Search NASA⌕ Search

SEARCH · Search NASA

Results for “impulse test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impulse Testing of Corporate-Fed Patch Array Antennas

This paper discusses a novel method for detecting faults in antenna arrays. The method, termed Impulse Testing, was developed for corporate-fed patch arrays where the element is fed by a probe and is shorted at its center. Impulse Testing was devised to supplement conventional microwave measurements in order to quickly verify antenna integrity. The technique relies on exciting each antenna element in turn with a fast pulse (or impulse) that propagates through the feed network to the output port of the antenna. The resulting impulse response is characteristic of the path through the feed network. Using an oscilloscope, a simple amplitude measurement can be made to detect faults. A circuit model of the antenna elements and feed network was constructed to assess various fault scenarios and determine fault-detection thresholds. The experimental setup and impulse measurements for two patch array antennas are presented. Advantages and limitations of the technique are discussed along with applications to other antenna array topologies

antenna array↗

Comparison of Active and Passive Head Impulse Testing of the Horizontal Vestibulo-Ocular Reflex: Exploring the Feasibility of Different Approaches for Spaceflight

INTRODUCTION: Astronauts experience a wide variety of sensorimotor disturbances primarily due to microgravity-induced vestibular adaptations during spaceflight. Head Impulse Testing (HIT) will be conducted during the Complement of Integrated Protocols for Human Exploration Research program(CIPHER) Vestibular Health study to examine changes in the horizontal vestibulo-ocular reflex in response to high-velocity head movements to detect changes in peripheral vestibular function [1,2]. However, correct interpretation will require consideration of potential artifacts and the constraints of conducting this test across different phases of the mission. Therefore, the aims of our study were to (1) examine reliability across different test operators, and (2) compare results of active (aHIT) versus passive (pHIT) approaches to evaluate the feasibility of self-administered versus operator-assisted approaches. A comparison of responses with visual viewing of a wall target (default condition) versus vision occluded evaluated the influence of other oculomotor control influence across conditions, and comparison with computer-generated rotator head impulse tests (rHIT) examined the variability associated with the ocular responses independent of the variability in executing the head movements themselves. METHODS: Seventeen non-astronaut volunteers (male n=12, age=22.9 ± 3.0; female n=5, age=27.0 ± 6.0, mean ± std) completed HIT testing using video-oculography (VOG) goggles and a high-torque rotator system. The test order was counterbalanced across conditions: (1) passive head-on-torso (pHIT, default condition for flight study) using two operators (Op1 and Op2), (2) active head-on-torso (aHIT, subject initiated), and (3) passive head and torso using rotary chair (rHIT). Eye and head movement data were processed to obtain gain in each direction. The main outcome measures were average gain and asymmetry [1], as well as the percentage of acceptable trials not excluded due to insufficient head amplitude or recording artifacts. RESULTS: While the pHIT gains were similar with vision (1.032 ± 0.043) and vision occluded (1.029 ± 0.038) conditions, the percentage of acceptable trials was greater with vision (Op1 = 93.0%, Op2 = 93.2%) versus occluded (Op1 = 70.7%, Op2 = 67.6%). The reliability between operators was greater for pHIT gain (Intraclass Correlation, ICC = 0.66, p = 0.001) than for pHIT asymmetry (ICC = 0.57, p = 0.01). The percentage of acceptable trials reduced by ~20% during the self-administered aHITs for both visual conditions and tended to be lower than computer-generated rHITs (76% versus 83%). While the aHIT gains were not significantly different than pHIT gains for vision or vision occluded conditions, these measures were poorly correlated. Both aHIT and pHIT gains were significantly greater than the rHIT gains, presumably due to the reduced velocities from the rotator. The asymmetry measures were poorly correlated across pHIT, aHIT, and rHIT conditions, although none of the subjects had asymmetries greater than 16%. DISCUSSION: Our findings support the feasibility of using the standard pHIT methodology for spaceflight. Similarities between visual conditions reflect that these responses are mediated by the peripheral lateral canals rather than other oculomotor mechanisms. The inter-tester reliability was acceptable despite differences in the tester training. In addition to concerns of non-vestibular mechanisms introduced during self-administered aHITs [2], operator-assisted pHITs resulted in higher percentage of acceptable trials and should result in more efficient and reliable measures during spaceflight.

M R Ehrenburg↗

Evaluating climate emulation: fundamental impulse testing of simple climate models

Abstract. Simple climate models (SCMs) are numerical representations of the Earth's gas cycles and climate system. SCMs are easy to use and computationally inexpensive, making them an ideal tool in both scientific and decision-making contexts (e.g., complex climate model emulation, parameter estimation experiments, climate metric calculations, and probabilistic analyses). Despite their prolific use, the fundamental responses of SCMs are often not directly characterized. In this study, we use fundamental impulse tests of three chemical species (CO2, CH4, and black carbon – BC) to understand the fundamental gas cycle and climate system responses of several comprehensive (Hector v2.0, MAGICC 5.3, MAGICC 6.0) and idealized (FAIR v1.0, AR5-IR) SCMs. We find that while idealized SCMs are widely used, they fail to capture the magnitude and timescales of global mean climate responses under emissions perturbations, which can produce biased temperature results. Comprehensive SCMs, which have physically based nonlinear forcing and carbon cycle representations, show improved responses compared to idealized SCMs. Even the comprehensive SCMs, however, fail to capture the response timescales to BC emission perturbations seen recently in two general circulation models. Some comprehensive SCMs also generally respond faster than more complex models to a 4×CO2 concentration perturbation, although this was not evident for lower perturbation levels. These results suggest where improvements should be made to SCMs. Further, we demonstrate here a set of fundamental tests that we recommend as a standard evaluation suite for any SCM. Fundamental impulse tests allow users to understand differences in model responses and the impact of model selection on results.

54 ENVIRONMENTAL SCIENCES↗

Minimum impulse tests of 0.45-N liquid hydrazine catalytic thrusters

An exploratory test series was conducted on three types of 0.45-N (0.1 lbf) liquid hydrazine thrusters to ascertain the minimum impulse bit capability for this class of engine. The test series is described and the results are presented. The testing was performed at 21 and 145 C (70 and 300 F) while maintaining nominal 0.45 N (0.1 lbf) upstream conditions. Valve on-times as low as 0.008 sec were applied. Impulse bits were observed for thruster temperatures of 21 and 145 C (70 and 300 F), respectively.

Moynihan, P. I.↗

Project NEO Specific Impulse Testing Solutions

The Neo test stand is currently configured to fire a horizontally mounted rocket motor with up to 6500 lbf thrust. Currently, the Neo test stand can measure flow of liquid propellant and oxidizer, pressures residing in the closed system up to the combustion chamber. The current configuration does not have the ability to provide all data needed to compute specific impulse. This presents three methods to outfit the NEO test fixture with instrumentation allowing for calculation of specific impulse.

oxygen↗

Nondestructive and impulsive testing of electroexplosive devices.

Discussion of NDT techniques and instrumentation developed to demonstrate the quality and normal behavior of 1-W/1-A no-fire electroexplosive devices (EEDs) without firing or degrading the units. Application of these techniques is limited to the bridgewire/explosive/header interface which is considered to be the most critical link in the electroexplosive chain. A certain amount of destructive testing required to determine the sensitivity and output of the EEDs can be accomplished by additional instrumentation that initiates and delivers energy in an impulsive manner with control of pulse width and amplitude.

Menichelli, V. J.↗

An impulse test technique with application to acoustic measurements

A method has been presented for measuring the acoustic properties of an absorbent material and a duct/nozzle system (with or without airflow) using a high voltage spark discharge as an impulse source of sound. The cross-spectra of the incident, reflected and transmitted acoustic pressure transients are analyzed by way of a FFT digital processor in the form of complex transfer functions. These transfer functions have a direct relationship to the termination impedance and radiation directivity. The impulse method has been justified by comparisons, with data obtained from existing methods (both experimental and theoretical), that show excellent agreement. Reflection coefficients and radiation impedances of various duct-nozzle systems and their associated far-field directivities are also presented as some of the applications of the impulse technique.

Salikuddin, M.↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. This paper proposes a holistic impulse-based MOV lifetime estimation framework. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

Staubli TX-90XL robot qualification at the LLIHE.

The Light Initiated High Explosive (LIHE) Facility uses a robotic arm to spray explosive material onto test items for impulse tests. In 2007, the decision was made to replace the existing PUMA 760 robot with the Staubli TX-90XL. A qualification plan was developed and implemented to verify the safe operating conditions and failure modes of the new system. The robot satisfied the safety requirements established in the qualification plan. A performance issue described in this report remains unresolved at the time of this publication. The final readiness review concluded the qualification of this robot at the LIHE facility.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems: Preprint

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. In this paper, a holistic impulse-based MOV lifetime estimation framework is proposed. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

Scramjet testing in impulse facilities

The use of impulse facilities for gas dynamic experimentation on scramjets at high stagnation enthalpies is discussed. It is seen that, although such facilities will produce adequate stagnation enthalpies, it is necessary to compromise somewhat on the requirements for simulating test section densities, in order to allow realistic operating pressure levels. The shock tunnel and the expansion tube are briefly described, before focusing on operation of the reflected shock tunnel. It is shown that test times and flow starting times are such as to allow testing with models of reasonable size, provided that large regions of flow recirculation do not exist. Some examples of experimental scramjet studies, conducted in a reflected shock tunnel, are presented, demonstrating that the reflected shock tunnel is suitable for basic studies of scramjet flow processes. Provided that the effective enhancement of fuel calorific value by free stream 'freezing' of oxygen in the shock tunnel nozzle expansion does not prove to be an insuperable obstacle, the reflected shock tunnel may be expected to provide realistic simulation of scramjet flows up to speeds approaching earth orbital velocity.

Stalker, R. J.↗

Development of Toroidal Core Transformers

The original objective of this project was to design, build and test a few prototypes of single-phase dry-type distribution transformers of 25 kVA, 2.4 kV primary to 120 V transformers using cores made of a continuous steel strip shaped like a doughnut (toroid). At different points during the development of the project, the scope was enhanced to include the more practical case of a 25 kVA transformer for a 13.8 kV primary system voltage. Later, the scope was further expanded to design and build a 50 kVA unit to transformer voltage from 7.62 kV to 2x120 V. This is a common transformer used by Con Edison of New York and they are willing to test it in the field. The project officially started in September 2009 and ended in May 2014. The progress was reported periodically to DOE in eighteen quarterly reports. A Continuation Application was submitted to DOE in June 2010. In May 2011 we have requested a non-cost extension of the project. In December 2011, the Statement of Project Objectives (SOPO) was updated to reflect the real conditions and situation of the project as of 2011. A second Continuation Application was made and funding was approved in 2013 by DOE and the end date was extended to May 2014. The technical challenges that were overcome in this project include: the development of the technology to pass the impulse tests, derive a model for the thermal performance, produce a sound mechanical design, and estimate the inrush current. However, the greatest challenge that we faced during the development of the project was the complications of procuring the necessary parts and materials to build the transformers. The actual manufacturing process is relatively fast, but getting all parts together is a very lengthy process. The main products of this project are two prototypes of toroidal distribution transformers of 7.62 kV (to be used in a 13.8 kV system) to 2x120 V secondary (standard utilization voltage); one is rated at 25 kVA and the other at 50 kVA. The 25 kVA transformer passed the impulse test in KEMA high-voltage laboratories. Additional products include: nine papers published in the IEEE Transactions on Power Delivery, one patent has been filed, three PhD students were supported from beginning to graduation, five postdoctoral fellows, and three MSc students were partially supported. The electrical characteristics of our dry-type toroidal transformers are similar to those of the oil-immersed pole mounted transformers currently in use by many utilities, but toroids have higher efficiency. The no-load losses of the 50 kVA prototype are only 45 W. A standard transformer has no-load losses between 90 and 240 W. Thus, even the finest transformer built today with standard technology has double the amount of no-load losses than the prototype toroidal transformer. When the manufacturing process is prepared for mass production, the cost of a dry-type toroidal transformer would be similar to the price of an oil-filed standard design. However, because of the greatly reduced losses, the total ownership cost of a toroidal transformer could be about half of a traditional design. We got a grant from Power Bridge NY in the amount of $149,985 from June 2014 to May 2015 to continue developing the transformer with commercialization objectives. We are considering the possibility to incorporate a company to manufacture the transformers and have contacted investors. The current status of the real life testing is as follows: after several months of silence, Con Edison has re-started conversations and has shown willingness to test the transformer. Other companies, PSE&G and National Grid have recently also shown interest and we will present our product to them soon.

42 ENGINEERING↗

Summary of Altitude Pulse Testing of a 100-lbf L02/LCH4 Reaction Control Engine

Recently, liquid oxygen-liquid methane (LO2/LCH4) has been considered as a potential "green" propellant alternative for future exploration missions. The Propulsion and Cryogenic Advanced Development (PCAD) project has been tasked by NASA to develop this propulsion combination to enable safe and cost effective exploration missions. To date, limited experience with such combinations exist, and as a result a comprehensive test program is critical to demonstrating the viability of implementing such a system. The NASA Glenn Research Center has conducted a test program of a 100-lbf (445-N) reaction control engine (RCE) at the center s Altitude Combustion Stand (ACS), focusing on altitude testing over a wide variety of operational conditions. The ACS facility includes a unique propellant conditioning feed system (PCFS) which allows precise control of propellant inlet conditions to the engine. Engine performance as a result of these inlet conditions was examined extensively during the test program. This paper is a companion to the previous specific impulse testing paper, and discusses the pulsed mode operation portion of testing, with a focus on minimum impulse bit (I-bit) and repeatable pulse performance. The engine successfully demonstrated target minimum impulse bit performance at all conditions, as well as successful demonstration of repeatable pulse widths. Some anomalous conditions experienced during testing are also discussed, including a double pulse phenomenon which was not noted in previous test programs for this engine.

Marshall, William M.↗