, and electric vehicles in particular, on electricity supply and bulk power systems. This talk summarizes some results from the multi-year and multi-stakeholder Electrification Futures Study (EFS) series of reports. In particular, this work leverages integrated demand and supply modelling of future energy systems to provide insights on system design and operations focusing on demand flexibility and integration of variable renewables.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

Engaging a Diverse Workforce in the Building Sciences Through the JUMP Into STEM Program: Impact Study; Preprint

Ensuring inclusivity in building science professions requires engaging people from underrepresented demographics; unfortunately, many races, ethnicities, and genders continue to be underrepresented. The JUMP into STEM program works to rectify this, encouraging creative ideation and highlighting the unique perspectives of a diverse array of students. The top students are awarded internships that provide opportunities to work in building science research with close supervision from mentors in the field. In the research presented here, we investigate the impact of participation in JUMP into STEM on students' careers, including the impact on students from diverse backgrounds. Furthermore, we research students' awareness of career opportunities in building science, students' perception of their ability to meaningfully contribute to this field, and the career building opportunities that JUMP into STEM provides for students. Through participant interviews and data analysis, we measure program diversity, inclusion, and effectiveness at achieving goals. We find that among the hundreds of students who have participated in this program, more than 25 different majors and/or educational degree programs are represented and more than 45% of students attend minority serving institutions or historically black colleges and universities. The JUMP into STEM experience had a significant effect on career choices or career development for more than 80% of participants. Our results also indicate that the JUMP into STEM program is effective at promoting diversity in the building sciences and is successfully contributing to the larger effort within the building science industry to promote and ensure equity in technological progress and innovation.

building energy science↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Degradation and recovery of solid oxide fuel cell performance by control of cathode surface acidity: Case study – Impact of Cr followed by Ca infiltration

Solid oxide fuel cells (SOFC) have attracted attention as clean and efficient energy conversion devices with low emissions. However, several degradation mechanisms limit the electrochemical performance of current SOFCs, with cathode degradation due to Cr-poisoning from metal interconnects particularly problematic. The acidity/basicity of binary additives has been found to be a sensitive descriptor of the oxygen exchange kinetics, indicating that acidic Cr-species/basic Ca-species can be expected to deactivate/activate the cathode surface, respectively. Inspired by recent advances, the feasibility of relative acidity as a tool for reviving degraded SOFCs is demonstrated by neutralizing Cr-poisoned SOFCs by subsequent serial infiltration of Ca-species. Furthermore, a model mixed ionic and electronic conducting oxide, Pr 0.1 Ce 0.9 O 2-δ (PCO), is selected as the cathode material. Area-specific resistances (ASR) of symmetric cells obtained by electrochemical impedance spectroscopy show that Cr-infiltration results in a seven-fold increase in ASR, while subsequent infiltration of Ca-species leads to complete recovery. Performance degradation and recovery are attributed to depressed/enhanced redox properties at the PCO surface, as supported by XPS analysis. Experiments using anode-supported fuel cells show a reduction in peak power density by 26% upon Cr-infiltration, reversed following Ca-infiltration, after which no degradation is observed during subsequent operation for 100 h.

(Pr,Ce)O2-δ↗

Data, scripts, and figures associated with a manuscript studying impact of climate and topography on post-fire vegetation recovery.

This data package is associated with the publication “Impact of Topography and Climate on Post-fire Vegetation Recovery Across Different Burn Severity and Land Cover Types through Machine Learning” submitted to Remote Sensing of Environment (Zahura et al. 2023). In this research, a machine learning algorithm, random forest (RF), was utilized to examine the impact of climate and topography on post-fire vegetation recovery. We used enhanced vegetation index (EVI) to examine varying burn severity and land cover types. The data package includes the input files for RF model training, outputs from model predictions and analysis, and python scripts to run the model, analyze the results to understand model performance and interpretability, and plot manuscript figures. This data package contains three folders (Data, Scripts, and Figures), a file-level metadata (FLMD) csv, and a data dictionary (dd) csv. Please see Postfire_recovery_flmd.csv for a list of all files contained in this data package and descriptions for each. The data dictionary (Postfire_recovery_dd.csv) describes the csv column headers. The “Data” folder provides all the inputs and outputs to train the RF model, evaluate performance, and interpret predictions. The “Scripts” folder contains python scripts and jupyter notebooks for model training and result analysis. The “Figures” folder includes the figures used in the manuscript in “.png” and “.jpg” format.

54 ENVIRONMENTAL SCIENCES↗