Advanced High Torque Density Magnetically Geared Generator

The objective of this research project was to investigate the fundamental torque density limitations of multistage flux focusing magnetic gears and magnetically geared direct-drive generators for wind turbines. Magnetic gears create non-contact speed amplification by modulating the air-gap magnetic field harmonics created by magnetic rotors. By integrating a stator into the magnetic gear structure a very high torque density direct-drive generator can be created. Magnetic geared systems offer unique capabilities that are currently not available using existing mechanically geared systems, such as overload protection. Magnetic gears also offer the potential for higher reliability, higher efficiency and quieter operation than is currently achievable using a mechanically geared generator. By increasing reliability and design life magnetic gears could decrease the overall life-cycle costs when compared with equivalent mechanical or direct-drive drivetrains. This research project investigated and experimentally testing two sub-scale magnetic gearboxes (0.12 m diameter) and two large diameter magnetic gearboxes (0.56m and 0.63m diameter). The goal of the project was to demonstrate a torque density >300Nm/L for a multistage magnetic gearbox with integrated stator. A nested multistage magnetic gear structure was first proposed and studied. However, it was shown that the nested design greatly increased mechanical complexity and therefore a two-stage series typology was utilized. A multi-stage magnetic gear with a 59:1 gear ratio was successfully experimentally tested. A peak torque of 4.25 kN·m was measured and this resulted in an overall active region torque density of 141 N·m/L (when including support rings). The torque density was significantly reduced from what was computed using 2-D electromagnetic analysis. This reduction was due to the 3-D edge effects, increased power losses and the inclusion of additional mechanical support rings as well as other mechanical assembly design changes. At large diameters contiguous lamination parts could not be fabricated and so a segmented laminated rotor design had to be used. This reduced the mechanical strength of the design when compared to small diameter magnetic gears and resulted in the need for the addition of mechanical support rings to prevent deflection. The final experimentally tested design also had a high torque ripple and the power loss within the magnetic gear did not change significantly with load. This therefore resulted in the efficiency being high only at peak loads. Despite not experimentally achieving the 2-D calculated high torque density the analysis has shown that the problems encountered with the scaling can be overcome with careful design changes. For example, understanding the unique mechanical deflection requirements during the electromagnetic design of the large diameter magnetic gears is key to achieving both a high torque density based on the electromagnetic analysis and a high torque density based on the mechanical support needs. Furthermore, ensuring that end plates are made of non-conductive material and minimizing other conductive support elements within the magnetic structure is a key requirement for reducing eddy current losses. In summary, if the mechanical design can be made more robust and eddy current loss mitigation strategies are used in the mechanical design phase then the magnetic gear is capable of being scaled up whilst operating at a very high torque density. This will then enable it to be potentially performance and cost competitive with alternative direct-drive and mechanically geared wind turbine drivetrains.

17 WIND ENERGY↗

Investigate the Performance and Cost Benefits of Using a Magnetically Geared Generator (MGG) for a Hydropower Generator

The operating principles of MGs have been explained in section 1. In section 3, the ideal MG design will be discussed with a pole pair combination of 11-71-60. The parameter sweeping analysis has been conducted. In section 4, another design with extended magnets is discussed. The flux concentration topology will be discussed in section 5. In order to reduce the simulation time, especially when doing the loss analysis in 3-D, a new pole pair combination (12-78-66) has been chosen so that the MG can be simulated in a 1/6 model which is present in section 6. In section 7, a MG with extra radial flux will be introduced and the performance will be evaluated. The deflection and loss are also discussed. In section 8, the stage 2 MG will be discussed which uses a similar topology as stage 1 MG. The mechanical deflection of the rods and the efficiency will be calculated. In section 9, the stator will be added inside the stage 2 MG. The fractional winding distribution will be designed. The cost and scaling analysis are discussed in section 10 and section 11, respectively.

13 HYDRO ENERGY↗

Stage 2 Sub-Scale Magnetic Gear

The goal of this project is to design, fabricate, and test a hermetically sealed 50 kilowatt (kW) multistage magnetically geared generator (MGG). In order to reduce risk, a sub-scale 5kW multistage MGG was first built. This project will benefit MHK device developers by providing an MHK PTO that overcomes the reliability concerns of the mechanical gears and the sizing constraints of the direct-drive generators. 7.67:1 gear ratio magnetic gear with a measured peak torque of 1796 N-m

16 TIDAL AND WAVE POWER↗

Sub-Scale Stage 1 Magnetic Gear for a Marine Hydrokinetic Generator

The goal of this project is to design, fabricate, and test a hermetically sealed 50 kilowatt (kW) multistage magnetically geared generator (MGG). In order to reduce risk, a sub-scale 5kW multistage MGG was first built. This project will benefit MHK device developers by providing an MHK PTO that overcomes the reliability concerns of the mechanical gears and the sizing constraints of the direct-drive generators. Measurement data for a 9.5:1 gear ratio magnetic gear with a measured peak torque of 227 N-m as well as the dual stage magnetic gear with a 63:1 gear ratio.

16 TIDAL AND WAVE POWER↗

Electromagnetic and Mechanical Design of a Hermetically Sealed Magnetic Gear for a Marine Hydrokinetic Generator

This article presents a new type of hermetically sealed magnetically geared generator typology for a marine hydrokinetic application. The proposed magnetically geared generator is composed of two series connected magnetic gearbox stages with the second stage having an integrated stator. This paper focuses only on presenting the electromagnetic design for the first stage magnetic gearbox with a 5kW (at 40RPM) rating. A volumetric and mass torque density tradeoff analysis is utilized in order to arrive at a high torque density design. The designed magnetic gearbox uses a unique laminated flux concentration inner rotor and Halbach array outer rotor typology with a 6.67:1 gear ratio. Furthermore, a mechanical deflection analysis is performed to verify that the proposed magnetic gearbox is mechanically robust.

16 TIDAL AND WAVE POWER↗

Stage 2 Full-Scale Rotary Magnetic Gear for a Marine Hydrokinetic Generator

The goal of this project is to design, fabricate, and test a hermetically sealed 50 kilowatt (kW) multistage magnetically geared generator (MGG). This project will benefit MHK device developers by providing an MHK PTO that overcomes the reliability concerns of the mechanical gears and the sizing constraints of the direct-drive generators. Experimental Testing Data for a 6.66:1 gear ratio dual-stack magnetic gear with a measured peak torque of 1391 N-m

16 TIDAL AND WAVE POWER↗

Magnetic Gears for a Marine Hydrokinetic Generator Component Model

The goal of this project is to design, fabricate, and test a hermetically sealed 50 kilowatt (kW) multistage magnetically geared generator (MGG). The Component Content Model provides data submitters with an easy and consistent means of uploading data and associated meta data about a component that is currently under development. The data fields include generic information about the component, technology classifications, current costs and performance, proposed target goals, and the environment that the component is operated in. These data are important to DOE and will be used to develop data products that provide quantitative information to guide and support programmatic decisions. Data will also be used by DOE in general assessments of MHK component readiness, performance, costs, and proposed plans. The ultimate goal is to use these data to perform research and tailor programs to best benefit the industry.

16 TIDAL AND WAVE POWER↗

Advanced Direct-Drive Generator for Improved Availability of Oscillating Wave Surge Converter Power Generation Systems Final Technical Report

This report summarizes the activities conducted under the DOE-EERE funded project DE-EE0006400, where ABB Inc. (ABB), in collaboration with Texas A&M’s Advanced Electric Machines & Power Electronics (EMPE) Lab and Resolute Marine Energy (RME) designed, derisked, developed, and demonstrated a novel magnetically geared electrical generator for direct-drive, low-speed, high torque MHK applications The project objective was to investigate a novel and compact direct-drive electric generator and its system aspects that would enable elimination of hydraulic components in the Power Take-Off (PTO) of a Marine and Hydrokinetic (MHK) system with an oscillating wave surge converter (OWSC), thereby improving the availability of the MHK system. The scope of this project was limited to the development and dry lab demonstration of a low speed generator to enable future direct drive MHK systems.

16 TIDAL AND WAVE POWER↗

Optimized Generator Designs for the DTU 10-MW Offshore Wind Turbine using GeneratorSE

Compared to land-based applications, offshore wind imposes challenges for the development of next generation wind turbine generator technology. Direct-drive generators are believed to offer high availability, efficiency, and reduced operation and maintenance requirements; however, previous research suggests difficulties in scaling to several megawatts or more in size. The resulting designs are excessively large and/or massive, which are major impediments to transportation logistics, especially for offshore applications. At the same time, geared wind turbines continue to sustain offshore market growth through relatively cheaper and lightweight generators. However, reliability issues associated with mechanical components in a geared system create significant operation and maintenance costs, and these costs make up a large portion of overall system costs offshore. Thus, direct-drive turbines are likely to outnumber their gear-driven counterparts for this market, and there is a need to review the costs or opportunities of building machines with different types of generators and examining their competitiveness at the sizes necessary for the next generation of offshore wind turbines. In this paper, we use GeneratorSE, the National Renewable Energy Laboratory's newly developed systems engineering generator sizing tool to estimate mass, efficiency, and the costs of different generator technologies satisfying the electromagnetic, structural, and basic thermal design requirements for application in a very large-scale offshore wind turbine such as the Technical University of Denmark's (DTU) 10-MW reference wind turbine. For the DTU reference wind turbine, we use the previously mentioned criteria to optimize a direct-drive, radial flux, permanent-magnet synchronous generator; a direct-drive electrically excited synchronous generator; a medium-speed permanent-magnet generator; and a high-speed, doubly-fed induction generator. Preliminary analysis of leveled costs of energy indicate that for large turbines, the cost of permanent magnets and reliability issues associated with brushes in electrically excited machines are the biggest deterrents for building direct-drive systems. The advantage of medium-speed permanent-magnet machines over doubly-fed induction generators is evident, yet, variability in magnet prices and solutions to address reliability issues associated with gearing and brushes can change this outlook. This suggests the need to potentially pursue fundamentally new innovations in generator designs that help avoid high capital costs but still have significant reliability related to performance.

17 WIND ENERGY↗

Beyond 15 MW: A cost of energy perspective on the next generation of drivetrain technologies for offshore wind turbines

Leading wind turbine manufacturers are racing to build larger and more powerful offshore machines. Drivetrain configurations often use a permanent-magnet synchronous generator (PMSG), in either a direct-drive configuration or coupled to a gearbox. With increasing demand for critical rare-earth magnets, new generator technologies are emerging to ensure a stable and secure supply chain. We evaluate three different topologies of radial flux synchronous generators employing high field magnets with reduced or no rare-earth content: a direct-drive interior PMSG (DD-IPMSG), a geared drivetrain combining a medium speed gearbox with a PMSG (MS-PMSG), and a direct-drive low-temperature superconducting generator (DD-LTSG). We develop a conceptual design module for each of these technologies within a larger framework for full turbine design. This provides the fairest comparison between technologies at nominal power ratings from 15-25 MW, which represent the next generation of offshore wind turbines. The analyses show that if operational expenditures (OpEx) are constant across the technologies, MS-PMSG results in the lowest LCOE with reductions of up to 7% relative to DD-IPMSG. DD-LTSG also yields lower LCOE values by 2%-3% for fixed-bottom turbines and 3%-5% with a floating platform. However, results are sensitive to OpEx assumptions, with a mere 10% increase causing the conclusions to shift.

17 WIND ENERGY↗

A Comparison of Generator Technologies for Offshore Wind Turbines

Leading wind turbine manufacturers are racing to build larger and more powerful offshore machines. Drivetrain configurations often use a permanent-magnet synchronous generator (PMSG), in either a direct-drive configuration or coupled to a gearbox. With increasing demand for critical rare-earth magnets, new generator technologies are emerging to ensure a stable and secure supply chain. We evaluate three different topologies of radial flux synchronous generators employing high field magnets with reduced or no rare-earth content: a direct-drive interior PMSG (DD-IPMSG), a geared drivetrain combining a medium speed gearbox with a PMSG (MS-PMSG), and a direct-drive low-temperature superconducting generator (DD-LTSG). We develop a conceptual design module for each of these technologies within a larger framework for full turbine design. This provides the fairest comparison between technologies at nominal power ratings from 15-25MW, which represent the next generation of offshore wind turbines. The analyses show that if operational expenditures (OpEx) are constant across the technologies, MS-PMSG results in the lowest LCOE with reductions of up to 7% relative to DD-IPMSG. DD-LTSG also yields lower LCOE values by 2-3% for fixed-bottom turbines and 3-5% with a floating platform. However, results are sensitive to OpEx assumptions, with a mere 10% increase causing the conclusions to shift.

direct drive↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.