At least 19 records

Inverter Reliability Estimation for Advanced Inverter Functionality

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous modes, which will produce new stresses on the grid-interfacing power electronics components, such as DC/AC inverters. In previous work, multiple DER devices were instrumented to evaluate additional component stress under multiple reactive power setpoints. We utilize quasi-static time-series simulations to determine voltage-reactive power mode (volt-var) mission profile of inverters in an active power system. Mission profiles and loss estimates are then combined to estimate the reduction of the useful life of inverters from different reactive power profiles. It was found that the average lifetime reduction was approximately 0.15% for an inverter between standard unity power factor operation and the IEEE 1547 default volt-var curve based on thermal damage due to switching in the power transistors. For an inverter with an expected 20-year lifetime, the 1547 volt-var curve would reduce the expected life of the device by 12 days. This framework for determining an inverter's useful life from experimental and modeling data can be applied to any failure mechanism and advanced inverter operation.

component degradation↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

2024 Photovoltaic Inverter Reliability Workshop Summary Report & Proceedings

The National Renewable Energy Laboratory (NREL) organized the 2024 Photovoltaic Inverter Reliability Workshop on April 11-12, 2024, hosted at NREL's South Table Mountain campus in Golden, Colorado. The workshop was organized around seven key topics, including the present state of inverter reliability; solutions for reliability challenges; life cycle cost and ownership issues; testing, standards, performance, and reliability metrics; data reporting, analytics, and sharing; and the future of PV inverter reliability research. Participants included inverter manufacturers, national laboratory researchers, academics, independent testing laboratories, and more. Over the course of the two-day workshop, attendees arrived at several key priorities and conclusions. This report summarizes these conclusions and then collects presentations from the workshop into a record of the workshop's proceedings.

14 SOLAR ENERGY↗

Enhancing PV Inverter Reliability Through Predictive Maintenance: Insights from Retrofitting of PV Inverters

Photovoltaic (PV) systems represent a cornerstone in the global shift toward sustainable energy generation, with inverters serving as the crucial link between solar panels and the grid. Despite their pivotal role, inverters are susceptible to failures, contributing significantly to maintenance events and operational disruptions in large-scale PV plants. This white paper investigates the importance and methodologies of predictive maintenance strategies that monitor the component-level pre-failure signatures on PV inverters. Through a comprehensive survey of literature and industry professionals, insights on preventive maintenance and retrofitting practices have been gathered. The expert elicitation helps shed light on common challenges and opportunities for improving PV system reliability, particularly inverter reliability. By addressing these challenges, the white paper aims to enhance the long-term viability and effectiveness of solar PV plants in the renewable energy landscape, contributing to the global transition toward environmentally friendly energy generation.

14 SOLAR ENERGY↗

Utility-scale grid-tied PV inverter reliability workshop summary report.

A key to the long-term success of the photovoltaic (PV) industry is confidence in the reliability of PV systems. Inverters are the most commonly noted cause of PV system incidents triggered in the field. While not all of these incidents are reliability-related or even necessarily failures, they still result in a loss of generated power. With support from the U.S. Department of Energy's Solar Energy Technologies Program, Sandia National Laboratories organized a Utility-Scale Grid-Tied Inverter Reliability Workshop in Albuquerque, New Mexico, January 27-28, 2011. The workshop addressed the reliability of large (100-kilowatt+) grid-tied inverters and the implications when such inverters fail, evaluated inverter codes and standards, and provided discussion about opportunities to enhance inverter reliability. This report summarizes discussions and presentations from the workshop and identifies opportunities for future efforts.

14 SOLAR ENERGY↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

For predicting the reliability and lifetime of Photovoltaic (PV) inverters, thermal cycling is considered the most important stressors in the inverter system. To realize this, a detailed electrothermal model of the PV inverter was developed along with the controllers. The model was verified by developing an in-house inverter, which was placed inside a thermal chamber to verify the losses and temperature rise within the system at various temperatures. After the verification of the model, a reduced order model of the inverter was implemented which can translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The estimated junction temperature data was used to identify the reliability indices and predict the useful lifetime of the inverter system. After developing the models to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system was studied. Experiments show that lifetime and reliability of the inverter decreases as the operating power factor decreases from unity. The results are presented and discussed here.

14 SOLAR ENERGY↗

Photovoltaic Inverter Reliability Assessment

As the price of PV modules drops, the price of power electronics become more important. Power electronics now constitute 8%-12% of the total lifetime PV cost. As of 2010, the inverter and associated power conditioning components accounted for $\$0.25$/W, well above the DOE benchmark of $\$0.12$/W by 2020. As efforts to reduce PV module costs yield diminishing returns, the importance of understanding and reducing inverter costs becomes an increasingly critical and cost-effective investment toward achieving the DOE SunShot goals. With this in view, this report showcases and describes an approach to help assess and predict the reliability of photovoltaic (PV) inverters. To predict the reliability, thermal cycling is considered as a prominent stressor in the inverter system. To evaluate the impacts of thermal cycling, a detailed linearized model of the PV inverter is developed along with controllers. This research also develops models and methods to compute the losses of the power electronics switches and other components in a PV inverter. The losses are then used to estimate the junction and heat sink temperature. The model is verified by developing an in-house inverter. Additionally, to assess the scalability of the research, the hardware inverter is placed inside a thermal chamber to verify the losses for different ambient temperatures. After the verification of the model, a reduced-order model of the inverter is implemented to translate the profile of ambient temperature and solar irradiance into the profile of junction temperatures of the switches. The estimated junction temperature data are used to identify inverter reliability indices and predict the useful lifetime of the inverter system. After developing the models to predict the useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The first chapter involves the motivation behind the research on assessing the reliability of PV inverters. The inverter power stage and controller design of the power converter used in this research is also explained in detail in this chapter. The second chapter presents the various losses of the power converter system and the translation of power loss into temperature increase with thermal modeling. The results of the loss modeling and the thermal modeling are also explained in detail in this chapter. The third chapter involves implementing the reduced-order model to translate the mission profile of ambient temperature and solar irradiance into profile of the junction temperatures of the switches. The final chapter involves identifying reliability indices, which are of interest for this system to predict the remaining useful life of the system, and concludes with the impact of reactive power on the overall reliability of the inverter system.

14 SOLAR ENERGY↗

Automating Component-Level Stress Measurements for Inverter Reliability Estimation

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous operating modes which induce new stresses on the power electronics components. In this work, an experimental and theoretical framework is introduced which couples laboratory-measured component stress with advanced inverter functionality and derives a reduction in useful lifetime based on an applicable reliability model. Multiple DER devices were instrumented to calculate the additional component stress under multiple reactive power setpoints to estimate associated DER lifetime reductions. A clear increase in switch loss was demonstrated as a function of irradiance level and power factor. This is replicated in the system-level efficiency measurements, although magnitudes were different—suggesting other loss mechanisms exist. Using an approximate Arrhenius thermal model for the switches, the experimental data indicate a lifetime reduction of 1.5% when operating the inverter at 0.85 PF—compared to unity PF—assuming the DER failure mechanism thermally driven within the H-bridge. If other failure mechanisms are discovered for a set of power electronics devices, this testing and calculation framework can easily be tailored to those failure mechanisms.

Flicker, Jack (ORCID:0000000212232154)↗

Design and Implementation of Automated Characterization of T-type based Power Module for PV Inverter Reliability Assessment

Reliability of power electronics holds the key for future power and energy systems since it is essential for system integration with renewables and energy storage systems. Variation of power module characteristics over the converter’s operational lifetime is a critical indicator to assess its reliability. Device characterization consists of different steps to collect, process, and visualize results, which is usually time-consuming, especially for power modules based on a non-phase-leg configuration, such as T-type circuits, widely applied for PV inverters. To reduce the time, ensure repeatability, and guarantee consistency, an automated test bench can be helpful. This paper focuses on a T-type-based power module and proposes a unique characterization platform and corresponding automation procedure and implementation. Considering the major characterization difference between T-type power modules over the conventional phase-leg power module, first, the special consideration for static characterization is highlighted. Second, the unique dynamic characterization design associated with the T-type power module is described. Finally, the automation of the power module characterization and the test platform is presented along with results and special considerations.

Siraj, Ahmed↗

Reliable inverter systems

Base driver with common-load-current feedback protects paralleled inverter systems from open or short circuits. Circuit eliminates total system oscillation that can occur in conventional inverters because of open circuit in primary transformer winding. Common feedback signal produced by functioning modules forces operating frequency of failed module to coincide with clock drive so module resumes normal operating frequency in spite of open circuit.

Nagano, S.↗