Search NASA⌕ Search

SEARCH · Search NASA

Results for “lightning safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Developing a Lightning All-Clear Signal for the Savannah River Site

Lightning safety is a major concern at the Savannah River Site (SRS). Notifications are provided when 3-strikes occur onsite within a 15-minute period. It is generally left up to individual contractors at SRS to determine when it is safe for workers to return to outside work, generally following a 3-hour period of no lightning, after the last lightning strike occurs. This work tries to improve safe return to work decisions by developing a reliable all-clear signal using an electric field mill. The best signal used thresholds from multiple electric field values to provide an average delay for return to work of 2 hours and 13 minutes. This average was heavily influenced by lingering storms in the area or missing data from power or network outages. One event out of 98 signaled the all-clear prior to another event occurring less than 60 minutes later. Regardless, 62% of the all clear signals had delay times less than the mean and 72% had delay times less than the current 3-hour delay after the last strike. This provides better worker safety for returning to work than 30 minutes after the last lightning strike (e.g. OSHA Lightning Safety) and improves the delay time from the current 3-hour delay.

Noble, Stephen [Savannah River National Laboratory↗

The Hazards Posed by Mesoscale Lightning Megaflashes

Lightning megaflashes extending over >100-km distances have been observed by the Geostationary Lightning Mappers (GLMs) on NOAA’s R-series Geostationary Operational Environmental Satellites (GOES). The hazards posed by megaflashes are unclear, however, because of limitations in the GLM data. We address these by reprocessing GOES-16 GLM measurements from 1 January 2018 to 15 January 2020 and integrating them with Earth Networks Global Lightning Network (ENGLN) observations. ENGLN verified 194 880 GLM megaflashes as natural lightning. Of these, 127 479 flashes occurred following the October 2018 GLM software update that standardized GLM timing. Reprocessed GLM/ENGLN lightning maps from these postupdate cases provide a comprehensive view of how individual megaflashes evolve. This megaflash dataset is used to generate statistics that describe their hazards. The average megaflash produces 5–7 cloud-to-ground (CG) strokes that are spread across 40%–50% of the flash extent. As flash extent increases beyond 100 km, megaflashes become concentrated in key hot-spot regions in North and South America while the number of CG and intracloud events per flash and the overall peak current increase. CGs in the larger megaflashes occur over 80% of the flash extent measured by GLM, and the majority contain regions where the megaflash is the only lightning activity in the preceding hour. These statistics demonstrate that there is no safe location below an electrified cloud that is producing megaflashes, and current lightning safety guidance is not always sufficient to mitigate megaflash hazards.

54 ENVIRONMENTAL SCIENCES↗

Exploring the Early Lightning Notification of an Electric Field Mill at the Savannah River Site

At the Savannah River Site (SRS), employees receive automated broadcast notification about lightning only after three strikes have already occurred near the site boundary. To increase employee safety, it is preferential to give employees lead time before lightning strikes occur. We compared measurements from an on-site electric field mill to lightning detection data from the National Lightning Detection Network and the Geostationary Lightning Mapper. Using a difference threshold, we determined that the electric field mill provided a lead time greater than 6 minutes for 95% of lightning events from 2009-2020, with an average lead time of 56 minutes. Detection of events were limited to a 7-mile radius around the field mill. We also identified that the field mill threshold generated many false detections not clearly identified. False detections and detections from only precipitation can be reduced by using a second threshold without creating too many missed detections (Type II errors). The two thresholds used together provide the best information about rapidly changing electric fields and aid in advanced detection necessary to improve the lightning warning system used at SRS.

42 ENGINEERING↗

Lightning strike prediction at the Savannah River Site

At the Savannah River Site, employees receive warnings about lightning only after three strikes have already occurred near the site. In order to increase employee safety, it is preferential to warn employees of a lightning threat much sooner. We used data from an on-site Electric Field Mill to measure values of the atmospheric electric charge. We also used lightning detection data from the National Lightning Detection Network and the Geostationary Lightning Mapper. By comparing the data of each, we can determine how long before or after a lightning strike did the Electric Field Mill first measure within our lightning detection threshold. If the detection threshold occurs before the strike does, this provides a lead time for knowing about lightning risks before they happen. Our findings conclude that 95% of lightning strikes have a lead time in the electric field where we can predict the lightning before it occurs and warn employees of the potential lightning threat. However, our lightning detection threshold can occur even without lightning or precipitation. Finding how these false lightning alarms affect our data is necessary to improving the lightning warning system.

54 ENVIRONMENTAL SCIENCES↗

New World Meteorological Organization Certified Megaflash Lightning Extremes for Flash Distance (709 km) and Duration (16.73 s) Recorded From Space

Identification and validation of atmospheric extremes are essential to monitoring climate change, to addressing engineering and safety concerns, and to promoting technological advancement. An international World Meteorological Organization evaluation committee has critically adjudicated and recommended acceptance of two lightning megaflash events (horizontal mesoscale lightning discharges of >100 km in length) as new global extremes using analysis of Geostationary Lightning Mapper data. The world's greatest extent for an individual lightning flash is a single flash that covered a horizontal distance of 709 ± 8 km (441 ± 5 mi) across parts of southern Brazil on 31 October 2018. Furthermore, the greatest duration for a single lightning flash is 16.730 ± 0.002 s from a flash that developed continuously over northern Argentina on 4 March 2019.

54 ENVIRONMENTAL SCIENCES↗

Enhanced lightning strike protection using vertically oriented carbon fiber melded with conventional carbon fiber-reinforced composite and its validation through damage analysis

Lightning strike protection (LSP) is one of the prime factors in aerospace and wind industries concerning safety, enhanced service life, and reduced downtime. To ensure better LSP, high electrical conductivity is required to dissipate the current, which is always a challenge for polymer composites due to the inherent insulating nature of the polymer matrix. Conventional carbon fiber-reinforced composites (CFRP) offer electrical conductivity in the planar direction while the vertical i.e. through-thickness conductivity still remains a challenge. Having been motivated by this fact, we have fabricated CFRP interleaved with vertically oriented CF (Z-fiber) for the lightning strike test (100 kA). A paint was applied to mimic the actual service condition of the composite laminates. We have prepared two Z-fiber composites: (a) Z-1 containing one Z-fiber layer on the top along with conventional CF layers and (b) Z-5 containing five interleaved Z-fiber layers and compared the properties with conventional CFRP (Z-0). Interestingly, even a single Z-fiber layer (Z-1) showed lower damage (visual damage diameter 22 mm) than Z-0 (visual damage diameter 26 mm). Z-5 displayed the lowest damage (visual damage diameter 16.7 mm), which was further confirmed by cross-sectional optical microscopy. Improved LSP was attributed to the higher through-thickness electrical conductivity in the case of Z-5 (9 times with respect to Z-0) reflecting a lower electrical anisotropy for Z-fiber composites. The residual mechanical property after the lightning test was analyzed through the flexural test, and the retention of flexural strength and modulus was 66% and 86%, respectively for Z-5 showing a significant improvement in comparison to Z-0 (>40% for both).

Saha, Subhabrata↗

A Roadmap for a Lightning Modeling Grand Challenge

This document is a roadmap for building an interconnected model of the physical processes that produce a lightning discharge, and its observable optical and radio signals. We call this a Lightning Modeling Grand Challenge, recognizing that significant effort and coordination of human and financial resources is required to realize the capability. The roadmap serves to outline the coordination of resources necessary to enable stitching together existing knowledge and model components to make a lightning prediction, and to test these predictions with observations. Such a capability does not currently exist. The roadmap is motivated not only by a spirit of scientific inquiry, but by practical challenges faced by US Federal and societal stakeholders. Advancements in lightning observations have outpaced our tests of integrated understanding, leaving many stakeholders unsure how to design their missions to properly detect and discriminate lightning, and unsure how to apply the sometimes-disagreeing lightning signals from diverse instruments. The time is right to connect existing theories and models to support stakeholders in understanding the signals they observe, for needs as diverse as climate monitoring, national security, weather forecasting, public safety, and protection of natural and built environments. The roadmap’s two main technical sections describe the components of a linked physical model, followed by a description of models of lightning signals and sensors that are driven by outputs from the physical model. The goal is to predict the time-varying physical properties of lightning that are self-consistent with the thunderstorm’s structure and dynamics. These lightning signals then propagate through the storm, with realistic dispersion and attenuation, to receivers on the ground or in space. At a high level, the model begins with weather (cloud) model output, including explicit prediction of the electrification of cloud particles. The cloud’s electrical structure drives a model of lightning physics, from initiation, through channel development, and discharges along those channels. Key lightning parameters, such as the temperature and currents in the channel, and their space and time distribution, are then used to produce optical and electromagnetic signal sources that propagate to modeled receivers. This architecture therefore generates a dataset suitable for comparison to existing and envisioned observing systems. The need for additional measurements and field campaigns to support model development is described. In each model sub-component, inputs, outputs, uncertainties, evaluation methods, and next steps are summarized, interleaved with references to the scientific literature. Identifying boundaries between the model sub-components aids in segmenting an integrated, complex model into practical work packages and system sub-components, allowing a diverse team to contribute and maintain the system. We estimate that at least five years of effort and a $\$$10M initial investment is necessary to make a significant step forward. Mechanisms to facilitate community coordination, including annual workshops and open-source code repositories, are described.

54 ENVIRONMENTAL SCIENCES↗

Descriptor: High Temporal Resolution Meteorological Data at Oak Ridge Reservation (ORR-HiResMet)

Access to continuous, quality assessed meteorological data is critical for understanding the climatology and atmospheric dynamics of a region. Research facilities like Oak Ridge National Laboratory (ORNL) rely on such data to assess site-specific climatology, model potential emissions, establish safety baselines, and prepare for emergency scenarios. To meet these needs, on-site towers at ORNL collect meteorological data at 15-minute and hourly intervals. However, data measurements from meteorological towers are affected by sensor sensitivity, degradation, lightning strikes, power fluctuations, glitching, and sensor failures, all of which can affect data quality. To address these challenges, we conducted a comprehensive quality assessment and processing of five years of meteorological data collected from ORNL at 15-minute intervals, including measurements of temperature, pressure, humidity, wind, and solar radiation. The time series of each variable was pre-processed and gap-filled using established meteorological data collection and cleaning techniques, i.e., the time series were subjected to structural standardization, data integrity testing, automated and manual outlier detection, and gap-filling. The data product and highly generalizable processing workflow developed in Python Jupyter notebooks are publicly accessible online. As a key contribution of this study, the evaluated 5-year data will be used to train atmospheric dispersion models that simulate dispersion dynamics across the complex ridge-and-valley topography of the Oak Ridge Reservation in East Tennessee.

Steckler, Morgan R. [Oak Ridge National Laboratory↗

Impact of Urbanization on Convection, Lightning, and Precipitation Over the Houston Metropolitan Area: Case Study Simulation From the TRACER Campaign

This study investigates the effects of urbanization, specifically land use change and anthropogenic emissions (AE), on convection, lightning, and surface precipitation for a case of summertime sea‐breeze convection observed over the Houston metropolitan area. The unique capabilities of the NASA‐Unified Weather Research and Forecasting model allows us to conduct a series of sensitivity experiments with complex configurations, in particular including multi‐year land model spin‐up simulations, treatment of aerosols and their precursors, and explicit cloud charging and lightning. The simulation results show that urban land use primarily alters the temporal evolution of convection, lightning, and surface precipitation, leading to late afternoon thunderstorm development. The decrease in latent heat flux from the land surface caused by urbanization weakens convection in the early afternoon, while a condition suitable for convection development is maintained in the late afternoon due to less stabilization of the lower troposphere by the weaker convection development and high sensible heat flux from the surface. On the other hand, anthropogenic aerosols directly enhance convection, lightning, and surface precipitation by increasing convective updrafts due to the aerosol‐induced convective invigoration. The combined effects of urban land use and AE lead to even stronger thunderstorms in the late afternoon, mostly consistent with observations. These results indicate that urbanization increases the probability of late afternoon thunderstorms over the Houston area during the summer season. Advanced weather forecasting models that incorporate these urbanization effects might support sustainable urban planning to better mitigate the impacts of urbanization on local weather and public safety.

Iguchi, T. [Univ. of Maryland, College Park, MD (U↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗