Gravity Effects in Two-Phase Microgap Flow

The high power density of emerging electronic devices is driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for aerospace applications, but the lack of acceptable models and correlations for orientation- and gravity-independent operation has limited their use. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging systems to exploit this thermal management technique and streamline the technology development process. As a first step toward understanding the effect of gravity in two-phase microgap flow and transport, in an earlier effort, the authors studied the effects of evaporator orientation, mass flux, and heat flux on flow boiling of HFE7100 in a 1.01 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. Orientation-independence, defined as achieving similar critical heat fluxes, heat transfer coefficients, and flow regimes across orientations, was achieved for mass fluxes of 400 kg/sq.m-s and greater (corresponding to a Froude number of about 0.8). In the present effort, the authors have studied the effects of gravity, mass flux, and subcooling on flow boiling of HFE7100 in a 0.17 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. The Flow Boiling in Microgap Coolers payload experienced about three minutes of weightlessness and shorter periods of high-g (up to about 5 g) during two recent flights aboard the Blue Origin New Shepard reusable launch vehicle. The results from the flight experiments will be presented and compared with published criteria for achieving gravity-independence.

Robinson, Franklin L.

Orientation Effects in Two-Phase Microgap Flow

The high power density of emerging electronic devices is driving the transition from remote cooling, which relies on con-duction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for other applications (e.g., spacecraft and aircraft). The lack of acceptable models and correlations for orientation- and gravity-independent operation has limited the use of two-phase coolers in such applications. Previous research has revealed that gravita-tional acceleration plays a diminishing role in establishing flow regimes and transport rates as the channel size shrinks, but there is considerable variation among the proposed microscale criteria and limited research on two-phase flows in low aspect ratio mi-crogap channels. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging sys-tems to exploit this thermal management technique and streamline the technology development process. As a first step toward understanding the effect of gravity on two-phase microgap flow and transport, in the present effort the authors have studied the effect of evaporator orientation and mass flux on near-saturated flow boiling of HFE7100 in a 1.01 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. Orientation-independence, defined as achieving similar critical heat fluxes, heat transfer coefficients, and flow regimes across evaporator orientations, was achieved for mass fluxes of 400 kg/m2-s and greater. The present results are compared to pub-lished criteria for achieving gravity-independence.

orientation

Orientation Effects in Two-Phase Microgap Flow

The high power density of emerging electronic devices is driving the transition from remote cooling, which relies onconduction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolersemploy the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for other applications (e.g., spacecraft and aircraft). The lack of acceptable models andcorrelations for orientation- and gravity-independent operation has limited the use of two-phase coolers in suchapplications. Previous research has revealed that gravitational acceleration plays a diminishing role in establishing flow regimes and transport rates as the channel size shrinks, but there is considerable variation among the proposed microscale criteria and limited research on two-phase flows in low aspect ratio microgap channels. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging systems to exploit this thermal management technique and streamline the technology development process.

orientation

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale

Challenges and Opportunities in Gen3 Embedded Cooling with High-Quality Microgap Flow

Gen3, Embedded Cooling, promises to revolutionize thermal management of advanced microelectronic systems by eliminating the sequential conductive and interfacial thermal resistances which dominate the present 'remote cooling' paradigm. Single-phase interchip microfluidic flow with high thermal conductivity chips and substrates has been used successfully to cool single transistors dissipating more than 40kW/sq cm, but efficient heat removal from transistor arrays, larger chips, and chip stacks operating at these prodigious heat fluxes would require the use of high vapor fraction (quality), two-phase cooling in intra- and inter-chip microgap channels. The motivation, as well as the challenges and opportunities associated with evaporative embedded cooling in realistic form factors, is the focus of this paper. The paper will begin with a brief review of the history of thermal packaging, reflecting the 70-year 'inward migration' of cooling technology from the computer-room, to the rack, and then to the single chip and multichip module with 'remote' or attached air- and liquid-cooled coldplates. Discussion of the limitations of this approach and recent results from single-phase embedded cooling will follow. This will set the stage for discussion of the development challenges associated with application of this Gen3 thermal management paradigm to commercial semiconductor hardware, including dealing with the effects of channel length, orientation, and manifold-driven centrifugal acceleration on the governing behavior.

microchannel

Flow Boiling in Microgap Coolers - Suborbital Flight Results

Flow Boiling in Microgap Coolers (FBMC) is a thermal management technique that provides embedded, on-site heat removal for power dense electronic components and systems. The dielectric coolant undergoes liquid-to-vapor phase change as it passes through channels integrated within or between devices. By facilitating direct contact between the coolant and heat-generating devices and relying on phase change, the system provides tight temperature control, hot spot mitigation, very high heat transfer coefficients, and low pumping power. Ground tests demonstrated removal of high heat fluxes (up to 500 kW/m2), very high coefficients of performance (up to 40 W of heat transferred per W of pumping power), and consistent performance across five evaporator orientations under the appropriate conditions. As a follow-on study and to better assess the role of gravity on such two-phase systems, the FBMC payload was developed and flown twice aboard the Blue Origin New Shepard space vehicle in January and May 2019. Each flight exposed the payload to weightlessness (150 seconds below 0.01 g) and shorter periods of high-g during ascent (up to 3 g) and descent (up to 5 g). The flow boiling performance was consistent independent of the acceleration levels, which provides confidence that such systems will provide consistent performance when tested on the ground, orbiting or traveling through weightlessness, and operating on the surface of the Moon, Mars, and other planetary bodies. Details of the flight results, payload development, flight environment, and planned future testing will be presented.

Flow boiling

Breakdown Features of Various Microstrip-Type Gas Counter Designs and Their Improvements

Breakdown mechanisms and spurious pulses, the precursors to some breakdowns, were studied experimentally for both uncoated and coated Microstrip Gas Counters (MSGCs) of different geometries, as well as for MicroGap Counters (MGCs) and for the "Compteur A Trou" (CAT). It was found that in all cases the breakdowns occurred through surface streamers, although the exact mechanism of streamer formation depended on the particular detector design. Based on these studies, new designs of microstrip detectors, in which the role of the substrate was minimized, were elaborated and tested. In some of these detectors, especially with large pitches (greater than 2mm), gains up to 2-3 x 10(exp 5) were achieved together with good rate characteristics. The ultimate gain limit in all geometries was still set by spark-inducing streamers which appeared at some critical charge density in the avalanche. To avoid this, and particularly to enhance the performance of small-pitch MSGCs, preamplification structures can be used. Utilizing a parallel plate avalanche chamber as a front end to an MSGC resulted in an overall gain of approximately 10(exp 6), limited in this case only by charge saturation.

Peskov, V.