Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Raman Scattering Studies in Dilute Magnetic Semiconductor Zn(1-x)Co(x)O

Raman spectra of ZnO and Co substituted Zn1-xCoxO (ZCO) were carried out using the Raman microprobe system with an p.,+ ion laser source of 514.5 nm wavelength. The shift towards the lower frequency side of the nonpolar E210w mode and the broadening due to Co substitution in ZnO were analyzed using the phonon confinement model. The magnetic measurements showed ferromagnetic behavior with the maximum saturation magnetization (1.2micron Beta/ErCo) for 10% Co substitution, which decreased wi th at further increase in Co concentrations. The intensities of E1(LO) at 584 cm-1 and multiphonon modes at 540 cm-1 were increased with an increase in Co substitution. The additional Raman modes in ceramic targets of ZCO spectra for higher concentration of Co substitution (x=15%-20%) were identified to be due to the spinel ZnCo2O4 secondary phase.

Samanta, K.↗

CARS measurement of velocity in a supersonic jet

It is shown that CW CARS can be used to measure velocity in supersonic flows. The accuracy with which the Doppler shift can be measured is determined through the drift in the laser frequencies. In the experiment described here, it is found that a laser drift error of 10 MHz during the recording of a spectrum would limit the velocity resolution to 34 m/s. It is noted that improved frequency stabilization of the laser sources could lead to a velocity measurement accuracy of several m/s. In the experiment, a 4-W single axial mode argon ion laser is the pump source, and the Stokes-shifted frequency is generated by a 100-mW tunable dye laser.

Gustafson, E. K.↗

Single-Event-Upset Laser Scanner With Optical Bias

Light-assisted microelectronic advanced laser scanner (LAMEALS) is augmented version of microelectronic advanced laser scanner (MEALS) described in article, "Laser Scanner Tests For Single-Event Upsets", (NPO-18216). Only major difference, steady illumination from helium/neon laser, argon-ion laser, and/or other source(s) combined with pulsed dye-laser illumination of MEALS into single illuminating beam.

Kim, Quiesup↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused X-ray, pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.

Heavy ions↗

Nonpropulsive applications of ion beams

Eight centimeter ion beam sources utilizing xenon and argon have been developed that operate over a wide range of beam energies and currents. Three types of processes have been studied: sputter deposition, ion beam machining, and ion beam surface texturing. The broad range of source operating conditions allows optimum sputter deposition of various materials. An ion beam source was used to ion mill laser reflection holograms using photoresist patterns on silicon. Ion beam texturing was tried with many materials and has a multitude of potential applications.

Hudson, W. R.↗

OH radical measurements by optical absorption spectroscopy

The long path absorption spectroscopy (LPA) measurement of OH utilizes the strong UV absorption spectrum of the molecule with well resolved rotational lines around 308 nm. The light source consists of an Ar ion laser pumped CW dye laser, the output of which is frequency doubled to emit a spectrally smooth light profile of 0.1 nm FWHM at 308 nm. This is considerably broader than the sharp (0.0018 nm wide) absorption features of OH and also wider than the total spectral region (0.06 nm) scanned around the OH lines. For field measurements a Cassegrain-type telescope expands the small diameter of the original laser beam by a factor of 50 to about a 0.25-m diameter in order to reduce the divergence of the beam as well as its mean photon flux density, thus reducing the maximum self-generated OH concentration to 40,000 cu. cm. The light is passed into the open atmosphere and reflected at about 5 km distance resulting in a 10-km light path length. A telescope focuses the returning light onto the entrance slit of a monochromator the single exit slit of which is replaced by a mechanical scanning device operating at a scan repetition rate of 6.6 KHz. For a typical measurement (1h duration) some 20,000,000 scans are averaged, rendering the contribution of atmospheric turbulence to the spectral noise negligible.

Platt, U.↗

Flashlamp-pumped Ho:Tm:Cr:LuAG laser

A room temperature solid-state laser is provided. A laser crystal is disposed in a laser cavity. The laser crystal has a LuAG host material doped with a concentration of about 0.35% Ho ions, about 5.57% Tm ions and at least about 1.01% Cr ions. A broadband energizing source such as a flashlamp is disposed transversely to the laser crystal to energize the Ho ions, Tm ions and Cr ions.

Jani, Mahendra G.↗

Apparatus for extraction and separation of a preferentially photo-dissociated molecular isotope into positive and negative ions by means of an electric field

Molecules of one and the same isotope were preferentially photodissociated by a laser and an ultraviolet source, or by multiphoton absorption of laser radiation. The resultant ions were confined with a magnetic field, moved in opposite directions by an electric field, extracted from the photodissociation region by means of screening and accelerating grids, and collected in ducts.

Wilhelm, H. E.↗

Comparison of the bidirectional reflectance distribution function of various surfaces

Described is the development and use of a system to measure the Bidirectional Reflectance Distribution Function (BRDF) of various surfaces. The BRDF measurements are used in the analysis and design of optical measurement systems, such as laser anemometers. An argon ion laser (514 nm) is the light source. Preliminary results are presented for eight samples: two glossy black paints, two flat black paints, black glass, sand blasted aluminum, unworked aluminum, and a white paint. A BaSO4 white reflectance standard was used as the reference sample throughout the tests. The reflectance characteristics of these surfaces are compared.

Fernandez, Rene↗

Comparison of the bidirectional reflectance distribution function of various surfaces

This paper describes the development and use of a system to measure the bidirectional reflectance distribution function (BRDF) of various surfaces. The BRDF measurements are to be used in the analysis and design of optical measurement systems such as laser anemometers. An Ar-ion laser (514 nm) was the light source. Preliminary results are presented for eight samples: two glossy black paints, two flat black paints, black glass, sand-blasted Al, unworked Al, and a white paint. A BaSO4 white reflectance standard was used as the reference sample throughout the tests.

Fernandez, Rene↗

Mechanisms for Pole Piece Erosion in a 6-kW Magnetically-Shielded Hall Thruster

The mechanisms contributing to the erosion of the inner magnetic pole of a 6-kW magnetically shielded Hall thruster are experimentally and numerically investigated. Sputtering from ion bombardment is believed to be the cause of this wear, but the nature and source of the responsible ions remains unknown. Laser induced fluorescence and translating and surface-mounted probes are employed to characterize the flux and energy distribution of ions incident at the inner pole. It is found that the bulk population is comprised of ions originating from the cathode plume and the near field immediately adjacent to the inner pole. These ions have a low average kinetic energy, < 5 eV kinetic, but a high thermal spread in velocity, Ti = 10 eV. Calculations for the erosion at the pole from experimental measurements indicate that the bulk population only accounts for 10-25% of the observed erosion. It is postulated that the remainder of the erosion results from a separate population of ions with sufficiently high energy (> 150 V) to cause high sputtering but too low density to be detected experimentally by the plasma diagnostics in this region. The existence for this high energy population is shown to be a consequence of the high plasma potentials downstream of the thruster exit plane that are characteristic of a magnetically-shielded topography. A simulation validated by experimental measurements of the thruster provides further evidence that a high energy ion populations exists with sufficient density to explain the observed erosion.

Jorns, Benjamin A.↗

Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Source Design and Performance Characterization

The Mars Organic Molecule Analyzer (MOMA), a dual-source, ion trap-based instrument capable of both pyrolysis-gas chromatography mass spectrometry (pyr/GC-MS) and laser desorption/ionization mass spectrometry (LDI-MS), is the core astrobiology investigation on the ExoMars rover. The MOMA instrument will be the first spaceflight mass analyzer to exploit the LDI technique to detect refractory organic compounds and characterize host mineralogy; this mode of analysis will be conducted at Mars ambient conditions. In order to achieve high performance in the Martian environment while keeping the instrument compact and low power, a number of innovative designs and components have been implemented for MOMA. These include a miniaturized linear ion trap (LIT), a fast actuating aperture valve with ion inlet tube, and a Microelectromechanical System (MEMS) Pirani sensor. Advanced analytical capabilities like Stored Waveform Inverse Fourier Transform (SWIFT) for selected ion ejection and tandem mass spectrometry (MS/MS) are realized in LDI-MS mode, and enable the isolation and enhancement of specific mass ranges and structural analysis, respectively. We report here the technical details of these instrument components as well as system-level analytical capabilities, and we review the applications of this technology to Mars and other high-priority targets of planetary exploration.

Xiang Li↗

Nonpropulsive applications of ion beams

This paper describes the results of an investigation of the nonpropulsive applications of electric propulsion technology. Eight centimeter ion beam sources utilizing xenon and argon have been developed that operate over a wide range of beam energies and currents. Three types of processes have been studied - sputter deposition, ion beam machining, and ion beam surface texturing. The broad range of source operating conditions allows optimum sputter deposition of various materials. An ion beam source has also been used to ion mill laser reflection holograms using photoresist patterns on silicon. Ion beam texturing has been tried with many materials and has a multitude of potential applications.

Hudson, W. R.↗

A new mass spectrometer system for investigating laser-induced vaporization phenomena

A laser has been combined with a mass spectrometer in a new configuration developed for studies of high-temperature materials. A vacuum-lock, solid-sample inlet is mounted at one end of a cylindrical, high-vacuum chamber one meter in length with a nude ion-source, time-of-flight mass spectrometer at the opposite end. The samples are positioned along the axis of the chamber at distances up to one meter from the ion source, and their surfaces are vaporized by a pulsed laser beam entering via windows on one side of the chamber. The instrumentation along with its capabilities is described, and results from laser-induced vaporization of several graphites are presented.

Lincoln, K. A.↗

Mestastable State Population in Laser Induced Plasmas

Laser induced plasma has been used as a source of neutrals and ions in the study of astrophysical plasmas. The purity of state of this source is essential in the determination of collision parameters such as the charge transfer rate coefficients between ions and neutrals. We will show that the temperature of the laser induced plasma is a rapidly decreasing function of time. The temperature is initially high but cools off rapidly through collisions with the expanding plasma electrons as the plasma recombines and streams into the vacuum. This rapid expansion of the plasma, similar to a supersonic jet, drastically lowers the internal energy of the neutrals and ions.

Kwong, V. H. S.↗

Flame Characterization Using a Tunable Solid-State Laser with Direct UV Pumping

Tunable solid-state lasers with direct UV pumping, based on d-f transitions of rare earth ions incorporated in wide band-gap dielectric crystals, are reliable sources of laser radiation that are suitable for excitation of combustion-related free radicals. We have employed such a laser for analytical flame characterization utilizing Laser-Induced Fluorescence (LIF) techniques. LIF spectra of alkane-air flames (used for studying combustion processes under normal and microgravity conditions) excited in the region of the A-X (0,0) OH-absorption band have been recorded and found to be both temperature-sensitive and positionally-sensitive. In addition, also clearly noticeable was the sensitivity of the spectra to the specific wavelength used for data registration. The LiCAF:Ce laser shows good prospects for being able to cover the spectral region between 280 and 340 nm and therefore be used excitation of combustion-intermediates such as the hydroxyl OH, methoxy CH30 and methylthio CH3S radicals.

Kamal, Mohammed M.↗