Search NASA⌕ Search

SEARCH · Search NASA

Results for “microCT scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Synthetic Scientific Image Generation with VAE, GAN, and Diffusion Model Architectures

Generative AI (genAI) has emerged as a powerful tool for synthesizing diverse and complex image data, offering new possibilities for scientific imaging applications. This review presents a comprehensive comparative analysis of leading generative architectures, ranging from Variational Autoencoders (VAEs) to Generative Adversarial Networks (GANs) on through to Diffusion Models, in the context of scientific image synthesis. We examine each model's foundational principles, recent architectural advancements, and practical trade-offs. Our evaluation, conducted on domain-specific datasets including microCT scans of rocks and composite fibers, as well as high-resolution images of plant roots, integrates both quantitative metrics (SSIM, LPIPS, FID, CLIPScore) and expert-driven qualitative assessments. Results show that GANs, particularly StyleGAN, produce images with high perceptual quality and structural coherence. Diffusion-based models for inpainting and image variation, such as DALL-E 2, delivered high realism and semantic alignment but generally struggled in balancing visual fidelity with scientific accuracy. Importantly, our findings reveal limitations of standard quantitative metrics in capturing scientific relevance, underscoring the need for domain-expert validation. We conclude by discussing key challenges such as model interpretability, computational cost, and verification protocols, and discuss future directions where generative AI can drive innovation in data augmentation, simulation, and hypothesis generation in scientific research.

Generative Adversarial Networks↗

Using X-ray Micro-Computed Tomography to Three-Dimensionally Visualize the Foregut of the Glassy-Winged Sharpshooter ( Homalodisca vitripennis )

Dissecting the heads of small insects belonging to the order Hemiptera for detailed anatomical investigation with light or scanning electron microscopy is difficult, time-consuming, and destructive, often resulting in sample preparation artifacts. Nevertheless, the structural details of these insects often hold critical information regarding their interactions with bacterial pathogens. For example, the glassy-winged sharpshooter (GWSS) is an efficient vector of the bacterium Xylella fastidiosa, the causal agent of Pierce’s disease in grape vines, but the foregut of this species is exceptionally difficult to dissect. Here, we describe a simple, non-destructive method to investigate the structure of the anterior gut of GWSS using high-resolution micro-computed X-ray tomography (microCT). The use of microCT eliminates the need for destructive dissection and reveals the morphology of small insects in three dimensions, allowing the user to virtually dissect the sample. The use of microCT imaging is a promising and powerful tool in the entomological sciences for studying the structures of vector insects, especially for difficult-to-dissect regions such as the foregut.

54 ENVIRONMENTAL SCIENCES↗

Data for "High-resolution microCT reveals relationships between stomata and interior leaf anatomy in Sorghum"

Includes three different types of stacks, in two folders: "REC_RAW_STACKS.zip" contains: (1) Raw gray-scale reconstructed microCT x-ray scans, in the form of individual stacks per sample. "ML_STACKS.zip" contains: (2) Stacks that have been labeled using a machine-learning mask-RCNN pipeline identifying epidermis, mesophyll, airspace, vascular bundle, and background. (3) Stacks that have stomata locations labeled using a small point. The three types of stacks were used to calculate a variety of anatomical and physiological traits, using ImageJ Macros provided on Github: https://github.com/leakey-lab/microCT-Macros-Fischer. Young leaves from WT and transgenic Sorghum plants. CSV "microCT_REC2_META.csv" contains metadata, including sample/sub-sample labels.

3D↗

Dose Measurement on Microfocus Computed Tomography Scanner

This Standard Operating Procedure (SOP) outlines the steps for measuring dose in x-ray computed tomography (CT) scans [1] on the MicroCT (MCT) system at the High Explosives Application Facility (HEAF) and other systems relevant to the Livermore Explosives Detection Program (LEDP). These systems include: the DHS LLNL MCT in HEAF, aka HEAFCAT, DHS LLNL MCT Testbed (TB) in B327, and the MCTs at TRMG, HEX2, HMEX, CBX, and IPMO, as described in Section 4.

42 ENGINEERING↗

Bone Loss During Spaceflight: Available Models and Counter-Measures

There is ongoing concern for human health during spaceflights. Of particular interest is the uncoupling of bone remodeling and its resultant effect on calcium metabolism and bone loss. The calculated average loss of bone mineral density (BMD) is approximately 1-1.5% per month of spaceflight. The effect of decreased BMD on associated fractures in astronauts is not known. Currently on the International Space Station (ISS), bone loss is managed through dietary supplements and modifications and resistance exercise regimen. As the duration of space flights increases, a review of the current methods available for the prevention of bone loss is warranted. The goal of this project is to review and summarize recent studies that have focused on maintaining BMD during exposure to microgravity. Interventions were divided into physical (Table 1), nutritional (Table 2), or pharmacologic (Table 3) categories. Physical modalities included resistance exercise, low level vibration, and low intensity pulsed ultrasound. Nutritional interventions included altering protein, salt, and fat intake; and vitamin D supplementation. Pharmacologic interventions included the use of bisphosphonates and beta blockers. Studies reported outcomes based on bone density determined by DXA bone scan, micro-architecture of histology and microCT, and serum and urine markers of bone turnover. The ground analog models utilized to approximate osseous physiology in microgravity included human patients previously paralyzed or subjects confined to bedrest. Ground analog animal models include paralysis, immobilization and ovariectomies. As a result of the extensive research performed there is a multi-modality approach available for the management of BMD during spaceflight that includes resistance training, nutrition and dietary supplements. However, there is a paucity of literature describing a formalized tiered protocol to guide investigators through the progression from animal models to human patient ground analogs to experiments on the ISS. With regards to testing, further evaluation to determine the association between non-invasive tests and fracture during and after spaceflight needs to be performed.

Morris, Jonathan↗

Characterization of Incremental Markings in the Sagittal Otolith of the Pacific Sardine ( Sardinops sagax ) Using Different Imaging Modalities

Teleost fish possess calcium carbonate otoliths located in separate chambers (utriculus, sacculus, and lagena) of their membranous labyrinth. This study analyzed the surface topography of the sagittal otolith of the Pacific sardine (Sardinops sagax) and the daily and annual increments in these otoliths. The otolith surface, characterized by laser scanning confocal microscopy for the first time, consisted of a system of prominent ridges and valleys (grooves), but it is unclear whether these structures are functional or represent time-resolving markings reflecting growth periodicity. Within the first-year volume, daily increments, each consisting of an incremental (more mineralized) and a discontinuous (less mineralized) zone, were resolved by optical microscopy and backscattered electron (BSE) imaging in the scanning electron microscope (SEM). Daily growth increments could, however, not be resolved in volumes formed after the first year, presumably because otolith growth markedly slows down and spacing of incremental markings narrows in older fish. Throughout otolith growth, the crystalline network continues across the discontinuous zones. Fluorochrome labeling provides additional information on growth after the first year. Compared with optical and BSE imaging, synchrotron microComputed Tomography of intact otoliths (with 0.69 µm volume elements) was less able to resolve daily increments; X-ray phase contrast reconstructions provided more detail than reconstructions with absorption contrast. Future research directions are proposed.

59 BASIC BIOLOGICAL SCIENCES↗

Spatial Resolution of a microCT Scanner

We have measured the spatial resolution of the 450 kV test-bed microCT scanner. We have also modeled the resolution analytically. The model and measurement show correspondence within 5%. Our measurement method was to use a thin tungsten wire to act as an impulse function. Therefore, the image is the impulse response, also called the point spread function (PSF) of the system. The Fourier transform (FT) of the impulse response is the modulation transfer function (MTF) of the system. We report the MTF here. By moving the wire at different positions in the scan field of view (FOV), we can measure MTF at different positions in the FOV. Since our imaging system is radially symmetric, we report MTF in two directions, radial and tangential as shown in Figure 1. The radial direction is along the line from isocenter to the wire, and the tangential is perpendicular to it.

42 ENGINEERING↗

Towards Quantifying and Correlating RTV Intumescence to Entry-Relevant Conditions

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also adopted to bond instrumentation plugs of temperature and pressure sensors into heatshield’s tiles. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Experimental data has also shown heating rate-dependent swelling (or intumescence) and shrinking of RTV, these volume changes may cause roughness-induced boundary layer transition. Outgassing and surface oxide formation of RTV upon decomposition also occur, which can be sources of contamination of heat shield sensors. This combination of detrimental effects motivates a critical need to develop a high-fidelity model for RTV ablation. As a first critical step in RTV modeling, a comprehensive material properties database for RTV was collected that account for the lack of data in properties such as pyrolysis char yield, shape change, virgin and char porosity. The next step is to quantify the volume change of RTV as a function of temperature. While this was done in previous campaigns, limited data was collected which showed a possible heating rate dependent intumescent behavior. To further understand the intumescence phenomenon of RTV, numerous dedicated experiments were performed at Beamline 8.3.2 of the Advanced Light Source, where RTV samples were heated while X-ray scans were taken in situ. Micro-Computed Tomography scans were taken in situ for low heating rates (≤ 60 °C/min), whereas continuous radiography scans were taken for higher heating rates (≤ 1500 ºC/min). Unconstrained samples and samples constrained in different holders (quartz, graphite, FiberForm and PICA) were tested to determine the change in intumescence due to confinement. Using deep learning techniques, the tomographies and radiographies are segmented to obtain volume change, porosity, pore size distributions and connectivity. From the results obtained, modifications to the previous RTV intumescence model are proposed, along with preliminary comparisons to testing RTV at high-enthalpy facilities.

RTV↗