Search NASA⌕ Search

SEARCH · Search NASA

Results for “medical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. In this work, to respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.

60 APPLIED LIFE SCIENCES↗

Replacement of Cobalt in Medical Device Sterilization: Current Trends, Opportunities and Barriers to Adoption of X-ray and E-Beam Within the Medical Device Sterilization Market

Radioactive sources, specifically Co-60, are crucially important to the medical device sterilization industry; however, their benefits must be balanced against the need to ensure that the materials are secure. Accelerator-based sterilization methods, including X-ray and E-Beam, can in many cases sufficiently replace Co-60 and ethylene oxide, the dominant modalities currently in use; however, a lack of hands-on experience with accelerators, regulations, and a lack of capacity have hampered faster adoption of these technologies. The market is likely to change, however, given public pressures against ethylene oxide and concerns over the cost and long-term supply chain robustness of Co-60. This may provide an opportunity for growth for accelerator capabilities. Current research at Sandia National Laboratories and Argonne National Laboratory, on behalf of the Department of Energy’s National Nuclear Security Administration Office of Radiological Security, is focused on developing an understanding of the medical device sterilization marketplace, the different modalities that are used to sterilize goods, and the drivers that affect the actors within it. Research at Pacific Northwest National Laboratory, in conjunction with the medical device sterilization industry, has focused on expanding the industry’s understanding of the capabilities of X-ray sterilization and developing data that can inform the industry’s consideration of a transition towards accelerator-based devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing Patient-Specific Medication Regimen Policies Using Wearable Sensors in Parkinson’s Disease

Effective treatment of Parkinson’s disease (PD) is a continual challenge for healthcare providers, and providers can benefit from leveraging emerging technologies to supplement traditional clinic care. We develop a data-driven reinforcement learning (RL) framework to optimize PD medication regimens through wearable sensors. We leverage a data set of n = 26 PD patients who wore wrist-mounted movement trackers for two separate six-day periods. Using these data, we first build and validate a simulation model of how individual patients’ movement symptoms respond to medication administration. We then pair this simulation model with an on-policy RL algorithm that recommends optimal medication types, timing, and dosages during the day while incorporating human-in-the-loop considerations on medication administration. The results show that the RL-prescribed medication regimens outperform physicians’ medication regimens, despite physicians having access to the same data as the RL agent. To validate our results, we assess our wearable-based RL medication regimens using n = 399 PD patients from the Parkinson’s Progression Markers Initiative data set. We show that the wearable-based RL medication regimens would lead to significant symptom improvement for these patients, even more so than training RL policies directly from this data set. In doing so, we show that RL models from even small data sets of wearable data can offer novel, generalizable clinical insights and medication strategies, which may outperform those derived from larger data sets without wearable data.

60 APPLIED LIFE SCIENCES↗

State and Regional Variation in Prescription- and Payment-Related Promoters of Adherence to Blood Pressure Medication

Introduction: Medication adherence can improve hypertension management. How blood pressure medications are prescribed and purchased can promote or impede adherence. Methods: We used comprehensive dispensing data on prescription blood pressure medication from Symphony Health’s 2017 Integrated Dataverse to assess how prescription- and payment-related factors that promote medication adherence (ie, fixed-dose combinations, generic formulations, mail order, low-cost or no-copay medications) vary across US states and census regions and across the market segments (grouped by patient age, prescriber type, and payer type) responsible for the greatest number of blood pressure medication fills. Results: In 2017, 706.5 million prescriptions for blood pressure medication were filled, accounting for $29.0 billion in total spending (17.0% incurred by patients). As a proportion of all fills, factors that promoted adherence varied by state: fixed-dose combinations (from 5.8% in Maine to 17.9% in Mississippi); generic formulations (from 95.2% in New Jersey to 98.4% in Minnesota); mail order (from 4.7% in Rhode Island to 14.5% in Delaware); and lower or no copayment (from 56.6% in Utah to 72.8% in California). Furthermore, mean days’ supply per fill (from 43.1 in Arkansas to 63.8 in Maine) and patient spending per therapy year (from $38 in Hawaii to $76 in Georgia) varied. Concentration of adherence factors differed by market segment. Patients aged 18 to 64 with a primary care physician prescriber and Medicaid coverage had the lowest concentration of fixed-dose combination fills, mean days’ supply per fill, and patient spending per therapy year. Patients aged 65 years or older with a primary care physician prescriber and commercial insurance had the highest concentration of fixeddose combinations fills and mail order fills. Conclusion: Addressing regional and market segment variation in factors promoting blood pressure medication adherence may increase adherence and improve hypertension management.

60 APPLIED LIFE SCIENCES↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DOME: Directional medical embedding vectors from Electronic Health Records

Motivation: The increasing availability of Electronic Health Record (EHR) systems has created enormous potential for translational research. Recent developments in representation learning techniques have led to effective large-scale representations of EHR concepts along with knowledge graphs that empower downstream EHR studies. However, most existing methods require training with patient-level data, limiting their abilities to expand the training with multi-institutional EHR data. On the other hand, scalable approaches that only require summary-level data do not incorporate temporal dependencies between concepts. Methods: We introduce a DirectiOnal Medical Embedding (DOME) algorithm to encode temporally directional relationships between medical concepts, using summary-level EHR data. Specifically, DOME first aggregates patient-level EHR data into an asymmetric co-occurrence matrix. Then it computes two Positive Pointwise Mutual Information (PPMI) matrices to correspondingly encode the pairwise prior and posterior dependencies between medical concepts. Following that, a joint matrix factorization is performed on the two PPMI matrices, which results in three vectors for each concept: a semantic embedding and two directional context embeddings. They collectively provide a comprehensive depiction of the temporal relationship between EHR concepts. Results: We highlight the advantages and translational potential of DOME through three sets of validation studies. First, DOME consistently improves existing direction-agnostic embedding vectors for disease risk prediction in several diseases, for example achieving a relative gain of 5.5% in the area under the receiver operating characteristic (AUROC) for lung cancer. Second, DOME excels in directional drug-disease relationship inference by successfully differentiating between drug side effects and indications, correspondingly achieving relative AUROC gain over the state-of-the-art methods by 10.8% and 6.6%. Finally, DOME effectively constructs directional knowledge graphs, which distinguish disease risk factors from comorbidities, thereby revealing disease progression trajectories. The source codes are provided at https://github.com/celehs/Directional-EHRembedding.

60 APPLIED LIFE SCIENCES↗

Deformable phrase level attention: A flexible approach for improving AI based medical coding

Objective: Improving the AI-driven automated medical encoding of clinical text plays a vital role in gathering information on the occurrence of diseases to improve population-level health. This work presents a novel attention mechanism designed to enhance text classification models and ensure appropriate classification of medical concepts in unstructured electronic health records. Materials and Methods: We developed a deformable, phrase-level attention mechanism to identify important lexical word-level and contextual phrase-level information from clinical text documents. We evaluated conventional and transformer-based deep learning models that we extended with our attention mechanism on the extraction of critical cancer information (e.g., site, subsite, laterality, histology, behavior) from 629,908 electronic pathology reports and on the automated medical encoding of 52,722 hospital discharge summaries. Results: Transformer-based models with the deformable, phrase-level attention mechanism achieved the best performance on the extraction of critical cancer information from pathology reports. Conventional- and transformer-based models show similar or better performance than their baseline counterparts on the automated medical encoding of clinical documents. Discussion: The addition of phrase-level information allowed models extended with our proposed method to outperform standard word-level attention. Our method showed favorable properties for the real-world application in terms of model robustness and phenotyping. These results indicate that our method is promising for automated data harmonization for common data models. Conclusion: This work proposes a novel deformable, phrase-level attention mechanism that enhances text classification models in the extraction of medical concepts from clinical text documents. We demonstrate strong performances on two clinical text datasets and showcase real-world deployability of our method.

Automated medical encoding↗

Improving Medication Regimen Recommendation for Parkinson’s Disease Using Sensor Technology

Parkinson’s disease medication treatment planning is generally based on subjective data obtained through clinical, physician-patient interactions. The Personal KinetiGraph™ (PKG) and similar wearable sensors have shown promise in enabling objective, continuous remote health monitoring for Parkinson’s patients. In this proof-of-concept study, we propose to use objective sensor data from the PKG and apply machine learning to cluster patients based on levodopa regimens and response. The resulting clusters are then used to enhance treatment planning by providing improved initial treatment estimates to supplement a physician’s initial assessment. We apply k-means clustering to a dataset of within-subject Parkinson’s medication changes—clinically assessed by the MDS-Unified Parkinson’s Disease Rating Scale-III (MDS-UPDRS-III) and the PKG sensor for movement staging. A random forest classification model was then used to predict patients’ cluster allocation based on their respective demographic information, MDS-UPDRS-III scores, and PKG time-series data. Clinically relevant clusters were partitioned by levodopa dose, medication administration frequency, and total levodopa equivalent daily dose—with the PKG providing similar symptomatic assessments to physician MDS-UPDRS-III scores. A random forest classifier trained on demographic information, MDS-UPDRS-III scores, and PKG time-series data was able to accurately classify subjects of the two most demographically similar clusters with an accuracy of 86.9%, an F1 score of 90.7%, and an AUC of 0.871. A model that relied solely on demographic information and PKG time-series data provided the next best performance with an accuracy of 83.8%, an F1 score of 88.5%, and an AUC of 0.831, hence further enabling fully remote assessments. These computational methods demonstrate the feasibility of using sensor-based data to cluster patients based on their medication responses with further potential to assist with medication recommendations.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Public Health Response and Medical Management of Internal Contamination in Past Radiological or Nuclear Incidents: A Review

Following a radiological or nuclear emergency, workers, responders and the public may be internally contaminated with radionuclides. Screening, monitoring and assessing any internal contamination and providing necessary medical treatment, especially when a large number of individuals are involved, is challenging. Experience gained and lessons learned from the management of previous incidents would help to identify gaps in knowledge and capabilities on preparedness for and response to radiation emergencies. In this paper, eight largescale and five workplace radiological and nuclear incidents are reviewed cross 14 technical areas, under the broader topics of emergency preparedness, emergency response and recovery processes. The review findings suggest that 1) new strategies, algorithms and technologies are explored for rapid screening of large populations; 2) exposure assessment and dose estimation in emergency response and dose reconstruction in recovery process are supported by complementary sources of information, including ‘citizen science’; 3) surge capacity for monitoring and dose assessment is coordinated through national and international laboratory networks; 4) evidence-based guidelines for medical management and follow-up of internal contamination are urgently needed; 5) mechanisms for international and regional access to medical countermeasures are investigated and implemented; 6) long-term health and medical follow up programs are designed and justified; and 7) capabilities and capacity developed for emergency response are sustained through adequate resource allocation, routine nonemergency use of technical skills in regular exercises, training, and continuous improvement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Survey of Image Denoising Methods for Medical Image Classification

Medical imaging devices, such as X-ray machines, inherently produce images that suffer from visual noise. Our objectives were to (i.) determine the effect of image denoising on a medical image classification task, and (ii.) determine if there exists a correlation between image denoising performance and medical image classification performance. We performed the medical image classification task on chest X-rays using the DenseNet-121 convolutional neural network (CNN) and used the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) metrics as the image denoising performance measures. We first found that different denoising methods can make a statistically significant difference in classification performance for select labels. We also found that denoising methods affect fine-tuned models more than randomly-initialized models and that fine-tuned models have significantly higher and more uniform performance than randomly-initialized models. Lastly, we found that there is no significant correlation between PSNR and SSIM values and classification performance for our task.

Michael, Peter↗

A New Process for Small-Batch Purification of the Medical Isotope Molybdenum-99: Non-Technical Overview

The U.S. medical community depends on a reliable supply of the radioisotope molybdenum-99 (Mo-99) for nuclear medical diagnostic procedures. Mo-99's decay product, technetium-99m (Tc-99m), is used in over 40,000 medical procedures in the United States each day to diagnose heart disease and cancer, to study organ structure and function, and to perform other important medical applications. For example, patients undergoing a common procedure—the cardiac “stress test”—likely have benefited from Tc-99m. Historically, Mo-99 was primarily produced through the fission of uranium-235, in the form of highly enriched uranium (HEU) targets irradiated in research and test reactors. HEU is a proliferation-sensitive material that, if diverted or stolen, could be used as a component of a nuclear weapon. NNSA’s Office of Material Management and Minimization (M3) manages the Molybdenum-99 (Mo-99) Program as part of its mission to minimize the use of HEU in civilian applications. The Mo-99 Program assists global Mo-99 production facilities in converting to non-HEU processes and supports the establishment of domestic supplies of Mo-99 without the use of proliferation-sensitive HEU. As part of this program, M3 funds U.S. national laboratories to provide non-proprietary technical support to U.S. companies working to establish non-HEU-based Mo-99 production capabilities. The results of this research are published on OSTI.gov for the benefit of the Mo-99 community and the public. However, it can be difficult for readers without a scientific background to understand and interpret these publications. In order to increase public understanding of the work being done in M3’s Mo-99 Program, this paper aims to provide an overview of a key, recent national laboratory technical publication in terms that can be understood by readers without a technical background. To accomplish this, the paper first explains key scientific concepts—primarily related to chemistry—that provide a foundation for understanding research in this area. This includes chromatography, absorption vs. adsorption, dissolution and precipitation, and liquid-liquid extraction. Drawing on these concepts, the paper then provides an explanation for non-technical audiences of the Argonne National Laboratory publication entitled Recovery of High Specific Activity Molybdenum-99 from Accelerator-Induced Fission on Low-Enriched Uranium for Technetium-99m Generators (Brown, M.A. et al., 2021) and related article Separation and Purification of Mo-99 Produced from Natural U3O8 Targets via Photo-Fission (Brown, M.A. et al., 2021).

Stamler, Bradley↗

MedNAS: Multiscale Training-Free Neural Architecture Search for Medical Image Analysis

Deep neural networks have demonstrated impressive results in medical image analysis, but designing suitable architectures for each specific task is expertise dependent and time consuming. Neural architecture search (NAS) offers an effective means of discovering architectures. It has been highly successful in numerous applications, particularly in natural image classification. Yet, medical images possess unique characteristics, such as small regions and a wide variety of lesion sizes, that differentiate them from natural images. Furthermore, most current NAS methods struggle with high computational costs, especially when dealing with high-resolution image datasets. In this article, we present a novel evolutionary NAS method called multiscale training-free neural architecture search (MSTF-NAS) to address these challenges. Specifically, to accommodate the broad range of lesion region sizes in disease diagnosis, we develop a new reduction cell search space that enables the search algorithm to explicitly identify the optimal scale combination for multiscale feature extraction. Further, to overcome the issue of high computational costs, we utilize training-free indicators as performance measures for candidate architectures, which allows us to search for the optimal architecture more efficiently. More specifically, by considering the capability and simplicity of various networks, we formulate a multiobjective optimization problem that involves two training-free indicators and model complexity for candidate architectures. Extensive experiments on a large medical image benchmark and a publicly available breast cancer detection dataset are conducted. The empirical results demonstrate that our MSTF-NAS outperforms both human-designed architectures and current state-of-the-art NAS algorithms on both datasets, indicating the effectiveness of our proposed method.

60 APPLIED LIFE SCIENCES↗

Report on the AAPM grand challenge on deep generative modeling for learning medical image statistics

Abstract Background The findings of the 2023 AAPM Grand Challenge on Deep Generative Modeling for Learning Medical Image Statistics are reported in this Special Report. Purpose The goal of this challenge was to promote the development of deep generative models for medical imaging and to emphasize the need for their domain‐relevant assessments via the analysis of relevant image statistics. Methods As part of this Grand Challenge, a common training dataset and an evaluation procedure was developed for benchmarking deep generative models for medical image synthesis. To create the training dataset, an established 3D virtual breast phantom was adapted. The resulting dataset comprised about 108 000 images of size 512 512. For the evaluation of submissions to the Challenge, an ensemble of 10 000 DGM‐generated images from each submission was employed. The evaluation procedure consisted of two stages. In the first stage, a preliminary check for memorization and image quality (via the Fréchet Inception Distance [FID]) was performed. Submissions that passed the first stage were then evaluated for the reproducibility of image statistics corresponding to several feature families including texture, morphology, image moments, fractal statistics, and skeleton statistics. A summary measure in this feature space was employed to rank the submissions. Additional analyses of submissions was performed to assess DGM performance specific to individual feature families, the four classes in the training data, and also to identify various artifacts. Results Fifty‐eight submissions from 12 unique users were received for this Challenge. Out of these 12 submissions, 9 submissions passed the first stage of evaluation and were eligible for ranking. The top‐ranked submission employed a conditional latent diffusion model, whereas the joint runners‐up employed a generative adversarial network, followed by another network for image superresolution. In general, we observed that the overall ranking of the top 9 submissions according to our evaluation method (i) did not match the FID‐based ranking, and (ii) differed with respect to individual feature families. Another important finding from our additional analyses was that different DGMs demonstrated similar kinds of artifacts. Conclusions This Grand Challenge highlighted the need for domain‐specific evaluation to further DGM design as well as deployment. It also demonstrated that the specification of a DGM may differ depending on its intended use.

Radiology, Nuclear Medicine & Medical Imaging↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗