Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Geoscience Laser Altimeter System Laser Transmitter

The Geoscience Laser Altimeter System (GLAS), scheduled to launch in 2001, is a laser altimeter and lidar for tile Earth Observing System's (EOS) ICESat mission. The laser transmitter requirements, design and qualification test results for this space- based remote sensing instrument are presented.

Afzal, R. S.↗

Geodynamic laser ranging system laser transmitter

A description is given of the requirements and design options in the development of a spaceborne laser transmitter for NASA's Geodynamic Laser Ranging System. Three different oscillators are considered. The first is an injection-seeded ring oscillator yielding 1 mJ of energy within a 120-ps pulse. The second is a frequency-modulated mode-locked oscillator emitting 0.30 nJ in a 20-ps pulse. The third is a self-starting, additive pulse mode-locked laser. Detailed design considerations and preliminary results of these lasers are reported as well as the design of a unique multipass amplifier.

Dallas, J. L.↗

Performance Testing of TRL4-6 LISA Laser System

The Laser Interferometer Space Antenna (LISA) is an ESA-led future mission to measure gravitational waves from astronomical sources in space. LISA has been adopted as a formal mission by ESA in January 2024, and is expected to become a formal project at NASA within 2024. The laser system (LS), which includes four laser heads (LH) each containing a laser optical module (LOM) and laser electronics module (LEM), a frequency reference system (FRS, optical frequency reference) and four power monitor detectors (PMON), is one of the three U.S. contributions to LISA from NASA. The Lasers and Electro-Optics Branch at NASA GSFC has been developing and managing the design of the LISA LS. Currently, the TRL (technology readiness level) of the NASA LISA laser system is transitioning from 4 to 6. TRL 4/5 LISA LOM was sent to ESA in early 2023 and has undergone optical performance testing. [1] By late summer of 2024, NASA plans to deliver the TRL 6 LOM to ESA for performance evaluation. Since the delivery of the TRL4/5 LOM to ESA, we have taken steps to advance the TRL of the overall LS and have also started end-to-end system level testing involving other subsystems. They include 1) optical performance test of TRL6 LOM and TRL 5 LEM under thermal cycling, 2) end-to-end test of the laser head (LH) and the GSE (ground support equipment) FRS, driven by TRL 4 FRS electronics (FRS-E) provided by Ball Aerospace, 3) end-to-end test of the laser head (LH) with the GSE phase meter system (PMS) provided by Albert Einstein Institute, and 4) optical performance test of the LH with the PMON subsystem developed by NASA. The FRS, PMS, and PMON provide necessary frequency stability, relative phase stability between lasers, and output power stability, respectively. Since they are all vital for the sensitive laser interferometry performed in LISA, it is necessary to perform these system level testing by combining the LH and other subsystems, and to prove the optical performance at an early stage during the LS development. Our recent work has successfully demonstrated the intra-connectivity of the LS, as well as critical external interface with the PMS to meet the LISA’s performance requirements. In this talk, we will report on the latest status of the LH testing and system level test. We will also discuss the paths to bring each subsystem to TRL6+ and plans for future system level testing.

LISA↗

Contamination and Radiation Effects on Nonlinear Crystals for Space Laser Systems

Space Lasers are vital tools for NASA s space missions and military applications. Although, lasers are highly reliable on the ground, several past space laser missions proved to be short-lived and unreliable. In this communication, we are shedding more light on the contamination and radiation issues, which are the most common causes for optical damages and laser failures in space. At first, we will present results based on the study of liquids and subsequently correlate these results to the particulates of the laser system environment. We present a model explaining how the laser beam traps contaminants against the optical surfaces and cause optical damages and the role of gravity in the process. We also report the results of the second harmonic generation efficiency for nonlinear optical crystals irradiated with high-energy beams of protons. In addition, we are proposing to employ the technique of adsorption to minimize the presence of adsorbing molecules present in the laser compartment.

Abdeldayem, Hossain A.↗

A modified pump laser system to pump the titanium sapphire laser

As a result of the wide tunability of the titanium sapphire laser NASA has sited it to be used to perform differential absorption lidar (DIAL) measurements of H2O vapor in the upper and lower troposphere. The titanium sapphire laser can provide a spectrally narrow (0.3 to 1.0 pm), high energy (0.5 to 1.0 J) output at 727, 762, and 940 nm which are needed in the DIAL experiments. This laser performance can be obtained by addressing the line-narrowing issues in a master oscillator and the high energy requirement in a fundamental mode oscillator. By injection seeding, the single frequency property of the master oscillator can produce a line narrow high energy power oscillator. A breadboard model of the titanium sapphire laser that will ultimately be used in NASA lidar atmospheric sensing experiment is being designed. The task was to identify and solve any problem that would arise in the actual laser system. One such problem was encountered in the pump laser system. The pump laser that is designed to pump both the master oscillator and power oscillator is a Nd:YLF laser. Nd:YLF exhibits a number of properties which renders this material an attractive option to be used in the laser system. The Nd:YLF crystal is effectively athermal; it produces essentially no thermal lensing and thermally induced birefringence is generally insignificant in comparison to the material birefringence resulting from the uniaxial crystal structure. However, in application repeated fracturing of these laser rods was experience. Because Nd:YLF rods are not commercially available at the sizes needed for this application a modified pump laser system to replace the Nd:YLF laser rod was designed to include the more durable Nd:YAG laser rods. In this design, compensation for the thermal lensing effect that is introduced because of the Nd:YAG laser rods is included.

Petway, Larry B.↗

Laser Doppler velocimetry for continuous flow solar-pumped iodine laser system

A laser Doppler velocimetry (LDV) system was employed to measure the flow velocity profile of iodide vapor inside laser tubes of 36 mm ID and 20 mm ID. The LDV, which was operated in the forward scatter mode used a low power (15 mW) He-Ne laser beam. Velocity ranges from 1 m/s was measured to within one percent accuracy. The flow velocity profile across the laser tube was measured and the intensity of turbulence was determined. The flow of iodide inside the laser tube demonstrated a mixture of both turbulence and laminar flow. The flowmeter used for the laser system previously was calibrated with the LDV and found to be in good agreement.

Tabibi, Bagher M.↗

Application of laser Doppler velocimeter to chemical vapor laser system

A laser Doppler velocimeter (LDV) system was used to measure iodide vapor flow fields inside two different-sized tubes. Typical velocity profiles across the laser tubes were obtained with an estimated +/-1 percent bias and +/-0.3 to 0.5 percent random uncertainty in the mean values and +/-2.5 percent random uncertainty in the turbulence-intensity values. Centerline velocities and turbulence intensities for various longitudinal locations ranged from 13 to 17.5 m/sec and 6 to 20 percent, respectively. In view of these findings, the effects of turbulence should be considered for flow field modeling. The LDV system provided calibration data for pressure and mass flow systems used routinely to monitor the research laser gas flow velocity.

Gartrell, Luther R.↗

Laser Systems

Tunable diode lasers are employed as radiation sources in high resolution infrared spectroscopy to determine spectral characteristics of gaseous compounds. With other laser systems, they are produced by Spectra-Physics, and used to monitor chemical processes, monitor production of quantity halogen lamps, etc. The Laser Analytics Division of Spectra-Physics credits the system's reliability to a program funded by Langley in the 1970s. Company no longer U.S.-owned. 5/22/97

Source record↗

Progress and Plans for a US Laser System for LISA

A highly stable and robust laser system is a key component of the space-based LISA (Laser Interferometer Space Antenna) mission architecture. We describe our progress and plans to demonstrate a TRL (Technology Readiness Level) 5 LISA laser system at Goddard Space Flight Center by 2020. The laser system includes a low-noise oscillator followed by a power fiber amplifier. The oscillator is a low-mass, compact external cavity laser, consisting of a semiconductor laser coupled to an optical cavity, built by the laser vendor Redfern Integrated Optics. The amplifier is a diode-pumped Yb fiber with 2.5 watts output, built at Goddard. We show noise and reliability data for the full laser system, and describe our plans to reach TRL 5.

Camp, J.↗

Development of a US Gravitational Wave Laser System for LISA

A highly stable and robust laser system is a key component of the space-based LISA mission architecture.In this talk I will describe our plans to demonstrate a TRL 5 LISA laser system at Goddard Space Flight Center by 2016.The laser system includes a low-noise oscillator followed by a power amplifier. The oscillator is a low-mass, compact 10mW External Cavity Laser, consisting of a semiconductor laser coupled to an optical cavity, built by the laser vendorRedfern Integrated Optics. The amplifier is a diode-pumped Yb fiber with 2W output, built at Goddard. I will show noiseand reliability data for the full laser system, and describe our plans to reach TRL 5 by 2016.

Development of a US Gravitational Wave↗

An investigation of a mathematical model of an optically pumped Ti(3+):Al2O3 laser system

During the last several years, solid state lasers were developed that have the potential for meeting rigorous performance requirements for space-based remote sensing of the atmosphere. In order to design a stable and efficient laser and to understand the effect on laser output of changes in the physical and design parameters, an understanding of the development of the dynamical processes of the laser is necessary. Typically, the dynamical processes in a laser system are investigated via rate equations describing the evolution of the occupancy in the electronic levels and of the photon density in the laser cavity. There are two approaches to this type of study. Most often, for the sake of simplicity, the spatial variations of the dynamic variables in the laser system are disregarded and the mathematical model consists of a system of first order nonlinear ordinary differential equations (ODE). The second approach is to take into account both spatial and temporal variations in the dynamic variables in the laser cavity. The resulting model consists of a first order semilinear system of partial differential equations (PDE). The model which was studied was studied was generic in the sense that it was a four-level laser system, but the parameters used in the numerical study were specific to Titanium-doped sapphire. For simplicity, a constant, spatially uniform pumping scheme was considered. In addition, a simplification of the model was made so that it treats a single lasing wavelength with a narrow bandwidth. The purpose was to investigate both versions of the mathematical model and to determine whether the numerical solutions are similar both qualitatively and quantitatively. The systems of ordinary differential equations were solved numerically using a Runge-Kutta-Fehlberg algorithm which was very efficient for typical values of the physical parameters. A numerical scheme, based on the Modified Euler method, for computing solutions to the system of partial differential equations was developed and implemented. The PDE model was solved numerically at the expense of greatly increased computer time.

Roberts, Lila F.↗

Parametric infrared tunable laser system

A parametric tunable infrared laser system was built to serve as transmitter for the remote detection and density measurement of pollutant, poisonous, or trace gases in the atmosphere. The system operates with a YAG:Nd laser oscillator amplifier chain which pumps a parametric tunable frequency converter. The completed system produced pulse energies of up to 30 mJ. The output is tunable from 1.5 to 3.6 micrometers at linewidths of 0.2-0.5 /cm (FWHM), although the limits of the tuning range and the narrower line crystals presently in the parametric converter by samples of the higher quality already demonstrated is expected to improve the system performance further.

Garbuny, M.↗

Dynamically variable spot size laser system

A Dynamically Variable Spot Size (DVSS) laser system for bonding metal components includes an elongated housing containing a light entry aperture coupled to a laser beam transmission cable and a light exit aperture. A plurality of lenses contained within the housing focus a laser beam from the light entry aperture through the light exit aperture. The lenses may be dynamically adjusted to vary the spot size of the laser. A plurality of interoperable safety devices, including a manually depressible interlock switch, an internal proximity sensor, a remotely operated potentiometer, a remotely activated toggle and a power supply interlock, prevent activation of the laser and DVSS laser system if each safety device does not provide a closed circuit. The remotely operated potentiometer also provides continuous variability in laser energy output.

Gradl, Paul R.↗

Analysis of He-N2-CO2-UF6 laser system

Direct nuclear pumping of a CO2 laser system by the U-235(n,ff)FF reaction is examined. Calculations based on a kinetic model which takes into consideration all relevant kinetic processes indicate that dissociation of CO2 prevents the efficient operation of a nuclear pumped CO2 laser system.

Hassan, H. A.↗

A Completely Solid-State Tunable Ti:Sapphire Laser System

Compact, completely solid-state tunable pulsed laser system passively cooled developed for potential employment in aircraft and sounding-rocket lidar experiments. Ti:sapphire based laser system pumped with frequency-doubled diode-pumped Nd:YAG. Rugged, self-contained system extremely flexible and provides pulsed output at specific frequencies with low input-power requirements. In-situ measurements enables scientists to study upper-atmosphere dynamics. Tuning range easily extended to bands between 650-950 nm in order to study other atmospheric constituents.

Guerra, David V.↗

Advancement of the Laser System for the LISA Mission

NASA Goddard Space Flight Center (GSFC) is developing the Laser System (LS) for the Laser Interferometer Space Antenna (LISA) mission, led by the European Space Agency (ESA) with a launch date of 2035. In this talk, we will present the roadmap in advancing the LISA Laser System to meet the LISA mission requirements.

Anthony W. Yu↗