Uniaxial wave propagation in a viscoelastic material using measured material properties.
Uniaxial wave propagation in viscoelastic bar due to step displacement at end solved in terms of Fourier sine integral
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Uniaxial wave propagation in viscoelastic bar due to step displacement at end solved in terms of Fourier sine integral
Work directed toward the measurement of materials properties important to the design and interpretation of space processing experiments and determinations of how the space environment may offer a unique opportunity for performing improved measurements and producing materials with improved properties is reported. Surface tensions and their variations with temperature and impurities; convection during undirectional solidification; and measurement of the high temperature thermophysical properties of tungsten group liquids and solids are discussed and results are summarized.
Measurement of materials properties and thermophysical properties is described. The topics discussed are: surface tensions and their variations with temperature and impurities; convection during unidirectional solidification: measurement of high temperature thermophysical properties of tungsten liquid and solid; thermodynamic properties of refractory materials at high temperatures; and experimental and theoretical studies in wetting and multilayer adsorption.
Emittance measurements of space suit face shield and test chip
The theory of a phase insensitive receiver based on acousto-electric effect is presented along with experimental characteristics of a CdS acousto-electric converter (AEC). Since the AEC is nearly phase insensitive, it is ideal for measurements in inhomogeneous materials and/or materials with irregular flatness and parallelism. Through transmission ultrasonic C-scan data of phantom flaws demonstrates a significant improvement in flaw characterization with an AEC over that of a conventional transducer. In addition, measurements with conventional transducers in anisotropically stressed metal samples are shown to lead to grossly inaccurate results due to phase sensitivity. Various other measurements are presented with data contrasting conventional transducers with an AEC in specific NDE applications.
The theory of a phase insensitive receiver based on acousto-electric effect is presented along with experimental characteristics of a CdS acousto-electric converter (AEC). Since the AEC is nearly phase insensitive, it is ideal for measurements in inhomogeneous materials and/or materials with irregular flatness and parallelism. Through transmission ultrasonic C-scan data of phantom flaws demonstrates a significant improvement in flaw characterization with an AEC over that of a conventional transducer. In addition, measurements with conventional transducers in anisotropically stressed metal samples are shown to lead to grossly inaccurate results due to phase sensitivity. Various other measurements are presented with data contrasting conventional transducers with an AEC in specific NDE applications.
Work in support of NASA's Microgravity Science and Applications Program is described. The results of the following three tasks are given in detail: (1) surface tensions and their variations with temperature and impurities; (2) convection during unidirectional solidification; and (3) measurement of high temperature thermophysical properties. Tasks 1 and 2 were directed toward determining how the reduced gravity obtained in space flight can affect convection and solidification processes. Emphasis in task 3 was on development of levitation and containerless processing techniques which can be applied in space flight to provide thermodynamic measurements of reactive materials.
Servo calorimeter accurately measures the heating rate of a material exposed to nuclear radiation independently of the specific heat thermal conductivity of the material. The electrical power used is a direct measure of the nuclear heating rate.
A static and dynamic finite element analysis is conducted on a U.S. Army OH-58 composite tail boom and compared with test data. The tail boom is a filament-wound graphite/epoxy monocoque structure. The structural design of the composite tail boom skin is based on 50-percent graphite fiber volume. However, material tests on representative samples of the tail boom skin reveal that the graphite fiber-volume fraction varied from 44.6 to 49.3 percent. To determine the effect of using measured material properties, static and dynamic finite element analyses are conducted for three fiber-volume conditions of 45, 48, and 50 percent. The static and dynamic model with the 45-percent fiber-volume graphite skins gives the closest agreement with test data.
The electrical conductivities of high voltage insulating materials were measured in the dark and under various intensities of illumination. The materials investigated included FEP Teflon, Kapton-H, fused quartz, and parylene. Conductivities were determined as functions of temperature between 22 and 100 C and light intensity between 0 and 2.5 kW/m2. The thickness dependence of the conductivity was determined for Teflon and Kapton, and the influence of spectral wavelengths on the conductivity was determined in several cases. All measurements were made in a vacuum to simulate a space environment, and all samples had metallic electrodes. The conductivity of Kapton was permanently increased by exposure to light; changes as great as five orders of magnitude were observed after six hours of illumination.
A technique for material parameter determination using an aperture in a groundplane is studied. The material parameters are found by relating the measured reflected field in the aperture to a numerical model. Two apertures are studied which can have a variety of different material configurations covering the aperture. The aperture cross-sections studied are rectangular and coaxial. The material configurations involved combinations of single layer and dual layers with or without a resistive exterior resistive sheet. The resistivity of the resistive sheet can be specified to simulate a perfect electric conductor (PEC) backing (0 Ohms/square) to a free space backing (infinity Ohms/square). Numerical parameter studies and measurements were performed to assess the feasibility of the technique.
Researchers at the NASA Glenn Research Center are evaluating high-temperature materials for Stirling heater heads for second- and third-generation Stirling radioisotope power systems that would help to increase the system efficiency to 30 to 35 percent and the system specific power to 8 to 10+ W/kg. Ceramic materials could make it possible for the convertor hot-end temperature to be increased to 1050 to 1200 C, in comparison to the current 650 C with an Inconel 718 heater head. A hermetically sealed Stirling heater head must retain a constant internal pressure of nearly 400-psi helium (He) throughout its useful life (120,000 hr) at the design operating temperature. Therefore, He permeability was measured for eight potential materials and compared with the permeability of the current heater head material, Inconel 718. The eight materials included silicon nitride (Si3N4), silicon dioxide (SiO2), both sintered and chemical vapor deposited (CVD) silicon carbide (SiC), alumina (Al2O3), two types of melt-infiltrated (MI) SiC/SiC composites, and a carbon/SiC composite (C/SiC). Glenn submitted samples of each material to Porous Materials, Inc., Ithaca, New York, for permeability analysis. At room temperature and 30-psi He, four materials--Si3N4, Al2O3, SiO2, and sintered SiC--demonstrated lower permeability than Inconel 718. The CVD SiC and all the composite materials were significantly more permeable to He than the baseline material.
The design of a pressure vessel with an isothermal volume to measure changes in the natural velocities of material continuously over a wide temperature range is reported. Highly sensitive pulsed phase-locked loop technology is used to measure the natural velocity of fatigued aluminum 2024-T4 as a function of pressure at different temperatures. Second derivative variations with respect to pressure and temperature are found to exhibit order-of-magnitude changes at a gauge pressure near 950 kPa at room temperature. This indicates a significant change in certain combinations of second-order and higher-order elastic constants at relatively low pressures. Fractional frequency change as a function of applied pressure for aluminum 2024-T4 with fatigue damage is illustrated.
The spectral emittances of textured space radiator materials between 1.7 and 14.7 micrometer have been evaluated at room temperature and elevated temperature (630 C) in air. Heating in air caused a permanent increase in spectral emittance for all materials tested: HCl/ion beam textured 304 stainless steel, untextured Ti (6 percent Al, 4 percent V), and sandblasted Ti (6 percent Al, 4 percent V). Changes in the surface chemistry and/or surface morphology of these materials were also observed. Elevated temperature spectral emittance was measured in an argon atmosphere and compared to the measurements in air. Similarity between the room temperature and elevated temperature spectral emittance measurements was also investigated, and limited agreement was found.
The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a function of temperature by differentiating the QCM thermogravimetric analysis data.
NBS work for NASA in support of NASA's Microgravity Science and Applications Program under NASA Government Order H-27954B (Properties of Electronic Materials) covering the period April 1, 1984 to March 31, 1985 is described. The work has been carried out in three independent tasks: Task 1--Surface Tensions and Their Variations with Temperature and Impurities; Task 2--Convention during Unidirectional Solidification; Task 3--Measurement of High Temperature Thermodynamic Properties. The results for each task are given separately in the body of the report.
Measurements in an Auger spectrometer of surface impurity concentrations on liquid gallium showed that the principle impurities were oxygen and carbon. The impurities showed a tendency to collect into plates or clumps. In Pb rich Pb-Sn off eutectic alloys, macrosegration caused by solutal convection was not reduced by vertical or horizontal fields of 0.1 T, but downward solidification virtually eliminated macrosegration in small diameter samples. Phase assemblages of selected compositions on the joints K(Fe0.5 Si-0.5) O2 -SiO2 and KFeO2 - SiO2 were determined over a large range of oxygen partial pressures and the temperature range 800 C to 1400 C.
Explore the source record for details and available documents.