Search NASA⌕ Search

SEARCH · Search NASA

Results for “induction motors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A new tubular ironless linear induction motor using non-interrupted winding method

The ironless linear induction motor device can be used for any application which requires a large motion span or rotation restrictedly by the ironless feature due to the strong magnetic field environment. One of the possible applications is ITER diagnostics shutters. The tokamak reactor systems have a severe radiation issue during the operation. The traditional Kapton-insulated wires have significantly lower radiation resistance than an expected large radiation dose at ITER Motion Stark Effect (MSE) shutter location. Furthermore, the traditional single-sided linear induction motor winds the wire to make the N-turn pitch coils independently and then connect them in series to make a one-phase winding. Therefore, it is a big challenge to make so many radiation-protection connectors in such a limited space as inside the vacuum vessel of fusion reactors. The approved mineral-insulated kinds of cables need a large bend radius for the end turns, so the traditional single-sided linear motor with two-layer three-phase windings need to be upgraded to the tubular linear motors. The new proposed tubular ironless linear induction motor can not only overcome the large bend radius issue with the mineral-insulated cables but also allow the motor coils wound continuously around the tubular-shaped stator, forward and backward N times to make a N-turn winding for each phase, in order to resolve the radiation protection issue with the winding connection. The 3D transient Maxwell electromagnetic model with a tubular three-phase linear induction motor has been analyzed. Furthermore, this paper will present the detailed design and winding method of ironless linear induction motor actuators, and results of the 3D transient numerical simulation of the actuator performance.

Ironless↗

Preliminary Design of Ironless Linear Induction Motors for ITER MSE Shutter Actuators

In this article, the shutters need to be closed or opened during the operation and calibration period time for the fusion diagnostic systems, such as the International Thermonuclear Experimental Reactor (ITER) motional stark effect (MSE). Standard electric motors and actuators will not work in a strong magnetic field environment due to the presence of the magnetic field of fusion reactors. The innovative linear induction motor (LIM) with an ironless feature overcomes this kind of challenge and can be used for any application that requires controlled motion with a large stroke in the magnetic field environment. It consists of a high-electrical conductivity plate like copper and three-phase motor windings with nonferrous or stainless-steel stators. The conductor plate attached with the shutter is simply driven by the underneath three-phase linear windings to achieve linear motion. The motor drive can be controlled remotely by a controller using the electrical connection, so no sensitive electronic components are located in the harsh environment where the motor itself is located. The design requirements and test facility have been described. Several 3-D transient Maxwell electromagnetic (EM) models with different locations of three-phase linear motor windings and shutter stators have been analyzed and evolved to meet any applications allowed in the harsh environment inside the vacuum vessel of fusion reactors. The preliminary design results are presented in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of Induction Motors and Variable Speed Drives for Multi-Domain System Simulations Using Modelica and the OpenIPSL Library

This paper introduces an innovative method for characterizing, implementing, and validating both three-phase and single-phase induction motor models, accompanied by a variable speed drive model. The primary goal is to investigate interactions between the electrical power grid and other dynamic domains (e.g., thermofluidic) that impact motor/load drive behavior. Our approach involves establishing a mechanical interface based on a physically meaningful equation linking motor torque/speed to the electrical model in the phasor domain. This allows seamless integration of diverse domain subsystems into a unified multi-domain model using Modelica v4.0.0 and the OpenIPSL library v3.0.1, overcoming co-simulation limitations. The proposed model, which requires only one Modelica-compliant tool for simulation, introduces additional dynamics through the mechanical interface, enabling explicit simulation of load disturbances based on constitutive physics. This deepens our understanding of dynamic interactions between the electrical power domain and other subsystems connected through the motor. We detail the modeled components using mathematical equations and textual descriptions, emphasizing the Modelica modeling approach. Simulation examples validate the implementation, demonstrating the multi-domain modeling capabilities of the newly developed components.

Computer Science↗

Data Challenges for Structural Health Monitoring of Electrical Machines [Slides]

Induction motors (ID) consist of a stator and a rotor. Induction motor slip decreases with decreasing load. Induction motor slip decreases with decreasing load. This talk will focus on removing closely coupled power grid frequencies in an effort to observe the true dynamic response signature of induction motors. Using the time difference between the zeros, we found the frequency as it changes over time for each of the 3 phases. The frequencies of the 3 phases were averaged to reduce the effects of sidebands on the instantaneous frequency. The frequencies of the 3 phases were averaged to reduce the effects of sidebands on the instantaneous frequency. The Kalman filter rapidly synchronizes with the expected output. The sidebands were recreated using spectral subtraction. The frequency domain shows the reduction in magnitude of the power grid frequency the Kalman output was subtracted out. Kalman filtering also reveals important data about the sidebands in healthy motors. The Continuous Wavelet Transform is an alternative to a Bandpass IIR filter used in the analysis of the acceleration data. Analysis of the acceleration data reveals 4 sidebands around the slip frequency.

42 ENGINEERING↗

SMC Reinforced by Recycled or Textile Carbon Fiber

There is a significant need to expand material options for SMC that has traditionally used glass fibers for decades. There are several integral issues related to chopping and conveying a range of materials including glass, carbon, basalt, thermoplastic tapes, and recycled fibers. These are in a variety of forms including continuous tows, discontinuous agglomerates such as pyrolyzed carbon fibers that could be used to produce a range of SMC intermediates. Standard/conventional SMC processing is limited to cutting rotors specifically for glass and compounding with thermoset polyesters and some epoxies. The multi-material, multi-format line developed in this project is flexible to enable custom conveying and uses an interchangeable rotor dedicated for specific material types. The overall tasks undertaken in this project included: evaluation of the fiber feed mechanism, effect of textile grade carbon, evaluating servo motor controlling of conveyor, evaluate doctor box resin feed, evaluate compaction unit, evaluation of different formulations, and develop automation such as PLC programming. The new multi-material SMC line Version 2 (SCM-V2) incorporated servo motors over induction motors which gave the overall cutter system precision control and made it quiet. The addition of a 14-roll compaction unit at the end of the line in SMC-V2 enabled higher material wet out which was a limitation in the SMC Version 1 (SMC-V1). The cutters were further updated to reduce the cantilever overhang of the fiber which enabled more uniform cut lengths for glass, carbon, and basalt fibers. The overall instrumentation and system control including a remote control operation was enabled in the SMC-V2. The line speed is capable of 10-20 ft/minute. The cutting modules were designed and engineered for cutting glass, basalt and textile grade carbon in 300k and 450-600k format widths. The cutting trials were established for a range of fiber types. The study also demonstrated the utility of the line to cut and produce basalt fiber SMC. Initial trials were conducted on the properties from recycled carbon fiber (rCF) mats in epoxy resin. Overall, the Covid19 situation constrained the team from accessing the SMC line for over 18 months. Despite this challenge major advancements were made.

36 MATERIALS SCIENCE↗

Performance Characterization and Energy Savings Assessment of a Radial Flux Surface Permanent Magnet Motor Technology

This project is part of the National Renewable Energy Laboratory's (NREL's) "Commercialization Assistance Program" to provide technical expertise to help emerging companies overcome technical barriers to commercialization. In this study, NREL has evaluated the efficiency and energy saving potential of a novel motor technology designed by ZEUS Motor Inc. located in Wheat Ridge, Colorado. The motor expands on permanent magnet AC motor (PMAC) design to create a new "radial flux, surface PMAC", or RF-sPMAC motor that is expected to outperform other novel motor technologies on the market. Here, the motor showed considerable energy benefits over typical induction motors. The motor benefits from a tightly-packed magnetic steel and copper stator that allows the motor size to be reduced to a thin disc with an internal cavity 1/30th the size of a traditional induction motor. The housing is also aluminum which is magnetically benign. This eliminates the need for external cooling (up to 25 HP), in addition to reducing power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing impact of $\mathrm{DER}$ on $\mathrm{FIDVR}$ - comparison of $\mathrm{EMT}$ simulation of a combined transmission and distribution grid with aggregated positive sequence models

The increase in percentage of distributed energy resources (DERs) brings in a degree of uncertainty in bulk power system planning and operations. Further, the presence of 1 - φ induction motors introduces the possibility of motor stalling and fault induced delayed voltage recovery (FIDVR). With newer versions of IEEE Std 1547™ there can be the opportunity to obtain dynamic voltage support from DERs. In this report, the impact of DERs providing dynamic voltage on the dynamic behavior of 1 - φ induction motors is examined in detail along with an exploration of the need for simulation platforms that go beyond positive sequence. The studies discussed here are carried out both in detailed electromagnetic time domain and in positive sequence domain for comparison.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parameter Reduction of Composite Load Model Using Active Subspace Method

Over the past decades, the increasing penetration of distributed energy resources (DERs) has dramatically changed the power load composition in the distribution networks. The traditional static and dynamic load models can hardly capture the dynamic behavior of modern loads especially for fault-induced delayed voltage recovery (FIDVR) events. Thus, a more comprehensive composite load model with combination of static load, different types of induction motors, single-phase A/C motor, electronic load and DERs has been proposed by Western Electricity Coordinating Council (WECC). However, due to the large number of parameters and model complexity, the WECC composite load model (WECC CMLD) raises new challenges to power system studies. To overcome these challenges, in this paper, a cutting-edge parameter reduction (PR) approach for WECC CMLD based on active subspace method (ASM) is proposed. Firstly, the WECC CMLD is parameterized in a discrete-time manner for the application of the proposed method. Then, parameter sensitivities are calculated by discovering the active subspace, which is a lower-dimensional linear subspace of the parameter space of WECC CMLD in which the dynamic response is most sensitive. The interdependency among parameters can be taken into consideration by our approach. Finally, the numerical experiments validate the effectiveness and advantages of the proposed approach for WECC CMLD model.

active subspace↗

Industrial Conveyor Motor Performance Evaluation

The purpose of this project is to estimate the energy savings potential from a switched-reluctance motor (SRM) compared to an induction motor equipped with variable frequency drive (VFD) in a straight belt conveyor application. To experimentally evaluate savings in a realistic scenario, a baseline motor and VFD were selected from one of ComEd’s manufacturing customers’ conveyor systems. It was desired to not only estimate savings in the selected conveyor system, but to evaluate potential savings from using the SRM in any straight belt conveyor. Therefore, NREL developed a conveyor system energy calculation tool to supplement the experimental results of this assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sorting rare earth magnets motors for recycling without opening the motors

Abstract A novel approach for sorting electric motors without dismantling them is reported in this article. This approach increases the likelihood that a motor selected from a mixture for recycling would contain rare earth elements (REEs), which are pivotal for numerous advanced green technologies. The challenge of inadvertently dismantling motors without REEs during recycling is addressed by this proposed innovative method. It relies on cogging interactions and power density for sorting motors with REEs. The process uses an algorithm introduced in this work to sort motors in two steps by (a) distinguishing induction motors from permanent magnet motors, and (b) distinguishing motors with critical REEs (e.g., Nd, Pr, Dy, Tb) from ferrite-based motors, all without opening the motors. The former was accomplished with 100% accuracy while the latter was accomplished with ~ 78% accuracy. Such high accuracy improves the recycling efficiency of critical REEs from motors, alleviating concern about supply disruption and supporting resource conservation and sustainability.

36 MATERIALS SCIENCE↗

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Speed Hybrid Reluctance Motor Utilizing Anisotropic Materials

With high cost and volatility driving continued efforts to decrease reliance on the critical heavy rare earth materials used in traction drive applications, General Motors developed three variants of heavy rare earth-free (HRE-free) electric motors. The variants focused on taking advantage of advanced magnet technologies and new rotor topologies to improve mechanical strength and achieve power targets. The three variants were a HRE-free permanent magnet reluctance motor, a synchronous reluctance motor utilizing small HRE-free permanent magnets, and an induction motor with inserted copper bars and cast aluminum end-rings. Motors were designed with the intent of primary or secondary traction applications, depending on the topology. Variant 1 achieved performance comparable to HRE-containing permanent magnet motors through optimized topology and validation of HRE-free magnets, focusing on achieving energy products and demagnetization resistance comparable to those of HRE-containing magnets. Demagnetization testing demonstrated the motor robustness to currents and temperatures exceeding expected vehicle conditions, a key challenge to the use of HRE-free magnets. The Variant 1 motor also showed the best capability of meeting the US Drive technology 2020 targets, due to the high power-density of the permanent magnet motor and the potential cost reductions enabled by the removal of heavy rare earth materials. Variant 2 exhibited high efficiency in high speed regions due to the low high-speed losses, an important consideration for secondary traction applications, and significantly thrifted on magnet mass to reduce cost. Variant 3 contained copper bars within the induction rotor to reduce losses compared to cast aluminum, while using cast aluminum end-rings to reduce the cost and mass of the rotor. Optimization of the Cu-Al interface were focused on, as the interface is prone to forming brittle intermetallic compounds during the casting process. Prototypes of each motor variant were built and tested for performance, mechanical strength, and demagnetization resistance (Variants 1 and 2 only), with torque and power resulting close to the predicted values.

33 ADVANCED PROPULSION SYSTEMS↗

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

Enhanced Performance of Dual Inverter with a Floating Capacitor for Motor Drive Applications

This paper studies a dual inverter supplied by a DC-link and a floating capacitor (FC), emerged as a promising inverter topology for motor drive applications. For this type of inverter, the voltage ratio between the DC-link and the FC can be actively controlled. This ratio design is crucial as it essentially defines both the DC-link voltage utilization and the inverter output quality. Several voltage ratios have previously been discussed to enhance the dual inverter performance, but only one aspect, either the voltage utilization or the output quality, is investigated. As a result, although one performance aspect can be improved, the other aspect has been adversely affected. In this work, a comparative study considering both aspects is carried out for all the possible voltage ratios. Based on this analysis, the optimal ratios for different inverter modulation indices are identified. This is followed by proposing a ratio selection strategy to double the voltage utilization without degrading the output quality. Furthermore, this strategy enables an electric drive to work at a higher maximum speed without flux weakening for a given DC-link voltage. The claimed advantages have been proved by experimental tests on an open-end windings induction motor drive.

42 ENGINEERING↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗