Search NASASearch

SEARCH · Search NASA

Results for “interlaboratory study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Results of an interlaboratory study on the working curve in vat photopolymerization II: Towards a standardized method

The working curve measurement in photopolymer additive manufacturing is a ubiquitous measure of the cure depth of a printing resin as a function of radiant exposure of light. The fit parameters from this measurement (the depth of light penetration D p and the critical exposure E c ) are used to evaluate and report a resin’s printability, optimize processing parameters, and inform print and resin quality control. Despite its widespread use, the working curve lacks a standard measurement method. Here, following up on our paper “Results of an Interlaboratory Study on the Working Curve in Vat Photopolymerization” from last year, an interlaboratory study on the working curve was performed using calibrated, reproducible, bandpass filtered light sources. With these light sources, the variability between labs in measured working curves was dramatically reduced from the initial interlaboratory study. Aggregate data from this experiment produced reliable D p and E c measurements at 385 nm of 39.2 ± 3.7 µm and 12.3 ± 3.0 mJ cm −2 , respectively. At 405 nm the values of D p and E c are 69.3 ± 3.8 µm and 17.9 ± 2.3 mJ cm −2 , respectively. The results are agnostic to the thickness measurement tool utilized by participants, ensuring broad applicability across laboratories. We also tested the generalizability of the proposed method of using a filtered light source by filtering a commercial 405 nm light source and obtaining a working curve in agreement with the aggregate data from the interlaboratory study. This interlaboratory study provides a basis for a documentary standard for the working curve, so that the entire photopolymer additive manufacturing industry can share reproducible and interoperable working curve data.

36 MATERIALS SCIENCE

Component Identification of Solid Biomass Fuels Using Reflected Light Microscopy: Interlaboratory Study 2

As nations transition toward sustainable energy systems, biomass has become a vital component of global energy portfolios. Derived from organic materials such as wood, agricultural residues, forestry byproducts, and organic waste, biomass is a renewable energy source with significant environmental and economic benefits. Responsible biomass energy production can improve waste management, reduce emissions of greenhouse gases, and mitigate environmental pollution. However, as the diversity of biomass-derived fuels increases, robust quality assessment methods are essential to ensure their efficiency, safety, and minimal environmental impact. Reflected light microscopy (RLM) is one such technique with the potential to complement conventional physico-chemical analyses by enabling a rapid identification of material constituents and impurities. To refine this methodology and evaluate the reproducibility of solid biomass component identification using RLM, an interlaboratory study (ILS) was conducted. The study involved the recognition of 58 components across 45 photomicrographs, with the participation of 65 scientists and students from 25 countries. The participants faced high difficulty identifying some of the marked components, and as a result, the percentage of correct answers ranged from 19.0 % to 98.3 %, with an average correct identification rate of 62.7 %. The most challenging aspects of the identification process included distinguishing between woody and non-woody (agro) biomass, accurately identifying petroleum-derived materials, and differentiating agro biomass from inorganic matter. The results suggest that while RLM is an important tool for characterizing solid biomass, further development of methodology guidelines and training are necessary to enhance its effectiveness. Future research should prioritize preparing detailed, image-rich, microscopic morphological descriptions of biomass fuel components, which could improve the accuracy and reliability of using RLM in biomass fuel characterization.

09 BIOMASS FUELS

The development and application of the stirred‐reactor coupon analysis (SRCA) test method

A new technique, termed the stirred‐reactor coupon analysis (SRCA) method, has been developed to measure the rate of glass dissolution in forward‐rate conditions. Monolithic glass coupons are partially masked with an inert material before placement in a large volume of well‐mixed solution with known chemistry and temperature for a predetermined duration. After the test, the mask is removed, and the difference in step height between the protected area and the exposed corroded portions of the sample coupon is measured to determine the extent of glass dissolution. The step height is converted to a rate measurement using the test duration and glass density. Test parameters such as sample surface preparation and test duration were evaluated to determine their effects on the measured rates. Additionally, results from an interlaboratory study (ILS) consisting of 12 laboratories from 11 different institutions are presented, where each laboratory performed 12 independent tests. When removing experimental outlier data, the 95% reproducibility limits for the SRCA method has no statistical difference with previously published standardized test methods used to determine the forward rate of glass dissolution. Overall, this paper describes steps necessary to perform the test method and provides the statistical calculations to evaluate test accuracy.

chemical durability

A large interlaboratory electron diffraction study of monolayer graphene

Standardisation of data collection and analysis is essential to enable commercialisation of 2D materials in a wide range of technologies. Selected area electron diffraction (SAED) in the transmission electron microscope (TEM) is one of the key methods for distinguishing monolayer from bilayer and few-layer graphene by comparing the 1st and 2nd order diffraction spot intensities. Yet there are many factors that can affect the reliability of data collection and interpretation, causing the measurement of monolayer samples to deviate from the literature boundary condition of $I_{\{\bar{2}110\}}$$/$$I_{\{1\bar{1}00\}}$ < 1 for monolayer graphene (1LG). Here we present the results of a large interlaboratory SAED comparison study, where 15 international laboratories measured and analysed nominally identical samples of chemical vapour deposited graphene. Large variations were observed in the measured ratios of diffraction spot intensities, with the largest variance associated with poor quality SAED data resulting from inadequate specimen handling and storage. To inform the reliable determination of monolayer thickness from SAED patterns we provide a description of best practice for specimen handling, TEM operation, data collection and analysis. This work was undertaken within VAMAS Technical Working Area 41: Graphene and related 2D materials—Project 9, the results of which have been directly incorporated into ISO/TS 21356–2 for the characterisation of graphene sheets. We find that when this methodology is followed, 1LG can be distinguished from bilayer or thicker material with high confidence where analysis of a single SAED pattern gives $I_{\{\bar{2}110\}}$$/$$I_{\{1\bar{1}00\}}$ < 1.2, even in the absence of precise specimen tilting.

2D materials

Round-robin analysis of highly depleted lithium for Generation IV nuclear reactor applications

Lithium reference materials containing unnaturally high abundances of 7 Li are not currently available, which poses quality control problems for highly depleted lithium materials (i.e., depleted in 6 Li) required for Generation IV nuclear reactors. This study presents an interlaboratory comparison of a lithium carbonate (NIST SRM924a) containing nominally natural isotopic abundances (~92.4 % Li-7) and a highly depleted lithium hydroxide material (~99.95 % Li-7). The natural lithium isotope abundances of NIST SRM924a are confirmed, and the 6 Li/ 7 Li ratio of the lithium hydroxide ranged from 0.000399 to 0.000436 with an average of 0.000428 ± 0.000023 (2SD, n = 9). Finally, going forward this material can be used as quality control for analytical work involving highly depleted lithium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Radiochronometric discordance in cast uranium metal: a multi-laboratory intercomparison exercise

Here, the model age of a nuclear material is crucial in nuclear forensic analysis. Uranium metals with complex production histories often exhibit discordant model ages from the 230 Th– 234 U and 231 Pa– 235 U chronometers. Recent studies involving targeted uranium metal castings have enhanced our understanding of decay product behavior during casting, aiding nuclear forensic interpretation. Building on this prior work, forensics laboratories at Atomic Weapons Establishment (AWE), Lawrence Livermore National Laboratory (LLNL), and Los Alamos National Laboratory (LANL) conducted an interlaboratory comparison to investigate spatial heterogeneity in uranium metal cast under controlled conditions. Each laboratory measured samples of a mixed feedstock and its corresponding cast product. This work furthers our understanding of discordant model ages and the use of discordance as a signature to enhance confidence in interpretations of radiochronometric data for nuclear forensics.

230Th/234U