Search NASA⌕ Search

SEARCH · Search NASA

Results for “malicious sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Designing an Intrusion Detection for an Adjustable Speed Drive System Controlling a Critical Process

In this article, we address the cyber-security problem of industrial control systems (ICSs) when their sensor measurements may be compromised due to an attacker who has intercepted those measurements via a network. We introduce a general-purpose method “Dynamic Watermarking (DW)” to detect potential cyber-intrusions on speed sensor measurements within industrial control systems, which deploy an adjustable speed drive (ASD) to control a critical process. The DW method is injecting a random private low-amplitude signal with a zero mean Gaussian distribution, “watermark”, into one of the input phase voltages powering the ASD system. The watermark signal propagates through the system including pulse width modulation (PWM) power conversion stage and motor, then ultimately appears in the speed sensor measurements. By deploying two statistical DW tests with two proper thresholds, the system can detect potential cyber-intrusions or unobservable cyber-attacks such as replay attacks and false data injection attacks (FDIA). The DW method tested on a laboratory-scale ASD system experimentally to protect the system against cyber-intrusions. This system, powered by a commercial PWM drive operating at 208 V, 3-phase, and 3.7 kW, served as our experimental platform.

42 ENGINEERING↗

Detection of Cyber Attacks in Grid-tied PV Systems Using Dynamic Watermarking

This paper presents of an active detection scheme for detecting cyber attacks on sensors controlling a grid-tied PV systems. Several cyber vulnerabilities in Grid tied PV Systems are discussed. The defense mechanism introduces a private (secret) watermarking signal into the control inputs of the grid-tied inverter system. This will enable the detection of any malicious manipulation of sensor measurements. Based on the measured data, two statistical tests are conducted to identify anomalies in the system using the presence of the watermarking signal. It shown that when a sensor data is compromised and/or replaced by a pre-recorded healthy signal, both test 1 and 2 exhibit high values indicating a possible malicious activity. The robustness of the proposed algorithm is tested and validated with several attack scenarios on a grid tied PV system. Select results from an experimental setup are discussed.

Ibrahim, Hasan↗

Learning-based framework for sensor fault-tolerant building HVAC control with model-assisted learning

As people spend up to 87% of their time indoors, intelligent Heating, Ventilation, and Air Conditioning (HVAC) systems in buildings are essential for maintaining occupant comfort and reducing energy consumption. These HVAC systems in smart buildings rely 'on real-time sensor readings, which in practice often suffer from various faults and could also be vulnerable to malicious attacks. Such faulty sensor inputs may lead to the violation of indoor environment requirements (e.g., temperature, humidity, etc.) and the increase of energy consumption. While many model-based approaches have been proposed in the literature for building HVAC control, it is costly to develop accurate physical models for ensuring their performance and even more challenging to address the impact of sensor faults. In this work, we present a novel learning-based framework for sensor fault-tolerant HVAC control, which includes three deep learning based components for 1) generating temperature proposals with the consideration of possible sensor faults, 2) selecting one of the proposals based on the assessment of their accuracy, and 3) applying reinforcement learning with the selected temperature proposal. Moreover, to address the challenge of training data insufficiency in building-related tasks, we propose a model-assisted learning method leveraging an abstract model of building physical dynamics. Through extensive experiments, we demonstrate that the proposed fault-tolerant HVAC control framework can significantly reduce building temperature violations under a variety of sensor fault patterns while maintaining energy efficiency.

Xu, Shichao↗

An Active Detection Scheme for Sensor Spoofing in Grid-tied PV Systems

In this paper an active detection scheme for sensor spoofing (manipulated externally via a cyber attack) in grid-tied PV systems is discussed. The core of the proposed active detection scheme is to introduce a private (secret) watermarking signal into the control inputs of the DC-DC converter and DC-AC inverter stages to detect any malicious spoofing (manipulation) of voltage/current sensor measurements controlling both the DC-DC converter maximum power point tracking (MPPT) stage and the DC-AC inverter of the grid-tied PV system. Several types of possible spoofing mechanisms (attack models) are discussed. The proposed sensor spoofing attack detector system consists of injecting a small magnitude of digital watermarking signal (DWS) and conduct three statistical watermark tests on the reported sensor measurements to determine if a) the proposed system is healthy and operating as expected b) if sensor signals were spoofed (manipulated) externally or c) if a particular sensor is malfunctioning due to a faulty hardware. It is shown via extensive simulations that the proposed DWS approach is robust in detecting malicious external manipulation of sensors controlling the grid tied PV system. A testing platform is currently under development and the experimental results will be discussed in the conference presentation.

Ibrahim, Hasan↗

Data trustworthiness signatures for nuclear reactor dynamics simulation

With the increased reliance on digitization in industrial control systems, the need for effective monitoring techniques has risen dramatically. Specifically, there is now a growing concern about the so-called false data injection (FDI) attacks. These attacks aim to alter the raw sensors’ data to cause malicious outcomes. Any serious FDI algorithm is based on an intimate knowledge of the system and its associated physics models, which renders conventional outlier/anomaly detection techniques almost obsolete in the face of such attacks. Thus, a critical need has emerged to develop a new class of defense methods that are capable of detecting FDI attacks under the assumption that the attacker has a strong familiarity with the system and its physics modeling. This class of defense methods are denoted by model-based defenses which are premised on the assumption that the attacker, while having a good understanding of the system, does not have full privileged access to all proprietary data and historical records of operation. However, (s)he is assumed to be capable of learning system behavior using self-learning techniques during an initial lie-in-wait period. To defend against this scenario, we propose a new model-based randomized window algorithm that searches time-series data for signatures that can serve as classifiers between normal and FDI scenarios. The classifiers are based on the correlations between the dominant degrees of freedom (DOFs) and the less-dominant DOFs (expected to be very sensitive to the system details that are unknown to the attacker). For demonstration, RELAP5 models are employed to calculate representative nuclear reactor behavior during a number of transient scenarios. Finally, falsified data are injected into the RELAP5-simulated behavior, and the proposed signature-identification algorithm is employed to detect the injected data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isolating Signatures of Cyberattacks under Stressed Grid Conditions

In a controlled cyber-physical network, such as a power grid, any malicious data injection in the sensor measurements can lead to widespread impact due to the actions of the closed-loop controllers. While fast identification of the attack signatures is imperative for reliable operations, it is challenging to do so in a large dynamical network with tightly coupled nodes. A particularly challenging scenario arises when the cyberattacks are strategically launched during a grid stress condition, caused by non-malicious physical disturbances.

Ghosh, Sanchita [BATTELLE (PACIFIC NW LAB)]↗

Cyber-Secure and Safe Operation of Solar Photovoltaic Power Distribution Systems

Solar photovoltaic (PV)-rich power distribution systems are networked Cyber-Physical Systems (CPS). These are control systems where multiple computing nodes and diverse intelligent agents interact with the physical world in real-time. However, the presence of networked components renders them vulnerable to potential cyber-attacks, cyber-intrusions, and other malicious events. This is because these systems depend on the measurements reported from their heterogeneous sensors. This makes them vulnerable to potential cyber-attacks where malicious agents can compromise the sensors or the communication networks carrying the sensor measurements. This paper proposes a novel methodology for enhancing the cyber-security and cyber-resilient post-attack safe operation of solar PV-rich power distribution systems against potential cyber-attacks through the Dynamic Watermarking (DW), using online system identification. The resiliency of the proposed technique is tested and validated with several attack scenarios on both a lab-scale 3kW grid-connected PV inverter and a Hardware-in-the-Loop (HiL) system. The proposed approach can be applied to other types of power distribution systems to enhance their cyber-secure and cyber-resilient safe operation. This paper thereby contributes to the field of cyber-security of Cyber-Physical Energy Systems (CPES).

Kim, Jaewon↗

Model-Agnostic Algorithm for Real-Time Attack Identification in Power Grid using Koopman Modes

Malicious activities on measurements from sensors like Phasor Measurement Units (PMUs) can mislead the control center operator into taking wrong control actions resulting in disruption of operation, financial losses, and equipment damage. In particular, false data attacks initiated during power systems transients caused due to abrupt changes in load and generation can fool the conventional model-based detection methods relying on thresholds comparison to trigger an anomaly. In this paper, we propose a Koopman mode decomposition (KMD) based algorithm to detect and identify false data attacks in real-time. The Koopman modes (KMs) are capable of capturing the nonlinear modes of oscillation in the transient dynamics of the power networks and reveal the spatial embedding of both natural and anomalous modes of oscillations in the sensor measurements. The Koopman-based spatio-temporal nonlinear modal analysis is used to filter out the false data injected by an attacker. The performance of the algorithm is illustrated on the IEEE 68-bus test system using synthetic attack scenarios generated on GridSTAGE, a recently developed multivariate spatio-temporal data generation framework for simulation of adversarial scenarios in cyber-physical power systems.

Nandanoori, Sai Pushpak↗

R2U2 in Space: System and Software Health Management for Small Satellites

In order for small but complex systems like rovers, SmallSats, or Unmanned Aircraft (UAS) to operate autonomously, they must have a real-time solution for assessing their own system health. System and Software Health Management (SHM) enables better detection of faulty sensors and software problems, and enables better fault management including mitigation of unpredicted fault scenarios in the absence of a human on-board. In recent work, we have developed a Responsive, Realizable, Unobtrusive Unit (R2U2) for on-board SHM of autonomous UAS and demonstrated its ability to detect faults during flight time. These faults, from sensor failures, to software problems, to malicious security attacks, can present as transient temporal faults that even humans are challenged to find. An R2U2 congfiuration is a modular combination of multiple types of temporal logic runtime observers with fault-specic Bayesian Nets and sensor filters. R2U2 reasons about both on-board hardware and software components; R2U2 itself can be instantiated as an independent FPGA (Field-Programmable Gate Array)-based conguration or as a software component running independently from other software on-board. Small satellites, such as CubeSats, also require on-board SHM and failure mitigation, as limited telemetry bandwidth does not allow the transmission of the entire system state for ground-based health management. However, the autonomous operation of satellites brings a set of challenges different from UAS, including the effects of radiation on non-rad-hard, low-cost components, and the harsher environment of space. We surmise that a new extension of R2U2 could be adapted to help better detect, for example, radiation errors in cheaper COTS (Commercial Off the Shelf) (not rad-hard) components often used in small space systems. Since small satellites often operate in coordination, we will also examine new ways of distributed monitoring of their communication and cooperation and real-time detection of off-nominal situations utilizing multiple satellites. This talk will discuss preliminary work and ideas for building on terrestrial success of system and software health management for the harsher, and differently challenging, environment of space.

Runtime Verification & Validation↗

Detection, Localization, and Tracking of Unauthorized UAS and Jammers

Small unmanned aircraft systems (UASs) are expected to take major roles in future smart cities, for example, by delivering goods and merchandise, potentially serving as mobile hot spots for broadband wireless access, and maintaining surveillance and security. Although they can be used for the betterment of the society, they can also be used by malicious entities to conduct physical and cyber attacks to infrastructure, private/public property, and people. Even for legitimate use-cases of small UASs, air traffic management (ATM) for UASs becomes of critical importance for maintaining safe and collusion-free operation. Therefore, various ways to detect, track, and interdict potentially unauthorized drones carries critical importance for surveillance and ATM applications. In this paper, we will review techniques that rely on ambient radio frequency signals (emitted from UASs), radars, acoustic sensors, and computer vision techniques for detection of malicious UASs. We will present some early experimental and simulation results on radar-based range estimation of UASs, and receding horizon tracking of UASs. Subsequently, we will overview common techniques that are considered for interdiction of UASs.

surveillance↗

A full-scope, high-fidelity simulator-based hardware-in-the-loop testbed for comprehensive nuclear power plant cybersecurity research

Nuclear power plant (NPP) cybersecurity research often relies on hardware-in-the-loop (HIL) testbeds that integrate real hardware components into simulated environments. These testbeds allow researchers to identify vulnerabilities, evaluate attack impacts, and test security measures in a controlled setting. Furthermore, previous HIL testbeds lacked fidelity to accurately represent real nuclear systems, limiting the scope of cybersecurity analysis. This study presents the creation of a HIL testbed, devised upon a full-scope, high-fidelity NPP simulator, to facilitate realistic and comprehensive cybersecurity research. To demonstrate its capabilities, the control logic for the steam generator water level was migrated from the simulator to an external programmable logic controller. As a practical application of the developed testbed, supply chain attack scenarios were simulated by injecting malicious code into the controller logic, and the effects of manipulating sensor inputs and control commands were observed. While this HIL testbed provides more detailed simulations, enhanced realism, and wider applicability compared to other options utilizing a less complex simulator, it is also more intricate and costly. For this reason, we include a detailed comparison with some alternative architectures to aid fellow researchers and practitioners in the selection of a suitable HIL architecture based on specific research objectives.

47 OTHER INSTRUMENTATION↗

Smart sensor for online situational awareness in power grids

Waveforms in power grids typically reveal a certain pattern with specific features and peculiarities driven by the system operating conditions, internal and external uncertainties, etc. This prompts an observation of different types of waveforms at the measurement points (substations). An innovative next-generation smart sensor technology includes a measurement unit embedded with sophisticated analytics for power grid online surveillance and situational awareness. The smart sensor brings additional levels of smartness into the existing phasor measurement units (PMUs) and intelligent electronic devices (IEDs). It unlocks the full potential of advanced signal processing and machine learning for online power grid monitoring in a distributed paradigm. Within the smart sensor are several interconnected units for signal acquisition, feature extraction, machine learning-based event detection, and a suite of multiple measurement algorithms where the best-fit algorithm is selected in real-time based on the detected operating condition. Embedding such analytics within the sensors and closer to where the data is generated, the distributed intelligence mechanism mitigates the potential risks to communication failures and latencies, as well as malicious cyber threats, which would otherwise compromise the trustworthiness of the end-use applications in distant control centers. The smart sensor achieves a promising classification accuracy on multiple classes of prevailing conditions in the power grid and accordingly improves the measurement quality across the power grid.

Dehghanian, Payman↗

Resilient Autonomous Wind Farms

With the advent of an increasing number of control strategies that seek to optimize wind turbine performance on a farm level, taking into account individual wind turbine information to achieve wind-farm-level objectives has become an increasingly important goal. Methods for controlling wind turbines on an individual and farm level have experienced significant development, and an abundance of new implementations for gathering and using data from turbines have created potential for novel control mechanisms that can further optimize the performance and delivery characteristics of a wind farm. A key element of making these wind farms more efficient is to develop reliable algorithms that use local sensor information that is already being collected, such as from local meteorological stations, nearby radars, sodars, and lidars, and supervisory control and data acquisition (SCADA) data. Making use of information from all wind turbines in a wind farm can enable such approaches as determining the atmospheric conditions across the farm, improving fault-finding, and ensuring more efficient overall control of farmwide optimizations through mechanisms such as wake steering. However, these approaches typically involve a centralized communications and control center. In order to ensure the resilient operation of the farm, it is necessary to develop an approach that distributes the calculation and communication amongst multiple nodes throughout the farm. In this fashion, a redundant, robust, and secure network can be created, which can tolerate faults in calculation, communication, and even external attacks that seek to disrupt the operation of the wind farm. This paper introduces the use of the Raft-Byzantine-Fault-Tolerant algorithm in the implementation of autonomous control of a wind farm. This implementation will allow for fault tolerance for malfunctioning nodes, sensors, transmitters, and connectors. This approach is equally extensible to account for malicious actors. It will...

fault tolerance↗

Resilient Autonomous Wind Farms: Preprint

With the advent of an increasing number of control strategies that seek to optimize wind turbine performance on a farm-level, taking account of individual wind turbine information to achieve wind farm-level objectives has become an increasingly important goal. Methods for controlling wind turbines on an individual and farm level have seen significant development, and an abundance of new implementations for gathering and using data from turbines have created potential for novel control mechanisms which can further optimize the performance and delivery characteristics of a wind farm. A key element of making these wind farms more efficient is to develop reliable algorithms that use local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. Making use of information from all wind turbines in a wind farm can enable such approaches as determining the atmospheric conditions across the farm, improving fault-finding, and enabling more efficient overall control of farm-wide optimizations through mechanisms such as wake-steering. However, these approaches typically involve a centralized communications and control center. In order to ensure the resilient operation of the farm, it is necessary to develop an approach which distributes the calculation and communication amongst multiple nodes throughout the farm. In this fashion, a redundant, robust, and secure network can be created, which can tolerate faults in calculation, communication, and even external attacks which seek to disrupt the operation of the wind farm. This paper introduces the use of the Raft Byzantine Fault Tolerance algorithm in the implementation of autonomous control of a wind farm. This implementation will allow for fault tolerance for malfunctioning nodes, sensors, transmitters, and connectors. This approach is equally extensible to account for malicious actors. It will be shown to achieve overall consensus, provided the number of faults/malicious nodes is less than 3$n$+1, where $n$ is the number of turbine cluster faults which may occur, and to be robust in the face of multiple arbitrary faults.

autonomous↗

The NREL Sensor Laboratory Detection of Hydrogen Emissions

The development of a functional hydrogen detection system is a multifaceted process that integrates hardware, deployments strategies, and analytics which can be supported by the NREL Sensor Laboratory: 1. Support of the design, validation and optimization of sensing prototypes; 2. Guide optimized sensing element development, including control electronics; 3. Laboratory testing to validate/optimize metrological performance (measurement range, detection limit, etc.); 4. Provide test sites for field deployments representative of real-world scenarios with controlled hydrogen releases; 5. Develop sensor placement and operation guidance; 6. Provide guidance on electronics to accommodate facility integration; 7. Electrical safety designs to allow for operation within restricted zones; 8. Integration into facility monitoring and control systems; 9. Guide incorporation of cyber security elements to protect facilities from malicious attacks; 10. Modeling and application of advanced analytics to detect and quantify emissions; 11. Higher Order dispersion models to guide sensor placement for reliable detection; 12. Advanced analytics for improved metrological performances, and to inform inverse modeling; 13. Market support and commercialization (national and international markets); 14. Commercial deployments in H2@SCALE markets (e.g., HUBs and other large-scale hydrogen markets); and 15. Leverage off international collaborations/partnerships (e.g., NREL is on the advisory board for the European initiative "pre-Normative Research on Hydrogen Releases Assessment"-NHyRA).

08 HYDROGEN↗

A physical unclonable neutron sensor for nuclear arms control inspections

Abstract Classical sensor security relies on cryptographic algorithms executed on trusted hardware. This approach has significant shortcomings, however. Hardware can be manipulated, including below transistor level, and cryptographic keys are at risk of extraction attacks. A further weakness is that sensor media themselves are assumed to be trusted, and any authentication and encryption is done ex situ and a posteriori. Here we propose and demonstrate a different approach to sensor security that does not rely on classical cryptography and trusted electronics. We designed passive sensor media that inherently produce secure and trustworthy data, and whose honest and non-malicious nature can be easily established. As a proof-of-concept, we manufactured and characterized the properties of non-electronic, physical unclonable, optically complex media sensitive to neutrons for use in a high-security scenario: the inspection of a military facility to confirm the absence or presence of nuclear weapons and fissile materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗