Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources

Power distribution systems are increasingly integrating heterogeneous sensors with varying data reporting rates and types, which pose challenges to achieving observability at the desired temporal resolution of distribution system state estimation (DSSE). Multisensor failures caused by extreme events exacerbate these issues, introducing substantial uncertainties into DSSE. This article proposes a novel solution to these challenges by ensuring high-resolution system observability despite heterogeneous data sources and multisensor failures. First, a deep learning architecture combining long short-term memory (LSTM) and graph convolutional network (GCN) is employed to synchronize meters with different reporting rates, aiming to achieve system observability. A random-walk-model-based approach is introduced to generate pseudo-measurements while properly characterizing their uncertainties under multisensor failures. Finally, a disaster-risk-informed observability metric (RiOM) is defined to quantify the uncertainty associated with state estimation results. The proposed framework offers deeper insights into the system observability on the fly compared with conventional analysis. The effectiveness of the framework is demonstrated on an IEEE standard test case and a large-scale real-world distribution feeder in mid-Minnesota in the U.S.

97 MATHEMATICS AND COMPUTING↗

OpenSAMPL: An Open Source Library for Timing and Synchronization Measurements and Analytics

Today's power grid operators are implementing timing and synchronization solutions that provide resilience to Global Navigation Satellite System (GNSS) vulnerabilities. These vendor-specific solutions often come with additional software applications that are designed to monitor that vendor's synchronization performance data. However, resilient timing architectures often resulting in multi-vendor solutions, including approaches that blend terrestrial clocks with space-based subscription services. In such an environment, collecting, analyzing, and visualizing data from a variety of sources within a single platform was heretofore not possible. To address this need, the US Department of Energy's Center for Alternative Synchronization and Timing (CAST) developed OpenSAMPL, the Open Synchronized Analytics and Monitoring Platform, an open-source Python framework for processing, loading, and observing clock measurement data from distributed devices. OpenSAMPL enables the ingestion of diverse clock-probe sources into a scalable time-series database and applies robust analytics. OpenSAMPL currently supports two vendor data pipelines, and will be extended to more in the near future, enabling seamless monitoring of a variety of timing and synchronization devices in a common environment.

Grant, Josh [ORNL] (ORCID:0000000163475060)↗

Synchronized Phasor Measurement Unit-based Central Controller for Normal and Contingent Operation of a High-Capacity HVDC Macrogrid for the Continental US

This paper presents a Synchronized Phasor Measurement Unit (PMU) based controller to support the coordination and operation of a high-capacity high-voltage direct current (HVDC) macrogrid transmission for the continental US. The proposed controller allows for optimal scheduling of each segment of the multi-terminal HVDC network under normal and contingent conditions, while considering minimum levels of frequency response requirements. The performance of the proposed controller is tested on a 100,222-bus representation of the US Eastern and Western interconnections. Results show that a centralized PMU-based controller improves the frequency nadir of the HVDC macrogrid under contingency conditions by 25.9%. Furthermore, the primary frequency response (PFR) of the HVDC macrogrid is increased by 33.4%. The performance of each interconnection under the largest credible contingency conditions is also discussed.

Mohan, Nihal↗

Precise ROCOF estimation algorithm for low inertia power grids

The precise estimation of Rate Of Change Of Frequencies (ROCOFs) in a generation trip event can be helpful on power system inertia estimation, fast system response, and accurate event capturing. However, the ROCOF estimations from the existing Synchronized Measurement Devices (SMDs) are usually simply calculated by the finite difference between two adjacent frequency measurement points. The ineluctable noises, disturbances, and spikes from real-world frequency measurements can bring large dynamics to the ROCOF estimation and thus can result in an inaccurate estimation of the initial ROCOF. This issue becomes more serious when the target power grid has low inertia, and a large amount of distributed energy sources are deployed. To address this issue, a precise ROCOF estimation algorithm is designed based on least square method with flexible window size. In addition, a median filter is also designed and applied on the frequency measurements before using the proposed algorithm. The window size and thresholds in the proposed algorithm are determined with historical event data analysis. The proposed algorithm is deployed in a low cost, flexible, and distribution level universal grid analyzer (UGA) platform. In conclusion, multiple experiments are conducted in both a laboratory and the Hawaiian Islands to verify the effectiveness of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Graph-Learning-Assisted State and Event Tracking for Solar-Penetrated Power Grids with Heterogeneous Data Sources

Unlike transmission systems, distribution systems do not typically contain sufficient metering to enable real-time state estimation. The lack of sufficient real-time measurements prohibits accurate and timely monitoring of the state of distribution systems. As a result, control and optimal operation of distribution systems, especially those containing large numbers of renewable generation units are not possible without proper data and information about the current state of the system. The main motivation of this project is to address this shortcoming by developing an approach which provides “predicted” real-time measurements so that they can be used to execute a distribution system state estimator. Thus, the objective of the project is to make the distribution systems fully observable, such that the hosting capacity for solar generation can be accurately estimated, and unnecessary solar curtailments can be avoided. In order to accomplish this goal, the project investigated the use of a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams obtained from AMI meters, SCADA as well as PMU measurements and created synchronous measurement snapshots for the state estimator (SE); and developed a hybrid robust SE which provides not only accurate state estimates but also real-time feedback for the ML model refinement.

14 SOLAR ENERGY↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗

Roles of Dynamic State Estimation in Power System Modeling, Monitoring and Operation

—Power system dynamic state estimation (DSE) remains an active research area. This is driven by the absence of accurate models, the increasing availability of fast-sampled, time synchronized measurements, and the advances in the capability, scalability, and affordability of computing and communications. This paper discusses the advantages of DSE as compared to static state estimation, and the implementation differences between the two, including the measurement configuration, modeling framework and support software features. The important roles of DSE are discussed from modeling, monitoring and operation aspects for today’s synchronous machine dominated systems and the future power electronics-interfaced generation systems. Several examples are presented to demonstrate the benefits of DSE on enhancing the operational robustness and resilience of 21st century power system through time critical applications. Future research directions are identified and discussed, paving the way for developing the next generation of energy management systems.

Zhao, Junbo↗

Line Faults Classification Using Machine Learning on Three Phase Voltages Extracted from Large Dataset of PMU Measurements

An end-to-end supervised learning method is developed to classify transmission line faults in a twoyear field-recorded dataset that includes synchronized measurements of three-phase voltages recorded by 38 Phasor Measurement Units (PMU) sparsely located in in the US Western Grid interconnection. Statistical analysis is performed to extract features from this large dataset to train Support Vector Machine (SVM), Random Forest (RF), and eXtreme Gradient Boosting (XGBoost) classifiers initially. The training further leverages a simulated dataset from a synthetic grid with 12 PMUs to increase the number of faults of types infrequently seen in the field-recorded dataset. Training the classification models with the combined dataset resulted in a classification accuracy of 97.7%. This is a significant improvement over 89.7% to 92.5% accuracy obtained by relying on the field-recorded dataset alone.

47 OTHER INSTRUMENTATION↗

Leveraging PMU for Protection and Control

This presentation discusses the application of synchronized measurement in transmission system protection. The proposed wide area system protection (WASP) scheme uses PMU data to perform zonal current differential protection for the whole transmission system with high IBR penetration. This novel protection concept uses synchronized measurement, which is one of the key tasks proposed in the award DE-EE0010655.

14 SOLAR ENERGY↗

In-Situ Blade Strain Measurements and Fatigue Analysis of a Cross-Flow Turbine Operating in a Tidal Flow

Cross-flow turbines (CFTs) are inherently unsteady devices with regards to operating principle and loading. By improving our understanding of the dynamic loading on these turbines, we hope to better inform CFT design, improve survivability, and reduce overall costs. The University of New Hampshire (UNH) and the National Renewable Energy Laboratory (NREL) collaborated on a project to instrument and test a four-bladed New Energy Corp. vertical axis cross-flow turbine in a real tidal flow. One blade from the 3.2 m diameter x 1.7 m height turbine was instrumented with eight full-bridge strain gauges along the span of the blade. The turbine was then deployed at the UNH-Atlantic Marine Energy Center (AMEC) Tidal Energy Test Site in Portsmouth, NH. Time-synchronized measurements of blade strain, inflow, thrust, rotational speed, and electrical output were obtained to characterize blade loading under various conditions. The blade strain was examined to assess the dynamic loading and conduct a fatigue analysis on the device.

blade strain↗

Extended real-time voltage instability identification method based on synchronized phasor measurements

This paper presents an extended adaptive approach designed to accurately estimate the Thévenin equivalent parameters using phasor measurements at a given bus for measurements lying in any of four quadrants of the PQ-plane. The improvement is achieved by using a new condition to properly update the estimated parameters after an initial guess. Based on an adaptive philosophy, the proposed approach can correctly account for the intrinsic nonlinearities of a power system, can provide a real-time estimation of Thévenin parameters, and does not require network topology knowledge. The method is validated using the Kundur 2-area system, showing estimation improvements compared to the current adaptive approach and the classical recursive least-squares method. The proposed approach is able to estimate both sides of the system with respect to the measurement bus. In addition, a data-driven voltage stability index is developed. To illustrate the performance of the proposed approach in a larger power system, a voltage stability assessment is carried out on the IEEE 39-bus system, considering the action of overexcitation limiters of generators and nonlinear loads. The proposed approach is suitable for applications that require an accurate Thévenin equivalent estimation in real-time, such as for voltage stability assessment. The new approach provides a reliable tool for the system operators to make proper and timely decisions.

42 ENGINEERING↗

Short pulsewidth high repetition rate nanosecond transient absorption spectrometer

A high-sensitivity nanosecond to millisecond transient absorption spectrometer for measurements of miniscule signals under low excitation intensities includes an excitation source generating a >100 Hz, <5 ns pulsewidth excitation pulse for exciting a light absorbing sample, a probe light source for generating a high photon flux probe light beam producing an average irradiance greater than 1 μW m-2 nm-1 for measuring the transient absorption spectrum of the sample before and after excitation by the excitation source, a DC-coupled detector capable of measuring light for enabling synchronous measurement of both the transmission of the probe light beam and the change in transmission of the probe light beam between a signal with the excitation pulse present and a signal in the absence of the excitation pulse, and a digital oscilloscope with a trigger rearm time capable of collecting every trigger event at frequencies including 1MHz, for enabling sequential noise subtraction protocols.

Rimshaw, Adam↗

Cyber physical attack detection

A cyber-security threat detection system and method stores physical data measurements from a cyber-physical system and extracts synchronized measurement vectors synchronized to one or more timing pulses. The system and method synthesizes data integrity attacks in response to the physical data measurements and applies alternating parametrized linear and non-linear operations in response to the synthesized data integrity attacks. The synthesis renders optimized model parameters used to detect multiple cyber-attacks.

97 MATHEMATICS AND COMPUTING↗

Cyber physical attack detection

A cyber-security threat detection system and method stores physical data measurements from a cyber-physical system and extracts synchronized measurement vectors synchronized to one or more timing pulses. The system and method synthesize data integrity attacks in response to the physical data measurements and applies alternating parameterized linear and non-linear operations in response to the synthesized data integrity attacks. The synthesis renders optimized model parameters used to detect multiple cyber-attacks.

Ferragut, Erik M.↗

Power System Feature-Based Event Classification by Means of Multiple PMU Data

Abstract—Phasor Measurement Units (PMUs) provide time synchronized measurements across the power grid, enabling data driven event detection and classification for enhanced system monitoring and situational awareness. However, variations in event duration, spatial extent, and severity, along with coincident events, pose challenges for conventional classification models that require fixed-size inputs. This paper presents a feature-based framework that aggregates diverse attributes from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, and Multilayer Perceptron. A probabilistic post-processing scheme is further introduced to enable multi-label classification in the presence of overlapping events. Experiments using real-world PMU data demonstrate that the Random Forest model achieves 95% accuracy, while the proposed post-processing method yields an additional 3% improvement.

Nematirad, Reza↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗