Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedance modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impedance model for the Fermilab Recycler ring

We present an impedance model of the Fermilab Recycler ring using PyHEADTAIL. The model is constructed by incorporating analytical expressions for the wakefields of beamline components that contribute significantly to impedance. The effects of indirect space charge are included as an inductive impedance. Benchmarking against measured coherent Betatron tune shifts, the impedance model is found to capture 73.4% of observed tune shifts. Our findings serve as a stepping stone for the development of a realistic impedance model crucial for studying impedance-driven instabilities at higher intensity.

43 PARTICLE ACCELERATORS↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid- following inverter↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid-following inverter↗

Sequence Impedance Modeling of Grid-Forming Converters: Preprint

Grid-forming control of inverter-based resources (IBRs) has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents sequence impedance modeling of grid-forming inverters to evaluate its small-signal stability properties. Droop based grid-forming control with full consideration of the multiloop structure is studied, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Broadband impedance modeling and single bunch instabilities estimations of the advanced light source upgrade project

We report the Advanced Light Source Upgrade (ALS-U) is a 4th generation diffraction-limited soft x-ray radiation source, consisting of a new accumulator ring (AR) and a new storage ring (SR). In both rings coupling-impedance driven instabilities need careful evaluation to ensure meeting the machine’s high-performance goals. This paper presents the workflow followed in building the impedance models and the beam-stability analysis based on those models. We follow the commonly accepted approach of separating the resistive-wall and the geometric parts of the impedance; the former is obtained by analytical formulas, the latter by numerical electro-magnetic codes (primarily CST Studio software) with perfectly-conducting boundary conditions. Impedance budgets are established and pseudo-Green functions calculated to be used in beam dynamics studies. We also present various ways to cross-check simulation results for reliable impedance modeling. Finally, the crucial single-bunch instability current thresholds for various operation modes are determined and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Impedance Modeling and Stability Analysis for the PLL-less and Voltage Sensor-less Grid-tied Converters

The newly developed control methodology, which omits the phase-locked loop (PLL) and voltage sensor, has garnered considerable attention for its rapid dynamic response and reduced hardware expenses. Nonetheless, its stability concerns have not yet been thoroughly scrutinized. In this paper, the impedance modeling of the PLL-less and voltage sensorless control strategy has been established. The impedance model has been contrasted with the traditional PLL-based control scheme. Our findings demonstrate that the PLL-less and voltage sensorless control approach lacks the negative resistance behavior that is frequently observed in the traditional scheme, which results in unstable operations. Furthermore, the role of virtual resistance has been examined. To substantiate the aforementioned findings, simulation results are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impedance Modeling for Mixed Conductors with Simultaneous Insertion & Electrocatalytic Reactions: A Case Study of Transition-Metal Hydroxides in Aqueous Electrolyte

Electrochemical impedance spectroscopy (EIS) is commonly used to investigate the kinetics of mixed ionic–electronic conductor (MIEC) electrodes. Across various applications, MIECs exhibit ionic (e.g., insertion) and/or electronic (e.g., electrocatalytic) charge transfer reactions at the electrode/electrolyte interface. Bulk storage and transport of charge carriers also couple with these interfacial reactions. Here, we build a generalized, physics-based impedance model for MIECs with an ion-blocking current collector and explore how bulk and interfacial resistance, chemical capacitance, and DC polarization affect the impedance response. Using transition metal hydroxides as a case study, we provide guidance on extracting reaction kinetics or bulk resistance from the Nyquist plots in interface- or bulk-controlled conditions, respectively. Generalizing our EIS analysis enables a robust analysis of MIEC kinetics for a diverse set of systems.

36 MATERIALS SCIENCE↗

Modeling Impedance Caused by Ohmic Losses in High Surface Area Carbons in Polymer Electrolyte Fuel Cells

An analytical model for a blocking porous electrode is derived and used to predict how ohmic resistance inside micropores that host catalyst nanoparticles affects impedance. This paper revisits a widely used approach for estimating ionic conductivities of catalyst layers in fuel cells. An interfacial term associated with resistance in micropores is derived and added to the classical expression for the impedance of a blocking porous electrode at low frequency. The revised model predicts a physically realistic rise in the real component of the impedance at low frequency when reasonable pore dimensions and conductivities are used as inputs.

08 HYDROGEN↗

Electron and proton conductivity of Fe-N-C cathodes for PEM fuel cells: A model-based electrochemical impedance spectroscopy measurement

Impedance spectra of a PEM fuel cell with three Fe-N-C cathodes have been measured under the H 2 /N 2 testing regime. The spectra have been fitted using a recently developed physics-based impedance model, which takes into account finite proton ($σ_p$) and electron ($σ_e$) conductivity of the oxygen-free cathode catalyst layer. Fitting allowed to extract numerical data for $σ_p$, $σ_e$, the double layer capacitance, and the inductance of cables used for measuring impedance spectra. The values of σp and σe are close to what previously found for standard Pt/C electrodes, which is found for the first time using PGM-free catalysts. The method enables simultaneous measurement of reference proton and electron conductivity of PEMFC cathode.

25 ENERGY STORAGE↗

A New Impedance-Based Modeling and Stability Analysis Approach for Power Oscillations Between Grid-Forming Inverters

This paper presents a new modeling and analysis approach to address the small-signal stability issues among interconnected grid-forming (GFM) inverters. A novel phasor domain “power impedance” model is developed to capture the terminal characteristics of GFM inverters. Based on the developed models, a sum-type impedance stability criterion is proposed to analyze the power oscillations between GFM Inverters. The developed models are validated with EMT simulations and the stability analysis results using the proposed stability criterion can match both EMT simulations and eigenvalue analysis. In addition, the application of the developed model can be extended to the stability analysis of large-scale power system with high penetration of GFM inverters.

Liu, Hanchao↗

Impedance‐matching model‐in‐the‐loop simulation

Abstract Impedance matching is a novel approach to executing model‐in‐the‐loop (MIL) simulations. The concept, key features, and sample applications of this approach have been described in a series of publications. This paper advances theory and implementation for impedance‐matching MIL by: (1) developing a feedback linearization technique for implementing MIL for nonlinear virtual systems, (2) systematically characterizing MIL performance‐stability tradeoffs using three design‐oriented criteria—performance: defined as closeness of the controlled‐actuator impedance to the virtual‐boundary impedance;control effort: low controller response at high frequencies to reduce sensitivity to measurement noise and uncertainties in the actuator model; andstability: pursued using passivity of the controlled actuator system, and (3) assessing, through experimentation, the robustness of two ways to estimate feedback reaction force from the test article. These fundamental advancements to MIL are described using a one‐dimensional configuration consisting of a fluid‐filled cylindrical vessel as the physical test article and a uniaxial hydraulic shake table controlled to imitate different seismic isolation systems at the base of the vessel.

Engineering↗

Theories derived from Haissinski equation and their applications to electron storage rings

As a stationary solution of the Vlasov–Fokker–Planck equation, the Haissinski equation predicts the equilibrium line density of a bunch that circulates in a storage ring for a given wake function. The research in this paper shows that some equations regarding the centroid shift of the bunch, the peak position of the bunch profile, bunch length, and the impedance from the bunch profile can be derived from the Haissinski equation in a self-consistent manner. Specifically, a generalized quadratic equation for potential-well bunch lengthening is derived to accommodate any arbitrary impedance model (that is, the impedance spectrum under consideration can take any form). This expands upon Zotter's cubic equation, which is primarily applicable to inductive impedance. The equations derived in this paper are tested using computed impedance models for some electron storage rings, showing machine-dependent properties of impedance effects. We conclude that these equations can be employed in electron storage rings to effectively bridge the gap between impedance computations and beam-based measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Low Risk of SSR in Type III Wind Turbines Operating in Grid-Forming Control: Preprint

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

Nodal Admittance Matrix Based Area Partition Method for Small-Signal Stability Analysis of Large-Scale Power Electronics Based Power Systems

In power electronics-based power systems (PEPSs), small-signal stability is an important factor for system design and operation, where the impedance-based approach is often used. However, unlike small-scale PEPSs with simple and straightforward impedance models, it would take much more efforts to derive the large-scale PEPSs impedance model, which is very complicated and sometimes may get wrong results due to the elimination of right-half plane (RHP) poles during the impedance aggregation process. To simplify the derivation procedure and analyze the small-signal stability of large-scale PEPSs, this paper proposes a nodal admittance matrix (NAM) based area partition method. In this method, the large-scale PEPS is divided into several sub-areas, and the stability is analyzed within the sub-area first, and then the interconnection stability among these sub-areas is analyzed. The proposed method is scalable and can help to locate the weakest areas/converters that may cause instability in the whole system. In this paper, the concept of the proposed method and its application to an example system are introduced. Experimental results are also given to validate the effectiveness of the proposed method.

Qiao, Liang↗

On the Low Risk of Subsynchronous Resonance (SSR) in Type III Wind Turbines Operating in Grid-Forming Control

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

On the Low Risk of SSR in Type III Wind Turbines Operating with Grid-Forming Control

We have shown in previous work that the risk of subsynchronous resonance between wind power plants with Type III wind turbines and series-compensated transmission lines is low when the wind turbines are operated in grid-forming (GFM) mode instead of the standard grid-following mode. This paper explains the fundamental mechanism behind the improved damping characteristics by modeling the positive- and negative-sequence impedances of Type III wind turbines in GFM control mode. Here it is discovered that the GFM control naturally acts against the negative resistance behavior of Type III wind turbines at subsynchronous frequencies that results from an interaction between the rotor-side converter current controller and negative slip. The developed impedance models in the sequence domain and the improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the impedance response of a 2.5-MW Type III wind turbine in GFM mode.

17 WIND ENERGY↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗