Search NASA⌕ Search

SEARCH · Search NASA

Results for “membranes thickness monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In-Line Membrane Thickness Mapping with Real-Time Data Processing

The goal of this project is commercialization of a novel, patented by NREL, non-contact, in-line quality control thickness mapping tool that will enable 100% area inspection of multilayer polymer film assemblies, such as a PEM on a casting substrate, during continuous high-volume R2R manufacturing.

ENGINEERING,HYDROGEN↗

Effect of skin flexibility on aerodynamic performance of flexible skin flapping wings for micro air vehicles

As part of the ongoing research on micro air vehicles, the present work focuses on the effect of membrane flexibility on the aerodynamic performance of flexible latex flapping wings. Wings with membrane thicknesses 0.37, 0.28, and 0.13 mm are chosen, which are named as least flexible (A), flexible (B), and most flexible (C), respectively. The experiments are performed in an air chamber of size 1.5 m × 1.5 m × 1.5 m, facilitated with wind velocities up to 15 m/s. The time-averaged lift and drag as functions of flapping frequency, forward flight velocity, the angles of attack (AoA), and advance ratio (J). The novel electronic control system developed previously is used to monitor and measure the flapping frequency. It is found that the effect of flexibility on the aerodynamic performance mainly depends on the range of flight speed; at 7200 ≤ Re ≤ 18,000, the lift and drag increase with increase of flexibility, and at 18,000 ≤ Re ≤ 25,200, the lift decreases and drag increases with increase of flexibility. Hence latex compliant (Wing C) wings are advantageous in the low Re range, while the least flexible wing (Wing A) is preferable for higher range.

42 ENGINEERING↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

Membrane Thickness Impact on Chemical Degradation Rates

Abstract A comprehensive investigation of PFSA membrane chemical degradation rates as a function of thickness (8-20 µm) is reported. The two-pronged study was conducted on bare membranes and as components of chemically-mitigated and mechanically-reinforced, state-of-the-art (SOA) membrane electrode assemblies (MEAs). The bare membranes were subjected to H2O2 vapor test and MEAs were degraded under OCV conditions, both at 90°C. Both test types employed fluoride release rates (FRR) to monitor chemical degradation rates. Vapor tests revealed that area-specific degradation rates were positively correlated with membrane thickness, but thickness normalized degradation rates were independent of thickness. Open-circuit voltage (OCV) investigations spanning the membrane thickness series of MEAs was probed via a 27-experiment 3(4-1) fractional factorial experimental design. Statistical analysis of the FRR values revealed that chemical degradation rates were dominated by the relative humidity value and that the area-specific degradation rates of MEAs were independent of membrane thickness. The OCV chemical durability insensitivity to membrane thickness is supported by on-load membrane chemical durability studies at the stack level. The results suggest that ,despite smaller ionomer inventory, SOA thin membranes and MEAs are not greatly disadvantaged relative to thicker membranes from a chemical durability perspective, provided oxidative stress levels are controlled throughout application lifetime.

Coms, Frank D. (ORCID:0000000249160350)↗

The joint influence of albedo and insulation on roof performance: An observational study

We focus on understanding the temperature and heat flux fields in building roofs, and how they are modulated by the interacting influences of albedo and insulation at annual, seasonal and diurnal scales. High precision heat flux plates and thermocouples were installed over multiple rooftops of varying insulation thickness and albedo in the Northeastern United States to monitor the temperature and the heat flux into and out of the roof structures for a whole year. This analysis shows that while membrane reflectivity (albedo) plays a dominant role in reducing the heat conducted inward through the roof structures during the warmer months, insulation thickness becomes the main roof attribute in preventing heat loss from the buildings during colder months. On a diurnal scale, the thermal state of the white roof structures fluctuated little compared to black roof structures; membrane temperature over white roofs ranged between 10 °C and 45 °C during summer months compared to black membranes that ranged between 10 °C and 80 °C. Insulation thickness, apart from reducing the heat conducted through the roof structure, also delayed the transfer of heat, owing to the thermal inertia of the insulation layer. Furthermore, this has important implications for determining the peak heating and cooling times.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Zone Plate Properties using Monochromatic Synchrotron Radiation in the 2 to 20 nm Wavelength Range

A zone plate composed of Mo zones having 4 mm outermost zone diameter, 100 nm outermost zone width, and supported on a silicon nitride membrane was characterized using monochromatic synchrotron radiation in the 2 to 20 nm wavelength range. The zero and first order efficiencies were measured and compared to ab initio calculations that account for the optical properties of the materials, the width and shape of the zones, and multiple-layer thin-film effects. It is shown that the thicknesses of the Mo zones and the membrane and the ratio of the zone width to zone period can be independently determined from the measured diffraction efficiencies in the zero and first orders and that the computational code can be used to reliably design zone plates that are optimized for applications such as solar irradiance monitors in the extreme ultraviolet region.

36 MATERIALS SCIENCE↗

Investigating Li Microstructure Formation on Li Anodes for Lithium Batteries by $In Situ$ 6 Li/ 7 Li NMR and SEM

The growth of lithium microstructures during battery cycling has, to date, prohibited the use of Li metal anodes and raises serious safety concerns even in conventional lithium-ion rechargeable batteries, particularly if they are charged at high rates. The electrochemical conditions under which these Li microstructures grow have, therefore, been investigated by in situ nuclear magnetic resonance (NMR), scanning electron microscopy (SEM), and susceptibility calculations. Lithium metal symmetric bag cells containing LiPF 6 in EC/DMC electrolytes were used. Distinct 7 Li NMR resonances were observed due to the Li metal bulk electrodes and microstructures, the changes in peak positions and intensities being monitored in situ during Li deposition. The changes in the NMR spectra, observed as a function of separator thickness and porosity (using Celgard and Whatmann glass microfiber membranes) and different applied pressures, were correlated with changes in the type of microstructure, by using SEM. Isotopically enriched 6 Li metal electrodes were used against natural abundance predominantly 7 Li metal counter electrodes to investigate radiofrequency (rf) field penetration into the Li anode and to confirm the assignment of the higher frequency peak to Li dendrites. The conclusions were supported by calculations performed to explore the effect of the different microstructures on peak position/broadening, the study showing that Li NMR spectroscopy can be used as a sensitive probe of both the amount and type of microstructure formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wireless and chip-less passive radiation sensors for high dose monitoring

The safety of nuclear infrastructures may involve the monitoring of many parameters in harsh environments (high radiation level, high temperature, high pressure,..). If technological solutions exist for transducers part in such environments, the electronic part used in reader is not appropriate and still a challenging task. Well-known solutions to remove the electronic part from the harsh environment consist of connecting the transducer and the reader by long electrical wires or performing ex situ remote sensing. However wires may practically be difficult to implement while ex situ measurements are not compatible with on line monitoring. Wireless and passive sensors working in harsh environments could be an appropriate solution for the remote sensing of critical parameters. Passive sensors without electronics in the sensing unit are available (e.g., SAW sensors) but they suffer from short reading range (typically lower than 10 meters). In order to overcome this range limitation a new class of electromagnetic transducers was developed in the mid-2000's. The operating principle is based on the modification of the properties of high-frequency (>> 1 GHz) passive electromagnetic devices by the quantity to be measured. Based on this principle a wide range of sensing properties can be addressed and a large number of materials can be chosen. Moreover the use of high frequency allows reducing the size of the sensor elements (antenna, transducer) and enhancing the immunity to multi-path. Several principles of RF transducers have been already validated by LAAS-CNRS (e;g; pressure, temperature, stress) as well as radar-based solution for the wireless long-range sensors interrogation. The sensor dosimeter exploit here the known property of Hydrogen-Pressure Dosimeters (HPD) for which the polymer material dehydrogenates under nuclear irradiation. The transducer principle is described. The irradiation will generate the out-gazing (hydrogen) of the polymer inside a micro-chamber. The resulting overpressure leads to the deflection of a silicon membrane which modifies the resonant frequency of the RF resonator. Tests structures have been designed in order to quantify the HDPE out-gazing inside a micro-cavity by measuring the deflection of a boss silicon membrane with a mechanical profiler. A specific set up using interferometry method has been also developed to evaluate the pressure generated inside the micro-cavity. The procedure consists in applying a pressure that pushes the membrane to recover a flat membrane. This condition is monitored thanks to the extinction of the Newton rings. Irradiations have been performed up to 30 kGy using 6 MeV focused e-beam providing by electron accelerator. Membrane deflection and generated pressure around 0.2 μm/mg{sub HDPE}/kGy and 70 mbar/mg{sub HDPE}/kGy has been obtained for a 70 μm thick membrane. In order to characterize the hermetic sealing of the micro-chamber under hydrogen over-pressure, membrane deflection after irradiation has been recorded during 50 days. The variations of membrane deflection are randomly distributed and generally lower than ±5%, showing a good hermeticity during this period. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collaboration on SBIR/TTO Phase II Project for Optical QC Device and Collaboration on SBIR/TTO Phase II-b Project for Advanced Quality Inspection Device Development: Cooperative Research and Development CRADA Number CRD-16-00652 (Final Report)

The overall goal of this program is to develop and commercialize a turnkey quality control solution for the entire PEM fuel cell manufacturing process including membrane, gas diffusion layers, catalyst, and assembled systems. This quality control solution is unique to each customer’s specific needs but includes a suite of in-line quality control systems for roll-to-roll manufacturing that can target thin, transparent membrane as well as opaque membrane, catalyst, and GDLs. The Phase II developed the CPNUVV system for thin, transparent membrane that operates using polarized filters to enhance defect resolution and determine thickness. However, PEM material manufacturers want a complete, turnkey solution for all components of the PEM fuel cell. In the Phase IIB, Mainstream will partner with NREL, and transition reflectance technology NREL developed (US Patent 9,234,843) to operate in real-time on a web-line to develop a total solution to PEM quality control. The device will identify and mark defects as well as monitor materials thickness in real-time to improve line efficiency and to reduce waste. The research performed at NREL under this CRADA increases the basis of knowledge about optical inspection methods, how they perform with regards to fuel cell component materials, and how they can be implemented in in-line, real-time configurations to provide quality inspection for roll-to-roll (R2R) manufacturing. Methods explored were found to be sensitive to catalyst loading in electrodes on both membrane and gas diffusion media substrates and to membrane thickness, across a broad range of thickness. The latter capability is novel and now patented and provides a previously unstudied and undemonstrated capability for R2R manufacturing of membranes.

30 DIRECT ENERGY CONVERSION↗

Diamond as a solid state micro-fission chamber for thermal neutron detection at the VR-1 research reactor

Diamond exhibits a combination of properties which makes it attractive for neutron detection in hostile conditions. In the particular case of detection in a nuclear reactor, it is resilient to radiation, exhibits a natural low sensitivity to gamma rays, and its small size (as compared with that of gas ionisation chambers) enables fluency monitoring with a high position resolution. We report here on the use of synthetic CVD diamond as a solid state micro-fission chamber with U-235 converting material for in-core thermal neutron monitoring. Two types of thin diamond detectors were developed for this application. The first type of detector is fabricated using thin diamond membrane obtained by etching low-cost commercially available single crystal CVD intrinsic diamond, so called 'optical grade' material. Starting from a few hundred of micrometre thick samples, the sample is sliced with a laser and then plasma etched down to a few tenths of micrometre. Here we report the result obtained with a 17 μm thick device. The detection surface of this detector is equal to 1 mm{sup 2}. Detectors with surfaces up to 1 cm{sup 2} can be fabricated with this technique. The second type of detector is fabricated by growing successively two thin films of diamond, by the microwave enhanced chemical vapour deposition technique, on HPHT single crystal diamond. A first, a film of boron doped (p+) single crystal diamond, a few microns thick, is deposited. Then a second film of intrinsic diamond with a thickness of a few tens of microns is deposited. This results in a P doped, Intrinsic, Metal structure (PIM) structure in which the intrinsic volume id the active part of the detector. Here we report the results obtained with a 20 μm thick intrinsic whose detection surface is equal to 0.5 mm{sup 2}, with the possibility to enlarge the surface of the detector up to 1 cm{sup 2}. These two types of detector were tested at the VR-1 research reactor at the Czech Technical University in Prague. The Training Reactor VR-1 is a pool type (light water) reactor based on UO{sub 2} low enriched uranium. It has a nominal power of 1 kW, and can be operated for a short period up to 5 kW. The arrangement of the reactor pool reactor facilitates access to the core, setting and removal of various experimental samples and detectors, and safe and easy handling of fuel assemblies. The reactor is equipped with two horizontal channels (radial and tangential) and 10 vertical channels, of varying diameters, which can be loaded into various core positions, and one pneumatic transfer system. It is also equipped with several specifically designed educational instrumentation systems that can be used to supply complementary measurements and characterization around the reactor. The reactor is operated by the Department of Nuclear Reactors of the Faculty of Nuclear Sciences and Physical Engineering of the Czech Technical University in Prague. The two detectors were placed in-core through one of the vertical insertion channel. They were coupled to remote placed (5 m BNC cable) classical nuclear charge sensitive electronics. Detection properties of both sensors, including: pulse height spectra of U-235 fission fragments (response linearity with neutron flux, count rate, gamma background, were evaluated varying the power of the reactor from 0.005 W to 500 W. The evolution of the counting rate of the thinned optical grade detector as a function of counting rate of a gas ionization chamber used currently for reactor monitoring shows the very good linearity of the detector over the 5 decades. Similar results were obtained with the PIM detector. Additionally fast transient current signals of the detectors were recorded on a digital storage oscilloscope (DSO) using broad-band amplifier and with a simple bias-T, showing potential use of such sensors for neutron counting with no need of an amplification stage, since non-amplified signals from fission fragments exceeded 4 mV in amplitude. Therefore, one can think of simple neutron counting system by feeding diamond detectors signals directly to the low threshold discriminators. The results obtained on the VR1 will be described and discussed in detail in the paper and associated presentation. The results demonstrate that diamond micro-fission chambers can be used for in-core neutron monitoring, where robust, simple and compact devices are required.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Longitudinal impact of cylindrical shells.

The transient response due to longitudinal impact of three aluminum cylindrical shells of different thickness-to-radius ratios is studied both analytically and experimentally. The analyses were obtained from method of characteristics' solutions of two sets of equations: one which includes the transverse shear, radial inertia, and rotary inertial effects; and the other set is from a modified membrane theory. Experimentally, longitudinal and circumferential strains are monitored along the length of each of the shells; the velocity of the impacter ring is also measured. The experimental results of this study indicate that the wave front, after traveling three diameters from the impacted end, propagates at essentially the plate velocity, in agreement with the theory. In addition, the longitudinal and circumferential strain calculated from the two theories are in good agreement with the experimental results.

Mortimer, R. W.↗

Reversible Lifting of Surface Supported Lipid Bilayers with a Membrane-Spanning Nonionic Triblock Copolymer

Neutron reflectometry was used to monitor structural variations in surface supported DMPC bilayers induced by the addition of Triton X-100, a surfactant commonly used to aid solubilization of membrane proteins, and the co-addition of a membrane spanning non-ionic amphiphilic triblock copolymer, (PEO 117 -PPO 47 -PE O117 , Pluronic F98). Surfactant addition causes slight compression of the bilayer thickness and the creation of a distinct EO layer that increases the hydrophilic layer proximal to the supporting substrate (i.e., a water and EO gap between the lipid bilayer and quartz) to 6.8 ± 0.4 Å. Addition of the triblock copolymer into the DMPC: Triton X-100 bilayer increases the complexity (broadens) the lipid phase transition, further compresses the bilayer, and continues to expand the proximal hydrophilic layer thickness. The observed structural changes are temperature dependent with transmembrane polymer insertion achieved at 37 °C leading to a compressed membrane thickness of 39.2 ± 0.2 Å and proximal gap of 45.2 ± 0.2 Å. Temperature driven exclusion of the polymer at 15 °C causes partitioning of the polymer into the proximal space generating a large hydrogel cushion 162 ± 16 Å thick. An intermediate gap width (10 – 27 Å) is achieved at room temperature (22 – 25 °C). The temperature-driven changes in the proximal hydrophilic gap dimensions are shown to be reversible but thermal history causes variation in magnitude. Temperature-driven changes in polymer association with a supported lipid bilayer offer a facile means to reversibly control both the membrane characteristics as well as the separation between membrane and solid substrate.

36 MATERIALS SCIENCE↗

Nanoscale Control of Homoepitaxial Growth on a Two-Dimensional Zeolite

Nanoscale crystal growth control is crucial for tailoring two-dimensional (2D) zeolites (crystallites with thickness less than two unit cells) and thicker zeolite nanosheets for applications in separation membranes and as hierarchical catalysts. However, methods to control zeolite crystal growth with nanometer precision are still in their infancy. Herein, we report solution-based growth conditions leading to anisotropic epitaxial growth of 2D zeolites with rates as low as few nanometers per day. Contributions from misoriented surface nucleation and rotational intergrowths are eliminated. Growth monitoring at the single-unit-cell level reveals novel nanoscale crystal-growth phenomena associated with the lateral size and surface curvature of 2D zeolites.

Shete, Meera↗

Portable Apparatus for Electrochemical Sensing of Ethylene

A small, lightweight, portable apparatus based on an electrochemical sensing principle has been developed for monitoring low concentrations of ethylene in air. Ethylene has long been known to be produced by plants and to stimulate the growth and other aspects of the development of plants (including, notably, ripening of fruits and vegetables), even at concentrations as low as tens of parts per billion (ppb). The effects are magnified in plant-growth and -storage chambers wherein ethylene can accumulate. There is increasing recognition in agriculture and related industries that it is desirable to monitor and control ethylene concentrations in order to optimize the growth, storage, and ripening of plant products. Hence, there are numerous potential uses for the present apparatus in conjunction with equipment for controlling ethylene concentrations. The ethylene sensor is of a thick-film type with a design optimized for a low detection limit. The sensor includes a noble metal sensing electrode on a chip and a hydrated solid-electrolyte membrane that is held in contact with the chip. Also located on the sensor chip are a counter electrode and a reference electrode. The sensing electrode is held at a fixed potential versus the reference electrode. Detection takes place at active-triple-point areas where the sensing electrode, electrolyte, and sample gas meet. These areas are formed by cutting openings in the electrolyte membrane. The electrode current generated from electrochemical oxidation of ethylene at the active triple points is proportional to the concentration of ethylene. An additional film of the solid-electrolyte membrane material is deposited on the sensing electrode to increase the effective triple-point areas and thereby enhance the detection signal. The sensor chip is placed in a holder that is part of a polycarbonate housing. When fully assembled, the housing holds the solid-electrolyte membrane in contact with the chip (see figure). The housing includes a water reservoir for keeping the solid-electrolyte membrane hydrated. The housing also includes flow channels for circulating a sample stream of air over the chip: ethylene is brought to the sensing surface predominately by convection in this sample stream. The sample stream is generated by a built-in sampling pump. The forced circulation of sample air contributes to the attainment of a low detection limit.

Manoukian, Mourad↗

Design, Development and Testing of Inconel Alloy IN718 Spherical Gas Bottle for Oxygen Storage

This paper describes the details of design, manufacture and testing of 200 mm diameter spherical gas bottle of Inconel 718 (IN718) with nominal wall thickness of 2.3 mm. Gas bottle was designed for the specified internal pressure loading with a thickness of 2.9 mm at the circumferential weld which was brought down to 2.3 mm at the membrane locations. Hemispherical forgings produced through closed-die hammer forging were machined and electron beam welded to produce a spherical gas bottle. Duly welded gas bottle was subjected to standard aging treatment to achieve the required tensile strength. Aged gas bottle was inspected for dimensions and other stringent quality requirements using various nondestructive testing techniques. After inspection, gas bottle was subjected to pressure test for maximum expected operating pressure and proof pressure of 25 and 37.5 MPa, respectively. Strain gauges were bonded at different locations on the gas bottle to monitor the strains during the pressure test and correlated with the predicted values. The predicted strain matched well with the experimental strain confirming the design and structural integrity.

36 MATERIALS SCIENCE↗

Catalyst Layer Design, Manufacturing and In-line Quality Control

In this project we successfully demonstrated the capabilities of the Reactive Spray Deposition Technology (RSDT) to fabricate large-scale CCMs for advanced PEMWEs that have one-order of magnitude lower PGM loading in their catalyst layers, and performance comparable with the commercial state-of-the-art CCMs. The RSDT is a unique methodology that combines the catalyst synthesis and CCM fabrication in one step and reduces dramatically the time for CCM manufacturing. As fabricated large-scale CCMs with geometric area of 680 cm2 demonstrated excellent activity and durability performance, and the novel duo-recombination layer design paves the way for solving the safety concerns related to PEMWEs. In addition, excellent activity and durability performance has been demonstrated with RSDT fabricated CCMs with thinner membranes and duo RL design. This is a novel approach for further performance improvement of the MEAs for PEMWEs that has been successfully demonstrated for the first time in this project. The integration of the in-situ laser diagnostics system along with the in-line optical quality control system within the RSDT that has been achieved and demonstrated in this project, is an example for possibility of designing and building advanced manufacturing technologies that can meet the requirements of the future manufacturing. Therefore, the RSDT offers a precise real-time monitoring and control of the particles size, composition, loading, porosity, thickness, and defects in the catalysts’ layers, which render this technology as the best candidate for manufacturing of cost effective CCMs for PEMWEs. By using RSDT we successfully met all project’s milestones, Go/No-Go decision, objectives, goals, and deliverables.

08 HYDROGEN↗

Structure and Orientation of Molecular Wires Embedded in Ultrathin Silica Membrane for Artificial Photosynthesis Elucidated by Polarized FT-IRRAS

Surface sensitive infrared spectroscopic methods are employed for elucidating the structure and orientation of charge conducting molecular wires of type oligo(p-phenylenevinylene) covalently anchored on an ultrathin planar Co oxide catalyst surface and embedded in a few nanometer thick amorphous silica membrane. Comparison of polarized FT-IRRAS with nonpolarized grazing angle ATR FT-IR spectra of nanolayer samples supported on a flat Pt surface and transmission spectra of powder samples showed distinct intensity differences for molecular in-plane and out-of-plane modes that reveal the spatial orientation with respect to the oxide surface. All observations support an upright orientation of the molecular wire axis, which is further confirmed by comparison with IRRAS measurements of physisorbed, horizontally positioned wire molecules. The structural integrity of the molecules is maintained after embedding in the silica membrane by plasma-enhanced atomic layer deposition at 40 °C. The results provide the first spectroscopic evidence of perpendicular orientation of the wire molecules. The complementary surface sensitive infrared measurements by FT-IRRAS and grazing angle ATR FT-IR constitute a powerful approach for elucidating the structure and orientation of surface-anchored molecules and the integrity upon casting into oxide layers such as silica for developing artificial photosystems. Use of the nanolayer construct in IRRAS spectroelectrochemical cell configuration will enable in situ monitoring of the structural and orientation integrity of the silica embedded molecular wires under the sustained electron and proton flux conditions of photocatalytic operation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous polymer films deposited on top of porous substrates using plasma-enhanced atomic layer deposition and molecular layer deposition

Molecular layer deposition (MLD) is able to produce ultrathin polymer films with control over thickness, cross-linking, and chemical composition. With these capabilities, MLD should be useful in the fabrication of novel polymer membranes on porous supports. However, confining a continuous MLD film to the surface of porous substrates is difficult because of MLD film growth in the pores. The deposition in the pores lowers the conductance of the porous support. This paper presents a method to deposit continuous polymer films on top of porous substrates. In this method, Al2O3 plasma-enhanced atomic layer deposition (PE-ALD) using trimethylaluminum and oxygen plasma as the reactants was first used to cap the pores of the substrate. Subsequently, a polyamide MLD film was deposited on the Al2O3 PE-ALD capping layer using m-phenylenediamine and trimesoyl chloride as the reactants. The Al2O3 pore caps were then removed from the porous substrate by etching from the backside using a timed exposure to a dilute sodium hydroxide solution. This method was demonstrated using anodic aluminum oxide (AAO) and polyethersulfone (PES) porous substrates. Al2O3 PE-ALD film growth was limited to the top of the porous substrate, resulting in rapid surface recombination or high sticking coefficients for the reactive plasma species within the pores. Gas permeance measurements confirmed the pore capping of the AAO substrates. The reopening of the pores by dissolving the Al2O3 pore caps with a sodium hydroxide solution was monitored using gas permeance versus etch time. The removal of the Al2O3 pore caps from the PES substrates could also dissolve the Al2O3 layer underneath the MLD film. The loss of this Al2O3 layer led to the detachment of the MLD film from the PES substrate. However, the MLD film could be anchored to the PES support at fractures located in the Al2O3 film prior to the MLD. The Al2O3 film fracture allowed the MLD film to anchor firmly to the PES substrate by MLD in the pores of the PES porous substrate. The distance between the anchor points was a function of fracture density. This distance could be controlled by applying a tensile stress to the Al2O3 PE-ALD film to fracture the film through sample bending. This method produced firmly anchored polymer MLD films on top of the PES porous substrates.

Welch, Brian C. (ORCID:000000029747045X)↗